Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '206L3' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '206L3' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR HEEA0012037Actuator · failed24 VDC ON EXTEND TERMINAL AND 24 VDC ON RETRACT TERMINAL.SDR HEEA0012036Tach Gen · malfunctionTACH GENERATOR SUSPECT CAUSING LOW RPM HORN WHEN TESTING HYDRAULICS.SDR HEEA0012035Tach Gen · fluctuatingTACH GENERATOR FLUCTUATING INDICATION.SDR HEEA0012034Actuator · inoperativeACTUATOR INOPERATIVE.SDR HEEA0012023Flexure · deterioratedFLEXURE RUBBER DETERIORATED.SDR HEEA0012018Encoder · failedALTITUDE ENCODER NO VALID OUTPUT FROM ENCODER. CALIBRATE TO 28 VDC.SDR HEEA0012014Restraint · wornTRANSMISSION RESTRAINT BEARING WORN.SDR HEEA0012010Tot Indicator · sticksTOT INDICATOR STICKS.SDR HEEA0012009Restraint · wornTRANSMISSION RESTRAINT WORN BEARINGS.SDR HEEA0011991Indicator · failedFUEL PRESS LOAD METER INDICATES NO HIGHER THAN 5 PSI.SDR HEEA0011989Indicator · failedLOW ROTOR AUDIO COMES ON INTERMITTENTLY.SDR HEEA0011968Control · defectiveKFS594 CONTROL HAS NO DISPLAY.SDR HEEA0011964Battery · failedBATTERY HOT CAUTION LIGHT ILLUMINATED ON FIRST DAY OF OPERATION AFTER BATTERY INSTALLATION. REPLACED WITH SERVICEABLE BATTERY.SDR HEEA0011963Shell Assy · defectiveSHELL ASSY RIVETS WORKING L/H AND R/H SIDE AT AFT END OF ROOF PANEL UNDER TRANSMISSION SUPPORTS. INSTALLED RIVETS USING 890 ADHESIVE CR3242-5.SDR HEEA0011961Skid Tube · corrodedSKID TUBE CORRODED DEPTH BEYOND LIMITS. SCRAPPED AND REPLACED WITH SERVICEABLE SKID TUBE.SDR HEEA0011960Skid Tube · crackedRT SKID TUBE CRACKED BELOW AFT CROSSTUBE SUPPORT. SCRAPPED AND REPLACED WITH SERVICEABLE SKID TUBE.SDR HEEA0011945Torque Indicator · mis markedINDICATOR HAS WRONG RANGE MARKINGS FOR RED LINE.SDR HEEA0011941Regulator · failedGENERATOR WOULD NOT COME ON LINE.SDR HEEA0011940Regulator · failedGENERATOR WOULD NOT COME ON LINE.SDR 98ZZZX300Drive Link · wornEXCESSIVE PLAY AT TWO PLACES. SEE BELL MM L-3, FIG 62-21. ON TEAR-DOWN, FOUND BEARINGS AND SPACERS WORN BEYOND LIMITS. TOTAL TIMES OF PARTS LESS THAN 1,000 HOURS/1 YEAR SINCE REPLACEMENT.SDR 98ZZZX299Drive Shaft · wornEXCESSIVE PLAY AT TWO PLACES. SEE BELL MM L-3, FIG 62-21. ON TEAR-DOWN, FOUND BEARINGS AND SPACERS WORN BEYOND LIMITS. TOTAL TIMES OF PARTS LESS THAN 1,000 HOURS/1 YEAR SINCE REPLACEMENT.SDR HEEA0011925Indicator · failedINDICATOR WAS REMOVED FROM BOWL AND CLEANED. INSTALLED INDICATOR BACK ON BOWL, TESTED AND INDICATOR STILL DID NOT WORK. SCRAPPED INDICATOR AND REPLACED WITH SERVICEABLE PART.SDR HEEA0011921Indicator · failedINDICATOR WAS REMOVED FROM BOWL AND CLEANED. INSTALLED INDICATOR BACK ON BOWL, TESTED AND INDICATOR STILL DID NOT WORK. SCRAPPED INDICATOR AND REPLACED WITH SERVICEABLE PART.SDR HEEA0011917Indicator · failedINDICATOR WAS REMOVED FROM BOWL AND CLEANED. INSTALLED INDICATOR BACK ON BOWL, TESTED AND INDICATOR STILL DID NOT WORK. SCRAPPED INDICATOR AND REPLACED WITH SERVICEABLE PART.SDR HEEA0011912Indicator · failedINDICATOR WAS REMOVED FROM BOWL AND CLEANED. INSTALLED INDICATOR BACK ON BOWL, TESTED AND INDICATOR STILL DID NOT WORK. SCRAPPED INDICATOR AND REPLACED WITH SERVICEABLE PART.SDR HEEA0011909Indicator · failedINDICATOR WAS REMOVED FROM BOWL AND CLEANED. INSTALLED INDICATOR BACK ON BOWL, TESTED AND INDICATOR STILL DID NOT WORK. SCRAPPED INDICATOR AND REPLACED WITH SERVICEABLE PART.SDR HEEA0011908Indicator · failedINDICATOR WAS REMOVED FROM BOWL AND CLEANED. INSTALLED INDICATOR BACK ON BOWL, TESTED AND INDICATOR STILL DID NOT WORK. SCRAPPED INDICATOR AND REPLACED WITH SERVICEABLE PART.SDR HEEA0011905Indicator · failedINDICATOR WAS REMOVED FROM BOWL AND CLEANED. INSTALLED INDICATOR BACK ON BOWL, TESTED AND INDICATOR STILL DID NOT WORK. SCRAPPED INDICATOR AND REPLACED WITH SERVICEABLE PART.SDR HEEA0011894Indicator · failedINDICATOR WAS REMOVED FROM BOWL AND CLEANED. INSTALLED INDICATOR BACK ON BOWL, TESTED AND INDICATOR STILL DID NOT WORK. SCRAPPED INDICATOR AND REPLACED WITH SERVICEABLE PART.SDR HEEA0011892Indicator · failedINDICATOR WAS REMOVED FROM BOWL AND CLEANED. INSTALLED INDICATOR BACK ON BOWL, TESTED AND INDICATOR STILL DID NOT WORK. SCRAPPED INDICATOR AND REPLACED WITH SERVICEABLE PART.SDR HEEA0011878Regulator · failedGENERATOR FALLS OFF LINE AFTER 20 MINUTES.SDR HEEA0011869Transceiver · failedTRANSCEIVER INOPERATIVE. PERFORMED PRELIMINARY INSPECTION. FOUND POWER OUT LOW. ADJUSTED V101 CAVITY TUBE. NO HELP. REPLACED V101 CAVITY TUBE P/N C2080A, V301 PHOTOCELL P/N 134-05005-0002 AND FACEPLATE P/N 200-02020-0001, REPAIRED. ADJUSTED PULSE WIDTH ANSDR HEEA0011848Altimeter · failedFAILED 1.1 ON SST ALTIMETER VALID LIGHT DOES NOT STAY ON.SDR HEEA0011840Indicator · failedRATE OF CLIMB INDICATOR FAILED. CANNOT GET INDICATOR TO ZERO.SDR HEEA0011811Power Supply · failedPOWER SUPPLY OUTLET NR2 DOESN'T WORK NR1.SDR HEEA0011808Power Supply · failedPOWER SUPPLY INOPERATIVE.SDR HEEA0011806Power Supply · failedSTROBE LIGHT INOPERATIVE.SDR HEEA0011805Power Supply · failedSTROBE DOES NOT FLASH.SDR HEEA0011804Power Supply · failedSTROBE WILL NOT FLASH TUBE.SDR HEEA0011803Power Supply · inoperativePOWER SUPPLY INOPERATIVE.SDR HEEA0011802Power Supply · weakPOWER SUPPLY WEAK POWER OUTPUT.SDR HEEA0011800Rnav · defectiveRNAV BUTTON STICKS.SDR HEEA0011780Elt · inoperativeELT INOPERATIVE, BATTERY DEAD.SDR HEEA0011776Indicator · sticksTOT NEEDLE STICKS AT ZERO DEGREE INTERMITTENTLY.SDR 97ZZZX4833Bearing · defectiveFOUR NEW M/R GRIP BEARINGS WERE RECEIVED FROM BELL HELICOPTER. A MECHANIC CLEANED THEM PRIOR TO PACKING WITH GREASE AND ON ONE BEARING FOUND THAT ONE ROLLER WAS MISSING, A SECOND BEARING HAD 7 ROLLERS THAT WOULD NOT ROLL IN THE CAGE (APPROXIMATELY 1 INCH SPANSDR HEEA0011704Indicator · inoperativeTURN AND BANK INDICATOR INOPERATIVE.SDR HEEA0011699Stabilizer · dentedSTABILIZER DENTED BEYOND LIMITS.SDR HEEA0011697Cartridge · inoperativeEJECTOR INOPERATIVE.SDR HEEA0011692Regulator · failedREGULATOR MALFUNCTION, WILL NOT REGULATE, TRIPS ON OVER VOLTAGE.SDR HEEA0011687Shell · debondedSHELL DENTED AND SEPARATED.
Back to Bell 206L-3