Airbus A321-211

Service difficulty reports · 12,330

Newest first. General aviation reporting is voluntary.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE aircraft_model_key = 'A321211'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR AALA201910159057Hinge Arm · wornAIRCRAFT IN BASE MAINTENANCE: RIGHT HAND ELEVATOR #6 HINGE ARM BEARING WORN / OUT OF LIMIT ON THE RIGHT HAND HORIZONTAL STABILIZER. REPLACED #6 HINGE ARM PER AMM 55-16-42-400-001-A.Oct 4, 2019 · N184US · Airbus A321211 · Elevator StructureSDR AALA2019102199024Floor Panel · delaminatedAIRCRAFT IN BASE MANTENANCE: CABIN FLOOR PANEL 231ZH DELAMINATED. REPLACED FLOOR PANEL PER SRM 53-02-00-300-011.Oct 3, 2019 · N185UW · Airbus A321211 · Fuselage Floor PanelSDR AALA2019102199021Floor Panel · delaminatedAIRCRAFT IN BASE MAINTENANCE: CABIN FLOOR PANEL 231YH DELAMINATED. REPLACED FLOOR PANEL PER SRM 53-02-00-300-011.Oct 3, 2019 · N185UW · Airbus A321211 · Fuselage Floor PanelSDR AALA2019102199019Floor Panel · delaminatedAIRCRAFT IN BASE MAINTENANCE: CABIN FKLOOR PANEL 241BF DELAMINATED. REPLACED FLOOR PANEL PER SRM 53-02-00-300-011.Oct 3, 2019 · N185UW · Airbus A321211 · Fuselage Floor PanelSDR AALA201910049002Battery · no testAIRCRAFT WAS NOT GROUNDED: FLIGHT ATTENDANT FLASHLIGHT 1L DOOR WAS NOT FLASHING. MAINTENANCE REPLACED FLASHLIGHT BATTERY PER STANDARD PRACTICES.Oct 3, 2019 · N176UW · Airbus A321211 · Emergency EquipmentSDR AALA201910049005Decoder · unreliableAIRCRAFT NOT GROUNDED: PILOT REPORTS 1R DOOR SHOWS LOW PRESSURE ON CIDS FAP PANEL. BOTTLE INDICATION SHOWS IN GREEN. MAINTENANCE REPLACED 300RH1 DEU B IAW AMM 23-73-47. OPS CHECK GOOD.Oct 3, 2019 · N194UW · Airbus A321211 · Emergency EquipmentSDR AALA201910269013Stop Fitting · wornAIRCRAFT IN BASE VISIT: WEAR ON SPOILER 2 (ACTUATOR STOP BOLT) ON LH WING (1 EA). PERFORMED PERMANENT REPAIR LOC ON ACTUATOR STOP BOLT ON SPOILER 2 OF LH WING IAW A321 SRM 57-70-00-300-003 STEP 2A.Oct 2, 2019 · N184US · Airbus A321211 · SpoilersSDR AALA201910269014Stop Fitting · wornAIRCRAFT IN BASE VISIT: WEAR ON SPOILER 3 (ACTUATOR STOP BOLT) ON LH WING (1 EA). PERFORMED PERMANENT REPAIR LOC ON ACTUATOR STOP BOLT ON SPOILER 3 OF LH IAW A321 SRM 57-70-00-300-003 STEP 2A.Oct 2, 2019 · N184US · Airbus A321211 · SpoilersSDR AALA201910189021B-Nut · looseAIRCRAFT WAS GROUNDED: F/A CREW REPORTS DURING LAST 5 MIN ODOR IN AFT CABIN (#3 DOORS AND AFT) EYE IRRITATION, BURNING SENSATION IN NOSE, STRONG SMELL OF DIRTY BURNING SOCKS. LASTED UNTIL A/C ON GROUND AND DEPPRESS. MAINTENANCE FOUND HYD LEAKS IN BLUE SYS COMPOct 2, 2019 · N190UW · Airbus A321211 · Hydraulic System, MainSDR AALA201911229025Stringer · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON AFT CARGO COMPARTMENT STRINGER BETWEEN FR 56 AND FR 57 AT S43L. REPLACED STRINGER PER SRM 51-42-11.Sep 30, 2019 · N186US · Airbus A321211 · Fuselage Main, Longeron/StringerSDR AALA201911229024Stringer · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON AFT CARGO COMPARTMENT STRINGER BETWEEN FR 56 AND FR 57 AT S42L. REPLACED STRINGER PER SRM 51-42-11.Sep 30, 2019 · N186US · Airbus A321211 · Fuselage Main, Longeron/StringerSDR AALA201910179022Attach Bolt · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON LEFT WING LEADING EDGE SLAT TRACK #7 LOWER ATTACHMENT BOLT AT WS 7316 AND RIB 13. REPLACED BOLT PER AMM 27-84-65-400-002A.Sep 30, 2019 · N185UW · Airbus A321211 · Leading Edge DevicesSDR AALA2019100219015Battery · no testAIRCRAFT WAS NOT GROUNDED: EMERGENCY LIGHT SIGN AT 3L DOOR INOPERABLE. MAINTENANCE REPLACED POWER BATTERY PER AMM 33-51-38.Sep 30, 2019 · N178US · Airbus A321211 · Emergency LightingSDR AALA2019102199018Fitting · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON RIGHT HAND DOOR CUT OUT SILL SHAPE FITTING AT FR 66 AND S23R. REPLACED SILL SHAPE FITTING PER SRM 51-42-11.Sep 29, 2019 · N186US · Airbus A321211 · Fuselage Main, Attach FittingsSDR AALA201911229030Shear Plate · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON SHEAR PLATE AT FR 70 AND S23R. REPLACED SHEAR PLATE PER SRM 51-72-11.Sep 29, 2019 · N186US · Airbus A321211 · Fuselage Miscellaneous StructureSDR AALA201911229026Fitting · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON R4 DOOR DUT OUT LOWER SILL SHAPE FITTING AT FR 65 AND S23R. REPLACED SILL SHAPE FITTING PER SRM 51-42-11.Sep 29, 2019 · N186US · Airbus A321211 · Fuselage Miscellaneous StructureSDR AALA2019102109003Seat Track · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON SEAT TRACK AT FR 20 AND -Y765. REPLACED SEAT TRACK PER SRM 51-42-11.Sep 29, 2019 · N186US · Airbus A321211 · Fuselage, Seat/Cargo Attach FittingsSDR AALA2019102199017Door Sill · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON LEFT HAND DOOR CUT OUT LOWER SILL PLATE BETWEEN FR 66 AND FR 68 AT +Y1732. REPLACED SILL PLATE PER SRM 51-72-11.Sep 29, 2019 · N186US · Airbus A321211 · Fuselage Miscellaneous StructureSDR AALA2019102199012Seat Track · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON SEAT TRACK AT FR 20 AND -Y1292. REPLACED SEAT TRACK PER SRM 51-42-11.Sep 29, 2019 · N186US · Airbus A321211 · Fuselage, Seat/Cargo Attach FittingsSDR AALA2019102199010Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON FLOOR BEAM BETWEEN FR 68 AND FR 69 AT S23R. REPLACED FLOOR BEAM PER SRM 51-42-11.Sep 29, 2019 · N186US · Airbus A321211 · Fuselage Main, Floor BeamSDR AALA201910109024Fitting · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON RIGHT HAND AFT DOOR CUT OUT CORNER FITTING AT FR 68 AND S23R. REPLACED CORNER FITTING PER SRM 51-42-11.Sep 29, 2019 · N186US · Airbus A321211 · Fuselage Main, Attach FittingsSDR AALA201910109022Door Frame · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON RIGHT HAND AFT DOOR CUT OUT LOWER SILL AT FR 68. REPLACED LOWER SILL PER SRM 51-72-11.Sep 29, 2019 · N186US · Airbus A321211 · Fuselage Main, StructureSDR AALA201910089026Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON FLOOR BEAM AT FR 67 AND Y765. REPLACED FLOOR BEAM PER SRM 51-72-11.Sep 29, 2019 · N186US · Airbus A321211 · Fuselage Main, Floor BeamSDR AALA2019100879048Seat Track · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON SEAT TRACK AT FR 65 AND +Y765. REPLACED SEAT TRACK PER SRM 51-72-11.Sep 29, 2019 · N186US · Airbus A321211 · Fuselage, Seat/Cargo Attach FittingsSDR AALA2019100749035Hinge Fitting · wornAIRCRAFT IN BASE MAINTENANCE: RIGHT HAND MAIN LANDING GEAR DOOR FORWARD HINGE FITTING WAS PREVIOULSY REPAIRED DUE TO WEAR PER EA 260332A AND NOW REQUIRES REPLACEMENT AS OUTLINED IN THE PERMANENT REPAIR PROCECURES IN EA 260332A AND EA 297900. REPLACED FORWARD HSep 29, 2019 · N182UW · Airbus A321211 · Landing Gear DoorsSDR AALA201910109032Attach Bolt · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON RIGHT WING LEADING EDGE SLAT TRACK #6 LOWER AFT ATTACH BOLT. REPLACED ATTCH BOLT PER AMM 27-84-64-400-002-A.Sep 28, 2019 · N185UW · Airbus A321211 · Leading Edge DevicesSDR AALA2019100199022Battery · no testAIRCRAFT WAS NOT GROUNDED: EMERGENCY POWER SUPPLY UNIT 12WL BATTERY FAILED EMERGENCY POWER SUPPLY UNIT SYSTEM TEST IN REFERENCE WITH JOB CARD 26L00005005. MAINTENANCE REPLACED BATTERY PER AMM 33-51-38.Sep 28, 2019 · N193UW · Airbus A321211 · Emergency LightingSDR AALA201909279014Megaphone · inoperativeAIRCRAFT NOT GROUNDED: AFT CABIN MEGAPHONE INOPERATIVE. REMOVED AND REPLACED AFT CABIN MEGAPHONE, AS REQUIRED. OPS CHECK GOOD.Sep 27, 2019 · N157UW · Airbus A321211 · Emergency EquipmentSDR AALA201909309004Epsu · faultyAIRCRAFT NOT GROUNDED: MAINTENANCE REPORTS EMERGENCY LIGHT SYS TEST AT PTP PANEL FAULTS 14WL EPSU. MAINTENANCE REPLACED EPSU & BAT 14WL IAW AMM 33-51-38. OPS CHECK OK.Sep 27, 2019 · N176UW · Airbus A321211 · Emergency LightingSDR AALA201910169018Floor Panel · delaminatedAIRCRAFT IN BASE MAINTENANCE: PASSENGER CABIN FLOOR PANEL 241JF DELAMINATED. REPLACED FLOOR PANEL PER SRM 53-02-00-300-011.Sep 26, 2019 · N185UW · Airbus A321211 · Fuselage Floor PanelSDR AALA201910169017Floor Panel · delaminatedAIRCRAFT IN BASE MAINTENANCE: AFT WET AREA FLOOR PANEL 261BG DELAMINATED. REPLACED FLOOR PANEL PER SRM 53-02-00-300-011.Sep 26, 2019 · N185UW · Airbus A321211 · Fuselage Floor PanelSDR AALA201910049032Attach Bolt · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON RIGHT WING LEADING EDGE SLAT TRACK #2 MID FORWARD ATTACH BOLT BETWEEN RIB 3 AND RIB 4. REPLACED ATTACH BOLT PER AMM 27-84-63-400-002-A.Sep 26, 2019 · N184US · Airbus A321211 · Leading Edge DevicesSDR AALA201910049031Attach Bolt · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON RIGHT WING LEADING EDGE SLAT TRACK #2 UPPER AFT ATTACH BOLT. REPLACED BOLT PER AMM 27-84-63-400-001-A.Sep 26, 2019 · N184US · Airbus A321211 · Leading Edge DevicesSDR AALA201910049030Attach Bolt · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON RIGHT WING LEADING EDGE SLAT TRACK #2 UPPER FORWARD ATTACH BOLT BETWEEN RIB 3 AND RIB 4. REPLACED ATTACHED BOLT PER AMM 27-84-63-400-002-A.Sep 26, 2019 · N184US · Airbus A321211 · Leading Edge DevicesSDR F3LA201909300119Smoke Warning · activatedLP 1211147 ITEM 1 --- AVIONICS SMOKE DURING CLIMB- NO VISIBLE SMOKE . ECAM ONLY . AIR RETURN ATL . --- CORRCTIVE ACTION -- PLACED ON MEL 26-15-01A. CTRL# 1155117 DD 9-26-19Sep 26, 2019 · N722FR · Airbus A321211 · Smoke DetectionSDR AALA201909279003Pitot Line · cloggedAIRCRAFT WAS GROUNDED: PILOT ABORTED TAKE OFF AT HIGH SPEED ON ACCOUNT OF CAPTAIN'S AIRSPEED INDICATOR FAILED. FLIGHT TAXIED TO THE GATE. MAINTENANCE FLUSHED CAPT PITOT LINE IAW AMM 34-10-001-700-1A AND PERFORMED LEAK TEST OF MAIN AIR DATA SYSTEM IAW AMM 34-1Sep 26, 2019 · N195UW · Airbus A321211 · Pitot/Static SystemSDR AALA201909269003Light · damagedAIRCRAFT WAS NOT GROUNDED: EMERGENCY SEAT MOUNTED LIGHT WAS DAMAGED AT SEAT 16C. MAINTENANCE REPLACED EMERGENCY LIGHT ASSEMBLY PER AMM 33-51-19.Sep 25, 2019 · N151UW · Airbus A321211 · Emergency LightingSDR AALA201909269002Light · damagedAIRCRAFT WAS NOT GROUNDED: EMERGENCY SEAT MOUNTED LIGHT WAS DAMAGED AT SEAT 10C. MAINTENANCE REPLACED EMERGENCY LIGHT ASSEMBLY PER AMM 33-51-19.Sep 25, 2019 · N151UW · Airbus A321211 · Emergency LightingSDR AALA201909279010Skin · delaminatedAIRCRAFT IN BASE MAINTENANCE: RUDDER LEFT HAND SURFACE SKIN PREVIOUS REPAIR DELAMINATED / DEBONDED AT RUDDER SATION 389 AND RIB 9. REPAIRED RUDDER SKIN PER SRM 55-41-13-300-024 AND EA 298584.Sep 23, 2019 · N153UW · Airbus A321211 · Rudder, Plate/SkinSDR DALA2019092305524Cover · brokenSEAT 36C EMERGENCY PATH LIGHT BROKEN OFF, REPLACED PATH LIGHTING COVER.Sep 22, 2019 · N331DN · Airbus A321211 · Emergency LightingSDR AALA201909239015Pin · out of positionAIRCRAFT NOT GROUNDED: MAINTENANCE REPORTS EMERGENCY LIGHTS ON LOWER PORTION OF BINS AT L2 AND L3 DOOR INOP. ACCOMPLISHED EA 298670. L2 AND L3 EMERGENCY LIGHTS PINNING CORRECTED AND OPS CHECKED GOOD.Sep 22, 2019 · N162UW · Airbus A321211 · Light System WiringSDR AALA201909239021Computer · malfunctionedAIRCRAFT WAS GROUNDED: PILOT REJECTED TAKEOFF AT 100 KNOTS DUE TO THE AUTO THROTTLE INOPERATIVE DURING TAKE OFF. MAINTENANCE PERFORMED RESET OF FMGC'S 1 & 2 , FCU 1 & 2 AND LMP CHECK IAW AMM 22-97-00. OPS CHECKS GOOD.Sep 22, 2019 · N193UW · Airbus A321211 · Auto Throttle SystemSDR AALA201909239018Bleed Air Sys · low pressureAIRCRAFT WAS GROUNDED: FLIGHT RETURNED TO SFO ON ACCOUNT OF NUMBER ONE BLEED LOW PRESSURE RESULTING IN A PACK PROBLEM. AN EMERGENCY WAS DECLARED. MAINTENANCE INSPECTED SENSE LINES AND PERFORMED OPERATIONAL CHECK ON NR 1 ENGINE BLEED AIR SYSTEM IAW AMM 36-11-00Sep 21, 2019 · N178US · Airbus A321211 · Pneumatic Distribution SystemSDR AALA201909239010Slide · low pressureAIRCRAFT WAS NOT GROUNDED: DOOR 1R SLIDE PRESSURE INDICATED LOW ON CIDS PANEL. MAINTENANCE PERFORMED SATISFACTORY OPERATIONAL CHECK PER AMM 25-62-44.Sep 21, 2019 · N194UW · Airbus A321211 · Escape SlideSDR AALA201909219011Spar · crackedAIRCRAFT IN BASE MAINTENANCE: #2 ENGINE PYLON SPAR CRACKED AT PYLON STATION 518 AND RIB 6. REPAIRED SPAR PER EA 294527.Sep 20, 2019 · N183UW · Airbus A321211 · Nacelle/Pylon, Frame/Spar/RibSDR AALA201909209002Pin · bentAIRCRAFT WAS NOT GROUNDED: OVERHEAD EMERGENCY EXIT LIGHT IN ISLE FAILED TO LIGHT. MAINTENANCE FOUND BENT GROUND PIN ON CONNECTOR AND STRAIGHTENED OUT PIN AND RECONNECTED AND PERFORMED SATSFACTORY OPERATIONAL CHECK.Sep 19, 2019 · N172US · Airbus A321211 · Light System WiringSDR DALA2019091805435Light · inoperativeFC CLOSET, RED PATH LIGHT INOP, INSTALLED NEW RED PATH LIGHT.Sep 18, 2019 · N338DN · Airbus A321211 · Emergency LightingSDR AALA201909199016Lubrication Unit · low pressureAIRCRAFT WAS GROUNDED: FLIGHT RETURNED TO DEN ON ACCOUNT OF APU SHUTDOWN WITH 1 GENERATOR ON PLACARD. EMERGENCY WAS DECLARED. MAINTENANCE REPLACED OIL LUBE MODULE IAW AMM 49-91-45, LEAK CHECK AND OPS CHECK NORMAL.Sep 18, 2019 · N165US · Airbus A321211 · APU Oil SystemSDR AALA201909199004Powerpack · faultedAIRCRAFT WAS NOT GROUNDED: EMERGENCY LIGHT POWER PACK 10WL FAULTED. MAINTENANCE REPLACED POWER PACK PER 33-51-38.Sep 18, 2019 · N176UW · Airbus A321211 · Emergency LightingSDR AALA201909189018Sense Line · leakingAIRCRAFT WAS GROUNDED: FLIGHT RETURNED TO PHL ON ACCOUNT OF NUMBER TWO ENGINE BLEED AND PACK FAILED. AN EMERGENCY WAS DECLARED. MAINTENANCE REPLACED SENSE LINE BETWEEN BLEED PRESSURE REGULATOR VALVE AND PYLON INTERFACE IAW AMM TASK 36-11-49. ENGINE 2 BLEED SYSSep 17, 2019 · N154UW · Airbus A321211 · Pneumatic Indicating System
Back to Airbus A321-211