Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7373S1' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7373S1' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR F3LA200100028Floor Support · corrodedDURING C-4 CHECK, INSPECTION REPORTED AFT FUSELAGE FLOOR SUPPORT CORRODED AT LBL 12, BETWEEN STA 947.5 AND STA 967. MAINTENANCE FABRICATED AND INSTALLED REPLACEMENT FLOOR SUPPORT PER EA 53-737-113.SDR F3LA200100027Floorbeam · corrodedDURING C-4 CHECK, INSPECTION REPORTED CORROSION ACROSS TOP OF AFT FUSELAGE FLOORBEAM INTERCOSTAL CAP, STA 951.5, BETWEEN 26 LBL AND 50 LBL. MAINTENANCE REMOVED FLOORBEAM INTERCOSTAL, AND FABRICATED, PRIMED AND INSTALLED REPLACEMENT FLOORBEAM INTERCOSTAL PER ESDR F3LA200100026Floor Support · corrodedDURING C-4 CHECK, INSPECTION REPORTED CORROSION ON AFT FUSELAGE FLOOR SUPPORT AT LBL 3, STA 947.5 TO 967. MAINTENANCE REMOVED AFT FUSELAGE FLOOR SUPPORT, TREATED, PRIMED AND INSTALLED NEW FLOOR SUPPORT PER EA 53-737-113.SDR F3LA200100025Floor Support · corrodedDURING C-4 CHECK, INSPECTION REPORTED CORROSION ON AFT FUSELAGE FLOOR SUPPORT AT LBL 24, STA 947.5 TO 967. MAINTENANCE REMOVED AFT FUSELAGE FLOOR SUPPORT, TREATED, PRIMED AND INSTALLED NEW FLOOR SUPPORT PER SRM 53-60-51.SDR F3LA200100024Floorbeam · corrodedDURING C-4 CHECK, INSPECTION REPORTED CORROSION ON AFT FUSELAGE FLOORBEAM AT STA 947.5. MAINTENANCE REMOVED FLOORBEAM, FABRICATED, TREATED, PRIMED AND INSTALLED REPLACEMENT FLOORBEAM PER SRM 53-00-51.SDR F3LA200100023Crease Beam · corrodedDURING C-4 CHECK, INSPECTION REPORTED CORROSION AT AFT ENTRY DOOR THRESHOLD, STA 986. MAINTENANCE REMOVED CREASE BEAM, CLEANED UPPER AND LOWER SURFACE BELOW CREASE BEAM, BURNISHED LIGHT SURFACE CORROSION AND FOUND TO BE WITHIN LIMITS. REMOVED DAMAGED DOUBLERSDR F3LA200100022Floor Support · corrodedDURING C-4 CHECK, INSPECTION REPORTED CORROSION ON FUSELAGE STRUCTURE AT AFT GALLEY LOWER DOOR FRAME, STA 990 - 1006. MAINTENANCE REPLACED MOP SILL AND WEB PER SRM 51-40-02, 51-10-02 AND 51-20-05.SDR F3LA200100021Web · corrodedDURING C-4 CHECK, INSPECTION REPORTED WEB CORRODED AT LT SIDE OF FUSELAGE, AFT OF STA 986.5, FWD OF PRESSURE WEB. MAINTENANCE FABRICATED AND INSTALLED REPLACEMENT WEB PER SRM 53-60-15, 51-40-02 AND SOPM 20-41-02.SDR F3LA200100018Floor Support · corrodedDURING C-4 CHECK, INSPECTION REPORTED CORROSION ON AFT FUSELAGE FLOOR SUPPORT, 14 INCHES LT OF CENTER LINE 0, BETWEEN STA 967 AND 986.5. MAINTENANCE INSTALLED INTERCOSTAL PER SRM 51-40-02.SDR F3LA200100020Floor Support · corrodedDURING C-4 CHECK, INSPECTION REPORTED CORROSION ON AFT FUSELAGE FLOOR SUPPORT, 14 INCHES RBL, BETWEEN STA 967 AND 986.5. MAINTENANCE FABRICATED AND INSTALLED REPLACEMENT FLOOR SUPPORT PER SRM 51-10-02, 51-40-02 AND EA 53-737-113.SDR F3LA200100019Floor Support · corrodedDURING C-4 CHECK, INSPECTION REPORTED CORROSION ON AFT FUSELAGE FLOOR SUPPORT, 2 INCHES FROM LT CENTER LINE 0, BETWEEN STA 986.5 AND 967. MAINTENANCE INSTALLED WEB BETWEEN STA 986.5 AND 967 PER SRM 51-10-2 AND REPLACED FLOORBEAM CAP AT STA 967 PER SRM 53-00-5SDR F3LA200100017Floorbeam · corrodedDURING C-4 CHECK, INSPECTION REPORTED CORROSION ACROSS TOP OF AFT FUSELAGE FLOORBEAM AT STA 967. REPLACED FLOORBEAM CAP AT STA 967 FROM LBL 37.5 TO RBL 36 PER SRM 53-00-51.SDR F3LA00188Floor Panel · crackedDEN - PRIOR TO DEPARTURE, MAINTENANCE REPORTED HOLE IN AFT CARGO COMPARTMENT FLOOR PANEL NR 2 AND FLOORBEAM AT STATION 747, RBL 19, CRACKED AT TIE DOWN. MAINTENANCE REMOVED DAMAGED FLOOR PANEL AND DAMAGED SECTION OF FLOORBEAM. FABRICATED REPLACEMENT FLOOR PASDR F3LA00005Skin · corrodedDEN - DURING C-5 CHECK INSPECTION, FOUND CORROSION ON FORWARD LAVATORY SERVICE PANEL BETWEEN SKIN WHERE DUMP FITTING IS MOUNTED. MAINTENANCE FABRICATED REPLACEMENT BRACKETS, HAT SECTION AND STIFFENER AND REPAIRED PER EA 53-737-058 AND BOEING DRAWING 65-45802.SDR F3LA99145Actuator · failedSFO - FLT 653 - DURING APPROACH INTO SFO, FLIGHT CREW REPORTED THE RT MAIN LANDING GEAR WOULD NOT EXTEND. USED ALTERNATE METHOD TO EXTEND GEAR AND GREEN LIGHT ILLUMINATED. FERRIED AIRCRAFT TO DEN. MAINTENANCE REPLACED RT MAIN LANDING GEAR DOWNLOCK ACTUATOR.
Back to Boeing 737-3S1