SDR USAA2014030400003Reservoir · defectiveCIDS PANEL INDICATION DOOR 3R PRESS INOPERATIVE. REPLACED DOOR 3R ESCAPE SLIDE RESERVOIR IAW AMM 25-62-49-401.SDR USAA2014030300022Tube · leakingEXTREME CABIN ODOR DURING START & CLIMB, PAX & CREW COMPLAINED OF ODOR & FELT LIGHT HEADED & NAUSEOUS. FOUND APU TO BE SOURCE OF ODOR. REPLACED LEAKING APU OIL COOLER TRANSFER TUBE IAW AMM 49-91-44-400-802-A. REPLACED APU OIL LUBE MODULE IAW AMM 49-91-4SDR AALA20140228007Cids · malfunctionedLAX CREW REPORTED EMERGENCY LIGHTS OVER EXIT DOORS ILLUMINATED DURING DESCENT. FLIGHT LANDED LAX WITHOUT INCIDENT. ACCOMPLISHED RESET OF CABIN INTERCOMMUNICATION DATA SYS. SYS GND CHECKED NORMAL OPERATION CLOSED.SDR USAA2014030300023Damper · low pressure2L DOOR WHITE PRESS LIGHT ILLUMINATED. SERVICED DOOR DAMPER ASSIST BOTTLE IAW AMM 52-10-00-614-001-A. NO LEAKS DETECTED.SDR USAA2014022800004Connector · brokenMECHANIC REPORT, EMERGENCY LIGHT HARNESS AT SEAT ROW 29 LH HAS A BROKEN CONNECTOR. REPLACED BROKEN WIRE HARNESS WITH NEW HARNESS AS REQUIRED.SDR USAA2014022700002Floor Panel · delaminatedPILOT REPORT, DELAMINATION ON CABIN FLOOR PANEL 221DF AT FR 17A, BL 0. REPLACED CABIN FLOOR PANEL 221DF IAW A321 AMM 53-12-12-400-001-A.SDR USAA2014022700003Bottle · low pressurePREPARING FOR PUSH BACK, FLIGHT ATTENDANT REPORTED AFTER ALL DOORS ARMED, CIDS PANEL INDICATED LOW DOOR PRESS ON 2L DOOR. SERVICED 2L DOOR ASSIST BOTTLE IAW AMM 25-02-49-040, OK FOR SERVICE.SDR USAA2014022700004Autopilot Sys · malfunctionedAT CRUISE AILERON FIRST OFFICER PFD INDICATION 40 LT OFF COURSE, LATER CHANGING TO 9R OFF COURSE. WHILE CAPT PFD SHOWED ON COURSE, FIRST OFFICER FLIGHT DIRECTOR COMMANDING A RT TURN CHANGING TO A LT TURN WITH AUTO PILOT 1 ENGAGED. CROSS CHECKED WITH A VOR SHSDR USAA2014022600004Unknown · odorUPON INITIALLY BOARDING ACFT, FLIGHT ATTENDANT REPORTED CABIN ODOR IN REAR SECTION AFTER APU START & APU BLEED. FLIGHT ATTENDANT EXPERIENCED THROAT IRRITATION. COMPLIED WITH JOB CARD 26L00021001, COULD NOT DUPLICATE ODOR.SDR USAA2014022500001Computer · defectiveTHROTTLE RUN AWAY WHEN AUTO PILOT 1 ENGAGED ON SHORT FINAL. REPLACED FMGC 2 IAW AMM 22-83-34-400-001-C. PERFORMED SATISFACTORY CAT LAND CHECK IAW JC 26T00022001. A SECOND EVENT OCCURRED FEB 26 WITH AUTO FLT AUTO THRUST OFF, ECAM INTERMITTENT. HISTORY HAS SSDR USAA2014022400010Wire · brokenRED EMERGENCY EXIT LIGHT AT 10C INOPERATIVE. REPAIRED BROKEN WIRE, CHECKED EMERGENCY LIGHT AT 10C, OPERATIONS GOOD.SDR USAA2014022400012Floor Panel · delaminatedREGULAR OVERNIGHT VISIT, DELAMINATION ON FLOOR PANEL 221DF BETWEEN FRAME 16 TO FRAME 20, STRINGER 23R, -Y 254. REPLACED FLOOR PANEL 221DF IAW AMM 53-12-12-400-001-A.SDR USAA2014022400011Floor Panel · debondedREGULAR OVERNIGHT VISIT DIS-BOND ON FLOOR PANEL 222EF BETWEEN FRAME 16 TO FRAME 20, STRINGER 23R, -Y 1292. REPLACED FLOOR PANEL 222EF IAW AMM 53-12-12-400-001-A.SDR USAA2014022400007Girt Bar · dirtyFLIGHT ATTENDANT REPORTS 4R DOOR HARD TO ARM & DISARM. CLEANED DEBRIS FROM GIRT BAR AREA, OPERATIONS GOOD.SDR USAA2014022100004Engine · stalledDURING CLIMB OUT THROUGH 5000 FT, TOGA, BLEED OFF, FELT & HEARD A JOLT FROM NR 2 ENGINE. NR 2 ENGINE EGT OVERLIMIT, PEGGED INTO RED, & NR 2 ENGINE STALLED. RETARDED THRUST TO IDLE & EGT GRADUALLY DROPPED BACK INTO GREEN. IMMEDIATE RETURN TO DEPARTURE, AND SDR USAA2014022100003Light · missingEMERGENCY PATHWAY LIGHT BY SEAT 4C MISSING. SECURED EMERGENCY LIGHT ASSEMBLY AT SEAT 4C. ACCOMPLISHED OPERATIONS CHECK IAW AMM 33-51-00-710-009-A, CHECKED GOOD.SDR GTIA201402161176Stowage Box · inoperativeNR 2 OBSERVER OXYGEN MASK INOPERATIVE. R & R NR 2 OBSERVER OXYGEN MASK IAW AMM. NO HELP. R & R NR 2 OBSERVER OXYGEN MASK STOWAGE BOX IAW AMM. OPS & LEAK CK GOOD.SDR USAA2014021700016Bottle · low pressure2L DOOR ASSIST BOTTLE LOW PRESS. SERVICED 2L DOOR ASSIST BOTTLE IAW A321AMM 52-10-00-614-001-A.SDR GTIA201402151173Oxygen Mask · unwanted deployOXYGEN MASKS DROPPED ON LANDING, SEATS 9ABC AND 14. PERFORMED MANUAL DROP CHECK OF PAX OXYGEN MASK IAW AMM 35-23-00-710-001. ALL CHECKS GOOD.SDR GTIA201402141168Knob · missingFWD MEGAPHONE VOLUME KNOB MISSING. R & R MEGAPHONE KNOB IAW CMM. OPS CHECKED GOOD.SDR USAA2014021700018Bottle · low pressure2L DOOR ASSIST BOTTLE LOW PRESS. SERVICED 2L DOOR ASSIST DAMPER IAW AMM 52-22-000614-002-A.SDR USAA2014021700017Fire Bottle · unserviceable3L FIRE EXTINGUISHER MISSING SAFETY WIRE. REPLACED FIRE EXTINGUISHER WITH SERVICEABLE UNIT.SDR USAA2014021700015Light · inoperativeEMERGENCY LIGHT AT SEATS 3A & 3C INOPERATIVE. REPLACED EMERGENCY LIGHT ASSEMBLY AT SEATS 3A & 3C IAW A321 AMM 33-51-19. OPERATIONS CHECKED GOOD.SDR USAA2014021100007Smoke Detector · false activationDURING INITIAL DESCENT RECEIVED ECAM MSG LAVATORY SMOKE. NO INDICATION OF SMOKE OR SMELL OF SMOKE IN ANY OF THE LAVATORIES. PERFORMED LAVATORY SMOKE DETECTOR TEST IAW A321 AMM 26-17-00 ALL TESTS PASSED.SDR USAA2014021000012Lever · looseARM & DISARM LEVER DOOR 2L IS LOOSE. TIGHTENED ARM & DISARM LEVER DOOR 2L.SDR USAA2014021000011Connector · unsecureROW 10 LT EMERGENCY LIGHT INOPERATIVE. SECURED CONNECTOR 7261VC3 FOR ROW 10 LT EMERGENCY LIGHT.SDR USAA2014021000009Lens · missingEMERGENCY EXIT SIGN LENS AT R4 DOOR MISSING. REPLACED EMERGENCY EXIT SIGN LENS AT R4 DOOR.SDR USAA2014021000008Bottle · low pressureR1 DOOR ASSIST BOTTLE PRESS LOW. SERVICED R1 DOOR ASSIST BOTTLE IAW AMM 52-10-00.SDR USAA2014020700001Lever · brokenDOOR 2L ARMING LEVER IS BROKEN OFF. REPLACED DOOR 2L ARMING LEVER IAW CMM 52-21-30, SYS OPERATIONS CHECKED GOOD.SDR USAA2014020500006Floor Panel · damagedPILOT REPORT SOFT FLOOR BOARD PANEL 221DF BETWEEN FS 806 TO FS 810 & BETWEEN STRINGER 10L TO STRINGER 10R. REPLACED FLOOR PANEL 221DF IAW AMM 53-12-12.SDR USAA2014020500002Battery · dischargedFORWARD MEGA PHONE INOPERATIVE. REPLACED FWD MEGA PHONE BATTERIES.SDR USAA2014020500001Brake Assy · overheatedABORTED TAKEOFF AT MIA FOR HOT BRAKE ON BOTH RT BRAKES 3 & 4. AUTO BRAKE CAUSED A PUFF OF SMOKE NOTICED BY THE TOWER, INFO BRAKES COOLED TO NORMAL WITH BRAKE FANS ON. ACCOMPLISHED POST FLT REVIEW, ACCOMPLISHED A321 TSM 34-42-00-810-922-A. INSPECTED RT MLG BSDR USAA2014020400001Lens · missingDOOR R4 EMERGENCY EXIT LIGHT LENS MISSING. REPLACED DOOR R4 EMERGENCY EXIT LIGHT LENS.SDR USAA2014020400002Lens · missingROW 1C MISSING EMERGENCY EXIT LIGHT CLEAR LENS. REPLACED EMERGENCY EXIT LIGHT CLEAR LENS AT ROW 1C.SDR USAA2014020300030Unknown · fumesINBOUND CREW REPORTED TOXIC FUMES ON BOARD, DIRTY SOCK SMELL, FLIGHT ATTENDANT TAKEN TO HOSPITAL. PERFORMED CABIN AIR QUALITY JOB CARD 26L00021001, NO 30 DAY HISTORY. DUTY MGR NOTIFIED OF RESULTS. NFF ACFT OK FOR SERVICE.SDR USAA2014020300024Lens · brokenEXIT SIGN LENS AT DOOR 4R HAS A BROKEN RETAINING CLIP. REPLACED EXIT SIGN LENS AT DOOR 4R.SDR USAA2014020300001Sense Line · leakingDURING CLIMB NR 2 ENG BLEED FAULT. RECYCLED BLEED IAW MOC, FAULT RECURRED. FOUND PRV SENSE LINE LEAKING ON NR 2 ENG. INSTALLED NEW SENSE LINE. PERFORMED OPERATIONS TEST OF BLEED AIR SYS IAW AMM 36-11-00-710-003-A.SDR USAA2014013100002O-Ring · damagedDURING DESCENT FROM 12,000 FEET, CREW REPORTED A VERY STRONG DIRTY SOCK SMELL DEVELOPED. THE SMELL DISSIPATED AT ABOUT 3,000 FEET. COMPLIED WITH JOB CARDS 26L00021001 & 26L00021002. FOUND FUEL & OIL LEAKING FROM APU FUEL CONTROL UNIT TO BE SOURCE OF SMELL GSDR GTIA201401291142Bypass Valve · failedLANDING GEAR, NOSEWHEEL, DOORS WOULD NOT CLOSE AFTER CYCLED ON TAKE OFF. FOLLOWED TSM 37-31-00-810-859-A. R & R BYPASS VALVE NLG DOOR GROUND OPENING IAW AMM 32-22-17, PB 401. OPS CHECK GOOD. PERFORMED EXTENSION AND RETRACTION ON NOSE GEAR AND DOORS. OPS CHSDR USAA2014012900002Latch · lack of lubeDOOR 1L GIRT BAR LATCH STUCK. LUBED DOOR 1L GIRT BAR LATCH, OPERATIONS CHECKED SATISFACTORY IAW AMM 52-11-00-501-00-820-001A.SDR USAA2014012800012Lens · detachedEMERGENCY EXIT LIGHT LENS AT ROW 4 RT IS DETACHED. REPLACED EMERGENCY EXIT LIGHT LENS AT ROW 4 RT.SDR USAA2014012800006Floor Panel · damagedSOFT SPOT AT CTR OF AFT GALLEY FLOORBOARD 261DF BETWEEN FRAME 66 TO FRAME 68. REPLACED FLOOR PANEL 261DF IAW AMM 53-42-12-400-002A.SDR USAA2014012700011Latch · dirtyDOOR L1 GIRT BAR LATCH STUCK. CLEANED & LUBED DOOR L1 LATCH.SDR USAA2014012700006Adiru · faultedDURING CLIMB OUT HAD ECAM NR 3 ADIRU FAULT. RETURNED TO PHL FOR PRECAUTIONARY LANDING. LANDED IN DIRECT LAW WITHOUT INCIDENT. REPLACED NR 3 ADIRU IAW AMM 32-12-34-000-001A.SDR USAA2014012700005Oil System · overservicedDIRTY SOCK ODOR BEGAN DURING OR JUST AFTER NR 1 ENG START, NR 2 ENG NOT RUNNING. USING APU BLEED & CONTINUED THROUGH TAXI, TAKE OFF & CLIMB. ODOR DISSIPATED AFTER LEVEL OFF AT CRUISE, FL300, APPROXIMATELY 20 MIN AFTER TAKEOFF. APU WAS SHUT DOWN AFTER ENG 2 SDR USAA2014012400014Placard · missingEXIT PLACARD AT ROW 4 RT MISSING. INSTALLED EXIT PLACARD AT ROW 4 RT.SDR USAA2014012400006Floor Panel · delaminatedPILOT REPORT DELAMINATION ON CABIN CTR AISLE FLOOR BETWEEN FRAME 47 TO FRAME 47.5, BL0. REPLACED CABIN CTR AISLE FLOOR BETWEEN FRAME 47 TO FRAME 47.5, BL0 IAW AMM 53-42-12.SDR USAA2014012200002Lens · missingEMERGENCY EXIT SIGN PLASTIC LENS AT DOOR 4R MISSING. INSTALLED EMERGENCY EXIT SIGN LENS AT DOOR 4R.SDR GTIA201401211127Battery Pack · inoperativeCIDS NR 1, EPSU SYS TEST FAILED. R & R BATTERY PACK. OPS CHECKED GOOD IAW AMM.SDR GTIA201401211126Battery Pack · inoperativeCIDS NR 1 EPSU SYS TEST FAILED, EPSU MID RT. R & R BATTERY PACK. OPS CHECKED GOOD IAW AMM.
Back to Airbus A321-231