Boeing 737-277
Service difficulty reports · 1,584
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '737277' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '737277' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AWXA9600698Skin · crackedDURING ROUTINE MAINTENANCE CHECK, FOUND LT WING L/E SKIN UPPER SURFACE CORRODED AND CRACKED AT NR 3 SLAT ACTUATOR, 3 INCHES ABOVE CUTOUT. INSTALLED REPAIR ON LT WING L/E SKIN UPPER SURFACE 3 INCHES ABOVE NR 3 SLAT ACTUATOR CUTOUT IAW SRM 57-30-4.SDR AWXA9600665Skin · crackedPHX - CRACK IN FUSELAGE AREA AFT OF WING TO BODY FAIRING, STATION 747 BETWEEN STRINGER 18R AND STRINGER 19R. STRINGER 19R AT DOME NUT PLATE CORRODED AT STATION 747. TERMINATED CRACK APPROXIMATELY 1 INCH BY STOP DRILL. VERIFIED BY HFEC. REPAIRED PER SRM 53SDR AWXA9600660Light · inopPHX - FLT 2267 - FOUND EMERGENCY EXIT LIGHT ON SEAT AT OVERWING EMERGENCY EXIT IS INOPERATIVE. REMOVED AND REPLACED LIGHT ASSEMBLY. OPERATIONS CHECK GOOD. (M)SDR AWXA9600702Floorbeam · corrodedDURING ROUTINE MAINTENANCE CHECK, FOUND CORROSION ON FLOORBEAM STA 987 RBL 16.45 WL 208. REPAIRED FLOORBEAM STA 987 PER ER 2-53-16-44 TCO-PAN-96-1620RR, 8110-3.SDR AWXA9600701Floorbeam · corrodedDURING ROUTINE MAINTENANCE CHECK, FOUND CORROSION ON FLOORBEAM BS 967 RBL 12 TO 18, 55. REMOVED UPPER CHORD FROM FLOORBEAM, BS 967 RBL 55 TO LBL 5. FABRICATED AND INSTALLED REPAIR CHORD IAW AWA ER 2-53-16-44, TCO-PAN-96-1620RR 8110-3.SDR AWXA9600666Battery Pack · dischargedPHX - FLT 2024 - FOUND LEFT OVERWING FLOOR PROXIMITY EMERGENCY LIGHTS INOP. REMOVED AND REPLACED BATTERY PACK, SEAT 20 OVERHEAD. SYSTEM OPERATES NORMALLY. (M)SDR AWXA9600654Power Supply · dischargedCMH - FLT 400 - FOUND VERTICALLY MOUNTED EXIT SIGN AT LEFT OVERWING EXIT INOPERATIVE. REMOVED AND REPLACED POWER SUPPLY. OPERATIONS CHECK NORMAL. (M)SDR AWXA9600653Battery Pack · dischargedFOUND L-2 AND R-2 VERTICAL EMERGENCY EXIT LIGHTS INOPERATIVE. REMOVED AND REPLACED BATTERY PACK. LIGHTS OPERATIONS CHECK GOOD. (M)SDR AWXA9600649Strut · fluid lowPHX - FLT 2887 - AIRPLANE ROLLS OFF TO RIGHT UPON LIFT OFF. FLIGHT CONTROLS ARE NORMAL. WIND CONDITIONS LIGHT. ROLL CONTROL NORMAL AFTER TAKEOFF. CHECKED LEFT STRUT SERVICING AS CREW REQUESTED. FOUND FLUID VERY DIRTY AND QTY LOW. FLUSHED STRUT AND SERVICSDR AWXA960646Battery Pack · dischargedCMH - FLT 400 - DURING ROUTINE MAINTENANCE CHECK, FOUND LEFT OVERWING EMERGENCY LIGHTS INOP. REMOVED AND REPLACED LEFT OVERWING EMERGENCY LIGHT BATTERY PACK. OPERATIONS CHECK GOOD. (M)SDR AWXA960643Battery Pack · dischargedPHX - FLT 2267 - DURING ROUTINE MAINTENANCE CHECK, FOUND VERTICAL EMERGENCY EXIT LIGHTS AT L-2 AND R-2 DOORS INOP. REMOVED AND REPLACED BATTERY PACK AT M1051. OPERATIONS CHECK GOOD. (M)SDR AWXA960611Light · looseLAS - FLT 134 - DURING ROUTINE MAINTENANCE CHECK, FOUND LIGHT ON SEAT 6C IS LOOSE AND HANGING BY THE WIRING. PLACED ON MEL 33-19. REPLACED EMERGENCY LIGHT AT ROW 6 A, B, C. MEL CLEARED. (M)SDR AWXA960600Power Supply · inoperativePHX - FLT 2452 - DURING ROUTINE MAINTENACNE CHECK, FOUND LEFT AND RIGHT AFT EXTERIOR EMERGENCY LIGHTS INOP. REPLACED THE POWER SUPPLY UNIT FOR THE AFT EXTERIOR EMERGENCY LIGHTS, OPS CHECK NORMAL. (M)SDR AWXA960597Light · looseFLT 2684 - PHX - DURING ROUTINE MAINTENANCE CHECK, FOUND EMERGENCY EXIT LIGHT ROW 6C TORN OUT OF SEAT. REPAIRED EMERGENCY EXIT LIGHT AT ROW 6C. OPS CHECK GOOD AT THIS TIME. (M)SDR AWXA960596Wire · brokenPHX - FLT 2245 - DURING ROUTINE MAINTENANCE CHECK, FUOND EMERGENCY LIGHT WIRE BROKEN AT SEAT 14. REPAIRED WIRE. (M)SDR AWXA960595Isolation Valve · inopLAS - FLT 2037 - DURING FLIGHT THE ISOLATION VALVE LIGHT ILLUMINATED, A/C DIVETED TO LAS. LIGHT WENT OUT ON LANDING AND REVERSER WORKED NORMALLY. REPLACED NR 1 ISOLATION VALVE, OPS CHECK NORMALLY AT THIS TIME. (M)SDR AWXA960593Wire · brokenPHX - FLT 90 - DURING ROUTINE MAINTENANCE CHECK, FOUND FIRST 5 ROWS OF EMERGENCY LIGHTS REMAIN DIM AT ALL TIMES. FLICKERED DURING FLIGHT. FOUND OPEN WIRES. REPAIRED WIRES AT ROW 1 AB. OPS NORMAL. (M)SDR AWXA960589Light · loosePHX - FLT 2267 - DURING ROUTINE MAINTENANCE CHECK, FOUND ROW 18 EMERGENCY LIGHTS PULLED LOOSE FROM SEAT. SECURED LIGHT ASSEMBLY. (M)SDR AWXA960632Web · crackedPAE - FLT 7837 - DURING ROUTINE MAINTENANCE CHECK, FOUND SHEAR WEB ON LEFT SIDE CRACKED FROM BS 709 - BS 727 AT STRINGER 18A. FABRICATED AND INSTALLED REPAIR PARTS IAW SRM 51-30-2, ER 2-53-15-51, TCO-PAN-1433RR-1449RR8110-3. (M)SDR AWXA960631Intercostal · corrodedPAE - FLT 7837 - DURING ROUTINE MAINTENANCE CHECK, FOUND CORROSION AT FASTENER HOLE ON INTERCOSTAL STATION 1013, LBL 40. REMOVED AND REPLACED INTERCOSTAL PER SRM 51-30-2. (M)SDR AWXA960630Web · corrodedPAE - FLT 7837 - DURING ROUTINE MAINTENANCE CHECK, FOUND WEB UNDER MOPSILL BS 987-1006, LBL 55 CORRODED. REMOVED, FABRICATED AND INSTALLED NEW WEB IAW SRM 51-30-2, 51-10-1, 51-10-2. (M)SDR AWXA960629Plate · corrodedPAE - FLT 7837 - DURING ROUTINE MAINTENANCE CHECK, FOUND CORROSION ON INTERCOSTAL STATION 997-1006, LBL 10 ON SPACER PLATE. REMOVED, FABRICATED AND INSTALLED SPACER PLATE ON INTERCOSTAL AT STATION 997-1006, LBL 10. (M)SDR AWXA960625Mopsill · corrodedPAE - FLT 7837 - DURING ROUTINE MAINTENANCE CHECK, FOUND CORROSION ON MOPSILL RIGHT STATION 950-1006, WL 208. REMOVED AND REPLACED MOPSILL (CHORD) PER SRM 53-10-1, 51-30-2, 51-10-1. (M)SDR AWXA960578Anti-Ice Vlv · inopPHX - FLT 2590 - ON TAKEOFF ROLL WHEN AUTO THROTTLE ADVANCES LEFT THROTTLE SPLIT WITH RIGHT THROTTLE LEAD EGT NR 1 EMG NEAR RED LINE DISCONNECT FOR AUTO THROTTLE TO BRING LEFT THROTTLE BUT NO HELP EGT STILL GOES TO MAX RED LINE. PERFORMED EPR LEAK TEST ENG NRSDR AWXA960577Engine · fodPHX - FLT 2545 - ON TAKEOFF CREW NOTED SPLIT BETWEEN NR 1 AND NR 2 POWER LEVERS. APPROACHING LEVEL OFF THE NR 1 POWER LEVER LOCKED AT MID POSITION. CREW ELECTED TO SHUT DOWN NR 1 ENGINE AND RETURN TO PHOENIX. PERFORMED LEAK CHECK PT6 AND PT7 ON BOTH ENGINESSDR AWXA960626Floor Beam · corrodedPAE - FLT 7837 - DURING ROUTINE MAINTENANCE CHECK, FOUND CORROSION ON FLOOR BEAM STATION 987, LBL 15, RBL 3 AND RBL 30-35. REMOVED AND REPLACED UPPER CHORD OF FLOOR BEAM FROM LBL 55 TO RBL 55, BS 987, WL 208, PER SRM 51-30-2 AND ER 2-53-15-36, TCO-PAN-96-141RSDR AWXA960620Floor Beam · corrodedPAE - FLT 7837 - DURING ROUTINE MAINTENANCE CHECK, FOUND CORROSION ON FLOOR BEAM BS 1016, LBL 26. REMOVED CORRODED FLOOR BEAM, FABRICATED REPAIR PARTS, AND INSTALLED PER E.R. 2-53-15-50, TCO-PAN-96-1408RR-8110-3. (X)SDR AWXA960624Threshold · corrodedPAE - FLT 7837 - DURING ROUTINE MAINTENANCE CHECK, FOUND CORROSION ON MOP SILL LEFT BS 954-991, WL 208. REMOVED DAMAGED MOPSILL AND INSTALLED NEW MOPSILL IAW SRM 51-10-1, 51-30-2. (M)SDR AWXA960623Floor Beam · corrodedPAE - FLT 7837 - DURING ROUTINE MAINTENANCE CHECK, FOUND CORROSION ON FLOOR BEAM 967, RBL 15-55, WL 208. REPAIRED PER SRM 53-10-9 BY FABRICATING AND INSTALLING UPPER CHORD. (M)SDR AWXA960564Wire · chafedLAS - FLT 134 - DURING TAKEOFF ROLL AT 70 KTS, THE NR 2 ENGINE THRUST REVERSER UNLOCK LIGHT CAME ON WITH NO ACTUAL THRUST REVERSER DEPLOYMENT. CREW ABORTED TAKEOFF. FOUND CHAFED WIRE IN PYLON AREA NEXT TO THE FEEDBACK CABLE DURING ENGINE CHANGE. REPAIRED WISDR AWXA960560Light · missingDURING ROUTINE MAINTENANCE CEHCK, FOUND EMERGENCY LIGHT AT ROW 1 MISSING. REPLACED LIGHT AT ROW 1. OPERATIONS CHECK GOOD. (M)SDR AWXA960563Light · inoperativePHX - FLT 2572 - DURING ROUTINE MAINTENANCE CHECK, FOUND RIGHT R-1 EMERGENCY LIGHT OVER DOOR INOP. REMOVED AND REPLACED EMERGENCY LIGHT ASSEMBLY. (M)SDR AWXA960562Wire · brokenPHX - FLT 2267 - DURING ROUTINE MAINTENANCE CHECK, FOUND SEAT 2-A EMERGENCY LIGHT INOP. REPAIRED WIRING AT SEAT 2-A. SYSTEM OPERATIONS CHECK GOOD. (M)SDR AWXA960628Intercostal · corrodedPAE - FLT 7837 - DURING ROUTINE MAINTENANCE CHECK, FOUND CORROSION AROUND FASTENER HOLES INTERCOSTAL STATION 947-967, RBL 18, WL 208. REMOVED CORRODED INTERCOSTAL AND INSTALLED NEW INTERCOSTAL IAW SRM 51-10-1, 51-30-2 AND SRM 53-10-1. (M)SDR AWXA960627Intercostal · corrodedPAE - FLT 7837 - DURING ROUTINE MAINTENANCE CHECK, FOUND CORROSION AROUND FASTENER HOLES OF INTERCOSTAL STATION 947 TO 967, RBL 10, WL 208. REMOVED AND REPLACED WITH NEW INTERCOSTAL AT BS 947-967, RBL 30, WL 208 PER SRM 51-10-1 AND 51-30-2. (M)SDR AWXA960622Stringer · corrodedFLT 7837 - PAE - DURING ROUTINE MAINTENANCE CHECK, FOUND CORROSION AT BS 907, STRINGER 27R AT STRINGER SPLICE. REPAIRED STRINGER 27 RIGHT, BS 887-927 AS PER SRM 53-10-3. (M)SDR AWXA960621Stringer · corrodedPAE - FLT 7837 - DURING ROUTINE MAINTENANCE CHECK, FOUND STRINGER 27 LEFT AT BS 949 CORRODED. REMOVED, FABRICATED AND INSTALLED REPAIR PARTS PER SRM 53-10-3. (M)SDR AWXA960552L/G Access Unit · inoperativeLAS - FLT 2059 - UPON GEAR RETRACTION, GEAR HANDLE WOULD NOT COME UP PAST OFF POSITION. RECYCLED DOWN THEN LOCK TO UP. HANDLE OPERATED NORMALLY THE SECOND TIME. REMOVED AND REPLACED LANDING GEAR ACCESSORY UNIT PER AIB32001. REMOVED AND REPLACED AIR AND GROSDR AWXA960551Battery · dischargedPHX - FLT 7838 - DURING ROUTINE MAINTENANCE CHECK, FOUND AFT GALLEY SIDEWALL EMERGENCY LIGHTS INOP. REMOVED AND REPLACED BATTERY CARTRIDGE ASSEMBLY. OPERATIONS CHECK GOOD. (M)SDR AWXA960575Skin · crackedPAE - FLT 7824 - DURING ROUTINE MAINTENANCE CHECK, FOUND CRACKS AT FORWARD ENTRY DOOR LOWER SILL AT BS 351 AND BS 303. REPAIRED CRACKS PER EO 53-44-01, PART IV. (M)SDR AWXA960542Flap Pos Xmitter · out of rigPHX - FLT 2647 - SELECTING FLAPS 15 FROM 5, A NOTICEABLE SPLIT OCCURRED CAUSING A SLIGHT ROLL. SPLIT DID NOT EXCEED LIMITS OF WHITE BAND, IMPROVED WHEN SELECTING FLAPS 30. OCCURRED AGAIN WHEN SELECTING FLAPS UP. FOUND LEFT FLAP POSITION TRANSMITTER OUT OF RSDR AWXA960539Battery · dischargedPHX - FLT 7706 - DURING ROUTINE MAINTENANCE CHECK, FOUND THE EMERGENCY LIGHTS WERE LEFT ON. ALL LIGHTS WERE INOP. FERRIED BACK TO PHX. REMOVED AND REPLACED EMERGENCY LIGHT BATTERIES. (M)SDR AWXA960532Light · missingPHX - FLT 2287 - DURING ROUTINE MAINTENANCE CHECK, FOUND SELF ILLUMINATING EXIT SIGN MISSING FROM AFT SIDE OF CLASS DIVIDER. INSTALLED SELF ILLUMINATING LIGHT. (M)SDR AWXA960574Floor Beam · corrodedPAE - FLT 7834 - DURING ROUTINE MAINTENANCE CHECK, FOUND CORROSION AT BS 1016 ON FLOOR BEAM LBL 11 UPPER SURFACE WL 208. REPAIRED IAW, TCO-PAN-96-1353-RR18110-3 AND EO 2-53-16-43. (M)SDR AWXA960566Floor Beam · corrodedDURING ROUTINE MAINTENANCE CHECK, FOUND CORROSION 947 FLOOR BEAM TOP FLANGE, WL 208, RBL 4 AND LBL 4, BOTH TOP AND BOTTOM. FABRICATED, ALODINED AND INSTALLED REPAIR PARTS PER SRM 53-10-9. (M)SDR AWXA960565Floor Beam · corrodedDURING ROUTINE MAINTENANCE CHECK, FOUND CORROSION IN FLOOR BEAM STATION 967, RBL 15-36, WL 208. REMOVED AND REPLACED DAMAGED SECTION OF FLOOR BEAM BS 967-LBL2-RBL57, SRM 53-10-9. (M)SDR AWXA960531Lamp · loosePHX - FLT 7887 - DURING ROUTINE MAINTENANCE CHECK, FOUND EMERGENCY LIGHT SEAT 5 C INOP. FOUND LAMP OUT OF SOCKET. REINSTALLED, LAMP OPERATES GOOD. (M)SDR AWXA960530Light · missingDURING ROUTINE MAINTENANCE CHECK, FOUND ROW 5 EMERGENCY FLOOR PROX SEAT MOUNTED LIGHT MISSING. REPLACED MISSING LIGHT. OPS GOOD. (M)SDR AWXA960573Stringer · crackedPAE - FLT 7824 - DURING ROUTINE MAINTENANCE CHECK, FOUND STRINGER LEFT BS 500 B PLUS 6 STRINGER 16 CRACKED. REMOVED, FABRICATED REPAIR PARTS PER ER 2-53-13-11A AND INSTALLED. (M)SDR AWXA960571Stringer · corrodedPAE - FLT 7824 - DURING ROUTINE MAINTENANCE CHECK, FOUND CORROSION ON STRINGER 26L, BS 907. REMOVED, FABRICATED AND INSTALLED PRODUCTION SPLICE AT BS 907, STRINGER 26L AND REPLACED STRINGER 26L FROM BS 910 TO 937. ALL IAW, SRM 53-10-3. (M)
Back to Boeing 737-277