Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '214ST' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '214ST' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR HEEA079075Bearing · wornCOLLECTIVE CONTROL ASSY HAS WORN BEARINGS.SDR HEEA079074Transceiver · damagedINTERMITTENTLY BREAKS SQUELCH AND WEAK. PERFORMED PRELIMINARY INSPECTION. REMOVED CORROSION FROM CHASSIS. REPLACED CORRODED Q109 AND Q110 TRANSISTORS AND INSULATORS, BAD Q102, Q104 AND Q106 TRANSISTOR INSULATORS, BAD Q110 SOCKET AND BROKEN NAMEPLATE. REPLACSDR HEEA079073Light · inoperativeEXTERIOR STROBE LIGHT INOPERATIVE.SDR HEEA078933Amplifier · will not testELEVATOR AMPLIFIER WILL NOT MONITOR TEST ON NR 1 SIDE.SDR HEEA078932Actuator · failedELEVATOR WILL NOT STAY ON LINE.SDR HEEA078749Amplifier · failedACTUATOR ROLL DROPS OFF DURING FLIGHT.SDR HEEA078748Actuator · will not testMAIN ROTOR ACTUATOR WON'T COMPLETE TEST.SDR HEEA078747Actuator · will not testWOULD NOT COMPLETE MONITOR TEST AFTER INSTALLATION. WOULD MOVE SLOW OR VERY LITTLE.SDR HEEA078608Starter · failedWILL NOT MOTOR ENGINE. SOUNDS LIKE STARTER PAWL NOT ENGAGING.SDR HEEA078605Cover · looseFOUND LT FLOAT FAIRING LOOSE. FOUND TOP EDGE HAD COME LOOSE FROM SCREWS AND WIND HAD PULLED COVER OPEN.SDR HEEA078601Actuator · failedROTARY ACTUATOR IS STICKING. WILL NOT RELEASE.SDR HEEA078599Starter · malfunctionedSTARTER SPINS BUT DOES NOT ENGAGE.SDR HEEA078592Amplifier · intermittentNR 1 ELEVATOR SYSTEM WILL ONLY STAY ON LINE FROM 15 MINUTES TO ONE HOUR 30 MINUTES. CAN RE-ENGAGE SYSTEM AND WILL WORK FOR ABOUT ANOTHER HOUR BEFORE KICKING OFF LINE.SDR HEEA078265Starter · malfunctionedSTARTER WILL NOT DISENGAGE.SDR HEEA078261Actuator · malfunctionedELEVATOR TRIPS OFF LINE.SDR HEEA078256Amplifier · will not testWILL NOT MONITOR TEST AND YAW DISENGAGE LIGHT TOO DIM.SDR HEEA078172Actuator · will not testOPPOSITE ELEVATOR SYSTEM WOULD NOT MONITOR TEST.SDR HEEA078171Actuator · malfunctionedELEVATOR ACTUATOR OCCASSIONALLY KICKS OFF LINE ON TAKE OFF AND LANDING.SDR HEEA078119Controller · malfunctionedAIRCRAFT WILL NOT HOLD ALTITUDE. ALTITUDE CONTROLLER MALFUNCTIONED.SDR HEEA078025Starter · damagedSTARTER HAS A DEAD SPOT.SDR HEEA078023Isolation Amp · failedIN FLIGHT THE CREW DETECTED A SMOKE ODOR. THE AARS AND NR 2 ELEVATOR SYSTEM WENT OFF LINE. THE CIRCUIT BREAKER FOR THE COPILOT ADI TRIPPED. MAINTENANCE REPLACED THE ISOLATION AMPLIFIER.SDR HEEA078022Amplifier · failedELEVATORS WILL NOT TEST.SDR HEEA078021Actuator · failedELEVATORS WILL NOT TEST.SDR HEEA077882Amplifier · failedAMPLIFIER KICKS ELEVATORS OFF LINE WHEN ENGAGED.SDR HEEA077881Actuator · malfunctionedACTUATOR KICKS ELEVATORS OFF LINE.SDR 2002F00900Light · contaminatedDURING PREFLIGHT CHECK, NR 1 FIRE LIGHT WOULD NOT TEST, WATER CONDUCTOR. AFTER BEING DRIED OUT SYSTEM OPERATED PROPERLY. (M)SDR HEEA077853Starter · stuckPILOT HAS TO DISENGAGE STARTER MANUALLY. HANGS UP.SDR HEEA077843Pump · failedDURING FLIGHT, UTILITY HYDRAULIC SYSTEM FAILED. MAINTENANCE FOUND UTILITY HYDRAULIC PUMP DELIVERY PRESSURE LOW.SDR HEEA077842Amplifier · failedPITCH LIGHT INOP. WON'T MONITOR TEST. AUTOFLIGHT AMPLIFIER FAILED.SDR HEEA077826Volt Regulator · failedVOLTAGE DROPPING TO 20 VOLTS ON CROSS START, DUE TO MALFUNCTIONING VOLTAGE REGULATOR.SDR HEEA077824Starter · malfunctionedSTARTER WILL NOT AUTOMATICALLY DISENGAGE AFTER ENGINE IS STARTED.SDR HEEA077729Actuator · failedACTUATOR WILL NOT ALLOW AARS PITCH CHANNEL TO COME ON LINE.SDR HEEA077726Starter · malfunctionedSLOW STARTS. HAVING STARTER PROBLEMS.SDR HEEA077725Adc · will not testNR 1 POWER ASSURANCE WILL NOT TEST.SDR HEEA077680Amplifier · malfunctionedAMPLIFIER CAUSING PITCH AXIS TO KICK.SDR HEEA077679Amplifier · malfunctionedCAUSES ELEVATOR LIGHT TO STAY ON.SDR HEEA077678Amplifier · will not testWON'T MONITOR TEST. STICK WANDERS. DIFFICULT TO ADJUST R91 ON BOARD 11 & 9.SDR HEEA077676Relay · burnedBURNT CONTACTS. VOLTAGE ON STARTS WON'T GO ABOVE 32 VDC.SDR HEEA077675Relay · burnedBURNT CONTACTS. VOLTAGE ON STARTS WON'T GO ABOVE 32 VDC.SDR HEEA077666Pin · sheared250 HOUR INSPECTION, PIN SHEARED IN CLUTCH SHAFT.SDR HEEA077659Structure · crackedDURING POST FLIGHT INSPECTION, MAINTENANCE DISCOVERED CRACK IN TAIL BOOM VERTICAL PYLON STRUCTURE.SDR HEEA077580Amplifier · malfunctionedCAUSES ELEVATOR TO TRIP OFF LINE.SDR HEEA077448Starter · malfunctionedSTARTER WON'T STAY ENGAGED.SDR HEEA077447Starter · weakSTARTER IS WEAK.SDR HEEA077446Starter · slowSTARTER IS SLOW TO START.SDR HEEA077439Starter · malfunctionedSTARTER STAYS STUCK IN THE ON POSITION.SDR HEEA077438Starter · inoperativeSTARTER WILL NOT STAY ENGAGED.SDR HEEA077433Idler Gear · missingBEARING MISSING WHEN PACKAGED PART WAS OPENED.SDR HEEA077404Actuator · malfunctionedACTUATOR TRIPS OFF BOTH ELEVATOR SYSTEMS.SDR HEEA077403Amplifier · malfunctionedPITCH TRIPS AFTER 30 TO 45 MINUTES OF FLIGHT. RESETS BUT ONLY FOR SHORT PERIOD OF TIME.
Back to Bell 214ST