Airbus A321-231
Service difficulty reports · 20,710
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A321231' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A321231' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA201707259008Feeder Cable · damagedROWS 35 AND 36 SEAT MOUNTED EMERGENCY LIGHT INOPERATIVE. INSTALLED A NEW POWER CABLE HARNESS ASSEMBLY IAW AIPC 33-51-09-37K. ACCOMPLISHED SATISFACTORY LIGHT TEST IAW AMM 33-51-00.SDR YENA201707220594Actuator · failedLEFT WING TANK OVERFLOW ON ECAM WITH 1600 LBS OF FUEL LOSS AFTER 50 MIN IN FLIGHT FLIGHT DIVERTED. R & R THE LT FUEL CONTROL VALVE ACTUATOR 11QL IAW AMM 28-26-51. OPS CHECKED GOOD.SDR AALA201707259001Unknown · odorAIRCRAFT WAS NOT GROUNDED. REQUEST FOR MAINTENANCE TO CHECK THERMAL BLANKETS IN FORWARD CARGO. FLIGHT ATTENDANTS COMPLAINED OF HOT FLOOR AND WIRED SMELL NEAR 1-L JUMPSEAT. MAINTENANCE TO TROUBLESHOOT FLOOR HEATING SYSTEM PER AMM 25-27-00-740-001-A. ACCOMPLISHESDR AALA201707269001Cover · brokenAIRCRAFT WAS NOT GROUNDED. SEAT MOUNTED EXIT LIGHT COVER AT 11 LEFT, BROKEN. REPLACED SEAT MOUNTED EXIT LIGHT AT 11L PER AMM 33-51-19.SDR AALA201707249010Cylinder · low pressureDURING A PS2 CHECK, FOUND THE R1 DOOR EMERGENCY CYLINDER PRESSURE LOW. SERVICED THE R1 DOOR CYLINDER TO CORRECT PRESSURE IAW AMM 52-10-00. ACCOMPLISHED SATISFACTORY OPERATIONAL CHECK.SDR AALA20170722002Battery Pack · no testEMERGENCY POWER SUPPLY UNIT BATTERY 11WL FAILED TO TEST. REPLACED EMERGENCY POWER SUPPLY BATTERY PACK IAW AMM 33-51-00. ACCOMPLISHED SATISFACTORY OPERATIONAL CHECK.SDR AALA201707269023Bottle · low pressureAIRCRAFT WAS NOT GROUNDED. DOOR 4R SAYS CHECK PRESSURE. MAINTENANCE SERVICED DOOR ASSIST BOTTLE AT 4R DOOR PER AMM 52-10-00. ACCOMPLISHED SATISFACTORY OPERATIONAL CHECK.SDR AALA201707269022Arming Lever · looseAIRCRAFT WAS NOT GROUNDED. 2R ARMING LEVER IS LOOSE. MAINTENANCE TIGHTENED LOOSE HARDWARE AND ACCOMPLISHED SATISFACTORY OPERATIONAL CHECK.SDR AALA201707269021Lens · missingAIRCRAFT WAS NOT GROUNDED. 4L DOOR EMERGENCY LIGHT COVER MISSING. MAINTENANCE REPLACED EXIT LIGHT LENS AND ACCOMPLISHED SATISFACTORY OPERATIONAL CHECK.SDR AALA201707269019Lens · missingAIRCRAFT WAS NOT GROUNDED. 4R EMERGENCY EXIT LIGHT COVER, MISSING. MAINTENANCE REPLACED EXIT LIGHT LENS COVER AT R4 DOOR AND ACCOMPLISHED SATISFACTORY OPERATIONAL CHECK.SDR AALA201707269018Lens · missingAIRCRAFT WAS NOT GROUNDED. SEAT 3 LEFT EMERGENCY LIGHT LENS MISSING. REPLACED LED LIGHT ASSEMBLY PER AMM 33-51-19. ACCOMPLISHED SATISFACTORY OPERATIONAL CHECK.SDR YENA201707210596Filter · failedDURING DESCENT THROUGH 11,800 FT, IDLE THURST, A STRONG DISTINCT TOXIC ODOR IN COCKPIT AND CABIN FRONT AND REAR. THE FLIGHT CREW DONNED OXYGEN MASKS. REMOVED AND REPLACED THE NR 1 AND 2 OZONE FILTERS IAW AMM 21-51-41.SDR YENA201707210595Filter · odorDURING DESCENT THROUGH 11,800 FT, IDLE THURST, A STRONG DISTINCT TOXIC ODOR IN COCKPIT AND CABIN FRONT AND REAR. THE FLIGHT CREW DONNED OXYGEN MASKS. ACFT IS OK FOR SERVICE. REMOVED AND REPLACED NR 1 AND 2 OZONE FILTERS IAW AMM 21-51-41.SDR AALA201707249039Lens · missingR3 DOOR EMERGENCY EXIT LIGHT MISSING THE LENS. REPLACED R3 DOOR EMERGENCY EXIT LIGHT IAW AMM 33-51-13.SDR AALA201707249038Lens · missingR2 DOOR EMERGENCY EXIT LIGHT MISSING THE LENS. REPLACED R2 DOOR EMERGENCY EXIT LIGHT IAW AMM 33-51-13.SDR AALA201707249009Lens · missingR1 DOOR EMERGENCY EXIT LIGHTS MISSING THE LENS. REPLACED THE EMERGENCY LIGHT IAW AMM 33-51-13.SDR AALA201707249001Floor Panel · delaminatedDELAMINATION ON AFT CARGO FLOOR PANEL 151LF. REPLACED AFT CARGO FLOOR PANEL IAW AMM 53-42-14.SDR AALA201707249018Fire Bottle · faultedECAM DISPLAYS CARGO FIRE EXTINGUISHER BOTTLE 1 AFT CARGO BOTTLE FAULT. OVERHEAD PANEL SMOKE PANEL INDICATES FORWARD DISCHARGE, AFT DISCHARGE. REPLACED FORWARD CARGO FIRE-EXTINGUISHER BOTTLE IAW AMM 26-23-41. ACCOMPLISHED SATISFACTORY OPS CHECK, NO FAULTS NOTESDR AALA201707249007Survival Kit · missingSURVIVAL KIT RAFT IN REAR RIGHT SIDE OVERHEAD BIN, MISSING SNAP HOOK ON FRONT OF SERVICE KIT. REPLACED SURVIVAL KIT ASSEMBLY.SDR AALA201707249006Cylinder · low pressureL1 DOOR DAMPER CYLINDER PRESSURE LOW. SERVICED THE L1 DOOR CYLINDER IAW AMM 52-10-00-614-001.SDR GTIA2017072002101Slide · deployedR4 DOOR SLIDE/RAFT DEPLOYED. REMOVED R4 DOOR SLIDE/RAFT IAW AMM 25-62-44.SDR AALA201707249031Lens · brokenL1 DOOR EMERGENCY EXIT SIGN LENS BROKEN. REPLACED EMERGENCY LIGHT LENS IAW AMM 33-51-13.SDR AALA201707249017Light · brokenBROKEN R1 DOOR EMERGENCY EXIT LIGHT ASSEMBLY. REPLACED LIGHT ASSEMBLY PER MM 33-51-13. ACCOMPLISHED SATISFACTORY OPERATIONAL CHECK.SDR AALA201707249005Light · brokenL4 DOOR EMERGENCY LIGHT BROKEN. REPLACED EMERGENCY LIGHT IAW AMM 33-51-13.SDR AALA201707249004Lens · brokenR1 DOOR EMERGENCY EXIT SIGN LENS BROKEN. REPLACED THE LENS IAW AMM 33-51-13.SDR AALA20170721001Light · brokenBROKEN L4 DOOR EMERGENCY EXIT LIGHT ASSEMBLY. REPLACED LIGHT ASSEMBLY IAW MM 33-51-13. ACCOMPLISHED SATISFACTORY OPERATIONAL CHECK.SDR AALA201707219001Floor Panel · damagedFORWARD GALLEY FLOOR COVERING DAMAGED NEAR THE R1 DOOR, FLOOR IS SOFT. MAINTENANCE REPLACED FLOOR PANEL 222EF IAW AMM 53-12-12-401.SDR AALA201707219011Lens · missingFOUND OVERHEAD EMERGENCY LIGHT 209WL MISSING LENS. REPLACED OVERHEAD EMERGENCY LIGHT IAW AMM 33-51-11.SDR AALA201707209020Battery · no testEMERGENCY POWER SUPPLY UNIT BATTERY FAULT INDICATED AT 10WL. REPLACED BATTERY IAW AMM 33-51-00.SDR AALA201707209013Damper · low pressureFOUND THE L3 DOOR DAMPER LOW PRESSURE, THE PRESSURE WAS IN RED BAND. SERVICED DAMPER TO GREEN BAND IAW AMM 52-22-00.SDR AALA20170720002Accumulator · low pressureR4 DOOR ACCUMULATOR PRESSURE IS LOW, SERVICED ACCUMULATO IAW AMM 52-10-00.SDR AALA20170720001Accumulator · low pressureR1 DOOR ACCUMULATOR PRESSURE IS LOW. SERVICED DOOR ACCUMULATOR IAW AMM 52-10-00.SDR AALA201707209024Cylinder · low pressureL2 DOOR EMERGENCY CYLINDER ACCUMULATOR BELOW PRESSURE LIMITS. SERVICED L2 DOOR EMERGENCY CYLINDER IAW MM 52-10-00. ACCOMPLISHED SATISFACTORY OPERATIONAL CHECK.SDR AALA201707209023Cylinder · low pressureR1 DOOR EMERGENCY CYLINDER ACCUMULATOR BELOW PRESSURE LIMIT. SERVICED THE R1 DOOR CYLINDER IAW MM 52-10-00. ACCOMPLISHED SATISFACTORY OPERATIONAL CHECK.SDR AALA201707209015Cylinder · low pressureR2 DOOR EMERGENCY CYLINDER ACCUMULATOR, BELOW PRESSURE LIMITS. SERVICED R2 DOOR CYLINDER IAW MM 52-10-00. ACCOMPLISHED SATISFACTORY OPERATIONAL CHECK.SDR AALA201707209008Accumulator · low pressureR2 EMERGENCY EXIT DOOR DAMPNER ACCUMULATOR, LOW PRESSURE. CHARGED EMERGENCY EXIT DOOR ACCUMULATOR IAW 52-22-00.SDR AALA201707209003Bottle · low pressureL4 EMERGENCY CYLINDER HAD LOW PRESSURE. CHARGED THE DOOR BOTTLE IAW 52-10-00.SDR GTIA2017071902093Bottle · low pressureDURING WEEKLY CHECK, FOUND R3 DOOR ASSIST BOTTLE REQUIRES SERVICING. SERVICED R3 DOOR ASSIST BOTTLE TO SERVICEABLE LIMITS IAW AMM 52-22-00. LEAK CHECKED GOOD.SDR GTIA2017071902092Bottle · low pressureDURING WEEKLY CHECK, FOUND R1 DOOR ASSIST BOTTLE REQUIRES SERVICING.. SERVICED R1 DOOR ASSIST BOTTLE TO SERVICEABLE LIMITS IAW AMM 52-10-00. LEAK CHECKED GOOD.SDR GTIA2017071902091Bottle · low pressureFOUND R1 DOOR ASSIST BOTTLE PRESSURE LOW DURING WEEKLY INSPECTION. SERVICED THE R1 DOOR ASSIST BOTTLE TO SERVICEABLE LIMITS IAW AMM 52-10-00.SDR AALA201707249016Light · brokenBROKEN R4 DOOR EMERGENCY EXIT LIGHT ASSEMBLY. REPLACED LIGHT ASSEMBLY PER MM 33-51-13. ACCOMPLISHED SATISFACTORY OPERATIONAL CHECK.SDR AALA201707209022Sign · detachedR1 DOOR EMERGENCY EXIT SIGN LOWER FASTENER LIBERATED FROM SIGN. REPLACED EXIT SIGN IAW AMM 33-51-13.SDR AALA201707209014Cylinder · low pressureR1 DOOR EMERGENCY CYLINDER HAS LOW PRESSURE. SERVICED R1 DOOR EMERGENCY CYLINDER IAW AMM 52-10-00.SDR AALA201707199019Floor Panel · delaminatedDELAMINATION ON AFT CARGO BAY FLOOR PANEL 151CF FORWARD OF THE DOOR. REPLACED FLOOR PANEL IAW AMM 53-42-14-400.SDR GTIA2017071802089Bottle · low pressureL1 DOOR ASSIST PRESSURE LOW . SERVICED L1 DOOR ASSIST BOTTLE IAW AMM 52-10-00SDR GTIA2017071802088Flashlight · inoperativeAFT F/A EMERGENCY FLASHLIGHT INOPERATIVE. SECURED THE FLASHLIGHT IAW AMM 25-65-00. OPS CHECKED GOOD. ACFT OK FOR SERVICE.SDR AALA201707199022Cylinder · low pressureR4 DOOR SHOWS CHECK SLIDE PRESSURE ON FLIGHT ATTENDANT DOOR PANEL. SERVICED THE R4 DOOR ASSIST BOTTLE TO PROPER PRESS IAW AMM.SDR AALA20170719003Battery Pack · failedAIRCRAFT WAS NOT GROUNDED. EMERGENCY POWER SUPPLY UNIT SYSTEM TEST FAILS BATTERY PACKS AT 10WL. REPLACED BATTERY PACK 10WL PER AMM 33-51-38. ACCOMPLISHED SATISFACTORY OPERATIONAL CHECK.SDR AALA20170719002Cylinder · low pressureAIRCRAFT WAS NOT GROUNDED. L3 DOOR DAMPER CYLINDER PRESSURE LOW. SERVICED DAMPER CYLINDER PER AMM 52-10-00.SDR AALA20170719001Cylinder · low pressureAIRCRAFT WAS NOT GROUNDED. R1 DOOR EMERGENCY CYLINDER / ACCUMULATOR HAS LOW PRESSURE. SERVICED CYLINDER PER AMM 52-10-00.
Back to Airbus A321-231