Boeing 737-322
Service difficulty reports · 4,751
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '737322' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '737322' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 2007UALA03163Light · contaminatedEEL LIGHTING STRIP INOP FROM SEAT 15 ABC TO THE REAR GALLEY. FOUND EEL STRIP NEAR THE GALLEY IN WATER, SHORTING EEL STRIP. REPLACED EEL POWER STRIP AND TWO EEL LIGHTING STRIPS. EEL LIGHTING, OP CHECKS OK.SDR 2007UALA03133Light · inoperativeFLOOR EMERGENCY EXIT LIGHTS 21 ABC INOP. REPLACED STRIP.
SDR 2007UALA03135Oxygen Mask · damagedFLIGHT DECK CREW'S FIRST OBSERVER'S OXYGEN MASK DAMAGED AND WILL NOT PASS TEST.SDR 2007UALA03132Slide · out of positionDOOR 1L SLIDE PACK FELL OUT OF HOLDER WHEN DOOR WAS OPENED. SLIDE DID NOT DEPLOY.SDR 2007UALA03130Pin · missingAFT GALLEY DOOR HAS MISSING SLIDE PIN NEAR GIRT.SDR 2007UALA03129Door Frame · crackedFWD GALLEY DOOR LOWER FWD FRAME IS CRACKED AT 2 EA FASTENER HOLES. MAJOR REPAIR ACCOMPLISHED.SDR 2007UALA03123Light · unknownAFT CABIN DOOR EMERGENCY EXIT LIGHTS WILL NOT TURN OFF. NO FAULT FOUND.SDR 2007UALA03138Cable · faultyAFT CABIN EEL LIGHTS FROM ROW 15 AFT TO AND INCLUDING EEL STRIP IN FRONT OF AFT GALLEY CART STOWAGE COMPARTMENT ARE INOP. REPLACED CABLE FROM ROW 15 TO 21. ALL SYSTEMS CHECKED GOOD.SDR 2007UALA03137Light · inoperativeEXTERIOR EMERGENCY OVERWING LIGHT, AFT OF LEFT WING TRAILING EDGE ON SIDE OF FUSELAGE INOP. RELAMPED OVERWING LIGHT.SDR 2007UALA03136Oxygen Mask · faultyCAPTAIN'S OXYGEN MASK RUNS CONTINUOUSLY IN RESET TEST.SDR 2007UALA03128Skin · damagedAFT CARGO DOOR CUTOUT STA 847 STR 22, PREVIOUS REPAIR REMOVED FOR SKIN REPLACEMENT. MAJOR REPAIR ACCOMPLISHED.SDR 2007UALA03155Oxygen System · low pressureCREW OXYGEN SYSTEM LOW. INSPECTED AND LEAK CHECKED ALL 3 MASKS. NOTED OBSERVER MASK INCORRECTLY STOWED AND POSSIBLE TEST BEING INADVERTENTLY PUSHED. SERVICED O2 TO 1800.SDR 2007UALA03134Oxygen Mask · damagedCAPTAINS OXYGEN MASK REGULATOR DAMAGED AND DOES NOT TEST PROPERLY.SDR 2007UALA03127Skin · crackedFWD ENTRY DOOR CRACK ON INNER SKIN AND FRAME AFT SIDE AT SEVENTH STOP FITTING FROM TOP. MAJOR REPAIR ACCOMPLISHED: FABRICATED & INSTALLED DOUBLER/ANGLE REPAIR.SDR 2007UALA03089Skin · delaminatedNR 4 SLAT UPPER TRAILING EDGE SURFACE HAS DELAMINATION APPROX FIVE INCHES LONG AND SIX INCHES WIDE STICKING UP AT FORTY FIVE DEGREE ANGLE. PERFORMED COMPOSITE REPAIR ON NR 2 PYLON FAIRING.SDR 2007UALA03088Fitting · crackedFITTING CRACKED, LEFT MLG O/B AFT SUPPORT FITTING IS CRACKED AT THE NR 2 BOLT HOLE AT THE 6:00 POSITION.SDR 2007UALA03081Disk · damagedFOUND 1 RT DOOR SLIDE GAUGE OUT GREEN. FOUND RUPTURE DISK HAS SMALL PIN HOLE LEAK. REPLACED DISK, REFILLED BOTTLE AND CHECKED FOR LEAKS.SDR 2007UALA03077Lamp · burned outEXTERIOR EEL LIGHT BY DOOR 1L IS INOP. RELAMPED OPS CK OK.SDR 2007UALA03076Light · inoperativeFOUND EEL LIGHT IN INOP BY FWD COAT CLOSET IN FIRST CLASS. REPLACED LIGHT.SDR 2007UALA03072Angle · crackedFOUND PASSENGER CABIN STA 290 JUST BELOW STR 11R ANGLE CRACKED. MAJOR REPAIR ACCOMPLISHED: REMOVED CRACKED ANGLE. REPLACED WITH NEW ANGLE (REF SRM 51-40-02 PGS 1-2-6)SDR 2007UALA03071Frame · crackedFOUND OVERWING FRAME INNER CHORD IS CRACKED AT BS 616L, JUST BELOW STR 17. MAJOR REPAIR ACCOMPLISHED: REPAIRED FRAME INNER CHORD AT STA 616L BELOW S17L WITH STIFFENER ANGLE AND FILLER.SDR 2007UALA03066Floorbeam · corrodedFLOORBEAM CORRODED: CABIN BS 294.5, LBL 6-7 WATERLINE 208, UPPER FLANGE CAP. REMOVED CORROSION. FABRICATED AND INSTALLED REPAIR ANGLE AND SHIM.SDR 2007UALA03064Window · failedRTFL DUE TO FIRST OFFICER'S SHATTERED WINDOW.SDR 2007UALA03050Unknown · smokeAFTER LANDING SMOKE REPORTED COMING FROM RT OUTBD MLG BRAKE AREA.SDR 2007UALA03062Indicator · malfunctionedLANDED UNDER AMBER ALERT DUE TO NO FLAP MOVEMENT. FOUND FLAP POSITION INDICATOR FAILURE. REPLACED THE FLAP POSITION INDICATOR. FLAPS CYCLED THROUGH SEVERAL TIMES. ALL SYSTEMS NOTED NORMAL.SDR 2007UALA03053Torque Link · damagedNOSE WHEEL SHIMMY AT TAXI SPEEDS, NORMAL AT HIGH SPEEDS. NOSE WHEEL TORQUE LINKS WORN BEYOND LIMITS CAUSING LOW SPEED SHIMMY. REPLACED BOTH NOSE LANDING TORSION LINKS, PERFORMED TAXI TEST,SDR 2007UALA03052Light · inoperativeEEL STRIP INOP FROM SEAT ROW 18 AFT. REPLACED EEL LIGHT POWER STRIP AND GALLEY LAMP ASSY, ALL EEL LIGHTS OPERATE NORMAL.SDR 2007UALA03022Wire · burnedNR 1 ENGINE FUEL FLOW. FOUND BURNED WIRE AT FIREWALL CONNECTOR.SDR 2007UALA03024Doubler · peelingNR 5 LEADING EDGE SLAT TRAILING EDGE WEDGE, UNDER SIDE HAS OLD HOT BOND METAL PATCH PEELING OFF. PATCH IS 4 X 4 INCH. PATCH IS JUST INBOARD OF SLAT ACT ON UNDER SIDE OF SLAT. DELAM IS LOCATED 59 INCHES FROM INBOARD EDGE OF NR 5 SLAT ON THE TRAILING EDGE WEDSDR 2007UALA03016Light · unsecureEMERGENCY EXIT LIGHT STRIP CAME UP BY LAST ROW OF COACH. REPLACED APPROX 4 FEET OF AFT EEL TRACK COVER & INSTALLED END CAP.SDR 2007UALA03013Cable · faultyEEL STRIP IN FRONT OF AFT GALLEY CART STOWAGE COMPARTMENT INOP AND EEL LIGHTS ROWS 15-21 ARE DIM. REPLACED CABLE.SDR 2007UALA03009Door Frame · crackedFWD CARGO DOOR CUTOUT FWD FRAME IS CRACKED AT LOWER BOTTOM STOP FITTING OUTBOARD LOWER CORNER. MAJOR REPAIR ACCOMPLISHED: REMOVED CARGO COMPARTMENT COMPONENTS TO ACCESS FRAME REPAIR, FABRICATED DOUBLERS, NDT, INSTALLED DOUBLERS, RIG DOOR, OPS CHECK DOOR SWITSDR 2007UALA03007Door Frame · crackedAFT CARGO DOOR CUTOUT AFT FRAME IS CRACKED AT LOWER BOTTOM STOP FITTING OUTBOARD LOWER CORNER AROUND BOTTOM FASTENER. MAJOR REPAIR ACCOMPLISHED: REPLACED AFT CARGO PIT AFT FRAME AROUND DOOR CUTOUT.SDR 2007UALA03027Controller · failedCREW REPORT: F/O'S SLIDING WINDOW ARCING SMOKING & GLASS SPIDER WEB CRACKING. C/B`S DID NOT POP HAD TO REMOVE ELEC POWER WITH WINDOW HEAT SWITCHES. FOUND WINDOW HEAT CONTROLLER FAILURE. REPLACED FO'S SLIDING WINDOW AND ASSOCIATED WINDOW HEAT CONTROLLER.SDR 2007UALA03014Light · contaminatedFLOOR PROXIMITY LIGHTING INOP FROM ROW 16 AFT TO AFT GALLEY. CLEANED & DRIED PROXIMITY LIGHTS. TESTED GOOD.SDR 2007UALA03011Oxygen Mask · faultyOBSERVERS OXYGEN MASK HARD TO BREATH THROUGH.SDR 2007UALA03008Attach Angle · crackedANGLE CRACKED, PASS CABIN FWD OF GALLEY DOOR STA 290 JUST ABOVE STR 10R, INTERCOSTAL WEB ATTACH ANGLE CRACKED. MAJOR REPAIR ACCOMPLISHED: REPLACED CRACKED ANGLE.SDR 2007UALA03006Angle · crackedPASSENGER CABIN STA 290 JUST ABOVE STR 11R ANGLE CRACKED. MAJOR REPAIR ACCOMPLISHED: REMOVED CRACKED ANGLE. REPLACED WITH NEW ANGLE.SDR 2007UALA03029Frame · crackedFWD CARGO DOOR CUTOUT AFT FRAME IS CRACKED ON FWD SIDE IN THREE PLACES. AFT SIDE ON TOP OF CREASE, FWD SIDE AT BOTTOM OF STOP FITTING, UPPER CORNER OF STOP FITTING, O/B LOWER CORNER OF STOP FITTING AND THROUGH I/B LOWER BOLT HOLE OF STOP FITTING AFT SIDE CRACSDR 2007UALA03012Harness · frayedCAPTAIN'S O2 MASK HARNESS IS FRAYED. REPLACED CAPTAIN'S O2 MASK.SDR 2007UALA03010Light · inoperativeEMERGENCY AISLE LIGHT IN BULLNOSE AT ROW 1 2 INOP. RELAMPED EMERGENCY LIGHT.SDR 2007UALA03005Doubler · damagedSTRUCTURE AT STR 12R STATION 518.5 IS DAMAGED. MAJOR REPAIR ACCOMPLISHED: REPLACED DOUBLER.SDR 2007UALA03004Stringer Splice · crackedFWD CABIN LT AT STR 15L SPLICE CHANNEL IS CRACKED AT LWR FLANGE AT BS 360. MAJOR REPAIR ACCOMPLISHED: REPLACED SPLICE CHANNEL.SDR 2007UALA03003Fitting · crackedINTERCOSTAL WEB TO FRAME TIE CLIP AT STATION 360 AND STR 10L IS CRACKED. MAJOR REPAIR ACCOMPLISHED: REPLACED FRAME TIE CLIP AT STA 360 STR 10L.SDR 2007UALA03002Door · crackedFWD ENTRY DOOR HAS 2 EA HOLES WITH CRACK INDICATIONS ABOVE AND BELOW FWD END OF LOWER HINGE CUTOUT. REPAIRED.SDR 2007UALA03001Door · crackedFWD ENTRY DOOR HAS 2 EACH FASTENER HOLES WITH CRACK INDICATIONS ABOVE AND BELOW FWD END OF UPPER HINGE CUTOUT, MARKED. REPAIRED DAMAGED FASTENER HOLES ABOVE AND BELOW UPPER HINGE CUTOUT.SDR 2007UALA03000Skin · chafedUPPER FUSE SKIN CHAFED BELOW RT SIDE SECTION OF DORSAL FIN BETWEEN STA 887 AND 1006. MAJOR REPAIR ACCOMPLISHED: BLENDED DAMAGE AND INSTALLED WEAR STRIPS.SDR 2007UALA02999Skin · chafedUPPER FUSE SKIN CHAFED BELOW LT SIDE SECTION OF DORSAL FIN BETWEEN STA 887 AND 1006. MAJOR REPAIR ACCOMPLISHED: BLENDED DAMAGE. INSTALLED WEAR STRIPS.SDR 2007UALA02998Door Frame · crackedEXTERNAL FUSELAGE FWD CARGO DOOR CUTOUT FRAME. FWD CARGO DOOR CUTOUT AFT FRAME IS CRACKED ON FWD SIDE IN THREE PLACES. AFT SIDE ON TOP OF CREASE, FWD SIDE AT BOTTOM OF STOP FITTING, UPPER CORNER OF STOP FITTING, OB LOWER CORNER OF STOP FITTING AND THROUGH IB SDR 2007UALA02997Stiffener · corrodedBEHIND FWD LAV SERVICE PANEL HAS CORROSION. MAJOR REPAIR ACCOMPLISHED: REPLACED THE FWD LAV SERVICE PANEL STIFFENER & HAT CHANNEL.