SDR CALA2017121904530Battery · dischargedFIRST OFFICER FLASHLIGHT WILL NOT TEST. REPLACED FLASH LIGHT BATTERY.SDR UALA2013071805051Lamp · inoperativeLEFT EMERGENCY ESCAPE LIGHT WILL NOT TEST ON P61 PANEL. REPLACED LAMP, OPS NORMAL.SDR UALA2013051603394Skin · damagedFWD GALLEY DOOR CUT OUT CRACKED AT LOWER AFT CORNER NEAR BS 328. FABRICATED AND INSTALLED EXTERNAL FUSELAGE DOUBLER-TRIPLER REPAIR IAW SRM 53-10-01.SDR UALA2012101105780Skin · crackedEXTERNAL SKIN CRACKED BS 947 S11R, CRACK IS JUST FWD OF AFT GALLEY DOOR BODY TORQUE TUBE UPPER CUTOUT. MAJOR REPAIR ACCOMPLISHED, FABRICATED AND INSTALLED EXTERNAL SKIN DOUBLER AND FILLER PER SRM 53-60-014 PG201, THIS REPAIR IS A CLASS 'B' REPAIR.SDR UALA2012101105781Stringer Splice · crackedFUSELAGE STRINGER SPLICE IS CRACKED AT LOWER FLANGE AND UPPER FLANGE BS 360 STR 15L, REMOVED AND REPLACED STRINGER SPLICE IAW EA I070435 AND EVA-70367.SDR UALA2012101105779Inlet · dentedNR 1 ENGINE INLET COWL AT 8:00 O'CLOCK POSITION HAS DENT. ACCOMPLISHED HFEC INSPECTION, NO CRACKS NOTED, CHECKED THE DENT PER SRM 54-10-01 PG 104 DETAIL IV, DENT FOUND WITHIN LIMITS A OVER Y RATIO IS 31. NO ACTION NEEDED OK TO ARCHIVE.SDR UALA2012101105778Plate · dentedDENT IN AFT CARGO THRESHOLD PLATE, APPROX 18 INCH AFT OF FORWARD CUTOUT, AND 4.5 INCH INBD OF LOWER CUTOUT. DENT MEASURES APPROX 1.75 INCH DIAMETER NOT PUNCTURED. DENT IS IN CARGO BAY BOILER PLATE INSIDE OF PIT, NOT THRESHOLD PLATE. DENT IS SMOOTH AND CRACKSDR UALA2012101005746Skin · dentedLEFT FUSE SKIN IS DENTED AT STA 927 BETWEEN STR 19L AND 20L. INSPECTED DENT EXTERNALLY AND INTERNALLY NO OTHER DAMAGE NOTED, NO CRACKS FOUND WITH HFEC. PER MM 51-00-99 D DENT IS CRACK FREE AND IS WITHIN LIMITS OF MM 51-00-99 FOR CONTINUED SERVICE WITHOUT FURTSDR UALA2012072303977Hose · unsecureR BLD DUCT LEAK EICAS AND DUCT LEAK ON OVERHEAD. SECURED RADIATOR HOSE IN AREA OF WATER CONDENSOR LEAK CHECKED OK..SDR UALA2012031301656Bearing · damagedNR 2 PYLON CROWN BEARING ROTATED AND RUSTY. REMOVED & REPLACED BEARING USING ALTERNATE TOOLING. REF SRM54-50-90 & AAR EA 080367. THIS REPAIR IS APPROVED BY FAA FORM 8100-9.SDR UALA2012010300015Floorbeam · corrodedPASSENGER CABIN FLOOR STRUCTURE AT BS 347, BTWN RBL 19 - 40 HAS CORROSION. MAJOR REPAIR ACCOMPLISHED. FOUND CORROSION OUT OF LIMITS, FABRICATED AND INSTALLED TEE, STRAPS, AND ANGLES FROM RBL 19 - RBL 60 PER SRM ON NR 3872N00504.SDR I5EA20111001Bulb · burned outL1 DOOR EXTERIOR EMERGENCY LIGHT INOPERATIVE. R & R L1 DOOR EXTERIOR EMERGENCY LIGHT BULB IAW AMM 33-51-02/21.SDR I5EA20110903Powerpack · inoperativeMIDDLE OVERHEAD EMERGENCY LIGHT WOULD NOT STAY ON.SDR I5EA20110901Battery Pack · dischargedLEFT EMERGENCY LIGHT BATTERY PACK IN AFT GALLEY CEILING IS INOP.SDR UALA20101209001Wire · brokenCEILING AISLE EMERGENCY LIGHTS INOP AT SEATS 7AB AND 8KJ. REPAIRED BROKEN WIRE AT SEATS 7AB AND RESEATED LOOSE PIN AT CONNECTOR AT SEAT 8KJ, OP CHECKS GOOD.SDR UALA2009102303316Slide · dislodgedDOOR 2R SLIDE PACK APPEARS DISLODGED. STOWED SLIDE STRAPS BACK INSIDE SLIDE BUSTLE, NOW OKAY.SDR UALA2009101203200Smoke Detector · faultyFWD LAVATORY SMOKE DETECTOR WARNING, UNEXPLAINED. REPLACED SMOKE DETECTOR.SDR UALA2009092102985Oxygen System · low pressureCREW OXYGEN SYSTEM-LOW. RECORD PRESSURE PRIOR TO SERVICING. SERVICED O2 AT CAPTAIN'S REQUEST.SDR UALA2009090802827Light · inoperativeEEL LIGHTS INOP AFT OF SEAT 21 ABC. REPLACED EEL LIGHT STRIP, LIGHTS OP CHECK OKAY.SDR UALA2009082502635Control Module · faultyENG AND APU FIRE CONTROL MODULE WILL NOT TEST NR 2 ENG AND APU SQUIB. REPLACED APU AND APU FIRE CONTROL MODULE, TESTED GOOD.SDR UALA2009081902545Pin · stuckF-O'S OXYGEN MASK HOLDER PIN IS STUCK IN THE RETRACTED POSITION. REPLACED F/O O2 MASK STORAGE BOX. OPS CK NORMAL.SDR UALA2009081302475Charger · inoperativeEMERGENCY EXIT SIGNS AT DOOR 2R AND BY AFT LAV ARE FLICKERING ON AND OFF. REPLACED EMERGENCY EXIT CHARGER ASSY, CHECKED OKAY.SDR UALA2009081102452Oxygen Mask · leakingCREW OXYGEN SYSTEM-LOW, RECORD PRESSURE PRIOR TO SERVICING. SERVICED TO 1800 PSI. FOUND COCKPIT OBSERVER OXYGEN MASK LEAKING, DISCONNECTED HOSE. REPLACED OBSERVER 02 MASK ASSY. OPS CKS NORMAL.SDR UALA2009080402337Nut · missingWHILE PERFORMING EMERGENCY LIGHT TEST PER JOB CARD FOUND DOOR 2R LIGHT BAD. DURING REPLACEMENT OF BULB FOUND NUT MISSING FOR LIGHT LENS SCREW. REPLACED MISSING NUT.SDR UALA2009080502350Oxygen Mask · malfunctionedCAPTAIN OXYGEN MASK TEST DOES NOT SHOW FULL NORMAL CROSS YELLOW FLOW INDICATION. REPLACED O2 MASK AND BOX, OPS NORMAL.SDR UALA2009080302332Slide · leakingDOOR 2L SLIDE PRESSURE APPROACHING LIMIT. REPLACED SLIDE.SDR UALA2009072902266Wire Harness · shortedLEFT ENG EGT FLUCTUATION, ABORTED TAKEOFF. DUPLICATED EGT FLUCTUATION BY WIGGLING HARNESS. REPLACED HARNESS AND TEST SYS. REPLACED LT EXTENSION HARNESS, LWR LT THERMOCOUPLE HARNESS AND PROBES. RAN ENG, NO FLUCTUATING. OK FOR SERVICE.SDR UALA2009072802249Slide · unserviceableTHE 1L DOOR SLIDE GIRT PULLED DOWN FROM CONTAINER. REPLACED DOOR 1L SLIDE PACK.SDR UALA2009072702239Battery Pack · inoperativeEMERGENCY EXIT SIGNS AT ROW 9L AND 7R EACH HAVE 1 BULB INOP. RELAMP, NO HELP. REPLACED POWER SUPPLY BATTERY PACK. ALL SYSTEMS CHECKED NORMAL.SDR UALA2009072702238Battery Pack · inoperativeEMERGENCY EXIT PATH LIGHTING FROM ROW 3-9 INOP. ALSO LIGHTS ROW 10-12 DIM AMD EXTINGUISH WITHIN 1 MINUTE OF ILLUMINATION. REPLACED POWER SUPPLY BATTERY PACK ON RIGHT SIDE NEAR EMERGENCY EXIT SIGN, ABOVE ROW 10. OP'S CHECKED EMERGENCY LIGHT. TEST NORMAL. EMERGSDR UALA2009072702217Connector · unsecureF/A REPORTS EEL LIGHTS ARE INOP FROM ROW 15 AFT. SECURED AND CLEANED EEL CONNECTOR IN AFT GALLEY FLOOR. ALL LIGHTS CHECKED OKAY.SDR UALA2009072402206Light · unsecureEMERGENCY ROW LIGHT COMING UP ROW 20, 21. FOUND EEL TRACK FEEDER STRIP FAULTED. REPLACED FEED STRIP INSIDE OF TRACK AND OPS CHECKED LIGHTS OK.SDR UALA2009072102155Feeder Cable · disconnectedFLOOR EMERGENCY LIGHT STRIP INOP FROM ROW 3 THRU 10. FOUND FEEDER CABLE DISCONNECTED. RECONNECTED, LIGHT OP CHECKS OKAY.SDR UALA2009072102154Light · inoperativeFLOOR EMERGENCY EXIT LIGHTING INOP FROM SEAT ROW 15-21 AND GALLEY STRIP AFT OF ROW 21. REPLACED LIGHT SEGMENTS.SDR UALA2009072102153Bulb · inoperativeSTOWBIN BULL NOSE EMERGENCY LIGHT INOP BETWEEN ROWS 14 & 15CD. RELAMPED BULB, GROUND TEST OKAY.SDR UALA2009072002129Battery · malfunctionedELECTRICAL SYSTEM ISSUE, FLIGHT DIVERTED. BOTH IRS DC FAIL LIGHTS ILLUMINATED. BATTERY VOLTAGE SLOWLY DROPPED TO 14 VOLTS. REPLACED BATTERY, BATTERY CHARGER AND RELAY R41.SDR UALA2009072002120Light · inoperativeFLOOR EEL LIGHTS FROM ROW 15 AFT INOP. CLEANED CONNECTIONS AT LIGHT STRIP IN AFT GALLEY, OPS CHECKS NORMAL NOW.SDR UALA2009071502094Blades · crackedENGINE THRUST ISSUE, RTFL. REPLACED MEC. FAILED PWR RUN. BORO FOUND 2 STG 5 COMP BLADES CRACKED, ENG CHG ACCOMPLISHED, IDLES & LK CHKS. ENG REPLACED ON ACCT OF CRACKED COMPRESSOR BLADE.SDR UALA2009070801973Unknown · unknownRETURNED TO THE FIELD WITH A STABILIZER TRIM ISSUE. AMBER DECLARED.SDR UALA2009070801964Warning Light · inoperativeF/O FIRE WARNING LIGHT INOP. REPLACED F/O FIRE WARNING LIGHT ASSY L345, OPS TEST OKAY.SDR UALA2009070701951Module · failedSTAB TRIM PROBLEM, RTFL. AFTER TAKEOFF STAB TRIM INOP IN NOSE DOWN POS. RMV COLUMN SWITCH MODULE M1201, FOUND PUSHED BACK PIN ON K4 B2. NEED TO CONTINUE T/S AFTER RPL OF M1201. REPLACED COLUMN CUTOUT SWITCH MODULE. ALSO REPLACED S115 NOSEUP LIMIT SWITCH. SDR UALA2009070701952Control Panel · false indicationCARGO SMOKE DETECTOR CONTROL PANEL GIVES FALSE FAILURES FOR ALL DETECTORS. REPLACED CARGO SMOKE DETECTOR CONTROL PANEL, TESTS GOOD.SDR UALA2009070601911Slide · faultyFWD ENTRY DOOR SLIDE REMOVED. NO SAFETY PIN IN POUCH, PIN NOT STOCKED IN DENVER. AFTER SLIDE INSTALLED NEED FOREMAN BY BACK. REMOVED DOOR 1 LEFT DOOR SLIDE. INSTALLED SAFETY PIN IN POUCH OF SLIDE THAT ARRIVED. REPLACED AND REMOVED DOOR 1L DOOR SLIDE.SDR UALA2009070101886Skin · damagedBEAM PANEL BETWEEN MAIN GEAR WHEEL WELL HAS CRACK. CRACK IS IN BELLY SKIN BETWEEN PANELS, THERE ARE ALSO EXISTING REPAIRS FORWARD AND AFT OF CRACK. REPAIR WILL INVOLVE INCORPORATION WITH EXISTING REPAIRS. INSTALLED NEW PANEL. WRK ACP BY AMTS RECORDED ON WUSDR UALA2009070101889Structure · crackedFOUND CRACK ON E/E COOLING DUCT CUTOUT. LOWER FUSELAGE BS BETWEEN 360-380 AND 28L/R. ACP HFEC OF SUSPECT CRACK IN SKIN AFT OF EQUIP COOLING EXHAUST OPENING. AREA IS CRACKED APPROX ONE HALF INCH LONG FROM EXHAUST OPENING AND TERMINATED AT SCREW FASTENER HOLESDR UALA2009070101883Socket · corrodedRT SIDE OVERWING EMERGENCY ILLUMINATION LIGHT INOP, FOUND SOCKET CORRODED. CLEANED SOCKET, SECURED LAMP, EMERGENCY LIGHTS OKAY.SDR UALA2009062901855Power Strip · inoperativeEMERGENCY EXIT PATH LIGHTING INOP FROM ROW 15 AND BACK. REPLACED POWER STRIP, CHECKS NORMAL.SDR UALA2009062201755Csd · faultyNR 1 GENERATOR FAILURE. FLIGHT DIVERTED. FOUND METAL ON CHIP DETECTOR AND DELTA-P SWITCH WAS POPPED ON CASE DRAIN FILTER. REPLACED NR 1 CSD, CASE DRAIN FILTER AND CSD OIL COOLER. APU STARTED NORMAL ON MANY ATTEMPTS, ALSO STARTED ENGINES THREE TIMES AND LOASDR UALA2009062301770Oxygen Bottle · low pressureCREW REPORT: CREW O2 GAUGE READS LOW. FOUND BOTTLE PRESSURE READING APPROX 200 PSI. SERVICED BOTTLE TO 1800 PSI & VERIFIED NO LEAKS. CREW O2 IS OKAY FOR SERVICE.SDR UALA2009061701729Fire Detector · faultyFWD CARGO PIT LOOP B FAIL LIGHT FLICKERS DURING TAXI. DUPLICATED PROBLEM AS REPORTED. FOUND CHAFED WIRES TO GND BEHIND CARGO FIRE DET PANEL IN E&E BAY. THE 1B DETECTOR REPLACED. CHECKED WIRES AND FOUND NO STRAND DAMAGE. ACCOMPLISHED INSULATION REPAIR. SE
Back to Boeing 737-322