Boeing 737-7H4
Service difficulty reports · 96,125
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7377H4' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7377H4' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2026033076731Sidewall Support · corrodedAFT CARGO SIDEWALL SUPPORT AT RBL 22, BS 727 - 767 CORRODED AT SEVERAL LOCATIONS. REMOVED AND REPLACED THE SIDEWALL SUPPORT IAW SRM 51-40-02-0G-0, & DWG 146A7500, REV -.SDR SWAA2026033076732Sidewall Support · corrodedAFT CARGO SIDEWALL SUPPORT AT BS 727A, LBL 22, WL 155 CORRODED. SIDEWALL SUPPORT RESOLVED ON CUSTOMER CARD TTG8Q01ASTYM.SDR SWAA2026033076808Pressure Blkhd · crackedAFT PRESSURE BULKHEAD HAD A CRACK INDICATION, EMANATING FROM RIVET AT STRINGER 7R LOWER GROUP OF FIVE, CLOSEST TO APEX. APPROX. 1/8' LONG. REJECTED STEP 43 FOR EDGE MARGIN IS OUT OF LIMITS OF -1 FILLER AND -2 FILLER. REFABRICATED -1 AND -2 REPAIR PARTS TO MSDR SWAA2026032076727Support · corrodedFWD CARGO COMPARTMENT FLOOR TO BULKHEAD SUPPORT CORRODED, BS 500D, LBL22 - RBL 22, WL 156. REMOVED AND REPLACED THE FLOOR TO BULKHEAD SUPPORT IAW SRM 51-40-02-0G, AND DRAWING 143A9481, REV -.SDR SWAA2026032076725Sidewall Support · corrodedFWD CARGO BAY FLOOR TO SIDEWALL SUPPORT CORRODED, BS 500A+6, 500A+10, 500A+14, & 500A+18, RBL 25, WL 156. REMOVED AND REPLACED THE SIDEWALL SUPPORT IAW SRM 51-40-02-0G, AND DRAWING 143A7500, REV -.SDR SWAA2026032076726Sidewall Support · corrodedCORROSION ON FWD CARGO COMPARTMENT FLOOR TO SIDEWALL SUPPORT BS 400-500D; LBL22; WL 156. REMOVED AND REPLACED FWD. CARGO FLOOR TO SIDEWALL SUPPORT IAW SRM 51-40-02-0G AND DRAWING 143A7500 REV -.SDR SWAA2026030976578Scuff Plate · crackedCRACK MEASURING 0.5 IN. ON DENT MEASURING L=0.625; W=0.5; D=0.054, ON THE FWD CARGO SCUFF PLATE. R & R THE SCUFF PLATE IAW AMM 53-11-01, & 53-11-02,SDR SWAA2026033176435Stringer · crackedCRACKED STRINGER 25R, BS 535, WL155. REPAIRED IAW EA 26-153-00644. THIS IS A CATEGORY A REPAIR AS DEFINED IN SRM 51-00-06.SDR SWAA2026033176027Floor Panel · pulledFLOOR PANEL 232RF UPPER SKIN HAS AREAS OF PULLED STRANDS. FLOOR PANEL 232RF WITH UPPER SKIN AREAS OF PULLED STRANDS WAS REPLACED WITH A NEWLY FABRICATED FLOOR PANEL IAW SRM 53-00-50-2R-0, AND DWG 144A5810, 0151, DUE TO AMOUNT OF ALL DAMAGE.SDR SWAA2026033176029Floor Panel · pulledFLOOR PANEL 241AF UPPER SKIN HAS AREAS OF PULLED STRANDS. FLOOR PANEL 241AF WITH UPPER SKIN AREAS OF PULLED STRANDS WAS REPLACED WITH A NEWLY FABRICATED FLOOR PANEL IAW SRM 53-00-50-2R-0 AND DWG: 144A5810, 0127.SDR SWAA2026033176028Floor Panel · pulledFLOOR PANEL 232SF UPPER SKIN HAS AREAS OF PULLED STRANDS. THE FLOOR PANEL WAS REPLACED WITH A NEWLY FABRICATED FLOOR PANEL IAW SRM 53-00-50-2R-0, & DRAWING 144A5810, SHEET 161.SDR SWAA2026033076436Stringer · crackedCRACKED STRINGER 26R, BS 535, WL153. REPAIRED STRINGER 26R BTWN BS 500D & 540, AND APPLIED A FILLET SEAL & CIC IAW SRM 53-00-03-2R-1, REPAIR 1.SDR SWAA2026033076437Stringer · crackedCRACKED STRINGER 23 LT, BS 535, WL164. REPAIRED STRINGER 23L BTWN BS 500D & 540, WL 164. APPLIED A FILLET SEAL AND CIC IAW SRM 53-00-03-2R-1, REPAIR 1.SDR SWAA2026033076020Floor Panel · pulledFLOOR PANEL 231XF UPPER SKIN HAS MULTIPLE AREAS OF PULLED STRANDS. FLOOR PANEL 231XF WAS REPLACED WITH A NEWLY FABRICATED FLOOR PANEL IAW SRM 53-00-50-2R-0, & DWG 144A5810, 0126.SDR SWAA2026033076026Floor Panel · debondedFLOOR PANEL 231ZF LOWER SKIN IS DEBONDED NEAR AFT EDGE. FLOOR PANEL 231ZF WAS REPLACED WITH A NEWLY FABRICATED FLOOR PANEL IAW SRM 53-00-50-2R-0, & DWG 144A5810, SHEET 160.SDR SWAA2026033076021Floor Panel · debondedFLOOR PANEL 241BF UPPER SKIN IS DEBONDED NEAR CENTER OF PANEL. FABRICATION OF A NEW FLOOR PANEL REPLACEMENT HAD BEEN ACCOMPLISHED IAW SRM 53-00-50-2R-0.SDR SWAA2026033076030Floor Panel · pulledFLOOR PANEL 241DF UPPER SKIN HAD AREAS OF PULLED STRANDS. FLOOR PANEL 241DF WAS REPLACED WITH A NEWLY FABRICATED FLOOR PANEL IAW SRM 53-00-50-2R-0, AND DWG 144A5810, 0128.SDR SWAA2026033076022Floor Panel · pulledFLOOR PANEL 241EF UPPER SKIN HAS AREAS OF PULLED STRANDS. FABRICATED A NEW FLOOR PANEL 241EF & REPLACED IAW SRM 53-00-50-2R-0.SDR SWAA2026033076023Floor Panel · pulledFLOOR PANEL 242AF UPPER SKIN HAD AREAS OF PULLED STRANDS. FLOOR PANEL 242AF WAS REPLACED WITH A NEWLY FABRICATED FLOOR PANEL IAW SRM 53-00-50-2R-0 AND DWG 144A5810, SHEET 189.SDR SWAA2026033076031Floor Panel · pulledFLOOR PANEL 242BF UPPER SKIN HAD AREAS OF PULLED STRANDS. FLOOR PANEL 242BF WAS REPLACED IAW SRM 53-00-50-2R-0, & DWG 144A5810, SHEET 122. ;[02] ITEM 1SDR SWAA2026033076025Floor Panel · pulledFLOOR PANEL 242DF UPPER SKIN HAD AREAS OF PULLED STRANDS. FLOOR PANEL 242DF WAS REPLACED WITH A NEWLY FABRICATED FLOOR PANEL IAW SRM 53-00-50-2R-0, & DWG 144A5810, SHEET 150.SDR SWAA2026033075818Pressure Blkhd · crackedAFT PRESSURE BULKHEAD HAD A CRACK INDICATION EMANATING FROM RIVET AT STRINGER 7R LOWER GROUP OF FIVE CLOSEST TO APEX. APPROX. 1/8' LONG. IAW PART 6, 51-00-00, PROCEDURE 23.SDR SWAA2026032376434Web · corrodedCORRODED RT DOOR SUB THRESHOLD WEB, BS 767 - 787, RBL 27, WL 154. REMOVED AND REPLACED THE SUB-THRESHOLD WEB IAW SRM 51-40-02-0G-0-A00729.SDR SWAA2026032075976Floor Panel · pulledFLOOR PANEL 231JF UPPER SKIN HAS AREAS OF PULLED STRANDS. THE FLOOR PANEL 231JF WAS REPLACED WITH A NEWLY FABRICATED FLOOR PANEL IAW SRM 53-00-50-2R-0 & DRAWING 146A5810, SHEET 577.SDR SWAA2026032075978Floor Panel · pulledAFT FLOOR PANEL 241ZF UPPER SKIN HAS AREAS OF PULLED STRANDS. AFT FLOOR PANEL 241ZF WAS REPAIRED IAW SRM 53-00-50-2R-1.SDR SWAA2026032075980Floor Panel · pulledAFT FLOOR PANEL 242VF UPPER SKIN HAS AREAS OF PULLED STRANDS. AFT FLOOR PANEL 242VF WAS REPAIRED IAW SRM 53-00-50-2R-1.SDR SWAA2026032075977Floor Panel · pulledFLOOR PANEL 232FF UPPER SKIN HAS AREAS OF PULLED STRANDS. FABRICATION OF NEW 232FF FLOOR PANEL REPLACEMENT HAS BEEN ACCOMPLISHED IAW SRM 53-00-50-2R-0.SDR SWAA2026032075983Floor Panel · pulledAFT FLOOR PANEL 241ACF UPPER SKIN HAS AREAS OF PULLED STRANDS. AFT FLOOR PANEL 241ACF WITH UPPER SKIN AREAS OF PULLED STRANDS WAS REPAIRED PER SRM 53-00-50-2R-1.SDR SWAA2026032076431Sidewall Support · corrodedCORROSION ON L/H FLOOR TO SIDEWALL SUPPORT STA 727+4-847; LBL 22; WL 156 AT VARIOUS SPOTS. IN AFT CARGO COMPARTMENT. REMOVED AND REPLACED L/H FLOOR TO SIDEWALL SUPPORT (ZEE ANGLE) AT STA 727+4-847; LBL 22; WL 156. PER SRM 51-40-02-0G .SDR SWAA2026032076432Sidewall Support · corrodedCORROSION ON RT FLOOR TO SIDEWALL SUPPORT BS 727+4 - 767, RBL 22, WL 156 AT VARIOUS SPOTS. AFT CARGO COMPARTMENT. REMOVED AND INSTALLED A NEW RT FLOOR TO SIDEWALL SUPPORT BS 727+4 -767, RBL 22, WL 156 IAW SRM 51-40-02-0G-0.SDR SWAA2026032076433Shield · corrodedCORROSION ON R/H FLOOR TO SHIELD STA 767-787; RBL 22; WL 155 AT VARIOUS SPOTS. IN AFT CARGO COMPARTMENT. REMOVED AND REPLACED. INSTALLED NEW SHIELD BS 767-787, RBL 22, WL 155 IAW SRM 51-40-02-0G AND DRAWING 146A0081, REV A.SDR SWAA2026030976539Engine · odorBIRD STRIKE, NO ABNORMAL ENGINE INDICATIONS. ODOR OF HOT OR SOMETHING COOKING IN COCKPIT & CABIN. C/W BIRDSTRIKE CONDITIONAL INSP IAW AMM 05-51-18. REF DEFECT LGPG 3025472. INSPECTED PER AMM 05-51-18-210-801-NG-01.SDR SWAA2026030976238Bulkhead Web · crackedCRACK INDICATION ON STRINGER 7L OF AFT PRESSURE BULKHEAD CENTER WEB.SDR SWAA2026030976248Sign · brokenCEILING EXIT SIGN MID-CABIN BROKEN. R & R CEILING EXIT LIGHT ASSY IAW AMM 33-51-01.SDR SWAA2026030976062Lamp · inoperativeRIGHT EXTERIOR OVER WING EMERGENCY EXIT LIGHT INOPERATIVE. REMOVED & REPLACED THE LAMP IAW AMM 33-51-04-960-801-NG. OPS CHECKED GOOD.SDR SWAA2026030976137Access Panel · damagedACCESS PANEL 194BL HAS ELONGATED FASTENER HOLE. PREPPED AND PAINTED ACCESS PANEL 194BL REF M/M 51-21-99. PANEL READY FOR INSTALLATION. REF TTG8Q01ARDBG FOR PANEL 194BL INSTALLATION.SDR SWAA2026033175992Crossbeam · crackedCRACKED CROSSBEAM, BS 540, LBL 44, WL 208. REMOVED AND REPLACED CROSSBEAM, BS 540, LBL24 - 45, WL 208, IAW SRM 51-40-02, & DWG 143A5240, REV -.SDR SWAA2026033175999Seat Track · corrodedCORROSION ON SEAT TRACK LBL 45, BS 480+17, BS 500+8, BS 500A+8, BS 500B+18. THE SEAT TRACK WILL BE REPLACED ON FAULT TTG8Q01AR96P.SDR SWAA2026033075902Floor Support · crackedCRACKED INTERCOSTAL AT BS 380-400 RBL 8 WL 208. REMOVED AND REPLACED INTERCOSTAL AT BS 380-400 RBL 8 WL 208 IAW SRM 51-40-02-0G-0 AND DWG 143A5400 SHEET 38 REV A.SDR SWAA2026033075893Strap · corrodedCORROSION ON STRAP AT BS 1018 RBL3 WL 208<[01] REMOVED; FABRICATED AND INSTALLED NEW TENSION STRAP BS 1006 - BS11028 RBL3 WL 208 I.A.W SRM 51-40-02-0G-0; SRM 51-40-05-0G-0 AND BOEING DWGS 147A5730 REV: C; 147A5744 REV: B; PL 147A5744 REV: E.SDR SWAA2026033075903Intercostal · crackedCRACKED INTERCOSTAL AT BS 380-400 LBL 13 WL 208. NOT ALLOWABLE LIMITS FOUND THEREFORE SRM 51-10-02-0G-0 PAR 9.C REMOVE AND REPLACEMENT OF THE PART IS APPLICABLE; REMOVED CRACKED INTERCOSTAL AT BS 380-400 LBL 13 WL 208 PER SRM 51-40-02; OK TO INSTALL NEW INTESDR SWAA2026033075904Intercostal · crackedCRACKED INTERCOSTAL AT BS 380-400 BL 0 WL 208. NOT ALLOWABLE LIMITS FOUND THEREFORE SRM 51-10-02-0G-0 PAR 9.C REMOVE AND REPLACEMENT OF THE PART IS APPLICABLE; REMOVED CRACKED INTERCOSTAL AT BS 380-400 BL 0 WL 208 PER SRM 51-40-02; LOCATED AND DRILLED NEW INSDR SWAA2026033075900Intercostal · crackedCRACKED INTERCOSTAL, BS 312 - 328, LBL 45, WL 208. REMOVED & REPLACED THE INTERCOSTAL IAW SRM 51-40-02-0G-0, & DWG 141A5400, SHEET 26, REV-.SDR SWAA2026033075901Intercostal · crackedCRACKED INTERCOSTAL, BS 328 - 344, LBL 45, WL 208. REMOVED & REPLACED THE INTERCOSTAL IAW SRM 51-40-02-0G-0, & DWG 141A5400, SHEET 44, REV -.SDR SWAA2026033075682Scuff Plate · crackedAFT CARGO BAY AFT CORNER SCUFF PLATE CRACKED. REPAIRED THE SCUFF PLATE IAW SRM 53-60-15-2R-1.SDR SWAA2026033075681Scuff Plate · crackedAFT CARGO BAY FWD CORNER SCUFF PLATE CRACKED. AFT CARGO BAY FWD CORNER SCUFF PLATE WAS REPLACED IAW SRM 51-10-02-0G-0, PARAGRAPH 9.SDR SWAA2026033075775Shield · corrodedCORROSION ON ACD FWD SHIELD WEB BETWEEN BS 767 - 794, RBL 23, WL 156, REMOVED & REPLACED THE SHIELD IAW SRM 51-40-02, AND DWG 146A0081, 0034, REV-.SDR SWAA2026033075776Shield · corrodedCORROSION ON ACD AFT SHIELD WEB BETWEEN BS 847 - 867, RBL 23, WL 156. REMOVED & REPLACED THE SHIELD IAW SRM 51-40-02, AND DWG 146A0081, 0034, REV-.SDR SWAA2026033075777Threshold Web · corrodedCORROSION ON ACD SUB THRESHOLD WEB BETWEEN BS 794 - 847, RBL 26, WL 156. REMOVED AND REPLACED THE SUB THRESHOLD WEB IAW SRM 51-10-02-0G-0, PARAGRAPH 9,SDR SWAA2026033075993Threshold Web · corrodedCORROSION ON FCD SUB THRESHOLD WEB BETWEEN BS 440 - 492, RBL 26, WL 156. REMOVED AND REPLACED THE SUB THRESHOLD WEB, IAW SRM 51-40-02-0G-0, & DWG 143A8330, REV A.
Back to Boeing 737-7H4