Boeing 737-7H4
Service difficulty reports · 96,125
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7377H4' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7377H4' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2024081309164Attach Angle · crackedCRACKED INTERCOSTAL UPPER ATTACH ANGLE STA 380-400; RBL 9; WL 208.<[01] REMOVED AND REPLACED INTERCOSTAL UPPER ATTACH ANGLE STA 380-400; RBL 9 WL 208 PER SRM 51-10-02-0G-0 PAR 9 AND BOEING DWG 143A5400;[02] REMOVED AND REPLACED INTERCOSTAL UPPER ATTACH ANGLE SSDR SWAA2024081309161Support Angle · corrodedCORROSION ON FWD ENTRY MOPSILL SUPPORT ANGLE 314-326; LBL 57-58; WL 209.<[01] UPDATED STEPS AND TABLE.;[02] PARTIAL UPDATE STEP 3;[03] UPDATED STEP 4; DWG REVISION #; 141A8112 REV:-;[04] CERTIFY UPDATE.;[05] REMOVED AND REPLACED FED MOPSILL SUPPORT ANGE PER SRSDR SWAA2024081309152Sill Drain · crackedFWD MOPSILL IS CRACKED AT STA 303; LBL 58; WL 209.<[01] UPDATED MEASUREMENT TABLE AND STEPS.;[02] STEP 4 UPDATE;[03] UPDATED STEP 4 DWG REVISION#; DWG 141A8110 REV:E;[04] CERTIFY;[05] REMOVED AND REPLACED FED MOP SILL BETWEEN BS 270 TO BS 360 ; LBL 58 ;WL 209 SDR SWAA2024081309155Intercostal · crackedCRACKED INTERCOSTAL STA 344-360; RBL 12; WL 208.<[01] REMOVED AND REPLACED INTERCOSTAL FROM BS 344 TO BS 360; RBL 12 AND BOEING DWG 141A5400 ID: 13.;[02] VERIFIED CORRECTIVE ACTION 1SDR SWAA2024081309157Intercostal · crackedCRACKED INTERCOSTAL STA 312-328; LBL 44; WL 208.<[01] REMOVED AND REPLACE INTERCOSTAL STA 312-328; LBL 44; WL 208. AND BOEING DWG 141A5400 PER SRM 51-40-02-0G-0.;[02] VERIFIED CORRECTIVE ACTION 1.SDR SWAA2024081309158Intercostal · crackedCRACKED INTERCOSTAL STA 328-344; LBL 44; WL 208.<[01] REMOVE AND REMPLACE INTERCOSTAL STA 328-344; LBL 44; WL 208 AND BOEING DWG 141A5400 PER SRM 51-40-02-0G-0.;[02] VERIFIED CORRECTIVE ACTION 1.SDR SWAA2024081309138Panel · debondedPANEL 195CL PREVIOUS REPAIR AT AFT EDGE CORNER RADIUS IS DISBONDED.<[01] PANEL 195CL DISBONDED PREVIOUS REPAIR AT AFT EDGE CORNER RADIUS WAS REPAIRED IAW SRM 51-70-05-2R-6;[02] VERIFIED CORRECTIVE ACTION 1SDR SWAA2024080909114Floor Panel · pulledFWD FLOOR PANEL 221AF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] AREAS OF PULLED STRANDS ON UPPER SURFACE OF FWD FLOOR PANEL 221AF WERE REPAIRED IAW SRM 53-00-50-2R-1.;[02] JOB COMPLETE.SDR SWAA2024080909115Floor Panel · pulledFWD FLOOR PANEL 221CF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] AREAS OF PULLED STRANDS ON UPPER SKIN OF FWD FLOOR PANEL 221CF WERE REPAIRED IAW SRM 53-00-50-2R-1.;[02] JOB COMPLETE.SDR SWAA2024080909123Floor Panel · pulledFWD FLOOR PANEL 222AF UPPER SKIN HAS AREAS OF PULLED STRANDS ALONG THE O/B EDGE.<[01] FWD FLOOR PANEL 222AF HAD PULLED STRANDS REPAIRED IAW SRM 53-00-50-2R-1;[02] VERIFIED COMPLETESDR SWAA2024080909125Floor Panel · pulledFWD FLOOR PANEL 222CF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] FORWARD FLOOR PANEL 222CF UPPER SKIN AREAS OF PULLED STRANDS WAS REPAIRED IAW SRM 53-00-50-2R-1.;[02] JOB COMPLETE.SDR SWAA2024080909126Floor Panel · pulledFWD FLOOR PANEL 222DF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] FORWARD FLOOR PANEL 222DF UPPER SKIN WITH AREAS OF PULLED STRANDS WAS REPAIRED IAW SRM 53-00-50-2R-1.;[02] VERIFIED COMPLETESDR SWAA2024080909129Floor Panel · pulledFWD FLOOR PANEL 232BF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] FWD FLOOR PANEL 232BF UPPER SKIN HAD AREAS OF PULLED STRANDS REPAIRED IAW SRM 53-00-50-2R-1;[02] VERIFIED CORRECTIVE ACTION ITEM 1.SDR SWAA2024080909122Floor Panel · pulledFWD FLOOR PANEL 221FF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] FWD FLOOR PANEL 221FF UPPER SKIN WITH AREAS OF PULLED STRANDS WAS REPLACED WITH A SERVICEABLE FLOOR PANEL PER SRM 51-10-02-0G-0 PARA 9.A.1 DUE TO AMOUNT OF ALL DAMAGE.;[02] JOB COMPLETE.SDR SWAA2024080909117Floor Panel · pulledFWD FLOOR PANEL 221GF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] FWD FLOOR PANEL 221GF UPPER SKIN WITH AREAS OF PULLED STRANDS WAS REPLACED WITH A SERVICEABLE FLOOR PANEL PER SRM 51-10-02-0G-0 PARA 9.A.1 DUE TO AMOUNT OF ALL DAMAGE.;[02] JOB COMPLETE.SDR SWAA2024080909124Floor Panel · pulledFWD FLOOR PANEL 222BF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] DUE TO THE EXTENT OF DAMAGE; REPLACED FWD FLOOR PANEL 222BF IAW SRM 51-10-02-0G-0 PARA 9 AND AIPC 53-21-00-50D ITEM 96.;[02] VERIFIEDSDR SWAA2024080909120Floor Panel · pulledFWD FLOOR PANEL 221BF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] FWD FLOOR PANEL 221BF UPPER SKIN WITH AREAS OF PULLED STRANDS WAS REPLACED WITH A SERVICEABLE FLOOR PANEL PER SRM 51-10-02-0G-0 PARA 9.A.1 DUE TO AMOUNT OF ALL DAMAGE.;[02] JOB COMPLETE.SDR SWAA2024080909116Floor Panel · pulledFWD FLOOR PANEL 221EF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] FWD FLOOR PANEL 221EF UPPER SKIN WITH AREAS OF PULLED STRANDS WAS REPLACED WITH A SERVICEABLE FLOOR PANEL PER SRM 51-10-02-0G-0 PARA 9.A.1 DUE TO AMOUNT OF ALL DAMAGE.;[02] JOB COMPLETE.SDR SWAA2024080909118Floor Panel · pulledFWD FLOOR PANEL 231CF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] FWD FLOOR PANEL 231CF UPPER SKIN WITH AREAS OF PULLED STRANDS WAS REPLACED WITH A SERVICEABLE FLOOR PANEL PER SRM 51-10-02-0G-0 PARA 9.A.1 DUE TO AMOUNT OF ALL DAMAGE.;[02] JOB COMPLETE.SDR SWAA2024080909128Floor Panel · pulledFWD FLOOR PANEL 232AF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] FWD FLOOR PANEL 232AF UPPER SKIN WITH AREAS OF PULLED STRANDS WAS REPLACED WITH A SERVICEABLE FLOOR PANEL PER SRM 51-10-02-0G-0 PARA 9.A.1 DUE TO AMOUNT OF ALL DAMAGE.;[02] JOB COMPLETE.SDR SWAA2024080709054Access Panel · crackedCRACK LEADING EDGE RIB ACCESS PANEL 331B LOCATED LE STA198.23 LT HORIZONTAL STAB 2024-405175<[01] REPLACED RIB LOC ON LEADING EDGE STA198.23 ACCESS PANEL 331B HORIZONTAL STABILIZER LH IAW B737-700 SRM 51-40-02 AND SRM 51-10-02 ITEM 9. DWG 186A1001; SHEET 11; RSDR SWAA2024080709053Rib · crackedCRACK LEADING EDGE RIB ACCESS PANEL 331B LOCATED LE STA188.94 LT HORIZONTAL STAB 2024-405174<[01] REPLACED NEW RIB 188.94 AND FASTENERS LOCATED ON LEADING EDGE HORIZONTAL STABILIZER ACCESS PANEL 331B LH IAW B737-700 SRM 51-40-02 AND DWG 186A1001 SHEET 11 REV: SDR SWAA2024070908947Slide · out of adjustCUSTOMER WALK - L2 DOOR SLIDE SKIRT HITS THRESHOLD WHEN CLOSING<[01] READJUSTED THE GIRT Z-FOLD ON L2 DOOR SLIDE REF 'TASK CARD '725-61-06 (REM/INST - SLIDE REMOVAL AND INSTALLATION) [TTG8Q00UDDC3]' FOR WORK ACCOMPLISHED.;[02] VERIFIED STEP 1<BR>AUDIT C/W REF SDR SWAA2024070908953Slide · out of adjustCUSTOMER WALK - R2 DOOR SLIDE SKIRT HITS THRESHOLD WHEN CLOSING<[01] REFER TO TASK CARD '725-61-06 (REM/INST - SLIDE REMOVAL AND INSTALLATION) [TTG8Q00UDCAY]' FOR WORK ACCOMPLISHED.;[02] CORRECTION STEP 1. READJUSTED THE GIRT Z-FOLD ON R2 DOOR SLIDE REF TASK CSDR SWAA2024070908946Bulb · burned outCUSTOMER WALK - SEVERAL BULBS BURNT OUT ON EMER EXIT SIGN ON AFT GALLEY OUTBD SIDE<[01] RELAMPED BULBS ON EMER EXIT SIGN ON AFT GALLEY OUTBD SIDE AS PER B737 AMM 33-51-01-960-801. OPERATIONAL TEST PASSED.;[02] VERIFIED STEP 1.SDR SWAA2024070509329Slide · dislodgedFWD SERVICE DOOR SLIDE FALLING OUT OF COVER<[01] RESECURED SLIDE PER MT 725-61-06SDR SWAA2024070509256Sign · brokenRH OVERWING UPPER AND FWD EXIT SIGNS INOP.<[01] REMOVED AND REPLACED BATTERY CHARGER M1669 REF: AMM 33-51-06. FOUND FWD SIGN ASSEMBLY TO BE BROKEN. REMOVED AND REPLACED RH FWD OVERWING EXIT SIGN ASSEMBLY REF: AMM 33-51-01. ALL LIGHTS NOW CHECK GOOD.SDR SWAA2024082609176Vapor Barrier · crackedCRACK ON VAPOR BARRIER LOCATED BS663 LBL52 AND WL160 CENTER WING BOX 2024-420712<[01] TOOL USED: CALIPER P/N: 500-197-30 S/N: 15120589 DUE DATE: 13-FEB-24.;[02] CORRECTED STEP 1 TOOL USED: CALIPER P/N: 500-464 S/N: B17030933 DUE DATE: 07-NOV-24.;[03] TOOL USEDSDR SWAA2024082608782Pressure Deck · crackedCRACK INDICATION ON HORIZONTAL PRESSURE DECK WEB RBL 40 STA 663 AT PASSENGER CABIN (1E/A). CRACK LENGTH APPROX. 0.130 INCH 2024-420684<[01] STEP 6 TOOL USED EDDY CURRENT EQUIPMENT PN: NORTEC 600D; SN: 220272512; DUE DATE: 08-JAN-25;[02] PERFORMED PERMANENT REPSDR SWAA2024082608780Pressure Deck · crackedCRACK INDICATION ON HORIZONTAL PRESSURE DECK WEB LBL 30 STA 663 AT PASSENGER CABIN (1E/A). CRACK LENGTH APPROX. 0.187 INCH 2024-420685<[01] TOOL USED ON STEP 6; AND STEP 7: EDDY CURRENT EQUIPMENT P/N: NORTEC 600D; S/N: 220272712; DUE DATE: 28/NOV/2024;[02] TOOSDR SWAA2024082609174Access Panel · delaminatedDELAMINATED ACCESS PANEL 193CL BODY FAIRING AFT EDGE AT LOWER FUSELAGE 2024-420703<[01] TOOL USED; CALIPER PN: 500-197-30; SN: A18229508; DUE DATE: 14/JAN/25.;[02] TOOL USED HOT BONDER PN: HCS9200B-AV; SN: 18196127; DUE DATE: 25/JAN/25.;[03] TOOL USED: HOT BONSDR SWAA2024081309096Floorbeam · corrodedCORROSION ON TOP FLANGE OF BS 986.5 FLOOR BEAM RBL 45-RBL 28 AND LBL 44 WL 208<[01] COMPLETED STEP 1; UPDATED TABLE;[02] EDITED STATEMENT;[03] EVALUATED CORROSION ON TOP FLANGE OF BS 986.5 FLOOR BEAM RBL 45-RBL 28 AND LBL 44 WL 208. FOUND TO BE OUT OF LIMITS DSDR SWAA2024081309093Seat Track · corrodedCORROSION ON PASSENGER CABIN SEAT TRACK IN THE WELL; RBL45 BS727E+10; BS800; BS831; BS840 WL208.<[01] COMPLETED STEP 1 AND STEP 2.;[02] COMPLETED STEP 4.;[03] EDIT TO STEP #5; DWG REVISION.;[04] ADDITIONAL FABRICATION EDIT TO STEP #5;[05] CERTIFY;[06] SUMMERY SDR SWAA2024081309100Seat Track · corrodedCORROSION ON PASSENGER CABIN SEAT TRACK IN THE WELL LBL45 BS500D+10 WL208.<[01] SEAT TRACK TO BE RELACED ON TTG8Q00UCL0H.;[02] CORRECTED MEASUREMENT TABLE STEPS 1;2; AND 3.;[03] VERIFIED. CARD COMPLETE.SDR SWAA2024081309101Seat Track · corrodedCORROSION ON PASSENGER CABIN SEAT TRACK IN THE WELL LBL45 BS727; BS727A+12 WL208.<[01] COMPLETED STEPS 1; 2 AND 3.;[02] COMPLETED STEP 5;[03] REMOVED AND REPLACED PASSENGER CABIN SEAT TRACK FROM LBL 45 BS 540 TO BS 727B WL 208 PER SRM 51-40-02-0G-0 AND BOEING SDR SWAA2024081308771Panel · crackedL/W L/E PANEL 521TB CORNER IS CRACKED<[01] L/W L/E PANEL 521TB CORNER WITH CRACKED WAS REPAIRED IAW SRM 51-70-05-2R-6.;[02] VERIFIED CORRECTIVE ACTION 1.SDR SWAA2024080908760Skin · crackedCRACK FOUND DURING HFEC INSPECTION OF LH HORIZONTAL STABILIZER LOWER SKIN AT STAB STA 193.90; 18' FROM FWD EDGE; L: 0.5' MARKED<[01] REPAIRED DAMAGE TO LH HORIZONTAL STABILIZER LOWER SKIN AT STAB STA 193.9; 18' FROM FWD EDGE; L: 0.5' IAW SRM 55-10-01-2R-11.;[0SDR SWAA2024080908576Floor Panel · pulledAFT FLOOR PANEL 241YF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] 241YF AFT FLOOR PANEL UPPER SKIN DAMAGE HAS BEEN REPAIRED IAW SRM 53-00-50-2R-1 AND BOEING DWG: 147A5810 ID: 0077.<BR><BR>ATTACHED CURE SHEETS TO THIS FAULT.;[02] JOB COMPLETE.SDR SWAA2024080908577Floor Panel · pulledAFT FLOOR PANEL 241ABF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] 241ABF AFT FLOOR PANEL UPPER SKIN HAS BEEN REPAIRED IAW SRM 53-00-50-2R-1 AND BOEING DWG: 147A5810 ID: 0088.<BR><BR>ATTACHED CURE SHEETS TO THIS FAULT.;[02] VERIFIED CORRECTIVE ACTION #1SDR SWAA2024080908571Floor Panel · pulledAFT FLOOR PANEL 241ADF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] REPAIRED AREA OF PULLED STRANDS ON UPPER SKIN AND DAMAGED AREA FOUND ON LOWER SKIN ON AFT FLOOR PANEL 241ADF IAW SRM 53-00-50-2R-1.;[02] VERIFIED CORRECTIVE ACTION 1SDR SWAA2024080908574Floor Panel · pulledAFT FLOOR PANEL 242UF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] 242UF AFT FLOOR PANEL UPPER SKIN DAMAGE HAS BEEN REPAIRED IAW SRM 53-00-50-2R-1 AND BOEING DWG: 147A5810 ID: 0095.<BR><BR>ATTACHED CURE SHEETS TO THIS FAULT.;[02] JOB COMPLETE.;[03] RII INSPECTSDR SWAA2024080908578Floor Panel · pulledAFT FLOOR PANEL 242VF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] 242VF AFT FLOOR PANEL UPPER SURFACE DAMAGE HAS BEEN REPAIRED IAW SRM 53-00-50-2R-1 AND BOEING DWG: 147A5810 ID: 0350.<BR><BR>ATTACHED CURE SHEETS TO THIS FAULT.;[02] JOB COMPLETE.SDR SWAA2024080908569Stiffener · crackedRIGHT HORIZONTAL STAB RIB #4 STIFFENERS 2 & 3 ARE CRACKED IN THE LOWER RADIUS.<[01] REPAIRED R/ HOR. STAB. RIB #4; STIFFENER 2 IAW SRM 55-10-09-2R-4 REPAIR 4; FIG. 202; DETAIL A AND SRM 51-40-05-02-0G-0.;[02] VERIFIED CORRECTIVE ACTION ITEMS AND STEPS; CARD COSDR SWAA2024080908566Floor Panel · debondedCABIN FLOOR PANEL 241BF UPPER SKIN HAS A LARGE DISBOND NEAR CENTER OF PANEL.<[01] DUE TO THE EXTENT OF DAMAGE; FABRICATED NEW CABIN FLOOR PANEL 241BF IAW SRM 53-00-50-2R-0 AND BOEING DWG 144A5810 ID: 0189;[02] VERIFIED COMPLETESDR SWAA2024080908575Floor Panel · pulledAFT FLOOR PANEL 241UF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] AFT FLOOR PANEL 241UF UPPER SKIN WITH AREAS OF PULLED STRANDS WAS REPLACED WITH A SERVICEABLE FLOOR PANEL PER SRM 51-10-02-0G-0 PARA 9.A.1 DUE TO AMOUNT OF ALL DAMAGE.;[02] VERIFIED CORRECTIVE SDR SWAA2024080909107Floor Panel · deformedCABIN FLOOR PANEL 241CF LOWER SKIN HAS AN IMBEDDED SCREW. (MARKED)<[01] FABRICATION OF NEW 241CF FLOOR PANEL WAS ACCOMPLISHED IAW SRM 53-00-50-2R-0 AND BOEING DWG: 144A5810 ID: 0130.<BR><BR>ATTACHED CURE SHEET TO THIS FAULT.;[02] VERIFIED CORRECTIVE ACTION #1SDR SWAA2024072909167Doubler · crackedCRACK FOUND AT RT HORIZONTAL STABILIZER LOWER SKIN AT STAB STA 193.90 ; 16' FROM LEADING EDGE ;I/B ROW. CRACK LENGTH : 1'. CRACK FOUND AT RT HORIZONTAL STABILIZER LOWER SKIN AT STAB STA 193.90 16' FROM LEADING EDGE I/B ROW. CRACK LENGTH : 1'.<[01] REMOVED FASTSDR SWAA2024070809245Floor Panel · crackedAFT CARGO PIT FLOOR PANEL FORWARD OF ENTRY WAY HAS A CRACK / TEAR COMPLETELY THROUGH THE FIGER GLASS PANEL<[01] OK TO CONTINUE PER MEL 25-16-01 SP1B PLACARD INSTALLED;[02] REMOVED AND REPLACED AFT CARGO FLOOR PANEL FORWARD OF ENTRY WAY PER AMM 25-52-10SDR SWAA2024070508699Light · detachedPHOTOLUMNICENT STRIP DETACHED ROW 1 AIRCRAFT RIGHT<[01] REINSTALLED PHOTOLUMINESCENT STRIP REF AMM 33-51-15SDR SWAA2024070508668Lens · missingLH OVERWING EXIT SIGN NEAR FLOOR MISSING LENS COVER<[01] REPLACED LENS IAW AMM 33-51-01
Back to Boeing 737-7H4