Boeing 727-223
Service difficulty reports · 5,313
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '727223' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '727223' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA972231Floorbeam · corrodedTUL - FOUND CORROSION ON TOP OF FLOORBEAM. INSTALLED DOUBLER ON FLOORBEAM PER SRM 53-10-8. (M)SDR AALA972230Angle · corrodedTUL - FOUND CORROSION ON CREASE ANGLE FROM FS 344 TO 354 RIGHT SIDE. REMOVED CORRODED SECTION AND INSTALLED NEW SECTION. (M)SDR AALA972229Stiffener · crackedTUL - INSPAR STIFFENER UPPER NR 10 CRACKED AT STATION 686.50 LT WING TANK. STOP DRILLED CRACK INSTALLED DOUBLER PER BOEING SB 727-57A159. (M)SDR AALA972228Skin · gougedTUL - GOUGE IN SKIN AT STRINGER 2R, STATION 840 BLENDED BEYOND LIMITS. CUT OUT DAMAGE AND INSTALLED DOUBLER PER SRM 53-30-3. (M)SDR AALA972227Stringer · crackedTUL - TOP WING STRINGER CRACKED AT WS 686.50 AFT CENTER LINE. REPAIRED STRINGER PER BOEING SERVICE BULLETIN 727-57A159. (M)SDR AALA972226Frame · dentedTUL - BELL FRAME STATION 1090 ABOVE STRINGER 26L, DENTED. CUT OUT DAMAGED AREA AND INSTALLED DOUBLER IAW SRM 53-10-4. (M)SDR AALA972225Stringer · corrodedTUL - STRINGER CORRODED STRINGER 27L, STATION 628-632. CUT OUT DAMAGED SECTION OF STRINGER 27L AND INSTALLED REPAIR STRINGER PER 53-0-3 FIG 1 PAGE 3. (M)SDR AALA972224Stringer · corrodedTUL - STRINGER 27R BLOWN OUT OUTBOARD SIDE STATION 720 PLUS 10 INCHES. REMOVED DAMAGED SECTION OF STRINGER SPLICED IN NEW SECTION PER SRM 53-10-3 FIG 1. (M)SDR AALA972223Frame · corrodedTUL - FOUND CORROSION ON AFT SIDE OF FRAME OUTBOARD OF STRINGER 27R, STATION 500. REMOVED CORROSION AND REPLACED SHEAR TIE. (M)SDR AALA972222Stringer · corrodedTUL - STRINGER 29R CORRODED AT STATION 1010-1018. REMOVED CORRODED SECTION OF STRINGER STATION 1010 THROUGH 1018, STRINGER 29R. INSTALLED NEW SECTION OF STRINGER 29R STATION 1000 TO 1020. (M)SDR AALA972221Skin · corrodedTUL - BULGE IN FUSE SKIN AT STRINGER 29R, STATION 1016 - STATION 1018. REMOVED EXCESSIVE CORROSION DAMAGE BY CUTTING SKIN AT BULGED AREA AND FABRICATED AND INSTALLED DOUBLER AND FILLER. (M)SDR AALA972220Stringer · corrodedTUL - STATION 650, STRINGER 27R DEEP CORROSION IN CENTER OF STRINGER, NEXT TO RIVET. INSTALLED 'U' CHANNEL INSIDE STRINGER PER SRM 53-10-3, AFTER REMOVAL, TREATED AND PRIMED OF CORROSION. (M)SDR AALA972203Spar Web · crackedTUL - FOUND CRACK INDICATION APPROX RBL 5 INCHES ON UPPER REAR SPAR WEB. STOP DRILLED CRACK AND INSTALLED REPAIR STRAP AND FILLER PER ESO 11697, DATED 11/11/97. (M)SDR AALA972202Frame · misdrilledTUL - INBOARD FRAME FLANGE AT STATION 760.95 RIGHT HAS MISDRILLED HOLE AT APPROX WL 212. OPENED HOLE AND INSTALLED FREEZE PLUG PER SRM 51-10-7. INSTALLED REPAIR DOUBLER AND STRAPS PER BOEING SERVICE BULLETIN 727-53-0197 AND DWG NR 65C36279. (M)SDR AALA972194Fitting · corrodedTUL - FS 1183, STRINGER 19LT END FITTING IS BROKEN IN TWO DUE TO SEVERE EXFOLIATION CORROSION IN STRINGER AND FITTING. REPLACED STRINGER 19L STATION 1183 END FITTING WITH NEW FITTING PER SRM 51-10-1. (M)SDR AALA972193Intercostal · corrodedTUL - FORWARD OF BS 500, OUTBOARD OF STRINGER 26R, 2 INTERCOSTAL CORRODED AND DOOR CUTOUT FRAME WEB AT STATION 553 CORRODED. BLENDED OUT CORROSION AT DOOR CUT-OUT FRAME WEB. REPLACED CORRODED INTERCOSTAL WITH NEW PARTS, TREATED AND PRIMED APPLICABLE AREAS. SDR AALA972192Skin · corrodedTUL - SKIN BULGED AT AFT EDGE OF THE AFT LAV SERVICE PANEL AT STATION 1180, STRINGER 20L TO 21L (FUSELAGE SKIN). REMOVED CORRODED SECTION OF SKIN AND INNER DOUBLER (AREA PREVIOUSLY WORKED). INSTALLED NEW INNER DOUBLER AND REPAIR DOUBLER WITH FILLER PER SRM 5SDR AALA972191Bulkhead Web · crackedTUL - STATION 870 BULKHEAD CRACKED AT CUTOUT FOR APU LOAD CONTROL VALVE. STOP DRILLED CRACK AND INSTALLED DOUBLER PER SRM 53-10-2 PAGE 261 (C). (M)SDR AALA972190Frame · brokenTUL - BELTFRAME ON LOWER FORWARD CORNER OF AFT CARGO DOOR BROKEN. CUT OUT DAMAGE AND INSTALLED STAINLESS FORMER REPAIR PER SRM 51-40-3. (M)SDR AALA972189Wire · delaminatedTUL - FLAT CONDUCTOR WAS DELAMINATED PRODUCING AN OPEN CIRCUIT. AFT SECTION OF EMERGENCY AISLE LIGHTS INOP. REPLACED P/N A3-06-0720-204, LIGHTS OPS CHECK OK. (M)SDR AALA972188Shear Tie · corrodedTUL - FUSELAGE SKIN HAS BULGE JUST ABOVE STRINGER 26L SKIN LAP AT STATION 599 TO 601. REMOVED CORRODED SHEAR TIE AT STATION 600 , STRINGER 25L-26L AND REPLACED WITH NEW PER SRM 53-10-4. (M)SDR AALA972187Stringer · corrodedTUL - STRINGER 28L HAS SEVERAL CORROSION PITS 12 INCHES FORWARD OF STATION 740 ON OUTBOARD STRINGER FLANGE. INSTALL REPAIR PER ESO 11697. (M)SDR AALA972186Angle · corrodedTUL - STATION 336 LBL 10 NLG DRAG BRACE SUPPORT WEB ANGLE CORRODED AT FWD SIDE. INSTALLED NEW ANGLE PER SRM 51-10-1. (M)SDR AALA972182Wire · looseMIA - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT FLOOR PATH LIGHTING AT MID CABIN WOULD NOT TEST. SECURED WIRING, SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA972178Connector · looseMIA - DURING OVERNIGHT CHECK, FOUND EMERGENCY EXIT FLOOR PATH LIGHTING AT MID CABIN INOPERATIVE. SECURED SEGMENT OF EMERGENCY EXIT FLOOR PATH LIGHTING AT MID CABIN BELOW SEAT. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA972171Light · defectiveRDU - DURING OVERNIGHT MAINTENANCE, FOUND THE AFT RIGHT HAND CABIN FLIGHT ATTENDANTS EMERGENCY FLASHLIGHT SEALS BROKEN. REPLACED SEALS ON AFT RIGHT HAND CABIN FLIGHT ATTENDANT EMERGENCY FLASHLIGHT. SYSTEM GROUND CHECKED, NORMAL OPERATION. (X)SDR EISA97226Wire · brokenEMERGENCY EXIT 'UNARMED LIGHT' YELLOW LIGHT INOP. REPAIRED BROKEN WIRE, PER STANDARD PRACTICES, OPS CHECK GOOD. (M)SDR CKSA97568Accessory Unit · malfunctionedAFTER T/O WITH GEAR HANDLE PLACED IN THE UP POSITION RED DOOR LIGHTS AND TAIL SKID LIGHT REMAINED ILLUMINATED, F/E SECONDARY INDICATORS AND DOOR LIGHTS WERE OUT. RECYCLED GEAR SAME INDICATIONS. REMOVED AND REPLACED LANDING GEAR ACCESSORY UNIT SYSTEM OP CKD GSDR AALA972154Spar Chord · corrodedTUL - RIGHT FORWARD SPAR CHORD ANGLE HAS CORROSION FROM FUSELAGE 2073-2088, SECTION OF CHORD PREVIOUSLY GROUND AWAY APPROX 1.187 BY 2.5O. INSTALLED DOUBLER REPAIR PER ESO 11697, DATED 10/27/97. (M)SDR AALA972153Shear Tie · corrodedTUL - FOUND CORROSION ON SHEAR TIE, BETWEEN STRINGER 26R AND 25R, INBOARD END AFT SIDE. INSTALLED NEW SHEAR TIE STATION 520 BETWEEN STRINGER 26R AND 25R PER SRM. (M)SDR AALA972152Beam · crackedTUL - .7 INCH CRACK IN OUTBOARD FLANGE OF THE LBL 36 VERTICAL BEAM 30 INCHES FROM FLOOR LINE. STOP DRILLED CRACK AND INSTALLED DOUBELR PER SB 727-53-0192 FIG 2 DATED 5-30-91.SDR AALA972151Stringer · corrodedTUL - STRINGER 27L CORRODED AT SKIN STATION 1040 TO 1057. REPAIRED STRINGER 27L IAW SRM 53-10-3 FIG 1. (M)SDR AALA972150Stringer · crackedTUL - FOUND CRACK ON STRINGER UNDER FIRST HUCK BOLT FROM END OF STRINGER AT STRINGER 15R, STATION 720B. REMOVED DAMAGED SECTION OF STRINGER AND REPAIRED PER SRM 53-10-3. (M)SDR AALA972149Stringer · corrodedTUL - CORROSION LOCATED IN BOTTOM OF STRINGER 28L. CUT OUT DAMAGED STRINGER REPLACED WITH SERVICEABLE STRINGER SPLICED BOTH ENDS. (M)SDR AALA972148Panel · corrodedTUL - FOUND CORROSION ON LEFT GEAR BEAM, SEVERAL HOLES WHERE TRAIL EDGE LOWER WING PANEL ATTACHES, AROUND HOLES. REPAIRED BEAM PER ESO 11697, DATED 10-24-97. (M)SDR AALA972144Skin · crackedTUL - FUSELAGE SKIN CRACKED AT LOWER HINGE CUTOUT AT FORWARD ENTRY. REPAIRED PER BSB 727-53-0198 FIG 4 DETAIL 11. (M)SDR AALA972143Hinge Box · crackedTUL - .875 INCH LONG CRACK IN INBOARD FLANGE (SEAL LANDING). REMOVED DAMAGED TOP HINGE BOX. INSTALLED NEW TOP HINGE BOX ON E58 NR 2364338. (M)SDR EISA97223Light · inoperativeCOCKPIT DOOR EMERGENCY EXIT LIGHT STAYS ON WITH POWER OFF. CLEANED COCKPIT DOOR EMERGENCY EXIT LIGH TBATTERY CONTACTS. OPS CHECK GOOD PER MM 33-50-01. (M)SDR AALA972068Sign · missingATL - DURING OVERNIGHT CHECK, FORWARD ENTRY EMERGENCY EXIT SIGN MISSING AND BASE BROKEN. REPLACED FORWARD ENTRY EMERGENCY EXIT SIGN ASSEMBLY. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA972045Frame · corrodedTUL - FOUND CORROSION ON FRAME ABOVE 29R AT STATION 985 FORWARD SIDE. REMOVED FRAME, FABRICATED AND DRILLED NEW FRAME AT STATION 985, TREATED, PRIMED AND INSTALLED IAW SRM 51-10-1. (M)SDR AALA972044Shear Tie · corrodedTUL - CARGO COMPARTMENT SHEAR TIE FOUND WITH CORROSION AT BS 970. REPLACED SHEAR TIE PER ESO 1169F, DATED 23 OCT 97. (M)SDR AALA972043Vert Beam · crackedTUL - FOUND CRACK AT BOTTOM OF VERTICLE BEAM RBL 10 STATION 1183. INSTALLED DOUBLER PER SERVICE BULLETIN 727053-0175. (M)SDR AALA972042Stringer · corrodedTUL - FOUND STRINGER 27R CORRODED FROM FS 695 TO FS 715. REPLACED STRINGER SECTION. (M)SDR AALA972040Angle · corrodedTUL - LOWER CHORD ANGLE CORRODED/CRACKED AT 4 RIVETS FS 195. REMOVED CORROSION, ROUTED OUT AND CRACKED AREA. INSTALLED DOUBLER AND TRIPLER PER SRM 57-10-6. (M)SDR AALA972039Skin · corrodedTUL - FUSELAGE SKIN CORRODED BETWEEN STRINGER 26R AND STRINGER 27R FS 696-697. CUT OUT CORROSION AND INSTALLED DOUBLER. (M)SDR AALA972021Wire · brokenMIA - DURING OVERNIGHT CHECK, EMERGENCY FLOOR LIGHTS BETWEEN PAX SEAT ROWS 5 AND 28 INOPERATIVE. REPAIRED BROKEN WIRE BY PAX SEAT ROW 5. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA972041Stringer · corrodedTUL - FOUND STRINGER CHANNEL CORRODED AROUND FASTENERS BETWEEN STATION 695 TO STATION 704 STRINGER 28R. INSTALLED NEW STRINGER SECTION AND SPLICE IAW SRM 53-10-3. (M)SDR AALA972012Spar · crackedTUL - FOUND CRACK IN WING CENTER SECTION REAR SPAR WEB NEAR MILL CUT FROM RBL 3 TO RBL 5, WL 187 APPROX. REPAIRED PER ESO 11697. (M)SDR EISA97209Valve · leakingON TAKEOFF FROM BRU, THE NR 2 FIRE WARNING SOUNDED SHORTLY AFTER TAKEOFF, RETURNED TO BRU (ATB). FOUND UPPER LEFT ANTI-ICE VALVE LEAKING, RESECURED VALVE, AND RAN ENGINE. NO LEAKS NOTED. (X)SDR AALA971995Control · defectiveIAD - FLT 0637 - AFTER TAKEOFF DCA DURING CLIMB-OUT ELECTRICAL ODOR NOTED IN CABIN AND COCKPIT. AIRCRAFT DIVERTED TO IAD AND LANDED WITHOUT INCIDENT. REPLACED HIGH INTENSITY LIGHT CONTROL. SYSTEM GROUND CHECKED, NORMAL OPERATION. (X)
Back to Boeing 727-223