Airbus A321-231
Service difficulty reports · 20,710
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A321231' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A321231' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR USAA2013070300011Cylinder · low pressureCIDS CAUTION LIGHT ON. FOUND DOOR L2 DOOR ASSIST BOTTLE LOW. SERVICED DOOR DAMPER CYLINDER IAW AMM 52-10-00-0301.SDR USAA2013070200011Lens · missingPASSENGER SEAT 1C EMERGENCY EXIT LIGHT LENS COVER MISSING. REPLACED EMERGENCY EXIT LIGHT ASSEMBLY AT PASSENGER SEAT 1C.SDR USAA2013070200010Lens · missingEMERGENCY EXIT LIGHT LENS AFT OF DOOR 4R IS MISSING. INSTALLED SERVICEABLE EMERGENCY LIGHT LENS AT DOOR 4R.SDR USAA2013062500014Floor Panel · damagedFLIGHT 27. SOFT MUSHY FLOOR PANEL FR16 TO FR20 AND BL0 TO RBL 20 AT FORWARD GALLEY (R1 DOOR). R & R FLOOR PANEL IAW AMM 53-12-12-400-001A.SDR USAA2013062500006Cover · missingF/A REPORTS EMERGENCY EXIT LIGHT COVER AT DOOR 4R MISSING. REPLACED EMERGENCY EXIT LIGHT COVER AT DOOR 4R.SDR USAA2013062700007Actuator · low pressureF/A PANEL DOOR PRESS INDICATOR INOPERATIVE. SERVICED DOOR 3R ACTUATOR IAW AMM 52-22-00614-002.SDR USAA2013062400010Light · brokenEMERGENCY EXIT LIGHT AT SEAT 4C BROKEN. REPLACED BROKEN EMERGENCY EXIT LIGHT AT SEAT 4C.SDR USAA2013062400011Unknown · smokeF/A SMELLED AN ELECTRICAL ODOR AND SAW SMOKE IN FORWARD GALLEY. DURING TROUBLESHOOTING, CIRCUIT BREAKER "GALLEY CONTROLLER" S-28 TRIPPED. REPLACED FWD GALLEY CHILLER IAW AMM 25-34-51-401. VENDOR COULD NOT CONFIRM FAILURE. CHILLER CAME BACK NO FAULT FOUND.SDR USAA2013062400012Battery · dischargedFLASHLIGHT AT POSITION 4R INOPERATIVE. MX R & R FLASHLIGHT BATTERY.SDR USAA2013062400006Reservoir · inoperativeF/A CONTROL PANEL MESSAGE "CHECK SLIDE PRESSURE 3L" NOT READING ON GROUND. REMOVED AND REPLACED DOOR 3L SLIDE BOTTLE IAW MM 25-62-49. VENDOR TEARDOWN CONFIRMED FAILURE OF THE RESERVOIR.SDR GTIA20130621354Web · corrodedDURING INSPECTION, CORROSION WAS FOUND ON LT PYLON FRONT UPPER SPAR WEB, DUE TO WATER CONDENSATION AND DEBRIS IN DRAIN FILLING. CORROSION REMOVED IAW EO 5451-1301 AND RDAS 70578644/003/2013.SDR GTIA20130621353Skin · corrodedLEFT WING UPPER WING SKIN LOWER T/E SURFACE CORRODED AT SPOILER NR 3 INBD ACTUATOR FITTING.SDR GTIA20130621355Skin · corrodedDURING INSPECTION, CORROSION WAS FOUND ON THE LOWER SURFACE OF TOP SKIN PANEL 2 AT THE T/E OVERHANG, IN BETWEEN THE INNER JACK RIB 7A ON THE RT WING. CORROSION REMOVED IAW EO 5750-1304 & RDAS 70578617/003/2013.SDR GTIA20130621356Angle · corrodedDURING INSPECTION, CORROSION WAS FOUND ON ANGLE D575-59087-200 OF T/E RIBLET AT WMRX 7176,6875 ON THE LT WING. CORROSION REMOVED IAW EO 5750-1305 & RDAS.SDR USAA2013062000005Lens · missingDOOR 4L EMERGENCY LIGHT LENS COVER MISSING. REPLACED DOOR 4L EMERGENCY LIGHT LENS COVER.SDR USAA2013061700019O-Ring · damagedNOTICED A NOXIOUS ODOR IN CABIN DURING VERY HEAVY RAIN AND HAIL WITH PACKS ON APU BLEED AIR. SMELL WAS THROUGHOUT CABIN AND COCKPIT. ODOR WAS OILY DIRTY SOCK SMELL. TURNED OFF APU BLEED TO PACKS AND ODOR DISSAPATED. R & R O-RINGS ON APU GENERATOR RECEPTACLESDR USAA2013061300030Cylinder · low pressureFOUND R-4 DOOR PRESSURE IN YELLOW ZONE DURING WEEKLY CHECK. SERVICED BOTTLE TO GREEN ZONE IAW MM 52-10-00-614-001.SDR USAA2013061200025Light · damagedEMERGENCY LIGHT AT SEAT 4 AC DAMAGED. INSTALLED NEW EMERGENCY LIGHT AT SEAT 4 AC.SDR USAA2013061200024Unknown · odorPASSENGERS IN LAST ROW AND AFT GALLEY COMPLAINED OF DIRTY/MUSTY ODOR. 6 PASSENGERS AND 3 F/A`S EXPERIENCED DIZZINESS/NAUSEA AND 1 F/A ALMOST FAINTED. ACCOMPLISHED TROUBLESHOOTING, AIR QUALITY JOB CARDS, FOUND AFT LAVATORIES TO BE SOURCE OF ODOR. ACCOMPLISHED SDR USAA2013061100003Reservoir · low pressureDURING TAXI OUT, RECEIVED A DOOR R3 LOW PRESSURE LIGHT WITH THE PRESSURE GAUGE READING RT ON THE LINE BETWEEN GREEN AND RED. R & R R3 DOOR INFLATION RESERVOIR IAW MM 25-62-49-400-001-A.SDR GTIA20130606343Battery Pack · no testEPSU 11WL, BATTERY FAILED, OPS CHECK. R & R EPSU BATTERY AT 11WL IAW ACFT MM. OP’S CHECKED GOOD.SDR GTIA20130621352Container · failedDURING MANUAL O2 GENERATOR DROP TEST ROW 23 LT DID NOT OPEN. R & R 02 CONTAINER IAW AMM.SDR GTIA20130621351Door · deactivatedON ARRIVAL, DISCOVERED R1 DOOR ASSISIT BOTTLE IN THE DISARMED POSITION. R1 DOOR ASSIT BOTTLE ARMED IAW AMM.SDR USAA2013060500010Sign · brokenEMERGENCY EXIT SIGN AT 4L DOOR BROKEN. REPLACED EMERGENCY EXIT SIGN AT 4L DOOR.SDR USAA2013060300017Lens · brokenAFT LEFT EMERGENCY EXIT LIGHT COVER BROKEN. REPLACED AFT LEFT EMERGENCY EXIT LIGHT.SDR USAA2013060300016Wire · brokenEMERGENCY EXIT LIGHT AT SEAT 10 ABC DOES NOT ILLUMINATE. FOUND BROKEN WIRE AT CONNECTOR. REPAIRED CONNECTION.SDR USAA2013060300015Battery Pack · dischargedBATTERY PACK ON EMERGENCY LIGHT ASSY WILL NOT HOLD CHARGE. R & R BATTERY PACK ON EMERGENCY LIGHT ASSY.SDR USAA2013060300014Light · inoperative20L EMERGENCY LIGHT INOPERATIVE. EMERGENCY LIGHT COVER MISSING AT SEAT 27L. FOUND CONNECTOR UNDER SEAT DISCONNECTED AT SEAT 20L. RECONNECTED CONNECTOR AT SEAT 20L. REPLACED EMERGENCY LIGHT ASSY AT SEAT 27L.SDR GTIA20130529636Oxygen Mask · unwanted deployO2 MASK COMPARTMENT OPENED AND MASKS DEPLOYED ABOVE L1 F/A JUMPSEAT. OPENED COMPARTMENT, STOWED MASK, CLOSED COMPARTMENT, PERFORMED DROP CK OF CABIN O2 MASKS IAW AMM 35-23-00-710-001-A. OPS CK GOOD.SDR USAA2013053000016Floor Panel · debondedPILOT REPORT-2 AREAS OF DISBOND ON FLOOR PANEL AT FR16+18" BETWEEN Y540 & Y760. REPLACED FLOOR PANEL AT FR16+18" BETWEEN -Y540 & -Y760 IAW AMM 53-12-12.SDR USAA2013053000011Floor Panel · debondedPILOT REPORT -AREA OF DISBOND ON FLOOR PANEL TOP SKIN AT FR16+20", Y560. REPLACED FLOOR PANEL AT FR16+20", Y560 IAW AMM 53-12-12.SDR USAA2013053000008Gust Lock · dirtyGUST LOCK ON DOOR R1 INOPERATIVE. CLEANED GUST LOCK RELEASE SWITCH.SDR USAA2013070300014Floorboard · damagedPILOT REPORT - FLOOR MAKING CRACKING NOISE AT ROW 18 AISLE AT BS22962 BETWEEN Y10 TO -Y10. REPLACED DAMAGED CABIN FLOORBOARD WITH NEW FLOORBOARD AT BS22962 BETWEEN Y10 TO -Y10 IAW AMM 53-22-12, PB 401.SDR USAA2013052900007Cover · missingEMERGENCY LIGHT COVER ON SEAT 3-C MISSING. R & R SEAT 3-C EMERGENCY LIGHT IAW AMM 33-51-19.SDR USAA2013052900004Lens · brokenEMERGENCY EXIT SIGN BROKEN AT DOOR 1L. REPLACED EMERGENCY EXIT LIGHT LENS COVER AT 1L DOOR.SDR USAA2013052900003Light · missingEMERGENCY EXIT LIGHT MISSING AT DOOR 4R AT FLOOR LEVEL. REPLACED EMERGENCY EXIT LIGHT AT DOOR 4R.SDR USAA2013052800011Lens · missingDOOR 4L EXIT LIGHT MISSING COVER. REPLACED DOOR 4L EXIT LIGHT COVER.SDR USAA2013052800010Lens · missingLENS COVER MISSING ON LOWER EMERGENCY EXIT LIGHT DOOR 1R. INSTALLED LENS COVER ON LOWER EMERGENCY EXIT LIGHT AT DOOR 1R.SDR USAA2013052200005Bottle · low pressureF/A REPORTS DOOR 3R CHECK PRESSURE AMBER LIGHT ON. DOOR WAS ARMED. R & R R3 DOOR SLIDE BOTTLE IAW MM 25-62-49-0401-A.SDR GTIA20130519618Lever · looseR3 DOOR ARMING LEVER IS LOOSE. SECURED ARMING LEVER IAW ACFT MM, OK FOR SERVICE.SDR USAA2013052000007Cover · missingL4 DOOR LOW LEVEL EXIT SIGN LIGHT COVER MISSING. INSTALLED EXIT LIGHT COVER AT 4L.SDR GTIA20130517616Battery Pack · inoperativeAFTER OPS TEST OF THE EMERGENCY LIGHTS FOR R1 DOOR SLIDE CHANGE, HAD BAT/EPSU MID LT & RT FAULT. R & R MID EPSU BATTERIES IAW ACFT MM, OPS CHECKED GOOD.SDR USAA2013051400003Bottle · low pressureDURING POST FLIGHT, L4 DOOR AFT BOTTLE HAS LOW PRESSURE. SERVICED L4 DOOR DAMPER AND EMERGENCY OPERATION CYLINDER.SDR GTIA20130511598Button · brokenDURING PREFLIGHT F/A FOUND FRONT MEGAPHONE VOLUME BUTTON MISSING. INSTALLED NEW VOLUME BUTTOM ON THE FRONT MEGAPHONE.SDR USAA2013051300014Floor Panel · delaminatedRON VISIT - DELAMINATION ON FLOOR PANEL 151LF BETWEEN FR56 TO FR58 & BETWEEN -Y1732 TO Y1732. REPLACED FLOOR PANEL 151LF IAW A321 AMM 53-42-14.SDR USAA2013051300013Floor Panel · delaminatedRON VISIT - DELAMINATION ON FLOOR PANEL 151GF BETWEEN FR52 TO FR56 & BETWEEN -Y1732 TO Y1732. REPLACED FLOOR PANEL 151GF IAW A321 AMM 53-42-04.SDR USAA2013050900006Light · brokenEMERGENCY LIGHT AT SEAT 1C BROKEN. REPLACED EMERGENCY LIGHT AT SEAT 1C.SDR USAA2013050700005Light · damaged4L SEAT MOUNTED EMERGENCY LIGHT DAMAGED. REPLACED 4L SEAT MOUNTED EMERGENCY LIGHT IN ACCORDANCE WITH AIRBUS MAINTENANCE MANUAL 33-51-19.SDR USAA2013050200015Light · brokenAISLE SEAT 1C EMERGENCY LIGHT BROKEN. REPLACED EMERGENCY LIGHT AT SEAT 1C.SDR USAA2013043000008Proximity Sensor · failedSLIDE AT 2L DOOR WILL NOT ARM. REMOVED AND REPLACED PROXIMITY SENSOR 5WN1 AT DOOR 2L.
Back to Airbus A321-231