SDR 2008UALA03708Flap System · inoperativeLEADING EDGE FLAPS FAILED TO RETRACT. FLIGHT DIVERTED. REPLACED FLAP SLAT ACCESSORY UNIT. SHOP FINDINGS: NO FAULT FOUND.SDR 2008UALA03737Line · leakingCREW OXYGEN SYSTEM LOW. RECORD PRESSURE PRIOR TO SERVICING. *S/D* FOUND CAPTAINS SUPPLY FLEX LINE TO MASK BOX LEAKING. REPLACED FLEX LINE, OP CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA03716Light · brokenEEL STRIP LOOSE AT ROW 22. *S/D* FOUND BROKEN LIGHT STRIP. REPAIRED LIGHT ASSEMBLY, OP CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA03672Feeder Cable · damagedEEL LIGHTS INOP ROW 15 & AFT. FOUND LEAD CABLE AND LIGHT STRIP BAD. REPLACED LEAD CABLE AND LIGHT SEGMENT OP CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA03653Smoke Detector · false activationCREW REPORT: AFT LAV SMOKE DETECTOR GOES OFF INTERMITTENTLY. FOUND FAULTY SMOKE DETECTOR. REPLACED SMOKE DETECTOR OP CHECKED GOOD. AC OK FOR SERVICE.
SDR 2008UALA03635Bulb · inoperativeRIGHT EXT OVERWING EXIT EMERGENCY LIGHT INOP. FOUND BURNED OUT LAMP. REPLACED LAMP OP CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA03636Feeder Cable · faultyEEL LIGHTS INOP ROWS 10-14. REPLACED FEEDER CABLE.SDR 2008UALA03615Oxygen Mask · faultyCAPTAIN'S OXYGEN MASK DOOR LATCH DOES NOT WORK PROPERLY. SUSPECT PRE FLIGHT CHECKS. REPLACED OXYGEN MASK BOX ASSEMBLY OP CHECKED GOOD. AC OK FOR SERVICE.SDR UALA2008111303520Valve · stuckLOSS OF AIR MODE INFLIGHT. RTFL. *S/D* FOUND LANDING GEAR SAFETY SWITCH TELEFLEX CABLE CLEVIS BOLT LOOSE AND CABLE GUIDE BENT AT RT MLG CONNECTION. DISCONNECTED TELEFLEX CABLE AT GEAR AND CABLE IS EXTREMELY HARD TO OPERATE MANUALLY, FEELS LIKE IT IS BIRDCSDR 2008UALA03567Smoke Detector · faultyFA REPORTS SMOKE DETECTOR IN AFT RT LAV GOING OFF FOR NO APPARENT REASON. SUSPECT FAULTY SMOKE DETECTOR. REPLACED SMOKE DETECTOR OP CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA03565Smoke Detector · intermittentSMOKE DETECTOR INTERMITTENTLY SOUNDING IN AFT RIGHT LAV. SUSPECT FAULTY SMOKE DETECTOR. REPLACED DETECTOR OP CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA03520Unknown · malfunctionedLOSS OF AIR MODE INFLIGHT. RTFL.SDR 2008UALA03516Microphone · inoperativeCREW REPORTS THE CAPT'S O2 MASK MICROPHONE IS INOP. SUSPECT FAULTY MASK. REPLACED MASK OP CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA03517Light · looseEXIT PATH LIGHTING AT REAR OF CABIN HAS COME LOOSE. LIGHT ASSEMBLY BROKEN AND LOOSE. REPLACED LIGHT ASSEMBLY OP CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA03515Oxygen Mask · leakingCREW REPORT: F-O O2 MASK INFLATABLE HARNESS LEAKING - NOTE: OBSERVER AND CAPT MASKS ARE GOOD. SWAPPED FO'S MASK WITH FIRST OBS MASK. FO'S MASK CHKS OK PER MM35-12-86. FIRST OBS SEAT INOP. REPLACED FIRST OBS SEAT MASK REF MM 35-12-86. AC OK FOR SERVICE.SDR 2008UALA03526Lamp · inoperativeLEFT EMERGENCY EXIT WING LIGHT IS INOP. FOUND BURNED OUT LAMP. REPLACED LAMP OP CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA03500Oxygen Mask · leakingCREW OXYGEN SYSTEM LOW. RECORD PRESSURE PRIOR TO SERVICING. SUSPECT PRE FLIGHT CHECKS. LEAK CHECKED O2 BOTTLES, MASK BOX. SUSPECT CAPTAINS O2 MASK. SWAPPED OBSERVERS MASK WITH CAPTAIN'S MASK. REPLACED OBSERVERS MASK WITH NEW MASK SERVICED O2 TO 1800 PSI. ASDR 2008UALA03482Skin · dentedRAMP REPORTED DENT AFT OF DOOR 2 LEFT. FOUND DENT TO BE IN SKIN LAP, LOCATED BETWEEN STATIONS 986 AND 1006. REMOVED & REPLACED DAMAGED STRINGER SECTION JUST AFT OF DOOR 2L BETWEEN STR'S 986 AND 1006. NEW STRINGER INSTALLED CLOSING SKIN LAP. WORKING FASTENER SDR 2008UALA03439Engine · making metalENGINE 2 COMPRESSOR STALL ON TAKEOFF 95 PERCENT N1 TARGET, SERIES OF LOUD BANGS, ASSOCIATED YAW, EGT THRU 725 DEGS. RETARDED THROTTLES. THE ACFT BEHIND REPORTED FLAMES FROM ENGINE EXHAUST. FOUND METAL FOUND IN TAILPIPE. CHANGED ENGINES.SDR 2008UALA03430Module · false indicationWITH POWER OFF CARGO FIRE DETECTION PANEL LIGHTS ARE ON. FOUND FAULTY DETECTION PANEL. REPLACED CARGO FIRE DETECTION PANEL REF MM 26-00-02. OPS CHECK GOOD. AC OK FOR SERVICE.SDR 2008UALA03416Lamp · burned outNR 2 FIRE HANDLE LIGHT OUT. FOUND BURNED OUT LAMP. REPLACED LAMP OP CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA03415Unknown · malfunctionedPRESSURIZATION PROBLEM. RTFL. REPLACED S106 AND S805. OPS CHECK GOOD.SDR 2008UALA03428Skin · crackedFUSELAGE SKIN CRACKED LEFT SIDE OF FUSELAGE AT STATION 510 BETWEEN WINDOWS.SDR 2008UALA03393Structure · crackedDURING SCRIBE LINE NDT "EQ1850" A CRACK INDICATION WAS NOTED USING HFEC INSP NDT PART 6. SCANNER PROBE AT LOCATION S-4R, STA 727+57 (AREA MARKED). STANDARD STD-1831 USED, INDICATION LARGER THAN LOCATION C ON STD. REPAIR BEFORE FURTHER FLIGHT.SDR 2008UALA03382Control Panel · faultyRIGHT BOTTLE DISCHARGE LIGHT FAILS TO COME ON WHEN PRESSED. CREW COMMENTS: LEFT TEST-ONLY L & APU TEST. RIGHT TEST - ONLY APU TEST. FOUND FAULTY TEST PANEL. REPLACED FIRE CONTROL PANEL REF MM26-21-51 OP CHECKS OK. AC OK FOR SERVICE.SDR 2008UALA03381Light · burned outDOOR 2R EXTERIOR EMERGENCY ESCAPE SLIDE LIGHT INOP. FOUND LIGHT BURNED OUT AND FUSE BLOWN. REPLACED LIGHT ASSEMBLY AND FUSE OP CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA03429Lamp · inoperativeEMERGENCY ESCAPE PATH FLOOR LIGHTING INOP FROM ROW 15 BACK. FOUND BURNED OUT LIGHT STRIPS. REPLACED LIGHT STRIPS OP CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA03380Structure · crackedTHE 520 STR 12L HAS DAMAGE. MAJOR REPAIR ACCOMPLISHED: MANUFACTURED & INSTALLED 1EA DOUBLER, 1EA TRIPLER AND APPLIED PRIMER.SDR UALA2008111303354Skin · wornRT WING FIXED LEADING EDGE SKIN IS WORN. PER UA-EVA-71666 DAMAGED AREA BLENDED OUT PER SRM 57-41-01. PERMANENT REPAIR TO BE ACCOMPLISHED WITHIN 200 FLT HOURS.SDR 2008UALA03346Battery Pack · faultyCREW REPORTS, THE EMERGENCY EXIT LIGHTS ARE ON WITH THE DISARM SWITCH IN THE DISARM POSITION. REPLACED S7 EMERGENCY EXIT LIGHT SWITCH ON P5 OVERHEAD PANEL,REPLACED 2 EACH BATTERY PACKS AT FWD GALLEY OVERHEAD AREA, REF WDM 33-51-11. OP CHECKS OK REF MM 33-51-SDR 2008UALA03339Unknown · odorACRID SMOKEY SMELL RETURNED UPON LANDING.SDR 2008UALA03325Wedge · delaminatedMID FLAP T/E WEDGE IS DELAMINATED 47.5 INCHES OUTBOARD FROM INBOARD EDGE AND IS DENTED ON LOWER SURFACE DUE TO BIRD STRIKE. FOUND DAMAGE TO BE OUT OF LIMITS. REPLACED LT I-B MID FLAP WEDGE REF MM 27-51-11 PG 406, ALL GAPS CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA03324Skin · damagedLEFT INBOARD AFT FLAP CREASED FROM BIRD STRIKE. FOUND DAMAGE OUT OF LIMITS. REPLACED LEFT IB AFT FLAP REF MM 27-51-11 PG 401, ALL GAPS CHECKED WITHIN LIMITS, OPS CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA03316Panel · no testCARGO FIRE SYSTEM WILL NOT TEST - PANEL BLANK.SDR UALA2008111303292Engine · making metalNR 1 ENGINE FLAMEOUT ON TAXI OUT. THE NR 1 ENGINE WAS REPORTED TO HAVE FLAMEOUT DURING TAXI OUT FOR A MAINTENANCE TEST FLIGHT. UPON RETURN TO THE BASE, METAL WAS FOUND IN THE TAIL PIPE AND THE ENGINE WAS REPORTED SEIZED. THE ENGINE WAS REPLACED. NO ADDITIOSDR 2008UALA03292Engine · flamed outNR 1 ENGINE FLAMEOUT ON TAXI OUT.SDR 2008UALA03290Window · arcedCAPTS L2 WINDOW BEGAN ELECTRICAL ARCING AT POINT OF WIRING EMBEDDED BETWEEN PANES.SDR 2008UALA03269Power Supply · faultyRAMP REPORTS FLOOR LEVEL EMERG 'EXIT' LIGHTS ARE ON AT BOTH AFT DOORS, UPPER 'EXIT' LIGHT IS ON ABOVE DOOR 2LT, AND RT FUSE SLIDE LIGHT ALSO ON. REPLACED BATTERY POWER SUPPLY ASSEMBLY.SDR 2008UALA03279Overheat Loop · faultyFOUND WING OVERHEAT LOOP M1204 BAD. SUSPECT IMPROPERLY INSTALLED. REPLACED RT OVERHEAT LOOP ENGINE PYLON IAW MM26-18-11. OP CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA03247Unknown · odorCREW REPORT: F/A REPORT ELECTRICAL BURN SMELL FROM FWD COFFEEMAKER AREA.SDR 2008UALA03241Radar · failedWX FAILED IN FLIGHT. RTFL. REPLACED WEATHER RADAR TRANSCEIVER. SHOP FOUND ANTENNA AZ FAULT IN F.M.. INSTALLED S.B RTA-4B-34-113 ON ANT. DRIVE MODULE.SDR UALA2008111303278Control Panel · damagedCOFFEE SPILLED ON CENTER CONSOLE IN COCKPIT. FLUID GOT ONTO CARGO FIRE SUPPRESSION PANEL ONLY AND DOES NOT TEST. BOTH CARGO FIRE BOTTLES ARE BLOWN. REPLACED CONTROL PANEL, NO HELP. REPLACED BOTH CARGO PIT FIRE SUPPRESSION BOTTLES, DIVERTER VALVE, METERING SDR 2008UALA03258Structure · dentedUPPER LT FUSELAGE STA 948 S-14 IS DENTED. MAJOR REPAIR ACCOMPLISHED: REMOVED DENT DAMAGE. VERIFIED DAMAGE RMVLD WITH HFEC. INSTALLED TRIPLER/DOUBLER/FILLER REPAIR.SDR 2008UALA03257Structure · crackedFWD ENTRY DOOR UPPER FUSELAGE HINGE CUTOUT HAS ONE EACH FASTENER HOLE WITH CRACK INDICATION AT BS 303 AND STRINGER S-10L. MAJOR REPAIR ACCOMPLISHED: REMOVED DAMAGE. VERIFIED REMOVAL WITH HFEC. INSTALLED DOUBLER/FILLER REPAIR.SDR 2008UALA03256Structure · damagedSTA 279 STR 8L HAS DAMAGE. MAJOR REPAIR ACCOMPLISHED: CUT OUT DAMAGE AND INSTALLED SINGLE DOUBLER REPAIR.SDR 2008UALA03255Intercostal · crackedINTERCOSTAL CRACKED STA 294 AT STRINGER 12L. MAJOR REPAIR ACCOMPLISHED: REPLACED INTERCOSTAL WEB.SDR 2008UALA03254Shear Tie · crackedFWD ENTRY DOOR CUTOUT FWD SIDE WEB FWD ATTACH POINT & INBOARD RADIUS CRACKED AT BS 294.5 AND STRINGER S-7L. MAJOR REPAIR ACCOMPLISHED: REPLACED SHEAR TIE.SDR 2008UALA03253Intercostal · crackedINTERCOSTAL WEB CRACKED AT STRINGER S-16L BETWEEN BS 294.5 AND 303.9 FWD OF 1L ENTRY DOOR. MAJOR REPAIR ACCOMPLISHED: REPLACED INTERCOSTAL WEB.SDR 2008UALA03252Attach Fitting · crackedINTERCOSTAL WEB FWD LOWER ATTACH CLIP CRACKED AT FWD INBOARD CORNER AT STRINGER S-11L BETWEEN BS 294.5 AND 303.9 FWD OF 1L ENTRY DOOR. MAJOR REPAIR ACCOMPLISHED: REPLACED INTERCOSTAL WEB.SDR 2008UALA03251Stringer Clip · crackedFWD ENTRY DOOR CUTOUT AFT SIDE AT BS 360 STRINGER 16L END PIECE CRACKED. MAJOR REPAIR ACCOMPLISHED: REMOVED & REPLACED WITH NEW STRINGER CLIP.