Airbus A321-211
Service difficulty reports · 12,330
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A321211' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A321211' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR USAA2014100300004Damper · low pressureREPORTED THE L1 DOOR DAMPER LOW. SERVICED L1 DOOR DAMPER IAW AMM TASK 52-22-00-614-002.SDR USAA2014100300002Smoke Detector · unserviceableTHE AFT LEFT LAVATORY SMOKE DETECTOR CAME BACK ON. REPLACED AFT LAVATORY D SMOKE DETECTOR IAW AMM 26-17-15-400-001-A. OPERATIONAL TESTED IAW AMM 26-17-00-710-001-A GOOD.SDR USAA2014100300001Filter · unserviceableREFERENCING PREVIOUS WRITE UP, CREW REPORTED THE AFT LAVATORY SMOKE ALARM WENT OFF AGAIN. REPLACED ALL LAVATORY SMOKE DETECTOR FILTERS, FOUR, AS REQUIRED. SYS TESTED NORMAL. OK FOR SERVICE.SDR USAA2014100300006Smoke Detector · false activationCREW REPORTED LAVATORY D SMOKE ALARM WENT OFF. ACCOMPLISHED OPERATIONAL TEST IAW AMM 26-17-00-710-001-A. OPERATIONS CHECKED NORMAL. ACFT OK FOR CONTINUED SERVICE.SDR USAA2014100200004Cylinder · low pressureTHE EMER EXIT DOOR 3L DOOR ASSIST CYLINDER PRESS IS LOW. SERVICED EXIT DOOR ASSIST CYLINDER AS REQUIRED AT 3L IAW AMM 52-22-00 PB0301.SDR USAA2014100200003Fan · faultyCREW RECEIVED A VENT EXTRACT FAULT ACCOMPANIED BY CB AVIONICS VENT FAN POPPED & ELEC ODOR IN FLIGHT DECK & FWD CABIN. REPLACED EXTRACT FAN IAW AMM 21-26-51-000-001A. SYS OPERATIONS CHECKED SATISFACTORY.SDR USAA2014100100005Ptu · unserviceableHYDRAULIC SYS YELLOW OVERHEAT EN ROUTE. DECLARED AN EMER INBD TO INSURE PRIORITY HANDLING. FLIGHT LANDED WITHOUT INCIDENT. TROUBLE SHOT IAW TSM 29-13-00-810-802-A & TSM 29-23-00-810-801-A. R & R PTU. R & R RELAY 3816G, 6MJ2, 3811GX & SYS PRESS SWITCH 3151SDR USAA2014100200007Floor Panel · delaminatedFLOOR BY LAVATORY SL FLEXES WHEN WALKING ACROSS IT. CTR FLOOR PANEL BETWEEN FRAME 42 & 47, Y254 & -Y254 WAS FOUND TO HAVE AN 8 INCH X 8 INCH AREA OF DELAMINATION & WAS REPLACED IAW AMM 53-23-12.SDR USAA2014092900016Battery · dischargedTHE CABIN FLASHLIGHT REPORTED INOPERATIVE. R & R FLASHLIGHT BATTERY. OK FOR SERVICE.SDR USAA2014092900015Cylinder · low pressureTHE 2R DOOR SHOWING LOW SLIDE PRESS ON CIDS PANEL. SERVICED 2R DOOR EMER CYLINDER ACCUMULATOR PRESS IAW AMM 52-10-00-614-001.SDR USAA2014092900004Battery · dischargedTHE AFT EMER FLASHLIGHT STATUS LIGHT NOT BLINKING. REPLACED BATTERY. LIGHT OPERATIONS CHECKED OK. ACFT OK FOR SERVICE.SDR USAA2014092900003Connector · unsecureDURING FLIGHT CREW REPORTED RUNAWAY HEAT. MAXIMUM FWD TRIM TEMP GOT TO 152 & COCKPIT TEMP REACHED 102. FLIGHT DIVERTED & LANDED WITHOUT INCIDENT. FOUND LOOSE CONNECTOR ON LT INLET ACTUATOR. SECURED CONNECTOR. ACFT OK FOR SERVICE.SDR USAA2014092900009Seal · leakingWITH APU ON BOTH ENGS SHUTDOWN, APPROX 20 MINUTES IN LINE, CABIN & COCKPIT FILLED WITH POSSIBLE TOXIC FUMES, DIRTY SOCK SMELL. CAPTAIN NOTICED IRRITATION OF THROAT & BRONCHIA. ACFT RETURNED TO THE GATE. COMPLIED WITH JOB CARD 26L00021001 & 26L00021002. DETESDR USAA2014092600008Coffeemaker · unserviceableFWD & AFT ODOR OF A BURNING SMELL EN ROUTE & DURING DESCENT. R & R AFT COFFEEMAKERS & FOUND FOOD DEBRIS IN FWD GALLEY OVEN. REMOVED SHELVES & CLEANED INSIDE OVEN. NO ODOR PRESENT DURING TESTING.SDR USAA2014092900008Apu · odorA STRONG MOLD ODOR STARTING AT ROWS 26 & AFT. TROUBLE SHOT IAW JOB CARD 26L00021001 & 26L00021002. VERIFIED APU IS AT FAULT. ACFT PLACED ON MEL 49-10-01A. RAN APU, LT & RT PACKS FOR ONE HOUR. INSPECTED FOR LEAKS, NONE FOUND & NO ODOR DETECTED. THIS CLEARSDR USAA2014092600003Battery · dischargedTHE MID LT & RT EMER LIGHTS FAILED. R & R MID LT & RT EMER LIGHT BATTERIES IAW AMM 33-51-00. OPERATIONS CHECKED GOOD.SDR USAA2014092600001Power Supply · faultedMID CABIN POWER SUPPLY FAULT ON TEST. R & R POWER SUPPLY IAW AMM 33-51-38. OPERATIONS CHECKED GOOD.SDR USAA2014092400001Power Supply · faultyEMERGENCY LIGHT TEST DOES NOT PASS. R & R MID CABIN EPSU, LT SIDE 15WL IAW AMM 33-51-38-000-001-A & 33-51-38-400-001-A. R & R BATTERY IAW AMM 33-51-38-000-002-A & 33-51-38-400-002-A. OPERATIONS OK. ACFT OK FOR SERVICE.SDR USAA2014092300003Battery · dischargedTHE AFT RT FLASHLIGHT INOPERATIVE. R & R BATTERY AT AFT JUMP SEAT FLASHLIGHT, ACFT RT. OPERATIONS CHECKED GOOD.SDR USAA2014092200002Smoke Detector · faultyA LAVATORY SMOKE DETECTION FAULT. LAVATORY D FAULTED ON CIDS. REPLACED IAW AMM 26-17-15-000-008-A & 26-17-15-400-007-A. ACFT OK FOR SERVICE.SDR USAA2014092200007Knob · missingMEGA PHONE AT ROW 1 MISSING KNOB. REPLACED MEGA PHONE AT FWD STATION.SDR USAA2014091700003Girt Bar · lack of lubeCREW REPORTED THAT 4R DOOR IS DIFFICULT TO DISARM. CLEANED & LUBED FLOOR HOOKS & GIRT BAR.SDR USAA2014091600002Lens · missingRED LENS CAP MISSING AT SEAT 9D, EMER EXIT LENS. REPLACED RED LENS COVER AT SEAT 9D.SDR USAA2014091600001Pin · missingTHE R2 DOOR DISARM HANDLE LOOSE & MISSING PIN. REPLACED MISSING PIN & SECURED GRIP PLATE FOR DOOR R2 DISARM HANDLE.SDR USAA2014091500021Knob · detachedTHE WINDOW BLIND IN 1R DOOR IS STUCK & KNOB CAME OFF. REPAIRED WINDOW BLIND IN 1R DOOR & INSTALLED NEW KNOB.SDR USAA2014091500020Bottle · low pressureTHE L1 DOOR ASSIST & DAMPER ACTUATOR BOTTLE WITH LOW PSI 300. SERVICED L1 DOOR ACTUATOR IAW AMM 52-10-00-614-001.SDR USAA2014091500019Pin · missingTHE LT L2 DOOR DISARM HANDLE LOOSE & MISSING PIN. INSTALLED PIN AS NEEDED.SDR USAA2014091100008Bottle · low pressureCREW RECEIVED A CIDS CAUTION MSG ON FLIGHT ATTENDANT PANEL. SERVICED 2R DOOR ASSIST BOTTLE IAW AMM 52-10-00-614-001-A.SDR USAA2014091100007Cover · missingTHE LIGHT FOR EMER AISLE PATH FLOOR LIGHTING AT SEAT 1C IS MISSING COVER. REPLACED LIGHT ASSEMBLY AT SEAT 1C FOR FLOOR PATH LIGHTING. OPERATIONS CHECKED GOOD.SDR USAA2014091000001Control Unit · faultyRECEIVED ECAM MSG SMOKE LAVATORY DET FAULT, FWD CARGO DET FAULT & AFT CARGO DET FAULT. COMPLIED WITH TSM SUPPLEMENT 26-16-00-201. R & R SDCU 10WQ IAW AMM 26-17-34-400-001A. R & R FWD CARGO DETECTOR 2 WH, LAVATORY A & D SMOKE DETECTORS IAW AMM 26-17-15-400-0SDR USAA2014091200001Seal · leakingEXCESSIVE R4 DOOR ASSIST BOTTLE SERVICING, TECHNICAL SERVICE ITEM. PERFORMED LEAK CHECK OF R4 EMER OPERATION CYLINDER IAW AMM 52-10-00-790-001A & FOUND FILLING VLV LEAKING AT BASE. R & R FILLING VLV SEAL & CLEANED DEBRIS FROM VLV BASE AREA. RECHARGED CYLINDSDR USAA2014090900006Mechanism · dirtyDOOR 4R TOUGH TO DISARM BY CABIN CREW. INSPECTED DOOR 4R ARMING MECHANISM. CLEANED AREA AS NEEDED. DOOR 4R ARMING MECHANISM, OPERATIONS NORMAL AT THIS TIME.SDR USAA2014090900005Lens · damagedTHE L1 LENS COVER ABOVE DOOR DAMAGED, EEPL. R & R LENS COVER IAW AMM 33-51-11, PB 401.SDR USAA2014090900004Bottle · low pressureDOOR SLIDE 4R INDICATES DISARMED ON FLIGHT ATTENDANTS CIDS PANEL, BUT INDICATES ARMED ON DOOR & ECAM DOOR PAGE. FLIGHT ATTENDANT REPORT TO CAPTAIN WAS INCORRECT. CIDS SHOWS DOOR ASSIST BOTTLE. LEAK CHECKED BOTTLE, NONE FOUND. SERVICED BOTTLE IAW AMM 52-10-SDR USAA2014090800017Accumulator · lowHOLDING SHORT OF RUNWAY, UTILIZED PARKING BRAKE, WITH PARKING BRAKE AT THE ON POSITION, NO PRESS WAS INDICATED & ACFT ROLLED FWD. FLIGHT RETURNED TO THE GATE. CYCLED ANTI-SKID SWITCH. SERVICED BRAKE ACCUMULATOR AS REQUIRED. PERFORMED SATISFACTORY BITE TEST SDR USAA2014090800016Cover · missingTHE EMER LIGHT COVER MISSING AT L1 DOOR. R & R L1 DOOR EMER LIGHT COVER IAW AMM 33-51-00.SDR USAA2014090800007Damper · low pressureDOOR 2R DAMPER PRESS AT 1600 PSI. SERVICED DOOR 2R DAMPER IAW AMM 52-10-00-614-001-A.SDR USAA2014090800029Floor Panel · delaminatedRON FWD CARGO PANEL 131AF FOUND DAMAGED WITH A 13 INCH W X 11 INCH L UPPER SURFACE DELAMINATED. R & R PANEL IAW AMM 53-22-14 PB 0401.SDR USAA2014090800015Bottle · low pressureCREW RECEIVED A RED CIDS LIGHT ON FWD FLIGHT ATTENDANT PANEL. L2 DOOR ASSIST BOTTLE LOW. SERVICED L2 DOOR ASSIST BOTTLE. OPERATIONS CHECKED GOOD.SDR USAA2014090400004Lens · missingCREW REPORTED THE LENS ON FLOOR EMER LIGHT AT LAVATORY D BULKHEAD MISSING. REPLACED LENS.SDR USAA2014090300006Lens · missing3C PROX LIGHT LENS COVER MISSING. REPLACED 3C PROX LIGHT ASSEMBLY. OPERATIONS CHECKED NORMAL.SDR USAA2014090300005Battery · dischargedDURING PREFLIGHT, CREW FOUND INBD EMER FLASHLIGHT UNDER FLIGHT ATTENDANT JUMP SEAT NOT FLASHING. REPLACED EMER FLASHLIGHT BATTERY. OPERATIONS NORMAL IAW AAM 20-25-00.SDR USAA2014090300004Lens · missingREPORTED 1C EMER WHITE LIGHT LENS COVER MISSING. REPLACED MISSING LENS. OPERATIONS CHECKED GOOD.SDR USAA2014090200004Bottle · low pressureTHE R4 DOOR ASSIST BOTTLE PRESS LOW. SERVICED R4 DOOR ASSIST BOTTLE IAW AMM 52-10-00-614-001A.SDR USAA2014090200020Bottle · low pressureDOOR 2R SHOWS DISARMED ON FLIGHT ATTENDANT PANEL WHILE ARMED ECAM SHOWS CORRECTLY. FOUND DOOR 2R BOTTLE PRESS LOW. SERVICED BOTTLE IAW TASK 52-10-00-614-001-A. CLEARED THE MSG, ACFT OK FOR SERVICE.SDR USAA2014082800002Smoke Detector · faultedCREW REPORTED A SMOKE DETECTOR FAULT. REPLACED SDCU FOR TROUBLESHOOTING. REPLACED LAVATORY SMOKE DETECTORS 5WQ & 4WH. OPERATIONS CHECKED SATISFACTORY IAW AMM 26-17-34, 26-16-15 & 26-17-15.SDR USAA2014082500016Lens · missing4L EMER LIGHT COVER MISSING. REPLACED 4L DOOR EMER LIGHT LENS COVER.SDR USAA2014082500017Lens · missingEMERGENCY PLASTIC LIGHT COVER MISSING AT SEAT 1C. INSTALLED EMER LIGHT COVER ON SEAT 1C.SDR USAA2014082500015Lens · brokenAISLE EMER LIGHT COVER ON SEAT 23C BROKEN. INSTALLED EMER LIGHT COVER AT SEAT 23C IAW AMM 33-51-19-400-001-A.SDR USAA2014082500014Bottle · low pressureR4 DOOR ASSIST BOTTLE NEEDS SERVICED. SERVICED R4 DOOR ASSIST BOTTLE IAW AMM 52-10-00-614-001A.
Back to Airbus A321-211