Boeing 737-73V
Service difficulty reports · 1,826
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '73773V' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '73773V' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2022021865875Panel · delaminatedLOWER FUSELAGE PANEL BETWEEN AFT END OF RIGHT AIR CONDITIONING BAY AND WHEEL WELL IS DELAMINATED / REMOVED AND REPLACED FAIRING 193AR PER AMM 53-51-21SDR SWAA2018082724574Pump · faultyAIR TURNBACK, ENGINE NR 2 HYDRAULIC LOW PRESSURE LIGHT. R&R NR 2 ENGINE DRIVEN PUMP IAW AMM.SDR SWAA2018081624270Battery · failedRT AFT CABIN EMERGENCY EXIT LIGHT BATTERY FAILED TEST. R&R BATTERY PER MM.SDR SWAA2022022264231None · crackedSUPPLEMENTAL INFORMATION: AFT SPAR VERTICAL SEAL RETAINER IS CRACKED ABOVE #1 ENGINE AFT FAIRING / REMOVED AND REPLACED PER SRM 51-40-02.SDR SCNA201808132102Stiffener · brokenDURING REPAIR OF UPPER LT WING SKIN, FOUND A STIFFINER AT THE WING LE TO PYLON RIB WS 204 WAS BROKEN. REMOVED THE DAMAGED STIFFENER. NDT INSPECTION PERFORMED. NO CRACKS NOTED. INSTALLED THE NEW STIFFENER. OK FOR SERVICE.SDR SCNA201808130101Skin · damagedLEFT WING UPPER SURFACE L/E. OTBD OF KRAS 206. THE LAST 18 OTBD AFT RIVETS ARE LOOSE AND WORKING. REMOVE 29 FASTNERS. FOUND L/E SKIN DAMAGED IN THE FORM OF OVERSIZED COUNTER SINKS IN THE SKIN. MOST OBRD FASTNER PULLED THROUGH THE SKIN. REMOVED PNEU. DUCT BY THSDR SWAA2018080824119Cover · unsecureR2 DOOR EMERGENCY EXIT LIGHT COVER FELL OFF. R&R LIGHT ASSEMBLY PER AMM.SDR SWAA2018072323684Coffeemaker · faultyDIVERSION, REPORTED BURNT RUBBER SMELL IN AFT GALLEY. R&R NR 2 AFT GALLEY COFFEEMAKER PER AMM.SDR SWAA2018072323683Coffeemaker · faultyDIVERSION< REPORTED BURNT RUBBER SMELL IN AFT GALLEY. R&R NR 1 AFT GALLEY COFFEEMAKER PER AMM.SDR ASMF20180918001Warning System · false activationAIRCRAFT RETURNED OF FLIGHT DUE TO DURING CLIMB MAP FLAG AND TCAS OFF APPEARED ON MFD. MAINTENANCE PERSONNEL PERFORMED FAULT ISOLATION PROCEDURE TO TCAS IAW FIM 34-45 TASK 801, ADIRUS IAW FIM 31-21 TASK 801 AND PA IAW FIM 22-11 TASK 801, NO CONFIRMING FAILURE,SDR SWAA2022021810492Stringer · crackedTHERE IS DAMAGE TO STRINGER 182 WHICK INCLUDES A DENT. DEFORMATION AND A CRACK AT AREA BETWEEN STA 879-881. / CUT AND REMOVED BAD SECTION OF STRINGER BETWEEN STA 879-881 S18L AND REPLACED AND INSTALLED NEW STRINGER SPLICE AT STA 881 PER SRM 53-00-03-2R-1 REF SSDR SWAA2018073123884Crease Beam · damagedCREASE BEAM OUTER CHORD DAMAGED BETWEEN BS 817 TO BS 894, STR 17L. R&R CHORD PER EA.SDR SWAA2018073123885Shear Web · damagedCREASE BEAM SHEAR WEB DAMAGED BETWEEN BS 867 TO BS 887. R&R CHORD PER EA.SDR SWAA2018070223263Charger · faultyRT AFT CABIN EMERGENCY LIGHTS CHARGER CIRCUIT BREAKER FOUND OPEN. R&R BATTERY CHARGER IAW AMM.SDR SWAA2018062022929Shield · brokenAFT OUTBOARD EMERGENCY FLASH LIGHT SHIELD BROKEN. R&R SHIELD IAW SIP.SDR ASMF20180821004Warning Message · illuminatedAIRCRAFT REJECTED TAKEOFF WHEN TO/GA WAS PRESSED, THE TAKEOFF CONFIGURATION SOUNDS AND PSEU LIGHTTURNED ON. MAINTENANCE PERSONNEL PERFORM THE FIM 32-09 TASK 801 PROCEDURE AND IT WAS PERFORMED BITE TO PSEU IAW AMM 31-51-01, DETECTING PSEU LIGHT TURNED ON, MESSASDR SCNA201805232093Turnbuckle · crackedRIGHT WING TRAILING EDGE TURNBUCKLE BRACKET INBD OF DEFLECTION RIB WAS CRACKED. REMOVED AND REPALCED THE TURNBUCKLE.SDR SCNA201805232092Mount · corrodedAFT LAVATORY AFT INBD MOUNT HAD CORROSION EVIDENCE. REPAIRED THE MOUNT.SDR SCNA201805232091Plate · corrodedAFT CARGO PANEL "HOCKEY STICK" AND A SPLICE PLATE CORRODED, BOTHSIDE OF PLATES. REMOVED AND REPLACED AFT PIT PANEL HOCKEY STICK AND SPLICE PLATE.SDR SWAA2018052122129Battery Pack · dischargedEMERGENCY LIGHTS INOP AT LOCATION M2335. R&R BATTERY PACK PER AMM.SDR SWAA2018052122080Fuse · faultyLT OVERWING EMERGENCY EXIT LIGHTS FAULTY AT LOCATION M1668. R&R FUSE PER AMM.SDR SWAA2018052122079Battery Pack · dischargedEMERGENCY LIGHTS INOP AT LOCATION M1668. R&R BATTERY PACK PER AMM.SDR SWAA2018052122067Slide · unserviceableR2 DOOR EMERGENCY EVAC SLIDE FAILED INSPECTION CRITERIA. R&R SLIDE IAW MT.SDR SWAA2018050721746Light · inoperativeL2 DOOR EXTERIOR EMERGENCY LIGHT INOP. R&R LIGHT IAW AMM.SDR SWAA2018050721745Light · inoperativeLT EMERGENCY EXIT LIGHTS INOP BETWEEN ROW 6 TO ROW 24. CHARGED LIGHT IAW AMM.SDR SWAA2022021612281None · crackedPANEL BREAK CRACKED AT BS 540 LBL 25-45 WL 208. / REMOVED AND ISNTALLED NEW PANEL BREAK ASSYEMBLY AT BS 540 LBL 25-45 WL 208 IAW PER DRAWING #143A0060 REV: - SOPM 20-50-01 92421U 5-6-18SDR SWAA201805161636Circuit Breaker · malfunctionedRIGHT OVERWING DOOR LOWER EMERGENCY LIGHT INOPERATIVE. RESET THE CIRCUIT BREAKER IAW AMM.SDR SWAA2018050161621Circuit Breaker · malfunctionedAFT GALLEY CEILING EMERGENCY EXIT SIGN INOPERATIVE. RESET THE CIRCUIT BREAKER IAW AMM.SDR SWAA201805161620Circuit Breaker · malfunctionedRIGHT OVERWING DOOR EMERGENCY ESCAPE SLIDE LIGHT INOPERATIVE. RESET THE CIRCUIT BREAKER IAW AMM.SDR SWAA201805161618Circuit Breaker · malfunctionedRIGHT OVERWING DOOR UPPER EMERGENCY EXIT LIGHT INOPERATIVE. RESET THE CIRCUIT BREAKER IAW AMM.SDR SWAA201805161615Light · inoperativeLEFT EMERGENCY AISLE LIGHTS INOPERATIVE BETWEEN ROWS 17 TO 23. R & R THE LIGHT IAW AMM.SDR SWAA201805161614Circuit Breaker · malfunctionedRIGHT EMERGENCY AISLE LIGHTS INOPERATIVE BETWEEN ROWS 8 TO 19. RESET THE CIRCUIT BREAKER IAW AMM.SDR SCNA20180426080Structure · crackedFOUND A CRACK ON THE NR 2 LT LE SLAT. LENGTH OF CRACK IS 1.125 INCH. THE CRACK IS ACCEPTABLE TO FLY FOR 50FC. REMOVED AND REPLACED THE NR 2 LT L/E SLAT. OK FOR SERVICE.SDR SWAA2018051521930Support Angle · corrodedL1 DOOR THRESHOLD SUPPORT ANGLE CORRODED BETWEEN BS 320 TO 340, LBL 60. R & R THE SUPPORT ANGLE IAW SRM & DWG.SDR SWAA2018051521929Channel · corrodedR1 DOOR MOPSILL CORRODED BETWEEN BS 312 TO 325, RBL 60. R & R THE MOPSILL IAW SRM & DWG.SDR SWAA2018051521928Floor Support · crackedFLOOR SUPPORT CRACKED BETWEEN BS 244 TO 360, LBL 1. R & R THE FLOOR SUPPORT IAW SRM & DWG.SDR SWAA2018051521927Floor Support · crackedFLOOR SUPPORT CRACKED BETWEEN BS 312 TO 328, RBL 31. R & R THE FLOOR SUPPORT IAW SRM & DWG.SDR SWAA2018051521926Floor Support · crackedFLOOR SUPPORT CRACKED BETWEEN BS 277 TO 294.5, RBL 1. R & R THE FLOOR SUPPORT IAW SRM & DWG.SDR SWAA2018051521914Light · damagedAFT LOWERED CEILING EMERGENCY EXIT LIGHT INSERTS DAMAGED. R & R THE LIGHT ASSEMBLY IAW AMM.SDR SWAA2018042721435Slide · failed inspR1 DOOR SLIDE FAILED INSPECTION. R & R THE SLIDE ASSY IAW MM.SDR SWAA2018042721434Slide · failed inspL1 DOOR SLIDE FAILED AN INSPECTION. R & R THE SLIDE ASSY IAW MM.SDR SWAA2022021111591Spoiler · warped#6 SPOILER IS WARPED / REMOVED AND INSTALLED SERVICEABLE #6 SPOILER. IAW AMM 27-62-12-000-801. AMM 27-62-12-400-801. FOUND #6 SPOILER WARPED BAD FROM STCOK. TRANSFERED TO DEFECT NO. N129069. (POS:#6; TAG NO.:360715; P/N OFF:113A4600-5; S/N OFF:025494; P/N ON:1SDR SWAA2022021112235Floor Panel · crackedAFT CABIN WET AREA FLOOR PNL 241ACF HAS BROKEN INSERT AT STA 1008; L/H SIDE / REPAIRED DAMAGE AND REPLACED DAMAGED INSERT ON FLOOR PANEL 241ACF IAW SRM 53-00-50-2R-9. 56749U 27APR18SDR SWAA2022021112226Stiffener · crackedHORIZONTAL STIFFENER ON FWD SIDE OF BS663 RBL 8 IS CRACKED AT WL 160 / REMOVED AND REPLACED HORIZONTAL STIFFENER ON FWD SIDE OF BS 663 RBL8 WL160 IAW SRM 51-40-02 AND DWG 111A1000.SDR SWAA2022021112227Drag Brace · crackedVERTICAL DRAG BRACE IS CRACKED ON FWD SIDE OF BS 663 VAPOR BARRIER RBL 25 WL 154 / REMOVED AND REPLACED VERTICAL DRAG BRACE ON FWD SIDE OF BS 663 VAPOR BARRIER RBL 25 WL 154 IAW SRM 51-40-02 AND DWG 149A7210SDR ASMF20180625002Hmu · leakingDURING RIGHT ENGINE RUN DURING OVERNIGHT CHECK, A FUEL LEAK WAS DETECTED ON THE RIGHT ENGINE, BETWEEN FUEL PUMP AND HMU. THE FUEL PUMP AND HMU WERE REPLACED IAW AMM 73-11-01-000/400-801-F00, AND 73-11-01-400-801-F00, TESTED CORRECT.SDR SWAA2018051021845Threshold · corrodedORWARD CARGO BAY SUB THRESHOLD WEB CORRODED BETWEEN BS 450 TO BS 480, RBL 28. R&R WEB PER SRM AND DWG.SDR ASMF20180515011Fuel · leakingDURING RIGHT ENGINE RUN IN OVERNIGHT CHECK, A FUEL LEAK WAS DETECTED. MAINTENANCE PERSONNEL PERFORMED A REVISION DETECTING FUEL LEAK ON RIGHT ENGINE BETWEEN FUEL PUMP AND HMU; SO THE FUEL PUMP AND HMU WERE REPLACED IAW AMM TASKS 73-11-01-000/400-801-F00 AND 73SDR SWAA2022021112195Panel · crackedFAIRING PANEL # 195CL IS CRACKED IN THE RADIUS OF PANEL ON AFT END / FAIRING PANEL 195CL CRACK IN THE RADIUS ON THE AFT END WAS REPAIRED IAW SRM 51-70-05-2R-6SDR SWAA2022021112216Strap · corrodedACB; FLOOR PANEL SPLICE STRAP AT BS 772 HAS AREAS OF CORROSION FROM RBL10 TO LBL10 / ACB FLOOR PANEL SPLICE STRAP AT BS 772 FOUND TO BE OUT OF LIMITS DUE TO NO ALLOWABLE LIMITS IN THE SRM. RECEIVED NEW FLOOR PANEL SPLICE P.O.# 681622.
Back to Boeing 737-73V