SDR 2007UALA03624Fire Bottle · dischargedDURING PANEL REPLACEMENT FOR POP SPILL FOUND 1ST BOTTLE FOR CARGO FIRE BOTTLE DISCHARGE LIGHT ON. OPENED PANEL IN FWD PIT AND FOUND BOTTLE DISCHARGED. REPLACED BOTH CARGO FIRE BOTTLES, DIVERTER VALVE, METERING VALVE, SQUIBS AND FILTERS.SDR 2007UALA03595Girt Bar · out of positionGIRT BAR AT 1L HANGING OUT.SDR 2007UALA03594Skin · crackedRIGHT AFT SERVICE DOOR CUTOUT HAS CRACK AT LOWER FWD CORNER.SDR 2007UALA03593Elevator · faultyLEFT HAND ELEVATOR FAILED FREE PLAY CHECK AND WAS FOUND WITH NO HINGE PUTTY.SDR 2007UALA03545Bleed Air Sys · malfunctionedDURING CLIMB ACFT LOST RT BLEED SUPPLY. CABIN PRESSURE REACHED 10,000 FT, RAPID DESCENT TO FL230 AND SITUATION STABILIZED. MASKS DID NOT DEPLOY.SDR 2007UALA03521Warning System · malfunctionedNLG RED LIGHT CONSTANTLY ON WITH GEAR HANDLE UP OR OFF.SDR 2007UALA03493Lamp · burned outOUTSIDE LEFT OVERWING EMERGENCY LIGHT BURNED OUT. RELAMPED ASSY, OPS CHECK NORMAL.SDR 2007UALA03548Warning System · activatedNR 1 LEADING EDGE FLAP OVERHEAD INDICATED GREEN WITH AMBER LEADING EDGE FLAPS TRANSITION, FLAP HANDLE UP. RESTRICTION 230KIAS, FL200 AND .65MACH.SDR 2007UALA03418Light · detachedAFT GALLEY ESCAPE PATH LIGHTS TOTALLY DETACHED FROM FLOOR. REPAIRED AND SECURED AFT GALLEY EEL LIGHTS. OPS CHECK GOOD, NO REPEATS SINCE ORIGINAL.SDR 2007UALA03417Feeder Cable · faultyEEL LIGHTS ARE INOP FROM ROW 15 TO THE BACK OF THE PLANE. EEL CABLE FAULTY. REPLACED EEL CABLE FROM FEED IN. NO REPEATS SINCE ORIGINAL.SDR 2007UALA03348Door Frame · crackedFWD CARGO DOORWAY CUTOUT, AFT FRAME IS CRACKED AT LWR STOP FITTING. MAJOR REPAIR ACCOMPLISHED: REMOVED & INSTALLED NEW FRAME.SDR 2007UALA03347Door Frame · crackedAFT CARGO DOOR CUTOUT, FWD FRAME IS CRACKED AT LWR STOP FITTING. MAJOR REPAIR ACCOMPLISHED: REMOVED & REPLACED FWD FRAME BS 794.SDR 2007UALA03309Frame · damagedCABIN FLOOR CREASE BEAM REQUIRES TO BE CUT FOR ACCESS TO REPAIR FRAME BS 446 - 466 STR 17R. MAJOR REPAIR ACCOMPLISHED: FABRICATED & INSTALLED CREASE BEAM REPAIR.SDR 2007UALA03308Crease Beam · damagedAFT CARGO CREASE BEAM AT WL 208 IS DAMAGED. MAJOR REPAIR ACCOMPLISHED: INSTALLED TYPICAL EXTRUDED SECTION REPAIR. CREASE BEAM CUT AT STA 776. REPAIRED FROM STA 770-782 STR 17R.SDR 2007UALA03306Disc · rupturedLOW BOTTLE PRESSURE. FOUND RUPTURED PRESSURE DISC. REPLACED DISC, RECHECKED FOR LEAKS, NO LEAKS FOUND. RESERVICED BOTTLE.SDR 2007UALA03205Coffeemaker · odorBURNING WIRE ODOR REPORTED IN CABIN. CLEANED BURNED COFFEE OFF FWD GALLEY COFFEE MAKER HOT PLATE. NO WIRES FOUND BURNED.SDR 2007UALA03170Module · faultyENG APU FIRE MOD NR 2 ENG DISCHARGE FAILS TEST. REPLACED ENGINE APU FIRE MODULE, NO FAULTS NOTED DURING TEST.SDR 2007UALA03124Repair · missingNR 4 SLAT HAS EXPOSED HONEYCOMB FROM A MISSING REPAIR, 5 INCHES BY 5.5 INCHES AT INBOARD TRAILING EDGE.SDR 2007UALA03126Inverter · inoperativeTHREE SEGMENTS OF EEL LIGHTS INOP AFT CABIN AFT GALLEY. REPLACED INVERTER. OPS CHECKS GOOD.SDR 2007UALA03125Power Strip · contaminatedFLOOR MOUNTED EEL LIGHTS INOP FROM ROW 11 TO AFT GALLEY. REPLACED WET POWER STRIP. REPLACED WET POWER STRIP.SDR 2007UALA03075Lamp · burned outFOUND EEL LAMP DIM ROW 15. REPLACED LAMP. CKS NORMAL.SDR 2007UALA03074Lamp · burned outFOUND EMERGENCY AISLE LIGHT INOP ROW 15D. RELAMPED. OPS CK NORMAL.SDR 2007UALA03073Lamp · burned outFOUND EEL LAMP INOP ROW 10. REPLACED LAMP. CHKS OKAY.SDR 2007UALA03054Girt Bar · faultyCREW REPORT, DOOR 2L WILL NOT ARM PROPERLY. HOOK AND LOOP HOLDING GIRT BAR ASSY CAME LOOSE, ALLOWING IT TO MOVE OUT OF POSITION. REMOVED SLIDE AND REPOSITIONED GIRT BAR AND HOOK AND LOOP, REINSTALLED SLIDE. ARMS NORMALLY.SDR 2007UALA03028Fire Detector · faultyNORMAL FIRE TEST OF NR 2 ENGINE DOES NOT TEST. FOUND HIGH TEMP TERMINALS AT CORE DETECTOR M1122 IMPROPERLY CRIMPED. REPAIRED WIRING AND CRI MPED ON NEW TERMINALS. RAN ENGINE FOR TEN MINUTES AND PERFORMED FIRE TEST NUMEROUS TIMES, NO FAULT NOTED.SDR CA070807002Smoke Detector · malfunctioned(CAN) ENROUTE, IT WAS LESS THEN AN HOUR INTO THE FLIGHT WHEN AN ORANGE DETECT LIGHT FOR THE FORWARD CARGO SMOKE DETECTION SYSTEM CAME ON. THE EXTINGUISHER SYSTEM WAS ACTIVATED AND THE FLIGHT DIVERTED TO CLOSEST AIRPORT AND LANDED SAFELY. AN INSPECTION OF THE SDR 2007UALA02995Wire · shortedCAPTAIN'S FIRE LIGHT INOP. FOUND ELECTRICAL SHORT WITHIN THE MASTER WARNING CAPT FIRE ASSY. REPLACED THE MASTER WARNING CAPT FIRE ASSY L340.SDR 2007UALA02890Light · inoperativeEEL LIGHTS ON FLOOR IN AFT GALLEY IS INOPERATIVE. DRIED WATER OUT OF EEL TRACK.SDR 2007UALA02883Ground Wire · disconnectedNR 3 LE FLAP FULL EXTEND AND FWD PNL INTRANSIT LIGHTS ON WITH FLAPS RETRACTED. ALL WIRE BUNDLE CLAMPS FROM S173 SENSOR TO SPLICES AT PRESSURE FEED THRU LOCATED 3 FEET OB OF WING ROOT ARE LOOSE. GROUND WIRES AT GD148AC ARE ALSO DISCONNECTED. SECURED WIRING ANSDR 2007UALA02891Light · inoperativeAFT CABIN EEL LIGHTS INOP FROM ROW 8 AFT TO AND INCLUDING EEL STRIP IN FRONT OF AFT GALLEY CART STOWAGE COMPARTMENT. REPLACED CABLE AND 3 EEL LIGHT STRIPS.SDR 2007UALA02827Frame · damagedFRAME DAMAGE AT STA 420, ACROSS STRINGER BAYS 28L-28R, AND 27R-28R. [08-21-07] MAJOR REPAIR: REMOVED DAMAGE. REPAIR ACCOMPLISHED.SDR 2007UALA02824Engine · seizedNR 1 ENGINE N1 SEIZED AND METAL IN TAIL PIPE. N1 SEIZED DUE TO SCATTERED BROKEN STAGE 1 LPT BLADES. FOLLOWING SEIZURE, STAGE 2 NGV'S AND REMAINDER OF BLADES IN STAGE 1 BURNED/MELTED. NO KNOWN CAUSE FOR INITIAL BROKEN 1ST STAGE BLADES.SDR 2007UALA02807Wire · damagedCENTER FQI INOP, NR 2 ENG FUEL FLOW INDICATOR INOP. FOUND CENTER CONDUCTOR WIRE PULLED OUT OF D800 IN COCKPIT. CONNECTOR REPLACED AND CTR TANK DCTU CALIBRATED.SDR 2007UALA02765Door Frame · crackedAFT CARGO PIT DOOR CUTOUT, FWD FRAME WEB CRACKED AT LOWER STOP PAD, LOWER OUTBOARD CORNER. MAJOR REPAIR: REMOVED AND INSTALLED NEW FRAME PER SRM 51-40-02, PG 1-40.SDR 2007UALA02750Inverter · faultyFLOOR EEL LIGHTS INOP FROM SEAT 14C AFT TO GALLEY. REPLACED INVERTER AND CORRECTED WIRING.SDR 2007UALA02740Door Frame · crackedRIGHT AFT GALLEY DOOR CUTOUT HAS CRACK AT FWD LOWER CORNER. MAJOR REPAIR ACCOMPLISHED: REMOVED DAMAGE. ACCOMPLISHED 2EA DOUBLER & 1EA TRIPLER REPAIR.SDR 2007UALA02739Door Frame · crackedFWD CARGO DOOR CUTOUT, AFT FRAME, CRACKED AT INNER RADIUS JUST ABOVE LOWER STOP PAD FITTING. MAJOR REPAIR ACCOMPLISHED: FABRICATED & INSTALLED ANGLE REPAIR.SDR 2007UALA02717Sleeve · wornCABIN DOOR 2R ESCAPE SLIDE PACK GIRT BAR PROTECTIVE SLEEVE IS TORN AND MISSING AT RELEASE CABLE EYELET. [08-17-07] FOUND TO BE WORN. REPLACED SLIDE PACK.SDR 2007UALA02753Structure · dentedCREW REPORTS DENT IN RT HORIZONTAL STABILIZER LEADING EDGE. [08-17-07] MAJOR REPAIR: PER UA EVA-70388 INTERM REPAIR MADE.SDR 2007UALA02680Slide · faultyTHREADING ON DOOR 2L SLIDE IS COMING APART. [08-07-07] STOWED THREADING BACK IN SLIDE FLAP.SDR 2007UALA02679Torque Tube · excess playFWD ENTRY DOOR UPPER LATCHING TORQUE TUBE HAS EXCESSIVE FWD AND AFT PLAY. [08-07-07] INSTALLED 2 SHIMS ON AFT SIDE OF LATCH TORQUE TUBE.SDR 2007UALA02678Slide · out of positionCABIN 1L DOOR ESCAPE SLIDE HAS SHIFTED AFT IN CONTAINER, GIRT IS MISROUTED AROUND AFT GIRT BAR STOW BRACKET. [08-08-07] ADJUSTED SLIDE.SDR 2007UALA02594Oxygen Mask · leakingFIRST OFFICER'S O2 MASK HEAD BAND HAS AIR LEAK. [08-08-07] MASK FOUND WORN. REPLACED OXYGEN MASK.SDR 2007UALA02593Battery · failedAFT OUTBOARD EMERGENCY FLASHLIGHT DOES NOT BLINK. [08-08-07] FAILED BATTERY. REPLACED BATTERY AND FLASHLIGHT.SDR 2007UALA02588Skin · damagedEXTERIOR SKIN DENTED AND GOUGED AT STA 400 UPPER FWD CARGO CUTOUT. MAJOR REPAIR ACCOMPLISHED: REMOVED CRACKS & ACCOMPLISHED A DOUBLER/TRIPLER REPAIR.SDR 2007UALA02587Door Frame · crackedFWD CARGO DOOR CUTOUT AFT FRAME IS CRACKED IN 3 PLACES, 2 CRACKS ON FWD SIDE OF THE FRAME AT OUTBOARD LOWER CORNER AND INBOARD UPPER CORNER OF BOTTOM STOP FITTING AND THE THIRD CRACK IS ON AFT SIDE OF FRAME IN RADIOUS ADJACENT TO INBOARD UPPER CORNER OF BOTTOMSDR 2007UALA02540Apu · unknownAPU POWER PROBLEMS. [08-08-07] REPLACED APU GENERATOR TRANSFORMER T2 AS A PRECAUTION. OPERATIONAL CHECKS NORMAL.SDR 2007UALA02542Indicator · out of alignmentRUDDER TRIM INDICATOR INOPERATIVE. REPLACED RUDDER TRIM INDICATOR. UNIT OFF ALIGNMENT. REPAIRED CONNECTOR PINS AND ALIGNED INDICATOR.SDR 2007UALA02536Skin · gougedUPPER FUSELAGE EXTERNAL SKIN IS GOUGED AT STA 277 STR 3L. MAJOR REPAIR ACCOMPLISHED: REMOVED DAMAGE. INSTALLED DOUBLER/TRIPLER REPAIR.SDR 2007UALA02477Lamp · inoperativeSTOW BIN 2A EMERGENCY LIGHT IS INOPERATIVE. [07-27-07] RELAMPED.
Back to Boeing 737-522