Airbus A320-271N
Service difficulty reports · 1,625
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A320271N' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A320271N' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR GTIA2022110736763Megaphone · inoperativeFWD MEGAPHONE INOP-R+R FWD MEGAPHONE TEST OK IAW AMM 25-65-00.SDR GTIA2022110736761Bottle · dischargedR1 DOOR ASSIST BOTTLE LOW PRESSURE.-SERVICED DOOR ASSIST BOTTLE I.A.W AMM 52-10-00-614-001-A.SDR GTIA2022110336758Fan · faultedOCASSIONAL VIBRATION AND LIGHT BURNING SMELL IN CRUISE FL 340 COMPLIED WITH COM PROCEDURES ( EXTRACT FAN VENT AVNCS SYS FAULT NOT DISPLAYED )-R/R AVIONICS EXTRACT FAN IAW AMM 21-26-51 OPS CHECK GOOD. THIS CLOSES DMI #2947444-1 PLACARD REMOVED MOC NOTIFIEDSDR GTIA2022110336757Unknown · odorON CLIMB SMELL LIKE BURNT RUBBER FROM AVIONICS AREA. WENT AWAY AFTER 3 MINUTES IN DESCENT AROUND 20.000 FT SMELL COME BACK STRONG FOR 5 MINUTES NOT COMING FROM AIR CONDITIONING-PERFORMED T.S.M. 24-00-00-810-823A SEARCHING FOR POSSIBLE ARCING, CHAFING OR SHORT SDR GTIA2022110336755Battery · no testEPSU BATTERY 12WL FAILED ON CAPACITY TEST. SDR REQUIRED.-VERIFIED NR # 5001189163-0030, EPSU BATTERY HAS BEEN REPLACED (12WL) I.A.W AMM 33-51-38-400-002-A REV. 74. TEST OK.SDR GTIA2022110136750Bleed Valve · faulted"ENG 1 SYS FAULT -FOLLOWED TSM 75-32-00-810-541-A PERFORMED ENG 1 IDLE TEST IAW AMM 71-00-00. NO FAULT INDICATED. DUE TO HITORY, R&R ENG 1 HPC BLEED VALVE IAW AMM 75-32-02. PERFORMED NO.3 POWERPLANT OPERTATION TEST IAW AMM 71-00-00. NO FAULTS INDICATED VALVVESDR GTIA2022102836744Flashlight · inoperativeFA SWEVEL SEAT FLASHLIGHT NOT WORKING -REMOVED AND REPLACED FA SWEVEL SEAT FLASHLIGHT IAW CMM 25-60-02SDR GTIA2022102436739Bottle · dischargedR2 DOOR ASSIST BOTTLE REQUIRES NEEDS SERVICING.-SERVICED R2 DOOR ASSIST BOTTLE IAW AMM 52-10-00.SDR GTIA2022102436738Unknown · odorFAINT MUSTY SMELL DETECTED ON DECENT FROM 5000'. THRUST AT IDLE. PACK 1 SELECTED OFF SMELL WENT AWAY.-PERFORMED ISOLITALION OF ORDOR IAW AMM 21-00-00. RUN ENINES AND APU TO FIND MUSTY SMELLY. CUOLDNOT DUPLICATE. NO SMELL NOTICED AT THIS TIME A/C OK FOR CONTINSDR GTIA2022102436735Skin · damagedBURNT MARK FOUND AT FR 68-69 STRINGER 44. RAF 294913001. OPEN SDR ITEM.-VERIFIED LHT NR# 5001186184-0010. REPAIR WAS PERFORMED AS PER SRM 53-41-11-300-054 REV 33. REPAIR IS CATEGORY A AS PER SRM 53-41-42-205-053 REV 33. DEFECT MAPPED IN TRAXSDR GTIA2022102436734A/C Pack · odorDIRTY SOCK SMELL COCKPIT PACK 1 OFF. X BLEED SHUT. SMELL SUBSIDED ( PACKS A320 WITH MOD 31283/MP P7125 (FWC H2-F1 STND) AND WITH MOD. 30626/MP K6443 (ENHANCED ECS) - AT OR BELOW FL 310 )-PER TSM 05-50-00-810-831-A PERFORM LEVEL C REMOVAL OF THE CONTAMINATION OSDR GTIA2022102136732Megaphone · damagedFA FORWARD MEGAPHONE BROKEN-R/R FA FWD MEGAPHONE IAW EMER EQUIP DRAWING A320 EMER EQUIP-2SDR GTIA2022102136731A/C Pack · odorSTONG "DIRTY SOCKS" SMELL IN COCKPIT AND IN FRONT CABIN DURING DESENT, IDEL POWER COMING FROM PACK 1 -PERFORMED TSM 05-50-00 FOR CAUSE OF ODOR , INSPECTED AIRCRAFT FR SIGNS OF LEAKAGES, NONE NOTED , FOUND LEFT PACK AS CAUSE OF ODOR SEE LOG PAGE 2943984-2 FORSDR GTIA2022102136730Battery Pack · no testEPSU BATTERY (12WL) FAILED ON TEST. SDR REQD. REF AERMON NR# 2022-502765.-VERIFIED AEROMON NR# 2022-502756 EPSU BATTERY (12WL) WAS REPLACED AS PER AMM 33-51-38 REV 74. TEST OK. SDR CREATED.SDR GTIA2022102136729Battery Pack · no testEPSU BATTERY (10WL) FAILED ON TEST. SDR REQ. REF AEROMON NR# 2022-502753-VERIFIED AEROMON NR# 2022-502753 EPSU BATTERY (1OWL) WAS REPLACED AS PER AMM 33-51-38 REV 74. TEST OK. SDR CREATEDSDR GTIA2022102136728Battery Pack · no testEPSU BATTERY (11WL) FAILED ON TEST. SDR REQD. REF AEROMON NR# 2022-502755-VERIFIED AEROMON NR# 2022-502755 EPSU BATTERY (11WL) WAS REPLACED AS PER AMM 33-51-38 REV 74. TEST OK. SDR CREATEDSDR GTIA2022102136727Battery Pack · no testEPSU BATTERY 913WL) FAILED ON TEST SDR REQD. EPSU BATTERY (13WL) WAS REPLACED AS PER AMM 33-51-38 REV 74. TEST OK. SDR CREATEDSDR GTIA2022101336718Flashlight · inoperativeREF LOGPAGE 2799859-1 L2 P/A FLASHLIGHT BLINKING RED -R&R FLASHLIGHT ASSBLY IAW CMM 25-60-02. THIS CLOSES DMI 2799859-1. MOC NOTIFIED. PLACARD REMOVEDSDR GTIA2022101036712Pressure Switch · warning messageG ENG PUMP INOP ( ECAM WARNINGS & CAUTIONS PUMP LO PR - ENG PUMP LO PR )-R/R LOW PRESSURE WARNING SWTICH ON ENGINE 1 IAW AMM 29-11-17. OPS CHECK GOOD. LEAK CHECK GOOD. NO DEFECTS NOTED. THIS CLEARS MDDR 38861. PLACARD REMOVED MOC NOTIFIEDSDR GTIA2022100636711None · noneSTRONG PLASTIC ODOR IN COCKPIT DESCENDING THROUGH 21000FT WITH THRUST IDLE. SELECTED XBLEED OFF AND PACK 1 OFF AND ODOR DISSIPATED COMPLETELY.-PERFORM TSM 05-50-00-810-831. RAN PACK 1&2 & INSPECTED FOR CONTAMINATION I.A.W AMM 21-51-00. FOUND NO EVIDENCE OF CONSDR GTIA2022100636709None · noneR2 DOOR DAMPER REQ SVC -SVCD R2 DOOR ASSIST BOTTLE IAW AMM 52-10-00SDR GTIA2022100636708None · noneSTRONG ODOR OF BURNING PLASTIC WHEN WE STARTED DECENDING. NO HOT SPOTS ON BRAKER PANELS. FAS CHECKED LAVS/CABIN ALL OK. ODOR WOULD DISSIPATE AND RETURN WHEN ENGINES DECELERATED TO IDLE-PERFORMED ENGINE RUN ON BOTH #1 & #2 ENG IAW AMM 71-00-00. COULD NOT DUPLICSDR GTIA2022100636707None · noneON SHORT FINAL F/A REPORTED SMELL LIKE DIRTY SOCK-ACCOMPLISHED TSM 05-50-00-810-831 AND RAN ENGINES WITH CREW..ODOR ISOLATED TO PACK 2. SEE LP 2883717-2 FOR CORRECTIVE ACTION.SDR GTIA2022100636706None · noneEXTREMELY STRON SMELL ON FLIGHT DECK DESCENDING THRU 3000 WITH IDH POWER NO SMELL BACK CABIN PACK 1 WAS SHUTDOWN AND SMELL WENT AWAY AFTER 2-3 MINUTES FUME EVENT.-COMPLIED WITH TSM 5-50-00-310-831A AND FOUND PACK #1 AS THE CAUSE SEE ITEM 2969198-2 FOR CORRECTISDR GTIA2022100336702None · noneSTRONG SMELL IN FLIGHT DECK AT FL180 DESCENDING. AFTER PACK 1 TURNED OFF SMELL WENT AWAY. FA DIDNT NO REPORT A SMELL.-PERFROMED TSM 05-50-00-810-832-A. PERFROMED SUBTASK A PARAGRAPH 3 (3) IAW AMM 49-00-00-200-812-A. NO SMELS NOTED. A/C OK FOR SERVICE AT THIS TSDR GTIA2022100336701Megaphone · damagedFOUND FWD GALLEY MEGA PHONE MISSING VOLUME KNOB.-R/R FWD GALLEY MEGA PHONE IAW SPIRIT DRAWING A320-EMER EQUIP REV 3.SDR GTIA2022100336700None · noneL2 DOOR ASSIST BTL REQUIRES SERVICING.-SERVICED L2 DOOR ASSIST BTL IAW AMM 52-10-00. TO PROPER LEVEL.SDR GTIA2022100336699None · noneHEARD LOUD POP , FOLLOWD BY A SMELL OF BURNING E;EC ON CLIMB OUT AR 22,000 FT . DIVERTED TO RIC. ON TAXI WAY WAITING FOR GATE SMELL AND NOISE GOT WORSE , NO ECAM AT THIS TIME .. ANOTHER LOUD NOISE HAPPENED AND SMELL OF BURNING. AT THAT TIME GOT ECAM FAULT -PERSDR GTIA2022100336696None · noneSTRONG SMELL IN THE FLIGHT DECK AT 6000FT IDDLE POWER. SMELL WENT AWAY 1 MIN AFTER PACK 1 WAS TURNED OFF. FLIGHT ATTENDANTS DID NOT SMELLED ANYTHING. NO FURTHER SMELL AFTER PACK 1 OFF. -PERFORMED TROUBLESHOOTING PER TSM 05-50-00-810-831-A. PERFORMED LEVEL B DESDR GTIA2022100336695None · noneL2 DOOR ASSIST BTL. REQUIRES SERVICING.-SERVICED L2 DOOR ASSIST BTL. IAW AMM 52-10-00. TO PROPER LEVEL.SDR GTIA2022100336693None · noneR2 DOOR NOT ARMING LOW PRESURE INDICATION ON FA FAP-SERVICED R2 DOOR ASSIST BOTTLE REF AMM 52-10-00. OPS AND LEAK CHECK GOODSDR GTIA2022100336692Epsu · no testEPSU BATTERY (13WL) FAILED ON TEST SDR REQD. REF. NR # 5001184122-0010.-VERIFIED NR # 5001184122-0010, EPSU BATTERY (13WL) WAS REPLACED AS PER AMM 33-51-38 REV. 74. TEST OK. SDR CREATED.SDR GTIA2022100336691Epsu · no testEPSU BATTERY (10WL) FAILED TEST. REF. NR # 5001184122-0010. SDR REQUIRED-VERIFIED NR # 5001184122-0010, EPSU BATTERY (10WL) WAS REPLACED AS PER AMM 33-51-38 REV. 74, TEST OK. SDR CREATED.SDR GTIA2022100336690Epsu · no testEPSU BATTERY (11WL) FAILED ON TEST. REF. NR # 5001184122-0010, SDR REQUIRED-VERIFIED NR # 5001184122-0010, EPSU BATTERY (11WL) WAS REPLACED AS PER AMM 33-51-38 REV. 74, TEST OK. SDR CREATED.SDR GTIA2022100336689Epsu · no testEPSU BATTERY (12WL) FAILED ON TEST. REF. NR# 5001184122-0010. SDR REQUIRED.-VERIFIED NR # 5001184122-0010, EPSU BATTERY (12WL) WAS REPLACED AS PER AMM 33-51-38 REV. 74, TEST OK. SDR CREATED.SDR GTIA2022092936684None · noneL1 DOOR ASSIST BATTLE LOW-SERVICE L1 DOOR ASSIST BATTLE IAW AMM 52-10-00SDR GTIA2022092336679None · fault messageEPSU BATTERY (10WL) FAILED ON CABIN EMER. LIGHTING TEST SDR REQUIRED-VERIFIED NR# 5001182084-0010, EPSU BATTERY (10WL) REPLACED I.A.W AMM 33-51-38 REV. 74 TEST SATISFACTORY SDR CREATEDSDR GTIA2022091936665Flashlight · inoperativeFWD F/A FLASHLIGHT INOP ( FLASHLIGHT AND HOLDERS (FLIGHT DECK OR CABIN) )-R/R F/A FWD OUTBOARD SEAT FLASH LIGHT ASSEMBLY IAW CMM 25-60-13. OPS CHK GOOD. THIS CLEARS MDDR #37266, PLACARD REMOVED, MOC NOTIOFIED.SDR GTIA2022090836648Access Panel · corrodedCORROSION ON ACCESS PANEL316AR FWD LOWER APU COMPARTMENT. RAF-01 290730802 GENERATED FOR DENT MAPPING PURPOSE ONLY-ACCOMPLISHED 316AR DOOR OUTER SKIN REPAIR IAW SRM 52-41-22-300-003. THIS REPAIR IS CAT ASDR GTIA2022090236634None · noneDURING TAKE OFF & CLIMB BELOW 10,000 - N2 VIBE ECAM - N2 VIBE WAS 5.6 AND CLIMBING OBSERVED ON ENG 1 -REF TSM 71-00-00-810-873-A PERFORMED STEPS 4A-1 - 4A-5 NO DEFECTS NOTED AT THIS TIME MWI REMAINS OPE A/C OK FOR CONTINUED SERVICE ( ENG #1 )SDR GTIA2022083036628Megaphone · damagedFWD MEGAPHONE VOLUME KNOB MISSING-R/R FWD MEGAPHONE IAW AMM 25-65-01, OPS CHECK GOODSDR GTIA2022083036625None · noneAS PER WEEKLY CHECK R1 DOOR ASSIST BOTTLE REQUIRES SERVICING -SERVICED R1 DOOR IAW AMM 52-10-00. TO PROPER PRESSURESDR GTIA2022083036624Flashlight · inoperativeREF 2951839-1 L1 FLASHLIGHT-R/R L1 FLASHLIGHT IAW CMM 25-60-13. OPS CHECK GOOD. THIS CLOSES DMI. PLACARD REMOVED. MOC NOTIFIED.SDR GTIA2022083036622None · noneL1 OUTBOARD EMERGENDY FLASHLIGHT INOP ( FLASHLIGHT AND HOLDERS (FLIGHT DECK OR CABIN) )-R/R L1 FLASHLIGHT IAW CMM 25-60-13. OPS CHECK GOOD. THIS CLOSES DMI. PLACARD REMOVED. MOC NOTIFIED.SDR GTIA2022082636620None · noneR2 DOOR ASSIST BOTTLE LOW-SERVICED R2 DOOR ASSIST BOTTLE IAW AMM 52-10-00.SDR GTIA2022082636617None · noneL2 DOOR ASSIST BOTTLE BELOW WEEKLY LIMIT-SERVICED L2 DOOR ASSIST BOTTLE TO PROPER PSI PER AMM 52-10-00SDR GTIA2022082236604None · noneDIRTY SOCK SMELLL ON DESCEND AND APPROACH COMING FROM PACK 1-PERFORMED TSM FOR CAUSE OF CABIN ODOR REF 05/50/00-810- 831-A IDENTIIFIED PACK 1 AS CONTAMINATED SEE NEXT ITEM FOR PACK 1 DEACTIVATION AND MELSDR GTIA2022082236602None · noneL2 DOOR ASSIST BOTTLE LOW-SERVICED L2 DOOR ASSIST BOTTLE IAW AMM 52-10-00SDR GTIA2022082236601None · noneAWKWARD "SAGGY" SMELL FROM PACKS FA'S,PILOTS,PASSENGERS REPORTD SMELL IN ALL PHASES OF FLIGHT -T/S IAW TSM 05-50-00. FIND APU LEAKING OIL. ACCOMPLISHED DECONTAMINATION OF ENVIROMENTAL SYSTEM IAW AMM 21-00-00. OPS CK NORMAL AT THIS TIME.SDR GTIA2022081836593None · noneL2 DOOR ASSIST BOTTLE BELOW WEEKLY LIMIT-SVC L2 DOOR ASSIST BOTTLE TO PROPER PSI PER AMM 52-10-00.
Back to Airbus A320-271N