SDR AALA202610279677Wire · brokenAIRCRAFT WAS NOT GROUNDED: ROW 25ABC WHITE EMERGENCY LIGHT INOPERATIVE - MAINTENANCE FOUND BROKEN WIRE AT CONNECTOR AND RE-TERMINATED WIRE - A SATISFACTORY OPERATIONAL CHECK WAS ACCOMPLISHEDSDR AALA202610270695Wire · brokenAIRCRAFT WAS NOT GROUNDED: ROW 24ABC RED EMERGENCY LIGHT INOPERATIVE - MAINTENANCE FOUND BROKEN WIRE AT CONNECTOR AND RE-TERMINATED WIRE - A SATISFACTORY OPERATIONAL CHECK WAS ACCOMPLISHEDSDR AALA202610271971Battery · no testAIRCRAFT WAS NOT GROUNDED: FLIGHT ATTENDANT SEAT BEHIND LAVATORY L EMERGENCY FLASHLIGHT BATTERY FOUND DEAD - MANTENANCE REPLACED BATTERY ON HANDHELD FLASHLIGHT AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK PER AMM 25-65-00SDR AALA202610273931Battery · no testAIRCRAFT WAS NOT GROUNDED: FOUND DEAD BATTERY ON FORWARD INBOARD FLIGHT ATTENDANT SEAT EMERGENCY FLASHLIGHT - MAINTENANCE REPLACED BATTERY ON HANDHELD FLASHLIGHT AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK PER AMM 25-65-00SDR YENA2026102600994Unknown · odorFLT 2725, JFK-TPA. ODOR EVENT PASSING THRU 10,000 INFLIGHT INFORMED CA @ 10000 FT OF A CHEMICAL ODOR IN AFT GALLEY, COMPLIED WITH INFORMATION NOTICE 2017-T015 STEP 1, ISOLATED FAULT TO TYPE 10 PER TSM 05-50-00-810-085-B/TSM 05-50-00-810-085-D. AIRCRAFT IS OK FSDR AALA202610267395Reservoir · low pressureAIRCRAFT WAS NOT GROUNDED: CIDS PANEL DISPLAYS CHECK DOOR PRESSURE IN AMBER NEXT TO THE 3R DOOR - MAINTENANCE SERVICED R3 DOOR SLIDE RESERVOIR TO PROPER LEVEL PER AMM 25-62-00SDR AALA202610263260Valve · leakingAIRCRAFT WAS GROUNDED: CIDS SHOWING CHECK 4R DOOR PRESSURE - MAINTENANCE REPLACED THE 4R DOOR DAMPER AND EMERGENCY OPERATION CYLINDER CHARGING VALVE PER AMM 52-10-00 WITH NO LEAKS OR ISSUES NOTEDSDR AALA202610267198Bottle · low pressureAIRCRAFT WAS NOT GROUNDED: CIDS PANEL 1R DOOR MESSAGES SHOWS AN AMBER DOOR DISARMED CHECK DOOR PRESSURE MESSAGE AFTER ARMING THE DOOR FOR DEPARTURE - MAINTENANCE SERVICED THE R1 DAMPER AND EMERGENCY OPERATION CYLINDER PER AMM 52-10-00SDR AALA202610262540Handle · looseAIRCRAFT WAS NOT GROUNDED: EXIT DOOR 2R HANDLE IS LOOSE - MAINTENANCE TIGHTENED NUT ON HANDLE AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK PER AMM 52-22-00SDR AALA202610261050Flashlight · not seatedAIRCRAFT WAS NOT GROUNDED: FLIGHT ATTENDANT JUMP SEAT CLOSEST TO DOOR 1L FLASHLIGHT BELOW SEAT WILL NOT TURN OFF - MAINTENANCE RE-SEATED THE FLASHLIGHT PER AMM 25-65-00SDR AALA202610267563Wire · brokenAIRCRAFT WAS NOT GROUNDED: SEAT 12C EMERGENCY PATHWAY LIGHT INOPERATIVE - MAINTENANCE FOUND THE SIDEWALL CONNECTOR WAS DAMAGED AND HAD A BROKEN WIRE - MAINTENANCE REPLACED THE CONNECTOR AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECKSDR AALA202610266050Elec Connector · disconnectedAIRCRAFT WAS NOT GROUNDED: SEAT 11C EMERGENCY PATHWAY LIGHT INOPERATIVE - MAINTENANCE FOUND SEAT EMERGENCY LIGHT CONNECTOR DISCONNECTED AND RE-CONNECTED IT - A SATISFACTORY OPERATIONAL CHECK WAS ACCOMPLISHEDSDR AALA202610268785Lock · inoperativeAIRCRAFT WAS NOT GROUNDED: 1L WILL NOT LOCK IN THE OPEN POSITION - MAINTENANCE LUBRICATED THE DOOR LOCK MECHANISM AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECKSDR AALA202610261478Brake · seizedAIRCRAFT WAS GROUNDED: FELT VIBRATION AFTER LANDING ALL THE WAY TO THE GATE - THE NUMBER 3 BRAKE WAS SHOWING 390 WHILE THE NUMBER 4 WAS SHOWING ONLY 40 - MORE POWER THAN USUAL WAS NEEDED TO TAXI - MAINTENANCE FOUND POSITION 3 BRAKE SEIZED AND DAMAGED RESULTINGSDR AALA202610266121Wire · brokenAIRCRAFT WAS GROUNDED: FLIGHT ATTENDANT PANEL INDICATES CHECK DOOR PRESSURE 1L - MAINTENANCE FOUND BROKEN WIRE AT CONNECTOR 360RH1A AND REPLACED THE CONNECTOR - A SATISFACTORY OPERATIONAL CHECK WAS ACCOMPLISHED WITH NO MESSAGES NOTEDSDR AALA202610264560Wire Harness · damagedAIRCRAFT WAS NOT GROUNDED: ROW 8 SEAT MOUNTED EMERGENCY LIGHT INOPERATIVE - MAINTENANCE FOUND HARNESS UNDER SEAT DAMAGED (OPEN)SDR AALA202610264699Slide Raft · fault messageAIRCRAFT IN BASE MAINTENANCE: FAULT MESSAGE DISPLAYED DURING EMERGENCY EXIT LIGHT TEST - MAINTENANCE REPLACED THE SLIDE RAFT ASSEMBLY FOR PASSENGER CREW DOOR 831 AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK OF THE MERGENCY LIGHTING SYSTEM WITH NO FAULTS SDR AALA202610234375Flashlight Assy · inoperativeAIRCRAFT WAS NOT GROUNDED: FLIGHT ATTENDANTS FORWARD EMERGENCY FLASHLIGHTS NOT POWERED AND TAPE NOT INTACT ON PREFLIGHT - MAINTENANCE REPLACED THE FLASHLIGHT ASSEMBLY AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK WITH NO ISSUES NOTEDSDR AALA202610238654Life Vest · openAIRCRAFT WAS NOT GROUNDED: CAPTAINS LIFE VEST HAS BEEN OPENED -MAINTENANCE REPLACED THE LIFE VEST PER AMM 25-66-52SDR AALA202610236963Arming Lever · looseAIRCRAFT WAS NOT GROUNDED: DOOR 2R ARMING LEVER LOOSE - MAINTENANCE SECURED ARMING LEVER ON 2R CABIN DOOR PER AMM 52-13-00SDR ERKR2026102200890Access Panel · corrodedFUEL TANK ACCESS PANEL 540HB HAS EVIDENCE OF CORROSION ON THE FASTENER HOLESSDR ERKR2026102200889Access Panel · corrodedFUEL TANK ACCESS PANEL 540NB HAS EVIDENCE OF CORROSION ON THE FASTENER HOLES.SDR 2026FA0000888Access Panel · corrodedFUEL TANK ACCESS PANEL 540QB HAS EVIDENCE OF CORROSION ON THE FASTENER HOLESSDR ERKR2026102200887Access Panel · corrodedFUEL TANK ACCESS PANEL 540KB HAS EVIDENCE OF CORROSION ON THE FASTENER HOLES.SDR ERKR2026FA0000886Access Panel · corrodedFUEL TANK ACCESS PANEL 540LB HAS EVIDENCE OF CORROSION ON THE FASTENER HOLES/SDR ERKR2026102200885Access Panel · corrodedPANEL RACK FUEL TANK ACCESS PANEL 540JB HAS EVIDENCE OF CORROSION ON THE FASTENER HOLES.SDR AALA202610267263Power Supply · fault messageAIRCRAFT IN BASE MAINTENANCE: EMERGENCY POWER SUPPLY UNIT 10WL BITE TEST SHOWS UNIT FAULT - REPLACED EMERGENCY POWER SUPPLY UNIT 10WL AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECKSDR AALA202610227748Oven · odorAIRCRAFT WAS NOT GROUNDED: RIGHT FORWARD GALLEY OVEN SMELLS STRONG OF ROTTEN FISH - MAINTENANCE REPLACED RIGHT FORWARD GALLEY OVEN PER AMM 25-35-19SDR AALA202610218164Elec Connector · unsecureAIRCRAFT WAS NOT GROUNDED: MAIN CABIN SEAT 1C EMERGENCY LIGHT INOP. MAINTENANCE SECURED CONNECTOR PER AMM 33-51-19. OPS TEST OK PER AMM 33-51-00.SDR AALA202610219585Panel · misinstalledAIRCRAFT IN BASE MAINTENANCE: LEFT FORWARD ENTRY DOOR 831 DOOR HANDLE PULLED DOWN WHEN THE DOOR IS OPEN - MAINTENANCE FOUND DOOR HANDLE DOOR CONTACTING DOOR LINING PANEL AND REINSTALLED CORRECTLY DOOR LINING PANEL - A SATISFACTORY OPERATIONAL CHECK WAS ACCOMPLSDR AALA202610261614Hinge Fitting · excess playAIRCRAFT IN BASE MAINTENANCE: LEFT HAND HORIZONTAL STABILIZER ELEVATOR POSITION 1 HINGE ARM END FITTING HAS EXCESSIVE PLAY -MAINTENANCE REPLACED HINGE ARM END FITTING PER AMM 55-16-42SDR AALA202610264124Hinge Fitting · excess playAIRCRAFT IN BASE MAINTENANCE: LEFT HAND HORIZONTAL STABILIZER ELEVATOR POSITION 4 HINGE ARM END FITTING HAS EXCESSIVE PLAY -MAINTENANCE REPLACED HINGE ARM END FITTING PER AMM 55-16-42SDR AALA202610263630Hinge Fitting · excess playAIRCRAFT IN BASE MAINTENANCE: LEFT HAND HORIZONTAL STABILIZER ELEVATOR POSITION 3 HINGE ARM END FITTING HAS EXCESSIVE PLAY -MAINTENANCE REPLACED HINGE ARM END FITTING PER AMM 55-16-42SDR AALA202610264313Hinge Fitting · excess playAIRCRAFT IN BASE MAINTENANCE: LEFT HAND HORIZONTAL STABILIZER ELEVATOR POSITION 6 HINGE ARM END FITTING HAS EXCESSIVE PLAY -MAINTENANCE REPLACED HINGE ARM END FITTING PER AMM 55-16-42SDR AALA202610269167Hinge Fitting · excess playAIRCRAFT IN BASE MAINTENANCE: LEFT HAND HORIZONTAL STABILIZER ELEVATOR POSITION 5 HINGE ARM END FITTING HAS EXCESSIVE PLAY -MAINTENANCE REPLACED HINGE ARM END FITTING PER AMM 55-16-42SDR AALA202610269214Hinge Fitting · excess playAIRCRAFT IN BASE MAINTENANCE: LEFT HAND HORIZONTAL STABILIZER ELEVATOR POSITION 2 HINGE ARM END FITTING HAS EXCESSIVE PLAY -MAINTENANCE REPLACED HINGE ARM END FITTING PER AMM 55-16-42SDR AALA202610216796Wire · disconnectedAIRCRAFT IN BASE MAINTENANCE: AIRCRAFT WAS NOT GROUNDED: EMERGENCY LIGHT ON SEAT 16ABC IS INOP. MAINTENANCE FOUND WIRES DISCONNECTED FROM THE CANNON PLUG AT THE WALL AND RE-TERMINATED BOTH WIRES FOR THE CANNON PLUG - A SATISFACTORY OPERATIONAL CHECK WAS ACCOMPSDR AALA202610193802Flashlight · inoperativeAIRCRAFT WAS NOT GROUNDED: FLASHLIGHT UNDER FLIGHT ATTENDANT 2R SEAT DOES NOT WORK. MAINTENANCE REPLACED EMERGENCY FLASHLIGHT AT 2R JUMPSEAT PER AMM 25-65-00.SDR AALA202610199324Wire Harness · looseAIRCRAFT WAS NOT GROUNDED: SEAT 22ABC EMERGENCY ESCAPE PATH LIGHT INOP. MAINTENANCE RESECURED EMERGENCY LIGHTS HARNESS AT ROW 22ABC PER AWM 33-51-00. OPS CHECK GOOD OK FOR SERVICE.SDR AALA202610194708Wire Harness · looseAIRCRAFT WAS NOT GROUNDED: SEAT 21ABC EMERGENCY ESCAPE PATH LIGHT INOP. MAINTENANCE RESECURED EMERGENCY LIGHTS HARNESS AT ROW 21ABC PER AWM 33-51-00. OPS CHECK OK FOR SERVICE.SDR AALA202610195038Wire Harness · looseAIRCRAFT WAS NOT GROUNDED: CEILING EMERGENCY PATH LIGHT AT SEAT ROW 12 INOPERATIVE. MAINTENANCE RESECURED EMERGENCY LIGHTS HARNESS AT ROW 21ABC PER AWM 33-51-00. OPS CHECK OK FOR SERVICE.SDR AALA202610198920Wire · brokenAIRCRAFT WAS NOT GROUNDED: SEAT 1AB EMERGENCY PATH LIGHT INOP. UPON FURTHER EVALUATION FOUND BROKEN WIRE IN END BAY ASSEMBLY. MAINTENANCE REPLACED END BAY ASSEMBLY PER CMM 25-26-28. OPS CHECK GOOD OKAY FOR CONTINUED SERVICE AT THIS TIME.SDR AALA202610199270Battery · faultedAIRCRAFT WAS NOT GROUNDED: WHILE PERFORMING CIDS1 EPSU SYS TEST ON PS CHECK FOUND CLASS 1 FAULT FOR BAT/EPSU (12WL) EXT R. REMOVED AND REPLACED BATTERY FOR 12WL EPSU. OPS CEHCK GOOD AT THIS TIME. ALL WORK DONE IAW AMM 33-51-38SDR AALA202610190469Lever · looseAIRCRAFT WAS NOT GROUNDED: ARMING LEVER ON DOOR 3L IS LOOSE AND A SCREW IS HANGING OUT OF IT. MAINTENANCE SECURED HARDWARE ON DOOR 3L AS REQUIREDSDR AALA202610192580Smoke Detector · false indicationAIRCRAFT WAS NOT GROUNDED: MULTIPLE WHAT APPEAR TO BE FALSE LAVATORY SMOKE ALARM FORWARD IN FLIGHT - MAINTENANCE ACCOMPLISHED TSM 26-17-00-810-804-A FOR LAVATORY D SMOKE DETECTOR FAULT CODE 26-17-15 - MAINTENANCE PERFORMED LAVATORY D SMOKE DETECTOR TEST PER AMSDR AALA202610194649Elec Connector · damagedAIRCRAFT WAS NOT GROUNDED: CEILING PANEL EMERGENCY LIGHT AT ROW 27 IS INOPERABLE - MAINTENANCE FOUND THE WIRE HARNESS CONNECTOR DAMAGE AND REPLACED THE CONNECTOR AT ESS CEILING LIGHT ASSEMBLY AT ROW 27 - A SATISFACTORY OPERATIONAL CHECK WAS ACCOMPLISHED WITH NSDR AALA202610199866Slide · out of positionAIRCRAFT WAS GROUNDED: DURING WAKE-UP CHECK LIST INSPECTION FOUND R1 DOOR SLIDE POSSIBLY NOT SITTING AGAINST THE DOOR FLUSH - MAINTENANCE REPLACED AFT MOUNTING STUD TO R1 DOOR SLIDE PER AMM 25-62-44SDR AALA202610237245Hinge Fitting · excess playAIRCRAFT IN BASE MAINTENANCE: LEFT HAND HORIZONTAL STABILIZER ELEVATOR POSITION 4 HINGE ARM END FITTING HAS EXCESSIVE PLAY -MAINTENANCE REPLACED HINGE ARM END FITTING PER AMM 55-16-42SDR AALA202610239538Hinge Fitting · excess playAIRCRAFT IN BASE MAINTENANCE: LEFT HAND HORIZONTAL STABILIZER ELEVATOR POSITION 1 HINGE ARM END FITTING HAS EXCESSIVE PLAY -MAINTENANCE REPLACED HINGE ARM PER AMM 55-16-42SDR AALA202610235242Hinge Fitting · excess playAIRCRAFT IN BASE MAINTENANCE: LEFT HAND HORIZONTAL STABILIZER ELEVATOR POSITION 6 HINGE ARM END FITTING HAS EXCESSIVE PLAY -MAINTENANCE REPLACED HINGE ARM END FITTING PER AMM 55-16-42
Back to Airbus Industrie A321-231