Airbus A330-243
Service difficulty reports · 5,645
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A330243' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A330243' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR USAA2013100800001Battery · inoperativeOTBD EMERGENCY FLASHLIGHT AT DOOR 1L HAS A DEAD BATTERY AND BROKEN SEAL. REPLACED BATTERY AND SEAL.SDR HALA2013100700124Engine · making metalNR 2 ENGINE OIL CHIP DETECTED, ILLUMINATED AFTER TOUCHDOWN. REMOVED NR 2 ENGINE IAW 7100-9401-02. INSTALLED NR 2 ENGINE IAW TASK CARD 7100-9401-02.SDR USAA2013100700003Lens · missingGALLEY EMERGENCY LIGHT LENS MISSING MID GALLEY WALL. INSTALLED LENS, OPS CHECKED NORMAL.SDR USAA2013100700002Cylinder · low pressureL2 DOOR PRESSURE LOW AT DEPARTURE. SERVICED L2 DOOR PRESSURE. OPS AND INDICATIONS NOW NORMAL.SDR CA131007019Tube · leaking(CAN) HYDRAULIC GREEN SYSTEM LEAK DETECTED BY ECAM IN FLIGHT, FLUID QTY DECREASING. QRH PROCEDURES WAS CARRIED OUT AND ENGINE DRIVEN HYDRAULIC PUMP WAS SELECTED OFF FOR THE REMAINDER OF THE FLIGHT. ACFT LANDING WAS UNEVENTFUL AND ACFT TOWED OFF THE RUNWAY DUESDR USAA2013093000002Bottle · low pressureON CIDS PANEL, L4 DOOR HAS AMBER CAUTION "CHECK DOOR PRESSURE". MX SERVICE DOOR ASSIST BOTTLE.SDR USAA2013092400001Cylinder · low pressureSIDS PANEL DISPLAY LOW PRESSURE R3 DOOR. MX SERVICED DOOR PRESSURE TO CORRECT PRESSURE, OK FOR SERVICE.SDR USAA2013092300005Sign · missingL3 EXIT SIGN MISSING. MX REPLACED EXIT SIGN AS REQUIRED.SDR USAA2013092300002Cover · detached3L DOOR EXIT SIGN COVER FELL OFF. MX INSTALLED EXIT SIGN COVER ON 3L DOOR. OK FOR SERVICE.SDR USAA2013092000001Cover · looseL2 DOOR EMERGENCY LIGHT COVER WILL NOT REMAIN ATTACHED. MX REINSTALLED EMERGENCY LIGHT COVER. OPS CHECKED GOOD.SDR USAA2013091900001Bottle · low pressureR4 DOOR ASSIST BOTTLE PRESSURE LOW. MX SERVICED ASSIST BOTTLE.SDR HALA2013091700119Windshield · failedAPPROXIMATELY 1.5 HRS INTO THE FLT ECAM MESSAGE A. "ICE RT WINDSHIELD HEAT". SIMULTANEOUSLY WITH APPEARENT SHORT OF RT WINDSHIELD, BLACK MARK WITH DELAMINATION LAYER BELOW. R & R F/O WINDSHIELD IAW AMM 30-42-34, OPS CHECKED GOOD.SDR HALA2013091700118Windshield · failedAPPROX 1.5 HRS INTO THE FLIGHT, ECAM MESSAGE A ICE RT WINDSHIELD HEAT. SIMULTANTOUSLLY WITH APPEARENT SHORT OF RT WINDSHIELD, BLACK MARK WITH DELAMINATING LAYER BELOW. R & R F/O WINDSHIELD IAW AMM 30-42-34, OPS CHECKED GOOD.SDR ANCF2013080700165Line · leakingECAM MESSAGE OF FUEL LEAK FOB DISCREPANCY. IAW TSM 28-46-00-810-861- A RT ENG FUEL TUBE BETWEEN AND HP PUMP INLET CONNECTION WAS FOUND WITH CHECK CRACK IAW AMM 73-12-41, PB 401, CONF 22 THE FUEL TUBE BETWEEN F/O HE AND HP PUMP INLET CONNECTION WAS REPLACED IASDR USAA2013091300001Oven · odorCIRCUIT BREAKERS WERE PULLED ON OVENS, DUE TO A PLASTIC OR ELECTRICAL ODOR. MX R & R THE OVEN AT 6 -11.SDR USAA2013090900005Lens · missingLAVATORY DOOR LOWER RT SIDE EMERGENCY LIGHT LENS MISSING. MC REPLACED MISSING LENS.SDR USAA2013090500001Lens · missingLENS MISSING FROM FLOOR ESCAPE PATH MARKING LIGHTS AT LAV L53 FWD AND AFT CORNERS, LAV 54 AND LAV 74. MX INSTALLED LENS ON ESCAPE PATH LIGHTS AT LAVS L53, L54 & L74.SDR ANCF2013080700164Wave Guide · malfunctionedDURING FLIGHT WEATHER RADAR INOPERATIVE. THE WAVE GUIDE SECTION WAS REPLACED TEST SATISFACTORY IAW AMM 34-41-41 PB 40-1.SDR USAA2013090400001Slide · no testL3 SLIDE FAILED OPS CHECKED, SLIDE JAMMED DOOR PART OPENED. MX R & R L3 DOOR SLIDE/RAFT PACK ASSY.SDR USAA2013082900001Flashlight · inoperativeEMERGENCY FLASHLIGHT AT 3R, F/A STATION, INOPERATIVE. MAINTENANCE R & R EMERGENCY FLASHLIGHT AT SEAT 3R F/A STATION.SDR USAA2013082600001Windshield · crackedF/O'S EXTERIOR WINDSHIELD CRACKED IN FLIGHT AT FL400 AT APPROX 30W. ALSO ACCOMPANIED BY ECAM ANTI-ICE RT WINDSHIELD HEAT. F/O WINDSHIELD BEGAN ARCHING. WHC2 RESET BREAKER PULLED. MX REPLACED F/O WINDSHIELD AND ALSO WINDOW HEAT CONTROLLER.SDR USAA2013082100001Lens · missingEMERGENCY ESCAPE PATH LIGHT AT LAV L53 AFT END MISSING LENS. MX INSTALLED L53 AFT EMERGENCY LIGHT LENS.SDR USAA2013081900012Floor Panel · delaminatedAREA OF DELAMINATION ON HEATED FLOOR PANEL 38DS AT R4 DOOR ENTRYWAY. REPLACED FLOOR PANEL 38DS IAW EA 105052.SDR USAA2013081900011Floor Panel · delaminatedAREA OF DELAMINATION ON HEATED FLOOR PANEL 112DS AT R4 DOOR ENTRYWAY. REPLACED FLOOR PANEL 112DS IAW EA 105052.SDR USAA2013081900010Floor Panel · delaminatedAREA OF DELAMINATION ON HEATED FLOOR PANEL 40DS AT R4 DOOR ENTRYWAY. REPLACED FLOOR PANEL 40DS IAW EA 105052.SDR USAA2013081900001Flashlight · inoperativeFLASHLIGHT AT L3 DOOR INOPERATIVE. MX REPLACED FLASHLIGHT. OPS CHECKED OK.SDR USAA2013081600005Connector · disconnectedEMERGENCY LIGHT SEAT 1H INOPERATIVE. MX INSTALLED ELECTRICAL CONNECTOR.SDR USAA2013081200001Cover · missingEMERGENCY EXIT LIGHT COVER MISSING. MX REPLACED COVER AS REQUIRED.SDR USAA2013080700003Cover · brokenLOWER RT SIDE PATH LIGHT COVER BROKEN BY LAVATORY (L-38). MX ADJUSTED EMERGENCY ESCAPE PATH LIGHT COVER. OPS CHECKED OK.SDR USAA2013080700002Cover · missingEMERGENCY LIGHT COVER MISSING. MX REINSTALLED EMERGENCY LIGHT COVER AT R2 DOOR,OK FOR SERVICE.SDR USAA2013080500001Lens · detachedEMERGENCY LIGHT AT L3 DOOR MISSING LENS. MX FOUND LENS UNDER SEAT. INSTALLED LENS, OPS CHECKED GOOD.SDR HALA2013080300098Fmu · faultedNR 1 ENG CONTROL SYS FAULT IN CRUISE. R & R NR 1 ENGINE FUEL METERING UNIT IAW AMM 73-21-52. OPS, LEAK AND SECURITY CHECKED GOOD, OK FOR SERVICE.SDR USAA2013080200002Cover · detachedR3 DOOR EMERGENCY LIGHT COVER DETACHED. MX SECURED COVER.SDR USAA2013073100003Lens · missingLAVATORY "L38" FLOOR LEVEL EMERGENCY LIGHT COVER MISSING. MX REPLACED LENS.SDR USAA2013073100002Bottle · low pressureR4 DOOR PRESSURE CHECK ON CIDS UPON GATE ARRIVAL. MX SERVICED DOOR.SDR USAA2013072900001Lens · brokenEMERGENCY LIGHT LENS BROKEN. MX REPLACED LENS.SDR USAA2013072200003Cover · detachedON BATHROOM WALL 3/R DOOR AREA, COVER FOR EMERGENCY LIGHT IS DETACHED. MX REPLACED COVER, OK FOR SERVICE.SDR USAA2013071600009Battery · faultyEPSU SYS TEST SHOWS FAULT ATA 33-51-00 BAT/ EPSU (18WL) DOOR 4. EPSU TEST SHOWS " BATT FAULT". MX REPLACED EPSU 18WL (DOOR R4) BATTERY.SDR HALA2013071300092Warning Light · false activationAIR PACK 1 OVERHEAT. RESET PACK CONTROL 1 & 2 AND ZONE TEMP CONT PERFORMED BITE SYS TEST OF ECS IAW 21-63-00-730-801, SYS TESTED OK WITH NO FAULTS, OPS CHECKED GOOD, OK FOR SERVICE.SDR USAA2013071500001Megaphone · inoperativeMEGAPHONE IN AFT LT STORAGE COMPARTMENT, THE TRIGGER MECHANISMIS INOP. MX REPLACED AFT LT STORAGE COMPARTMENT MEGAPHONE.SDR USAA2013070500028Service Panel · missingDURING WALK AROUND FOUND YELLOW HYD SERVICING PANEL MISSING. THE DISCREPANCY WAS DEFERRED VIA CDL 29-031. REPLACED THE YELLOW HYD SERVICING PANEL. SINCE THIS WAS THE SECOND EVENT ON THIS ACFT FOR THIS PANEL, AN ENGINEERING INVESTIGATION WAS CONDUCTED TO DETSDR USAA2013070100005Bottle · low pressure4R DOOR SHOWS LOW PRESSURE. MX SERVICED 4R DOOR.SDR USAA2013070100001Cylinder · low pressureFWD F/A CIDS PANEL DISPLAY "LOW PRESS" DOOR 4R. MX SERVICED DOOR DAMPER/EMERGENCY OPERATION CYLINDER 1783 PSI. NO LEAKS NOTED.SDR USAA2013070100004Lens · missingEMERGENCY EXIT LIGHT LENSE MISSING AT LAV 37 & 53. MX REPLACED MISSING EMERGENCY LIGHT LENS AT LAV'S 53 & 37.SDR USAA2013062600001Cover · missingEMERGENCY EXIT SIGN OVER 2L DOOR MISSING COVER. MX INSTALLED NEW SIGN COVER. OPS CHECKS OK.SDR USAA2013062500001Oven · overheatedOVEN 1 IN AFT GALLEY HAD AN OVERHEAT & BURNING SMELL. MX R & R NR 1 OVEN IN AFT GALLEY. OPS CHECK IS GOOD.SDR USAA2013062000001Cover · missingEXIT SIGN AT 3L OVERHEAD COVER FELL OFF. MX REPLACED MISSING EXIT SIGN.SDR USAA2013061900001Battery · discharged1A EMERGENCY FLASHLIGHT INOPERATIVE. MX R & R EMERGENCY FLASH LIGHT BATTERY.SDR ANCF2013042900160Monitor · failedAFTER TAKEOFF, IN SEAT 20J PASSENGER SCREEN BLANKED AND HAD SMOKE FOR 10 SECONDS. IAW AMM 23-33-08-000-801 AND AMM 23-33-08-400-801 THE MONITOR AT THE SEAT 20J WAS REPLACED.SDR HALA2013061400082Seal · tornATB LOSS OF HYD FLUID FROM GREEN SYS. FOUND NR 2 ENGINE SYS PULSATING DAMPER SEAL TORN. R & R SEAL IAW AMM 29-11-54-400-802. OPS AND LEAK CHECK GOOD. TSM 29-11-00 ACCOMPLISHED NO FAULTS NOTED. GREEN SYS CHECK IAW AMM 29-00-00, ACCOMPLISHED NO DEFECTS NOTED
Back to Airbus A330-243