Boeing 737-7H4
Service difficulty reports · 96,125
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7377H4' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7377H4' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2024031453142Nut Plate · corrodedCORROSION ON NUTPLATES AT ACB BS727D BL0 WL150.<[01] CUMPLETED STEP 1;[02] TASK CARD COMPLETED;[03] VERIFIED CORRECTIVE ACTION COMPLETE.<BR>VERIFIED MEASUREMENT TABLE.SDR SWAA2024031453145Cargo Track · corrodedCORROSION ON TRACK TIEDOWN AT FCB BS436; BS496; BS500 LBL18 WL156.<[01] REMOVED AND REPLACED TIEDOWN TRACK AT FCB BS 396 TO BS 500D LBL 18 WL 156 IAW BOEING DWG 143A7500 AND SRM 51-40-02;[02] 02 - INSPECTED PER [SRM 53-00-53-1A-2-A00028 (PERMANENT (NON-DENT DASDR SWAA2024031453147Shield · corrodedCORROSION ON AFT SHIELD AT FCB BS500 RBL23 WL156.<[01] REMOVED AND REPLACED FCB BAY AFT NEW SHIELD P/N 143A8126-31 LOT#1553496-2 PO#960004/2 AT BS 480+15 TO BS 500A RBL 23; WL 156 IAW SRM 51-40-02 AND DWG 143A0080 REV: -;[02] VERIFIED RII CORRECTIVE ACTION ITESDR SWAA2024031452976Angle · crackedCRACK ON ANGLE LOCATED SLAT 8 AUXILIARY TRACK INBOARD SIDE AT RT WING 2024-123335<[01] REMOVED AND REPLACED ANGLE LOCATED ON AUXILIARY TRACK 8 INBOARD SIDE AT RT WING IAW B737-700 SRM 51-40-02 AND SRM 51-10-02 ITEM 9 AND PERFORMED INBOARD AUXILIARY TRACK SKIN SDR SWAA2024031353125Panel · crackedMULTIPLES CRACKS ON PANEL 211B (MARKED)<[01] REMOVED AND REPLACED PANEL 211B PER SOPM 20-50-01.;[02] UPDATED MEASUREMENT TABLE.;[03] VERIFIED.SDR SWAA2024031353005Floor Support · crackedFWD WET AREA - CRACK ON INTERCOSTAL BS 344+9 BL 0 WL 208 (MARKED)<[01] UPDATED STEPS;[02] UPDATED MEASUREMENT TABLE;[03] SUMMARY; THE CRACKED INTERCOSTAL AT BS 344 BL0 WAS REMOVED AND REPLACED IAW SRM 51-10-02-0G-0 STEP 9 A (1) (2).;[04] REJECT: IMPROPERLY INSSDR SWAA2024031353006Floor Support · crackedFWD WET AREA - CRACK ON INTERCOSTAL BS 277+7.5 BL 0 WL 208 (MARKED<[01] UPDATED STEPS;[02] UPDATED STEP;[03] UPDATED MEASUREMENT TABLE;[04] VERIFIED STEPS 1;2;3;4; COMPLETE; STEP 5 IN PARTIAL.;[05] STEP #5 COMPLETE;[06] CUSTOMER CARD COMPLETE AND VERIFIED MEASSDR SWAA2024031352838Floor Panel · pulledAFT FLOOR PANEL 241AAF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] FABRICATED NEW AFT FLOOR PANEL 241AAF IAW SRM 53-00-50-2R-0 AND BOEING DWG 147A5810 ID:0008;[02] VERIFIED CORRECTIVE ACTION ITEM 1.SDR SWAA2024031352840Floor Panel · pulledAFT FLOOR PANEL 242WF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] DUE TO THE EXTENT OF DAMAGE; REPLACED AFT FLOOR PANEL 242WF IAW SRM 51-10-02-0G-0 PARA 9 AND AIPC 53-21-00-26 ITEM 195.;[02] VERIFIED CORRECTIVE ACTION ITEM 1.SDR SWAA2024031352826Floor Panel · pulledFLOOR PANEL 241UF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] FLOOR PANEL 241UF UPPER SKIN WITH AREAS OF PULLED STRANDS WAS REPLACED WITH A SERVICEABLE FLOOR PANEL PER SRM 51-10-02-0G-0 PARA 9.A.1 DUE TO AMOUNT OF ALL DAMAGE.;[02] JOB COMPLETE.SDR SWAA2024031352841Floor Panel · pulledFWD FLOOR PANEL 221BF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] FWD FLOOR PANEL 221BF UPPER SKIN WITH AREAS OF PULLED STRANDS WAS REPLACED WITH A SERVICEABLE FLOOR PANEL PER SRM 51-10-02-0G-0 PARA 9.A.1 DUE TO AMOUNT OF ALL DAMAGE.;[02] JOB COMPLETE.SDR SWAA2024031352828Floor Panel · pulledFWD FLOOR PANEL 221DF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] FWD FLOOR PANEL 221DF UPPER SKIN WITH AREAS OF PULLED STRANDS WAS REPLACED WITH A SERVICEABLE FLOOR PANEL PER SRM 51-10-02-0G-0 PARA 9.A.1 DUE TO AMOUNT OF ALL DAMAGE.;[02] JOB COMPLETE.SDR SWAA2024031352831Floor Panel · pulledFWD FLOOR PANEL 222BF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] FWD FLOOR PANEL 222BF UPPER SKIN WITH AREAS OF PULLED STRANDS WAS REPLACED WITH A SERVICEABLE FLOOR PANEL PER SRM 51-10-02-0G-0 PARA 9.A.1 DUE TO AMOUNT OF ALL DAMAGE.;[02] JOB COMPLETE.SDR SWAA2024031352834Floor Panel · pulledFWD FLOOR PANEL 231AF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] FWD FLOOR PANEL 231AF UPPER SKIN WITH AREAS OF PULLED STRANDS WAS REPLACED WITH A SERVICEABLE FLOOR PANEL PER SRM 51-10-02-0G-0 PARA 9.A.1 DUE TO AMOUNT OF ALL DAMAGE.;[02] JOB COMPLETE.SDR SWAA2024031352835Floor Panel · pulledFWD FLOOR PANEL 231BF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] DUE TO EXTENT OF DAMAGE FLOOR PANEL 231BF WAS REPLACED IAW SRM 51-10-02-0G-0 PAR 9.A (1).;[02] VERIFIED CORRECTIVE ACTION 1SDR SWAA2024031353108Angle · crackedCRACK ANGLE - CLIP LOCATED BS440 AND STR26L FWD CARGO COMPARTMENT 2024-123350<[01] REPLACED ANGLE - CLIP LOCATED BS440 AND STR26L FWD CARGO COMPARTMENT; WEB-INTERCOSTAL AND FASTENER LOCATED BETWEEN STA440 TO STA 460 IAW B737-700 SRM 51-10-02-0G-0 AND DWG 143A7SDR SWAA2024031353109Angle · crackedCRACK ANGLE - CLIP LOCATED BS500C AND STR26L FWD CARGO COMPARTMENT 2024-123351<[01] INSTALLED ANGLE - CLIP LOCATED BS500C AND STR26L FWD CARGO COMPARTMENT; WEB-INTERCOSTAL AND FASTENER LOCATED BETWEEN STA 500C TO STA 500D IAW B737-700 SRM 51-10-02-0G-0 AND DWGSDR SWAA2024031252836Floor Panel · pulledAFT FLOOR PANEL 241XF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] PULLED STRANDS ON AFT FLOOR PANEL 241XF UPPER SKIN HAVE BEEN REPAIRED IAW SRM 53-00-50-2R-1.;[02] FINAL INSPECTION. JOB COMPLETE.SDR SWAA2024031252837Floor Panel · pulledAFT FLOOR PANEL 241ZF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] AFT FLOOR PANEL 241ZF UPPER SKIN DAMAGE HAS BEEN REPAIRED IAW SRM 53-00-50-2R-1.<BR><BR>ATTACHED CURE SHEETS TO THIS FAULT.;[02] VERIFIED REPAIR OF FLOOR PANEL 241ZF UPPER SKIN IAW SRM 53-00-50SDR SWAA2024031252821Floor Panel · pulledAFT FLOOR PANEL 241ABFF UPPER SKIN HAS AREAS OF PULLED STRANDS. PANEL SHOULD BE 241ABF<[01] AREAS OF PULLED STRANDS ON FLOOR PANEL 241ABF WERE REPAIRED IAW SRM 53-00-50-2R-1.<BR><BR>DOWNLOADED CURE SHEETS AND TAPE.;[02] VERIFIED FLOOR PANEL 241ABF WAS REPAIREDSDR SWAA2024031252839Floor Panel · pulledAFT FLOOR PANEL 241ACF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] AFT FLOOR PANEL 241ACF UPPER AND LOWER SKIN DAMAGED AREAS HAVE BEEN REPAIRED IAW SRM 53-00-50-2R-1.<BR><BR>ATTACHED CURE SHEETS TO THIS FAULT.;[02] VERIFIED REPAIR OF FLOOR PANEL 241ACF PER SRSDR SWAA2024031252822Floor Panel · pulledAFT FLOOR PANEL 241ADF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] AREAS OF PULLED STRANDS ON AFT FLOOR PANEL 241ADF UPPER SKIN WAS REPAIRED IAW SRM 53-00-50-2R-1.;[02] FINAL INSPECTION. JOB COMPLETE.SDR SWAA2024031252823Floor Panel · pulledAFT FLOOR PANEL 242TF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] AFT FLOOR PANEL 242TF UPPER SKIN AREAS OF PULLED STRANDS WERE REPAIRED IAW SRM 53-00-50-2R-1.;[02] VERIFIED REPAIR OF FLOOR PANEL 242TF UPPER SKIN IAW SRM 53-00-50-2R-1.;[03] WORKSCOPE IS COMPLSDR SWAA2024031252825Floor Panel · pulledAFT FLOOR PANEL 242VF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] AFT FLOOR PANEL 242VF WITH UPPER SKIN HAS AREAS OF PULLED STRANDS WAS REPAIRED IAW SRM 53-00-50-2R-1.;[02] VERIFIED CORRECTIVE ACTION 1SDR SWAA2024031252842Floor Panel · pulledFWD FLOOR PANEL 221CF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] REPAIRED AREAS OF PULLED STRANDS ON UPPER SKIN OF FWD FLOOR PANEL 221CF IAW SRM 53-00-50-2R-1.;[02] VERIFIED CORRECTIVE ACTION ITEM 1.SDR SWAA2024031252843Floor Panel · pulledFWD FLOOR PANEL 221EF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] PULLED STRANDS ON UPPER SKIN OF FWD FLOOR PANEL 221EF WERE REPAIRED IAW SRM 53-00-50-2R-1.;[02] VERIFIED CORRECTIVE ACTION 1.SDR SWAA2024031252830Floor Panel · pulledFWD FLOOR PANEL 222AF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] AREAS OF PULLED STRANDS ON UPPER SKIN OF FWD FLOOR PANEL 222AF WAS REPAIRED IAW SRM 53-00-50-2R-1.;[02] FINAL INSPECTION. JOB COMPLETE.SDR SWAA2024031252832Floor Panel · pulledFWD FLOOR PANEL 222CF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] FWD FLOOR PANEL 222CF UPPER SKIN WAS REPAIRED IAW SRM 53-00-50-2R-1 AND BAC DWG 141A5810 ID: 245.;[02] INFORMATION ENTERED ON ITEM 1 WAS ENTERED IN ERROR. THIS IS AN INSPECTOR BLOCK.;[03] FWD FSDR SWAA2024031252833Floor Panel · pulledFWD FLOOR PANEL 222DF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] FWD FLOOR PANEL 222DF WITH UPPER SKIN PULLED STRANDS WAS REPAIRED IAW SRM 53-00-50-2R-1 AND BAC DWG 141A5810 ID:185.;[02] VERIFIED CORRECTIVE ACTION 1.SDR SWAA2024031253146Support · corrodedCORROSION ON FLOOR TO SIDEWALL SUPPORT AT FCB BS460 - BS500C LBL23 WL156.<[01] VERIFIED STEP 15 IN PARTIAL.;[02] VERIFIED STEP 16 COMPLETE.;[03] REJECT - INSTALLATION OF SIDEWALL SUPPORT; FOUND CRACK AT INTERCOSTAL FASTENER ATTACHMENT POINT; BS460; WL156; LBL2SDR SWAA2024030752957Doubler · crackedREPLACE PREVIOUS REPAIR AT EXTERNAL POWER DOOR INNER DOUBLER CUTOUT SKIN AFT EDGE<[01] REMOVED PREVIOUS REPAIR (INNER DOUBLER CUTOUT SKIN AFT EDGE) AT EXTERNAL POWER DOOR AS PER SRM 51-40-02-0G-0 AND SRM 53-10-15-2R-4. INSTALLED INNER DOUBLER AND RUBBING BLOCKSDR SWAA2024022052861Seat Track · elongatedFIRST OFFICERS SEAT I/B AFT TRACK FAILS ADJUSTMENT HOLE INSPECTION<[01] REMOVED AND REPLACED FIRST OFFICERS SEAT I/B AFT TRACK PER AMM 25-11-11SDR SWAA2024021952858Battery Pack · failedEMX BATT PACK M01669 FAILS CAPACITANCE CHECK<[01] REMOVED AND REPLACED EMX BATT M01669 PER AMM 33-51-06SDR SWAA2024021952857Battery Pack · failedEMX BATT M01672 FAILS CAPACITANCE CHECK<[01] REMOVED AND REPLACED EMX BATT PACK M01672 PER AMM 33-51-06SDR SWAA2024021952779Light · missingFWD ENTRY DOOR LOWER FWD EMERGENCY EXIT LIGHT LENS MISSING DIRECTIONAL ARROW<[01] REMOVED AND REPLACED LENS IAW AMM 33-51-01SDR SWAA2024021952776Lens · missingLEFT OVERWING EMERGENCY EXIT LOWER FWD EMERGENCY LIGHT LENS DIRECTIONAL ARROW POINTING IN WRONG DIRECTION<[01] REMOVED AND REPLACED LENS IAW AMM 33-51-01SDR SWAA2024021952775Lens · missingRIGHT OVERWING EMERGENCY EXIT LOWER FWD EMERGENCY LIGHT LENS MISSING DIRECTIONAL ARROW<[01] REMOVED AND REPLACED LENS IAW AMM 33-51-01SDR SWAA2024021952856Seal · crackedR/H HORIZONTAL STABILIZER FWD UPPER SLIDE SEAL CRACKED<[01] REMOVED AND REPLACED R/H HORIZONTAL STABILIZER FWD UPPER SLIDE SEAL IAW BOEING 737 AMM 53-31-31. OPS CHECK GOOD.SDR SWAA2024021952855Seal · crackedL/H HORIZONTAL STABILIZER FWD UPPER SLIDE SEAL CRACKED<[01] REMOVED AND REPLACED L/H HORIZONTAL STABILIZER FWD UPPER SLIDE SEAL IAW BOEING 737 AMM 53-31-31.SDR SWAA2024021952860Cargo Track · out of adjustCAPT I/B AFT SEAT TRACK FAILS ADJUSTMENT HOLE INSPECTION<[01] REMOVED AND REPLACED CAPT I/B AFT SEAT TRACK PER AMM 25-11-11SDR SWAA2024021952758Support Bracket · crackedRH WING UPPER T/E SHELF PANEL SUPPORT BRACKET CRACKED (BULB SEAL IS ATTACHED TO THE BRAKET)<[01] REMOVE AND REPLACED THE R/H WING UPPER T/E PANEL SUPPORT BRACKET PER SRM 51-40-02.;[02] C/W INSPECTIONSDR SWAA2024031552656Floor Panel · crackedCRACK FLOOR PANEL 241AEF AT PASSENGER CABIN 2024-124097<[01] TOOL USED: CALIPER P/N: 500-197-30 S/N: B20189520 DUE DATE: 17-JAN-25;[02] TOOL USED: HOT BONDER P/N:HCS9200B-AV; S/N:18196126 DUE DATE:26/MAR/24;[03] TOOL USED: SCALE P/N: SCA-301; S/N: AE-412135; DSDR SWAA2024031552660Stringer · crackedCRACK STRINGER 23L LOCATED ON BS 540 AT FWD CARGO COMPARTMENT 2024-123960<[01] TOOL USED: EDDY CURRENT EQUIPMENT; P/N: NORTEC600D; S/N: 220272512; CAL DUE DATE: 08-JAN-25;[02] TOOLS USED: POWER PACK P/N: P3015GOES00000; S/N: 142811020; DUE DATE: 23-JAN-25; POWSDR SWAA2024031452452Skin · debondedPANEL 194CL OUTER SKIN HAS 2 TIGHTLY GROUPED DISBONDS NEAR CENTER OF PANEL. (MARKED)<[01] PANEL 194CL OUTER SKIN DAMAGE HAS BEEN REPAIRED IAW SRM 51-70-05-2R-2.<BR><BR>ATTACHED CURE SHEET TO THIS FAULT.;[02] VERIFIED PANEL 194CL OUTER SKIN HAS BEEN REPAIRED IASDR SWAA2024031452669Web · corrodedCORROSION ON 1016 WEB AT AFT WET AREA BS1016+13 LBL7 WL208. MARKED<[01] REMOVED CORROSION ON 1016 WEB AT AFT WET AREA BS 1016+13 LBL 7; WL 208 AND REWORKED PER EA 24-153-00486.;[02] TASK CARD COMPLETESDR SWAA2024031452670Strap · corrodedCORROSION ON TENSION STRAP AT AFT WET AREA BS1016; BS1016+11; RBL3 WL208. MARKED<[01] CORROSION ON TENSION STRAP AT AFT WET AREA BS 1016+11 RBL 3 WL 208 FOUND TO BE OUT OF LIMITS. REMOVED AND REPLACED AFT WET AREA TENSION STRAP IAW SRM 51-40-02-0G-0 AND DWG 14SDR SWAA2024031452815Angle · crackedRIGHT WING FIXED T/E PANEL JUST AFT OF THE PYLON ATTACH ANGLE CRACKED JUST IB OF DEFLECTION RIB. MARKED<[01] REMOVED AND REPLACED RIGHT WING FIXED T/E ATTACH ANGLE JUST AFT OF PYLON AND I/B OF DEFLECTION RIB IAW SRM 51 -40-02-0G-0 PARA. 4.;[02] VERIFIED COMPLESDR SWAA2024031252665Floorbeam · corrodedCORROSION ON FLOOR BEAM AT AFT WET AREA BS986 RBL43 WL208. MARKED<[01] CORROSION ON BS 986 FLOOR BEAM AT RBL 43; WL 208 FOUND TO BE OUT OF LIMITS PER SRM 53-70-51-1A-1. REPAIRED FLOOR BEAM PER SRM 53-70-51-2R-6.;[02] CORRECTED MEASUREMENT;[03] CUSTOMER CARD COSDR SWAA2024031252666Floorbeam · corrodedCORROSION ON FLOOR BEAM AT AFT WET AREA BS986 LBL43 WL208. MARKED<[01] COMPLETED STEP 8; PARTIAL STEP 9.;[02] COMPLETED STEP 9.;[03] VERIFIED STEPS 11;13 COMPLETE.;[04] REMOVED CORROSION FROM AFT WET AREA FLOOR BEAM BS 986 LBL 43 WL 208 FOUND TO BE OUT OF LIMISDR SWAA2024031252671Skin · crackedDURING HFEC INSPECTION OF LH HORIZONTAL STABILIZER LOWER SKIN (TTG8Q00BDWA5); CRACK FOUND AT STA:193.90; 18' FROM FWD EDGE; MEASURED L: 1.0' MARKED<[01] REPAIRED LH HORIZONTAL STABILIZER LOWER INSPAR SKIN AT STA 193.90 18' FROM FWD EDGE IAW SRM 55-10-01-2R-11;
Back to Boeing 737-7H4