SDR ASAA9940120Battery Charger · inoperativeJNU - DURING MAINTENANCE CHECK, THE EMERGENCY EXIT FLOOR TRACK LIGHTS WERE FOUND TO BE INOPERATIVE AT ROWS 13 AND 14. REPLACED BATTERY CHARGER AND LIGHTS OPERATED NORMALLY. (X)May 28, 1999 · N782AS · Boeing 7374Q8 · Emergency LightingSDR ASAA9940117Mechanism · lack of lubePDX - PRIOR TO FLIGHT 409, CREW REPORTED THAT THE L1 DOOR WAS DIFFICULT TO CLOSE. INSPECTED, CLEANED, AND LUBRICATED DOOR. DOOR OPERATED NORMALLY. (M)May 27, 1999 · N754AS · Boeing 7374Q8 · Passenger/Crew DoorsSDR ASAA9940116Mechanism · out of adjustSEA - PRIOR TO DEPARTURE OF FLIGHT 63, CREW REPORTED L-1 DOOR DIFFICULT TO CLOSE. ADUSTED DOOR MECHANISM AND DOOR OPERATED NORMALLY. (M)May 22, 1999 · N763AS · Boeing 7374Q8 · Passenger/Crew DoorsSDR ASAA9940108Guide Arm · failedPDX - DURING A-CHECK, THE R-1 DOOR HOLD OPEN LEVER WOULD NOT FUNCTION PROPERLY. REPLACED UPPER GUIDE ARM AND DOOR OPERATED NORMALLY. (M)May 13, 1999 · N771AS · Boeing 7374Q8 · Service DoorsSDR ASAA9940105Wire · disconnectedONT - FLT 354 - THE EMERGENCY EXIT FLOOR TRACK LIGHTS IN ROW 16 AREA WERE FOUND INOPERATIVE. RECONNECTED LOOSE WIRING AT ROW 16 AND LIGHTS OPERATED NORMALLY. (M)May 7, 1999 · N754AS · Boeing 7374Q8 · Light System WiringSDR ASAA9940103Wire · disconnectedSNA - FLT 389 - BOTH FORWARD RED EMERGENCY EXI TFLOOR TRACK LIGHTS WERE FOUND INOPERATIVE. RECONNECTED WIRING AND LIGHTS OPERATED NORMALLY. (M)May 3, 1999 · N756AS · Boeing 7374Q8 · Light System WiringSDR ASAA9940101Wire · disconnectedOAK - FLT 389 - THE EMERGENCY EXIT FLOOR TRACK LIGHTS AT ROW 19 WERE FOUND INOPERATIVE. RECONNECTED BROKEN WIRING AT ROW 19 AND LIGHTS OPERATED NORMALLY. (M)Apr 30, 1999 · N754AS · Boeing 7374Q8 · Light System WiringSDR ASAA9940100Snubber · failedSEA - FLT 399 - L-1 DOOR DIFFICULT TO CLOSE. REPLACED L-1 DOOR SNUBBER ASSEMBLY AND DOOR OPERATED NORMALLY. (M)Apr 25, 1999 · N779AS · Boeing 7374Q8 · Passenger/Crew DoorsSDR ASAA9940094Lens · missingSEA - FLT 215 - PRIOR TO DEPARTURE, THE PLASTIC 'EXIT SALIDA' LENS WAS FOUND MISSING FROM THE EXIT SIGN ADJACENT TO THE L-2 DOOR. REPLACED 'EXIT' SIGN LENS ASSEMBLY. (M)Apr 22, 1999 · N776AS · Boeing 7374Q8 · Emergency LightingSDR ASAA9940093Lens · missingPDX - DURING MAINTENANCE CHECK, THE EXIT SIGN LENS AT THE R-2 DOOR WAS FOUND MISSING. REPLACED 'EXIT' SIGN LENS ASSEMBLY. (M)Apr 21, 1999 · N782AS · Boeing 7374Q8 · Emergency LightingSDR ASAA9940092Mechanism · lack of lubeANC - FLT 88 - L-2 DOOR DIFFICULT TO OPEN AND CLOSE, MAKES METAL GRINDING NOISE. LUBED DOOR ARMS AND ROLLER TRACKS, AND DOOR OPERATED NORMALLY. (M)Apr 17, 1999 · N785AS · Boeing 7374Q8 · Service DoorsSDR ASAA9940091Guide Arm · out of adjustPDX - FLT 343 - L-1 DOOR DIFFICULT TO CLOSE. ADJUSTED GUIDE ARM AND DOOR OPERATED NORMALLY. (M)Apr 16, 1999 · N776AS · Boeing 7374Q8 · Passenger/Crew DoorsSDR ASAA9940089Light · brokenSEA - DURING MAINTENANCE CHECK, THE R-2 DOOR EMERGENCY EXIT LIGHT ASSEMBLY WAS FOUND BROKEN. REPLACED R-2 DOOR EXIT IDENTIFIER LIGHT ASSEMBLY AND LIGHT OPERATED NORMALLY. (M)Apr 12, 1999 · N763AS · Boeing 7374Q8 · Emergency LightingSDR ASAA9940088Wire · disconnectedPDX - DURING MAINTENANCE CHECK, THE AFT 6 EMERGENCY EXIT FLOOR TRACK LIGHTS WERE FOUND INOPERATIVE. RECONNECTED LIGHTS/WIRING AND LIGHTS OPERATED NORMALLY. (M)Apr 11, 1999 · N778AS · Boeing 7374Q8 · Light System WiringSDR ASAA9940087Wire · disconnectedPDX - DURING MAINTENANCE CHECK, THE FORWARD 3 AND AFT 3 EMERGENCY EXIT FLOOR TRACK LIGHTS WERE FOUND INOPERATIVE. RECONNECTED LIGHTS/WIRING AND LIGHTS OPERATED NORMALLY. (M)Apr 9, 1999 · N756AS · Boeing 7374Q8 · Light System WiringSDR ASAA9940079Wire · disconnectedPDX - DURING MAINTENANCE CHECK, THREE EMERGENCY EXIT FLOOR TRACK LIGHTS AT THE AFT OVERWING EXIT WERE FOUND TO BE INOPERATIVE. RECONNECTED LIGHTS/WIRING AND LIGHTS OPERATED NORMALLY. (M)Apr 1, 1999 · N779AS · Boeing 7374Q8 · Light System WiringSDR ASAA9940078Beam · corrodedPHX - DURING SI CHECK, FOUND THE R1 DOOR TRANSVERSE BEAM CORRODED AT STATION 280-344. (M)Mar 31, 1999 · N763AS · Boeing 7374Q8 · Fuselage Miscellaneous StructureSDR ASAA9940077Skin · dentedPHX - DURING SI CHECK, FOUND THE FORWARD CARGO DOOR CUTOUT, FORWARD SIDE DENTED BETWEEN S23R AND S24R. REPAIRED PER EA 5330-01369. (M)Mar 31, 1999 · N763AS · Boeing 7374Q8 · Fuselage Main, Plate/SkinSDR ASAA9940076Floorbeam · corrodedPHX - DURING SI CHECK, FOUND THE FLOORBEAM AT STATION 294.5, BL 0 - RBL 5 UPPER CAP CORRODED. REPAIRED PER EA 53-10-08. (M)Mar 31, 1999 · N763AS · Boeing 7374Q8 · Fuselage Main, Floor BeamSDR ASAA9940075Floorbeam · corrodedPHX - DURING SI CHECK, FOUND THE FLOORBEAM UPPER HORIZONTAL CAP CORRODED AT STAITON 967, LBL 18. REPAIRED PER SRM 53-00-51. (M)Mar 31, 1999 · N763AS · Boeing 7374Q8 · Fuselage Main, Floor BeamSDR ASAA9940074Floorbeam · corrodedPHX - DURING SI CHECK, FOUND THE FLOORBEAM UPPER HORIZONTAL CAP, TO SURFACE, CORRODED AT STATION 312 LBL 2 - RLB 7. REPAIRED PER SRM 53-10-51 AND DRAWING 65C33941. (M)Mar 31, 1999 · N763AS · Boeing 7374Q8 · Fuselage Main, Floor BeamSDR ASAA9940073Skin · damagedPHX - DURING SI CHECK, FOUND THE RIGHT FUSELAGE SKIN AT STATION 490-500, STRINGER 22R-24R NICKED. REPAIRED PER SRM 53-00-01. (M)Mar 31, 1999 · N763AS · Boeing 7374Q8 · Fuselage Main, Plate/SkinSDR ASAA9940072Frame · crackedPHX - DURING SI CHECK, FOUND THE R1 DOOR CUTOUT FORWARD FRAME AT STATION 296 WL 209 CRACKED. REPAIRED PER EA 5310-01664. (M)Mar 31, 1999 · N763AS · Boeing 7374Q8 · Fuselage Miscellaneous StructureSDR ASAA9940086Web · corrodedPHX - DURING SI CHECK, FOUND THE SHEAR WEB UNDER LEFT TRANSVERSE BEAM AT L-2 DOOR THRESHOLD CORRODED AT STATION 991, LBL 37. REPAIRED PER SRM 51-40-02 AND SRM 53-60-51. (M)Mar 30, 1999 · N763AS · Boeing 7374Q8 · Fuselage Miscellaneous StructureSDR ASAA9940085Beam · corrodedPHX - DURING SI CHECK, FOUND THE L-2 DOOR LOWER SEAL TRANSVERSE BEAM CORRODED FROM STATION 949 TO 997. REPAIRED PER SRM 51-40-02. (M)Mar 30, 1999 · N763AS · Boeing 7374Q8 · Fuselage Miscellaneous StructureSDR ASAA9940082Floorbeam · corrodedPHX - DURING SI CHECK, FOUND THE UPPER HORIZONTAL CAP OF THE FLOORBEAM AT STATION 947.5 CORRODED FROM RBL 13 TO LBL 13. REPAIRED PER EA 5310-01665. (M)Mar 30, 1999 · N763AS · Boeing 7374Q8 · Fuselage Main, Floor BeamSDR ASAA9940081Floorbeam · corrodedPHX - DURING SI CHECK, FOUND THE UPPER HORIZONTAL CAP OF THE FLOORBEAM AT STATION 360 CORRODED FROM RBL 14 TO RBL 28. REPAIRED PER EA 5310-01666. (M)Mar 30, 1999 · N763AS · Boeing 7374Q8 · Fuselage Main, Floor BeamSDR ASAA9940080Floorbeam · corrodedPHX - DURING SI CHECK, FOUND THE UPPER HORIZONTAL CAP OF THE FLOORBEAM AT STATION 986.5 CORRODED IN NUMEROUS AREAS FROM LBL 45 TO RBL 31. REPAIRED PER EA 5310-01667. (M)Mar 30, 1999 · N763AS · Boeing 7374Q8 · Fuselage Main, Floor BeamSDR ASAA9940069Wire · disconnectedSEA - DURING MAINTENANCE CHECK, THE EMERGENCY EXIT FLOOR TRACK LIGHTS WERE FOUND TO BE INOPERATIVE AT ROWS 14 THROUGH 17. RECONNECTED WIRING AND LIGHTS AT ROWS 16 AND 17, AND RELAMPED. LIGHTS OPERATED NORMALLY. (M)Mar 27, 1999 · N754AS · Boeing 7374Q8 · Light System WiringSDR ASAA9940068Latch · out of adjustPDX - PRIOR TO FLT 348, THE ATTENDANT REPORTED THAT THE L1 DOOR WAS HARD TO CLOSE. LUBRICATED HINGE POINTS AND ADJUSTED THE FORWARD UPPER LATCH CAM FITTING. DOOR OPERATED NORMALLY. (M)Mar 26, 1999 · N782AS · Boeing 7374Q8 · Passenger/Crew DoorsSDR ASAA9940066Wire · disconnectedPDX - PRIOR TO FLIGHT 343 - THE EMERGENCY EXIT FLOOR TRACK LIGHTS WERE FOUND TO BE INOPERTIVE AT ROW 15. RECONNECTED WIRING AND LIGHTS OPERATED NORMALLY. (M)Mar 16, 1999 · N754AS · Boeing 7374Q8 · Light System WiringSDR ASAA9940065Hinge Cover · bentPDX - FLT 604 - PRIOR TO 604, THE L2 DOOR UPPER FORWARD HINGE COVER WAS FOUND TO BE BENT, CAUSING INTERFERENCE WITH DOOR OPENING. REMOVED HINGE COVER AND RELEASED PER CDL 52-40-6. DOOR OPERATED NORMALLY. MAINTENANCE SUBSEQUENTLY INSTALLED A NEW UPPER FORWARMar 15, 1999 · N778AS · Boeing 7374Q8 · Service DoorsSDR ASAA9940064Wire · disconnectedPDX - DURING MAINTENANCE CHECK, THE FORWARD TWO TRACK LIGHTS WERE FOUND INOPERATIVE. RECONNECTED WIRING AND LIGHTS OPERATED NORMALLY. (M)Mar 11, 1999 · N776AS · Boeing 7374Q8 · Light System WiringSDR ASAA9940063Light · brokenPDX - DURING MAINTENANCE CHECK, THE FORWARD THREE EMERGENCY TRACK LIGHTS WERE FOUND TO BE INOPERATIVE. REPLACED BROKEN LIGHT ASSEMBLY AND LIGHTS OPERATED NORMALLY. (M)Mar 3, 1999 · N776AS · Boeing 7374Q8 · Emergency LightingSDR ASAA9940060Wire · failedSEA - DURING MAINTENANCE CHECK, FOUND EMERGENCY EXIT TRACK LIGHTS INOPERATIVE AT ROW 14. REPAIRED WIRING AND RELAMPED SEVERAL RECEPTICLE, LIGHTS OPERATED NORMALLY. (M)Mar 2, 1999 · N773AS · Boeing 7374Q8 · Light System WiringSDR ASAA9940062Skin · damagedSEA - DURING SCHEDULED C-CHECK, FOUND DAMAGE TO THE NR 1 SLAT CENTER AUXILIARY TRACK CUTOUT SKIN AT SS 340.70. REPAIRED PER EA 5740-01159. (M)Mar 1, 1999 · N778AS · Boeing 7374Q8 · Wing, Plate/SkinSDR ASAA9940061Skin · separatedSEA - DURING SCHEDULED C-CHECK, THE RIGHT SIDE OF THE RUDDER SKIN FIRST PLY WAS FOUND TO BE SEPARATED. REPAIRED PER EA 5540-01030 AND BOEING TELEX ASA-SEA-99-0114RR. (M)Mar 1, 1999 · N778AS · Boeing 7374Q8 · Rudder, Plate/SkinSDR ASAA9940058Wire · failedSEA - DURING MAINTENANCE CHECK, THE EMERGENCY EXIT TRACK LIGHTING WAS FOUND TO BE INOPERATIVE AT ROWS 6-9. REPLACED WIRING HARNESS AT ROW 6, LIGHTS OPERATED NORMALLY. (M)Mar 1, 1999 · N760AS · Boeing 7374Q8 · Light System WiringSDR ASAA9940057Lever · bentPDX - DURING MAINTENANCE CHECK, THE R1 DOOR WOULD NOT STAY OPEN WITH THE LEVER ASSEMBLY. REPLACED HOLD OPEN LEVER ASSEMBLY AND DOOR REMAINS OPEN NORMALLY. (M)Feb 27, 1999 · N762AS · Boeing 7374Q8 · Service DoorsSDR ASAA9940056Battery · dischargedSEA - DURING MAINTENANCE CHECK, MULTIPLE EMERGENCY EXIT TRACK LIGHTS WERE FOUND TO BE INOPERATIVE IN THE FORWARD CABIN. REPLACED BATTERY AND LIGHTS OPERATED NORMALLY. (M)Feb 26, 1999 · N755AS · Boeing 7374Q8 · Emergency LightingSDR ASAA9940055Wire · disconnectedANC - DURING MAINTENANCE CHECK, THE EMERGENCY EXIT TRACK LIGHTS WERE FOUND TO BE INOPERATIVE AT ROWS 14-18. RECONNECTED LIGHTS AND WIRING AT ROW 18 AND LIGHTS OPERATED NORMALLY. (M)Feb 26, 1999 · N754AS · Boeing 7374Q8 · Light System WiringSDR ASAA9940053Slide · failedSAN - PRIOR TO FLIGHT 557, THE R2 DOOR SLIDE WAS NOT DISARMED WHEN DOOR WAS OPENED AND SLIDE DID NOT DEPLOY. FERRIED AIRCRAFT TO SEA FOR REPAIR DUE TO SLIDE NOT BEING ABLE TO BE RESTOWED. SEA MAINTENANCE REPLACED THE R1 DOOR SLIDE. THE SLIDE WAS ROUTED TO TFeb 17, 1999 · N762AS · Boeing 7374Q8 · Emergency EquipmentSDR ASAA9940051Wire · disconnectedPDX - DURING MAINTENANCE CHECK, THE AFT 2 EMERGENCY EXIT FLOOR TRACK LIGHTS WERE FOUND TO BE INOPERATIVE. RECONNECTED WIRING AND LIGHTS, LIGHTS OPERATED NORMALLY. (M)Feb 17, 1999 · N771AS · Boeing 7374Q8 · Light System WiringSDR ASAA9940049Floorbeam · corrodedPHX - DURING SCHEDULED SI, THE AFT CABIN UPPER SURFACE FLOORBEAM AT STATION 947 LBL 4 AND RBL 5 WAS FOUND TO BE CORRODED. REPAIRED PER EA 5310-01642. (M)Feb 12, 1999 · N755AS · Boeing 7374Q8 · Fuselage Main, Floor BeamSDR ASAA9940048Floorbeam · corrodedPHX - DURING SCHEDULED SI, THE AFT CABIN UPPER SURFACE FLOORBEAM AT STATION 967 RBL 18 WAS FOUND TO BE CORRODED. INSTALLED REPAIR SECTION, SPLICE AND STRAP PER SRM 53-00-51. (M)Feb 12, 1999 · N755AS · Boeing 7374Q8 · Fuselage Main, Floor BeamSDR ASAA9940047Intercostal · crackedPHX - DURING SCHEDULED SI, THE INTERCOSTAL AT BS 294.5-312 STRINGER 4L WAS FOUND TO BE CRACKED. REPLACED INTERCOSTAL PER SRM 51-40-2. (M)Feb 12, 1999 · N755AS · Boeing 7374Q8 · Fuselage Miscellaneous StructureSDR ASAA9940046Support · corrodedPHX - DURING SCHEDULED SI, THE AFT CARGO COMPARTMENT FLOOR SUPPORT FROM STATION 867-947 STRINGER 25R WAS FOUND TO BE CORRODED. REPLACED FLOOR SUPPORT PER SRM 51-40-02 AND 53-60-53. (M)Feb 12, 1999 · N755AS · Boeing 7374Q8 · Fuselage Miscellaneous StructureSDR ASAA9940045Support · corrodedPHX - DURING SCHEDULED SI, THE AFT CABIN UPPER SURFACE FLOOR SUPPORT AT STATION 947 BETWEEN RBL 24 AND RBL 50 WAS FOUND TO BE CORRODED. REPLACED FLOOR SUPPORT PER SRM 51-40-02. (M)Feb 12, 1999 · N755AS · Boeing 7374Q8 · Fuselage Miscellaneous StructureSDR ASAA9940044Support · corrodedPHX - DURING SCHEDULED SI, THE AFT CABIN UPPER SURFACE FLOOR SUPPORT AT STATION 947-967 RBL 16 WAS FOUND TO BE CORRODED. REPLACED FLOOR SUPPORT PER SRM 51-40-00. (M)Feb 12, 1999 · N755AS · Boeing 7374Q8 · Fuselage Miscellaneous StructureSDR ASAA9940043Support · corrodedPHX - DURING SCHEDULED SI, THE AFT CABIN UPPER SURFACE FLOOR SUPPORT BETWEEN STATION 947-967 LBL 16 WAS FOUND TO BE CORRODED. REPLACED FLOOR SUPPORT PER SRM 51-40-01. (M)Feb 12, 1999 · N755AS · Boeing 7374Q8 · Fuselage Miscellaneous Structure
Back to Boeing 737-4Q8