SDR USAA060542Wedge · delaminatedT/E WEDGE OUTBOARD END DELAMINATED. INSTALLED REPAIR IAW EA 97548, DEFECT SIZE: 11.0" X 6.5".SDR USAA060543Skin · wornBS 879-887 WL 306.5 RBL 3 SKIN HAS FRETTING WEAR. FABRICATED AND INSTALLED REPAIR PARTS IAW SRM 53-60-01 EA 97537, DEFECT SIZE: 9" X .250" X .010".SDR USAA060547Frame · dentedBS 767 S-24L FRAME DENTED. DOUBLER INSTALLED PER TR 53-60-07, DEFECT SIZE: .500 X .500 INCH.SDR USAA060538Angle · corrodedSTA 303-360 LBL 55 CORROSION. REMOVED AND REPLACED Z-ANGLE IAW SRM 53-10-15, DEFECT SIZE: 58 INCHES.SDR SB06033Cable · faultyDURING CRUISE AT FL340, CREW REPORTED ENGINES WERE FLUCTUATING 0.4% N1 FUEL FLOW FROM 2,600 TO 2,630 LBS. ALL GAUGES FLUCTUATING. ENGINES WOULD NOT STAY IN SYNC. PMC ON OR OFF MADE NO DIFFERENCE. AUTOTHROTTLES OFF FLUCTUATED AT 0.6%. DURING A TURN, FLUCTUSDR SB06032Fire Loop · faultyON SHORT FINAL TO RUNWAY 18R IN CLT, FROM CMH, CAPTAIN RECEIVED AN APU FIRE WARNING LIGHT AND BELL. CAPTAIN FIRED THE APU BOTTLE AND DECLARED AN EMERGENCY. THE CRASH AND RESCUE TRUCKS MET THE FLIGHT AND ESCORTED IT TO THE GATE. NO OUTSIDE EVIDENCE OF SMOKE SDR USAA060515Frame · crackedBS 400 BETWEEN S8R AND 9R CRACK. FABRICATED AND INSTALLED REPAIR ANGLES IAW TR 53-10-20D, DEFECT SIZE: .5 INCH.SDR USAA060516Frame · crackedBS 440 BETWEEN STRINGERS 8R AND 9R CRACK. FABRICATED AND INSTALLED REPAIR ANGLES IAW TR 53-10-20D, DEFECT SIZE: .5 INCH.SDR USAA060484Frame · crackedSTA 294, S10R CRACKED. REMOVE AND REPLACE CHORD IAW SRM 51-10-02, DEFECT SIZE: .750 INCH.SDR USAA060477Splice · crackedSTRINGER 4L AT LAP SPLICE, STA 907 CRACKED. PART REPLACED WITH IDENTICAL PART, REPLACED SPLICE IAW SRM 51-40-02, DEFECT SIZE: .25" X .50".SDR USAA060478Splice · crackedTHE 4R AT LAP SPLICE , STA 907 CRACKED. DEFECTIVE PART, REPLACED WITH IDENTICAL PART, INSTALLED NEW SPLICE IAW SRM 51-40-02, DEFECT SIZE: .250 INCH.SDR USAA060479Stringer Clip · crackedSTA 294, S11L CRACKED. MFG NEW TIE CLIP AND INSTALLED IAW DWG 65-45808, DEFECT SIZE: 1 INCH.SDR USAA060480Intercostal · crackedCRACK IN RADIUS OF INTERCOSTAL FWD LEFT SIDE AT STA 294.5 STR 11L. FABRICATED NEW INTERCOSTAL AND INSTALLED IAW DWG 65-1768, DEFECT SIZE: .025 INCH.SDR USAA060481Attach Angle · crackedSTA 360 STR 8L CRACKED. REMOVED ANGLE, FABRICATED AND INSTALLED NEW PART IAW DWG 90-7813, DEFECT SIZE: 1 INCH.SDR USAA060483Frame · crackedSTA 294 S11R CRACKED. REMOVED DAMAGED PART, INSTALLED REPAIR PART IAW SRM 51-10-02, DEFECT SIZE: .500.SDR USAA060482Sill · corrodedSILL WEB STA 794.3 TO 847 CORROSION. REPLACED WITH IDENTICAL PART IAW SRM 51-10-02, DEFECT SIZE: 12" X 2".SDR USAA060471Splice · crackedAFT CABIN STA 908 STR 4L CRACKED. FAB'D PARTS ON TR 567655 PER SRM 51-40-05, 51-40-02, DEFECT SIZE: 1 INCH.SDR SB06027Warmer · dirtyEN ROUTE FROM PIT TO TPA, 90 NAUTICAL MILES NORTH OF CLT, ONE OF THE FLIGHT ATTENDANTS NOTICED A BURNING SMELL IN THE AFT GALLEY. A SECOND FLIGHT ATTENDANT CONFIRMED THE SMELL WAS GETTING WORSE. GALLEY POWER WAS TURNED OFF AND SMELL SUBSIDED. CREW ELECTED TSDR SB06026Light · inoperativeMAINTENANCE REPORTED THE SEAT MOUNTED EMERGENCY EXIT LIGHT AT SEAT ROW 11 INOPERATIVE. MAINTENANCE INSTALLED A SERVICEABLE LIGHT ASSEMBLY. OPERATIONAL CHECK GOOD.SDR USAA060452Angle · corrodedSTA 961 TO 997.5 AFT ENTRY DOOR CORRODED. DEFECTIVE PART REPLACED WITH IDENTICAL PART, REPLACED Z-ANGLE IAW 51-10-2.SDR USAA060451Skin · wornBS 879 TO BS 887 WL 306.5 RBL 3 UNDER DORSAL FIN FAIRING HAS WEAR. FABRICATED AND INSTALLED REPAIR PARTS IAW SRM 53-60-01, DEFECT SIZE: 9 X .250 X .010 INCH DEEP.SDR USAA060450Clip · crackedSTA 727C S4L CRACK. REMOVED AND REPLACED WITH NEW PART IAW SRM 51-10-02, DEFECT SIZE: 1.0 INCH.SDR USAA060447Skin · crackedSTATION 727D, STRINGER 23L CRACKED. FABRICATED REPAIR DOUBLER IAW SRM 53-00-01 FIG 201 DETAIL X1, DEFECT SIZE: 1 INCH.SDR SB06024Csd · overtempFLIGHT DEPARTED MIA, EN ROUTE TO CLT, WITH THE NR 2 ENGINE CSD/GENERATOR ON MEL 24-1. DURING CRUISE, THE NR 1 ENGINE CSD HIGH OIL TEMPERATURE LIGHT ILLUMINATED AS -IN- TEMPERATURE WAS AT MAXIMUM. CREW DISCONNECTED CSD AND DIVERTED TO NEAREST AIRPORT AT MCO. SDR USAA060406Stringer · cracked727E STRINGER 24L CRACKED. INSTALLED DOUBLER/ TRIPLER PER SRM 53-60-03, 53-00-01 REPAIR 31, DEFECT SIZE: 1.12 INCH.SDR USAA060408Skin · damagedFWD CARGO DOOR DAMAGED. REMOVED DAMAGED, INSTALLED DOUBLER IAW SRM 52-30-01, DEFECT SIZE: 5.5 INCH.SDR USAA060387Stringer · damagedREMOVED DAMAGED SECTION, INSTALLED NEW STRINGER SECTION AND SPLICE PARTS IAW SRM 53-00-03.SDR USAA060379Rib · crackedFOUND CRACK WBL 135.5 LOWER AFT LEG OF RIB. FABRICATED AND INSTALLED NEW T-SECTION IAW EA 97417, DEFECT SIZE: 1.5 INCH.SDR USAA060381Stringer · dentedFOUND DENT STA 550 S3R. REMOVED DAMAGED SECTION, SPLICED IN NEW STRINGER IAW SRM 53-00-03, DEFECT SIZE: 1.00 INCH.SDR USAA060378Rib · crackedFOUND CRACKED LOWER AFT LEG OF WBL 135.5 RIB. REMOVED DAMAGE, INSTALLED SHIMS AND REPAIR PARTS IAW EA 97418, DEFECT SIZE: 1.25 INCH.SDR USAA060355Skin · crackedRIGHT STABILIZER, LOWER SKIN AT REAR SPAR, BETWEEN STATIONS 120.30 AND 129 CRACKED. CUT OUT DAMAGED AREA, FABRICATED AND INSTALLED DOUBLER IAW SRM 55-10-01 REPAIR 4, DEFECT SIZE: 3 INCH.SDR USAA060360Skin · crackedCONDITIONED AIR CONNECTION CRACKED. REMOVED DAMAGE, FABRICATED AND INSTALLED REPAIR PARTS IAW SRM 53-30-05A, DEFECT SIZE: 1 INCH.SDR USAA060361Frame · crackedJUST AFT OF STA 291 STUB FRAME CRACKED. REMOVED DAMAGE, INSTALLED WEB REPAIR IAW SRM 51-70-13, DEFECT SIZE: .375 INCH.SDR USAA060362Skin · dentedFUSELAGE STA 420 AND BETWEEN S-21L AND 22-L DENTED. MAJOR REPAIR IAW SRM 53-00-01, DEFECT SIZE: 1 INCH.SDR USAA060363Skin · crackedSLAT ST 3.25 CRACKED. MAJOR REPAIR IAW SRM 57-41-02. DEFECT SIZE: .5 INCH.SDR USAA060364Fitting · crackedOUTBOARD MID SPAR SUPPORT FITTING CRACKED. CRACK WAS CUT OUT, REPAIR PARTS INSTALLED PER TR 57-41-02, DEFECT SIZE: .25 INCH.SDR USAA060354Skin · crackedBS 727E AND 11, JUST BELOW S-23R CRACKED. CUT OUT DAMAGE, FABRICATED AND INSTALLED DOUBLER IAW SRM 53-00-01 REPAIR 31, DEFECT SIZE: 3.5 INCHES.SDR USAA060349Frame · dentedSTA 807, S25L DENTED. REMOVED DAMAGE, INSTALLED DOUBLER REPAIR IAW TR 53-60-07.SDR USAA060348Frame · crackedBS 440 FRAME BELOW STR 8 CRACKED. REMOVED DAMAGE, FABRICATED AND INSTALLED REPAIR PARTS IAW TR 53-10-20, DEFECT SIZE: .50 INCH.SDR USAA060347Angle · wornRT SKATE ANGLE AT VERTICAL STAB INTERSPAR BOX HAS WEAR. REMOVED DAMAGE, FABRICATED AND INSTALLED REPAIR PARTS IAW TR 53-20-05A, DEFECT SIZE: 1 X 3 INCH.SDR USAA060346Angle · wornLT SKATE ANGLE AT VERTICAL STAB INTERSPAR BOX HAS WEAR. REMOVED DAMAGE, FABRICATED AND INSTALLED REPAIR PARTS IAW TR 53-20-02A, DEFECT SIZE: 3 X 1 INCH.SDR USAA060333Skin · crackedCONDITIONED AIR CONNECTION CRACKED. INSTALLED REPAIR DOUBLER AROUND GROUND AIR CONDITIONING ACCESS DOOR CUTOUT IAW TR 53-30-10, DEFECT SIZE: 1 INCH.SDR USAA060323Angle · crackedFOUND TIE ANGLE CRACKED STA 601 S15L. FABRICATED AND INSTALLED NEW TIE ANGLE IAW BOEING DWG 69-77148, DEFECT SIZE: .500".SDR USAA060312Skin · dentedFOUND DENT IN SKIN BS 847 AND S24L. CUT OUT DAMAGED AREA, FABRICATED AND INSTALLED DOUBLER IAW SRM 53-00-01 FIG 201, DEFECT SIZE: 2" BY 2".SDR USAA060311Skin · crackedFOUND CRACK IN FUSELAGE STA 796.3 AND S-24R. INSTALLED DOUBLER IAW EA 58985-1B, DEFECT SIZE: .25".SDR USAA060327Crease Beam · corrodedFOUND WEB RT CREASE BEAM WEB AT STA 578 TO STA 601. REMOVED 10 EA RIVETS, REMOVED SURF CORROSION AND REINSTALLED RIVETS IAW SRM 53-60-13, DEFECT SIZE.SDR USAA060326Stiffener · crackedFOUND CRACK IN VERTICAL STIFFENER STA 92.7 APPROX 24" AFT OF REAR SPAR. FABRICATED NEW STIFFENER AND INSTALLED IAW SRM 51-10-02, DEFECT SIZE: .500".SDR USAA060315Skin · dentedTOP CENTER OF NR 7 SPOILER, 5" DOWN FROM TOP EDGE. INSTALLED DOUBLER IAW TR 27-60-01, DEFECT SIZE: 1".SDR USAA060324Skin · crackedFOUND SKIN RADIUS OF UPPER HINGE CUT OUT OF FWD SERVICE DOOR. INSTALLED DOUBLER IAW TR 52-10-13, DEFECT SIZE: .375".SDR USAA060316Skin · lightning strikeFOUND LIGHTNING BS 440-460, S1-TO S2L. REMOVED RIVETS, REMOVED DAMAGE AT TWO PLACES IAW SRM 53-00-01, DEFECT SIZE: .093.
Back to Boeing 737-4B7