SDR ZZDA2009247Seat Track · corrodedFLOOR SEAT TRACK WITH GALLEY SUPPORT ABOVE AT STA 239 RBL 44 CORRODED. CUT OUT DAMAGED SECTION OF FLOOR TRACK RBL 44 FROM STA 200 TO STA 245, INSTALLED NEW TRACK SECTION AND SPLICE REPAIR REF DC9 SRM 53-05 4F AND EA 17-53-01776IR.SDR ZZDA2009246Door Frame · corrodedFWD CARGO COMPARTMENT DOOR CUTOUT CORRODED. CUT OUT DAMAGED LOWER SECTION AND INSTALLED LOWER SECTION AND SPLICE REPAIR PER REF B717 SRM 53-20-15 REPAIR 6 FIG 201.SDR ZZDA2009245Frame · damagedEO 17-5310-2895 AFT RIGHT STA 1178 CANTED FRAME INSPECTION IDENTIFIED CONFIGURATION 1 CONDITION 1. ACCOMPLISHED REPAIR TO AFT FUSELAGE FRAME CAP, CANTED STA 1178.225, RIGHT SIDE IAW AIRTRAN TASK CARD 17-5310-2984.SDR ZZDA2009244Frame · damagedEO 17-5310-2937 AFT LEFT STA 1178 CANTED FRAME INSPECTION IDENTIFIED CONFIGURATION 1 CONDITION 3. ACCOMPLISHED REPAIR TO AFT FUSELAGE FRAME CAP, CANTED STA 1178.225, LEFT SIDE IAW AIRTRAN TASK CARD 17-5310-2975.SDR HALA2009082800399Line · misinstalledDURING ACCOMP OF ANTI-SKID BRAKE RELEASE TEST AMM 32-45-00-730-804 TEST FOR LT HYD SYS, COMMAND FOR NR 3 WOULD RELEASE NR 4 BRAKE AND COMMAND FOR NR 4 WOULD RELEASE NR 3 BRAKE. FOUND NR 3 AND NR 4 BRAKE LINES CROSSED (AFT SIDE). REROUTED BRAKE LINES TO CORRESDR HALA2009082800398Tire · failedAFTER LANDING, DECELERATING THROUGH 80 KTS RT SKID FAIL ILLUMINATED CONCURRENT TIRE BLOWING ACFT RT, TAXIIED TO GATE. INSP ACFT AND NO DEFECTS NOTED. REMOVED AND REPLACED NR 3 TIRE DUE TO FLAT AND NR 4 TIRE FOR PRECAUTIONARY. CLEARED FAULT IAW FIM 32-45-00-SDR HALA2009082500385Engine · failedLEFT ENG SYS FAIL. REMOVED AND REPLACED LT ENGINE. OPS AND LEAK CHECK GOOD.SDR ZZDA2009250Frame · damagedEO 17-5310-2895 AFT RIGHT STA 1178 CANTED FRAME INSPECTION IDENTIFIED CONFIGURATION 2 CONDITION 1. ACCOMPLISHED REPAIR TO AFT FUSELAGE FRAME CAP, CANTED STA 1178.225, RIGHT SIDE IAW AIRTRAN TASK CARD 17-5310-2986.SDR ZZDA2009249Frame · damagedEO 17-5310-2937 AFT LEFT STA 1178 CANTED FRAME INSPECTION IDENTIFIED CONFIGURATION 2 CONDITION 1. ACCOMPLISHED REPAIR TO AFT FUSELAGE FRAME CAP, CANTED STA 1178.225, LEFT SIDE IAW AIRTRAN TASK CARD 17-5310-2976.SDR ZZDA2009212Doubler · dentedDENT FOUND AT STA 228 TO 237, LOCATED ON PREVIOUS REPAIR OF FUSELAGE SKIN. ACCOMPLISH FUSELAGE SKIN REPAIR STA 229 TO 244. REF B717 SRM 53-00-01 FIG 201 SHEET 4.SDR ZZDA2009211Actuator · crackedDURING TAKEOFF WHEN LANDING GEAR UP WAS SELECTED RIGHT MLG RETRACT CYLINDER HAD A STRUCTURAL FAILURE, RESULTING IN TOTAL LOSS OF HYDRAULIC SYSTEM RIGHT FLUID AND PRESSURE. THE BARREL ASSY CRACKED AND SEPARATED APPROX 2 INCHES ABOVE LOWER GLAND. REMOVED AND RSDR ZZDA2009210Battery · dischargedWHILE PERFORMING MAINTENANCE CHECK OF THE EMERGENCY ESCAPE LIGHTING SYSTEM, BOTH LT AND RT FUSELAGE LIGHTS JUST FORWARD OF ENGINES ARE INOP. REMOVED AND REPLACED OVERWING EMERGENCY EVACUATION BATTERY POWER SUPPLY IAW AMM 33-51. OPS CHECK GOOD.SDR ZZDA2009209Slide · unwanted deployR1 DOOR SLIDE INADVERTENTLY DEPLOYED BY A/C CLEANERS. INSTALLED NEW FORWARD SERVICE DOOR SLIDE PER B717 AMM 25-61-03.SDR HALA2009081300364Cover · misinstalledFWD LEFT DOOR SLIDE PACK OPENED, SMALL PORTION OF SLIDE FABRIC EXPOSED. REINSTALLED L-1 DOOR SLIDE COVER SECURITY CHK GOO D. OK FOR SERVICE.SDR HALA2009081100363Unknown · odorON LANDING, SMELLED BURNING ELECTICAL ODOR AFTER LANDING, GOT RT PACK OVERHEAT ON DISPLAY. IAW QRH TURNED RT PACK OFF. OK TO CONTINUE IAW MEL 21-51-01 VERFIED RT FLOW CONTROL VALVE IN CLOSED POSITION AND SECURED. OPENSDR ZZDA2009208Connector · looseEMERGENCY EXIT LIGHT ABOVE REAR EMERGENCY EXIT WAS ILLUMINATED IN FLIGHT. ALL OTHER SIGNS WORKED NORMALLY. FOUND REAR EMERGENCY LIGHT AT EXIT HAD BATTERY PACK CONNECTOR LOOSE. SECURED CONNECTOR. OP CHECK GOOD PER AMM 33-51-00.SDR ZZDA2009215Battery Pack · dischargedEXTERIOR EMERGENCY LIGHT ON WITH SWITCH IN "ARM" POSITION. REMOVED AND REPLACED EMERGENCY BATTERY PACK IAW M/M 33-51-06. OK FOR SERVICE.SDR ZZDA2009207Pin · looseEMERGENCY LIGHTS AT ROW 1 2 EACH INOPERATIVE. FOUND LOOSE PIN FOR CONNECTOR UNDER SEAT. RE-ALIGNED & OPS CHECK GOOD IAW WDM SP.SDR CA090806009Tube · missingDURING NORMAL PRODUCTION OF ENG MX, A SET OF 4 NEW LP/HP TURBINE COOLING AIR TUBES WERE FOUND FOR AN ENG THAT WAS ALREADY IN OPERATION. INVESTIGATION ON MATERIAL INVENTORY HAS CONCLUDED THAT 4 LP/HP AIR COOLING TUBES WERE NOT INSTALLED ON ENG PREVIOUSLY DELIVESDR HALA2009080100342Apu · odorFLT CREW REPORTED ODOR OF SMOKE/ ELECTRICAL ODOR IN COCKPIT AND ALSO IN CABIN. REPLACED APU IAW HAL 1339-17 OPS CK GOOD.SDR HALA200908010034Apu · odorFLT CREW REPORTED ODOR OF SMOKE/ ELECTRICAL ODOR IN COCKPIT AND ALSO IN CABIN. REPLACED APU IAW HAL 1339-17, OPS CK GOOD.SDR HALA2009072900339Via · failedAFTER DEPARTURE EXPERIENCED MAP SHIFT AND NAVIGATION UNREALABLE, NR 2 DU FAILED ALSO. REPLACED NR 1 VIA, GND CHECK OK IAW MM 31-43-00.SDR HALA2009072400324Sensor · malfunctionedENG L SYS FAIL ALERT WHILE AIRBORNE. BITE CK EEC-1. FOUND MSG 771202. ACCOMP FIM 77-12 TASK 802. REMOVED AND REPLACED N2 SPEED SENSOR CH B, RAN ENGINE NR 1 ON GROUND. OPS CK OK.SDR ZZDA2009203Pin · out of positionREINSTALL PIN IN L-1 DOOR SLIDE PACK. RE-INSTALLED LANYARD PER AMM 25-61.SDR HALA2009072000318Skin · corrodedLEVEL 2 CORROSION ON THE LOWER TCAS ANTENNA BASE. REPAIR IN WORK.SDR HALA2009072000316Circuit Card · malfunctionedETOPS SIGNIFICANT SYSTEM - BTB, RT AIR CONDITIONING PACK ILLUMINATES "INOP" "PACK OFF". ACCOMPLISHED FIM 21-50-00 AND WDM 21-51-21 REPLACED RT FLOW CONTROL CARD (M864) PER AMM 21-51-09 OPERATIONAL TEST PER AMM 21-51-09 CHECKS OKAY. RAN PACK WITH NUMEROUS TESDR HALA2009072000313Skin · dentedENTRY DOOR GOT JAMMED BY JETBRIDGE CAUSING POSSIBLE DAMAGE. FOUND DOOR SKIN DENT AFT SIDE 3" X 3/4" FWD SKIN DENT 6" X 1" EDDY CURRENT CK OK NO CRACKS PRESS CK OK OKAY PER HAL M105 INTERM REPAIR 1 CYCLE ONLY.REPAIRED PER 717 SRM 52-00-00-2R-3. OK FOR SERVICE.SDR ZZDA2009202Pin · out of positionFWD DOOR (L-1) SLIDE PIN CAME OUT OF ARMED POSITION. REINSTALLED GIRT BAR LANYARD ASSY. SLIDE OK FOR SERVICE REF MM 25-61.SDR ZZDA2009201Battery · dischargedE-LIGHTS ON SEATS 1 DF - 3DF INCLUDED NR 2 GALLEY INOP (NOT TURN ON). REPLACED BATTERY SUPPLY ASSY AND BATTERY ASSY PER B717 MM33, OP'S TEST OK.SDR ZZDA2009199Battery · defectiveOVERWING EMERGENCY LIGHTS ILLUMINATED WITH EMERGENCY LIGHT SWITCH IN ARM. REMOVED AND REPLACED EMERGENCY BATTERY SUPPLY FOR EMERGENCY OVERWING LIGHTS. REF 717 AMM 33-51-06. OPS CHECKED GOOD.SDR ZZDA2009198Power Supply · inoperativeEMERGENCY E-PATH LIGHTS NOT WORKING AT SEAT ROW 1DF, 2DF, 3DF AND 10DEF. FOUND IMPROPER E-PATH LAMPS INSTALLED AT SEAT 3DF. REMOVED AND REPLACED EMERGENCY LIGHT BATTERY SUPPLY ASSEMBLY B5-118 IAW 33-51-03. RELAMPED E-PATH LIGHTS AT SEAT ROW 3DEF. OPS CHECKSDR HALA2009070500273Detection Sys · no testFIRE TEST NR 1 FIRE HANDLE NO LIGHT. REPLACED LT ENG A LOOP.SDR ZZDA2009197Bolt · missingRIGHT MAIN GEAR UNSAFE INDICATION WITH GEAR HANDLE IN UP POSITION. FOUND RIGHT MAIN LANDING GEAR INBOARD DOOR UPLOCK SWITCH TARGET BOLT MISSING. REPLACED BOLT AND OPERATED LANDING GEAR UP AND DOWN 5 TIMES. CHECKS GOOD IAW REF AMM 32-10.SDR ZZDA2009195Battery Pack · inoperativeSEVERAL BATTERY PACKS HAVE FAILED THE EMERGENCY BATTERY PACK CAPACITY FUNCTIONAL CHECK TC 33-055-00-01. REMOVED AND REPLACED EMERGENCY BATTERY PACKS M1670, M1674, M1675, M1669, M672, M673 IAW AMM 33-51-06. FUNCTIONAL CHECK GOOD.SDR HALA2009062600263Smoke Detector · no testNO CARGO SMOKE TEST. RESET C/B CARGO SMOKE TEST OK.SDR ZZDA2009193Slide · low pressureL1 PACK PRECHARGE APPEARS LOW. REMOVED AND REPLACED L1 DOOR SLIDE REF MM 25-61-01.SDR ZZDA2009192Power Supply · activatedEMERGENCY EXIT LIGHT INOP AT AFT DOOR. REPLACED EMERGENCY LIGHT POWER SUPPLY REF AMM 33-51-03 (B5-260 LOCATION).SDR MWEA090015Bleed Valve · contaminatedHAZE/SMOKE IN FLIGHT COMPARTMENT DURING TAXI AFTER APU STARTED TO SUPPLEMENT AIR CONDITIONING; OIL CONTAMINATION WAS FOUND IN THE APU BLEED MODULATING VALVE.SDR HALA2009062000256Control Cable · brokenLT OUTBOARD SLAT NOT FULLY RETRACTED DURING WALK AROUND. FOUND NR 5 RETRACT CABLE NR 194A BROKEN. REPLACED RUN NR 194A PER DRW 5910451. ADJUSTED LT SLAT CABLES PER AMM 27-80 00.SDR HALA2009061500251Isolator · gougedGOUGE ON NR 2 ENGINE FWD UPPER ISOLATOR. REMOVED AND REPLACED NR 2 FWD UPPER ISOLATOR PER TASK 71-20-05-000-801, 71-20-05-400-801.SDR HALA2009061500250Seal · damaged1 INCH CRACK ON THE NR 2 ENGINE LOWER APRON FIRE SEAL L/E 2ND FASTENER HOLE. REPAIRED PER HAL-M-105. FILE NR B10196.SDR HALA2009061500249Retainer · crackedNR 2 ENGINE PYLON T/E FWD LOWER GAP SEAL RETAINER CRACKED. REPAIRED PER HAL M-105 FILE NR 486106.SDR HALA2009061100031Spar · corrodedMODERATE CORROSION ON THE LT WING REAR SPAR LWR TANG AT ARS 164 (AREA I/B FLAP ACT FITTING). ACCOMPLISHED PERMANENT REPAIR AS PER MESSAGE HWI 09-0047-08B AND DWG NR J060271.SDR ZZDA2009190Connector · malfunctionedFWD F/A SEAT & L1 EMERGENCY LIGHTS REMAIN ILLUMINATED WITH O/H & FWD F/A PANEL SWITCHES IN OFF POSITION. RESET CONNECTOR AT EMERGENCY LIGHT BATTERY PACK AT STA 121 IN CTR DRP DOWN CEILING. LIGHTS EXTINGUISHED AND COMPLETE EMERGENCY IS FULLY FUNCTIONAL.SDR ZZDA2009191Pan · corrodedAFT CARGO COMPARTMENT DOOR CUTOUT LOWER PAN SECTION HAS CORROSION OUT OF LIMITS. CORROSION: TRIMMED OUT DAMAGED SECTION AND ACCOMPLISHED REPAIR REF B717 SRM 53-20-15 FIG 201.SDR MWEA090014Battery Pack · inoperativeEMERGENCY LIGHTS AT ROW 17 INOP -- REMOVED AND REPLACED EMERGENCY LIGHT BATTERY PACK.SDR HALA2009060900030Spar · corrodedMODERATE CORROSION ON REAR SPAR LWR TANG AT XRS 267 (AREA O/B FLAP ACT FITTING). ACCOMPLISHED PERMANENT REPAIR PER BOEING MSSG. NR HWI 09-0047-08B AND DRWG NR J060271.SDR ZZDA2009196Battery · inoperativeOVERWING EMERGENCY EXIT LIGHTS ON WITH SWITCH IN OFF POSITION. REMOVED AND REPLACED EMERGENCY BATTERY ASSY AMM 33-50, OPS CHECK GOOD.SDR ZZDA2009188Frame · damagedEO 17-5310-2895 AFT RIGHT STA 1178 CANTED FRAME INSPECTION IDENTIFIED CONFIGURATION 2 CONDITION 5. ACCOMPLISHED REPAIR TO AFT FUSELAGE FRAME CAP, CANTED STA 1178.225, RIGHT SIDE IAW AIRTRAN TASK CARD 17-5310-2990.SDR ZZDA2009187Frame · damagedEO 17-5310-2937 AFT LEFT STA 1178 CANTED FRAME INSPECTION IDENTIFIED CONFIGURATION 2 CONDITION 1. ACCOMPLISHED REPAIR TO AFT FUSELAGE FRAME CAP, CANTED STA 1178.225, LEFT SIDE IAW AIRTRAN TASK CARD 17-5310-2976.
Back to Boeing 717-200