SDR SCNA20240311146Sidewall Support · corrodedCORROSION AT SIDEWALL SUPPORT FRAME ATTACH ANGLE STA 500D, LBL 27 - LBL 36. REMOVED AND INSTALLED NEW SIDEWALL SUPPORT FRAME ATTACH ANGLE AT BS 500D, LBL 27-LBL36 IAW SRM 51-40-02-0G-0 AND DWG 143A1225.SDR SCNA20240124018Light · inoperativeROW 15 EMERGENCY EXIT DOOR OVERHEAD LIGHT INOP. R+R ROW 15 ABC LIGHT REF AMM 33-21-51 THIS CLEARS MEL 33-2-2 MDDR#122343.SDR SCNA20240124019Light · missingDEFECT 755212: - - EMERGENCY EXIT OVERWING LIGTH (PLACARD) MISSING. - - RESOLUTION: REPLACED EMERGENCY EXIT OVERWING LIGHT LENSE IAW B737 AMM 33-51-01-960-801SDR SWAA2024012343612Flashlight · inoperativeFWD F/A FLASHLIGHT INOP.<[01] R & R?D FLASHLIGHT PER M/M 25-64-00SDR SWAA2024012242969Battery Pack · inoperativeL/H AFT ENTRY EMERGENCY LIGHT BATTERY PACK INOP<[01] REMOVED AND REPLACED AFT L/H BATTERY PACK FOR EMERGENCY LIGH PER AMM 33-51-06 OPS CHECK GOODSDR SWAA2024012242994Megaphone · failedAFT MEGAPHONE DOES NOT ILLUMINATE DURING TEST<[01] REPLACED BATTERIUES IN AFT MEGAPHONE OPS CHKS GOOD PER AMM 25-64-00SDR SWAA2024012243005Flashlight · failedONE FWD FA FLASHLIGHT WILL NOT TEST.<[01] CND OPS CK NORMAL IAW AMM 25-64-00SDR CALA2024011900152Sensor · faultyLE DEVICES TRANSIT LIGHT STAYS ON SLATS 2 LE FLAPS TRANSIT LT ON LE SLAT 2 LT OVRHD QRH DID NOT FIX AHM DATA SHOWS FAULTS ON LE SLAT 2 AND LE SLAT 4 RETRACT SENSORS. LOCKING. UNLOCKED FOR SIGNOFF. T/S PER WDM 27-81-12-1 , FOUND OPEN BETWEEN S1094 AND PLUG D728SDR SWAA2024011842409Coffeemaker · burnedELECTRICAL SMELL IN AFT GALLEY. TURNED OFF COFFEE POTS AND GALLEY LIGHTS. SMELL WENT AWAY AND DID NOT RETUREN<[01] F/A NOTIFY ELECTRIC SMELL COMING FROM CAPT SIDE C/M AREA. FOUND ELECTRIC WIRE BURN MARKS FROM L/H AFT C/M RAIL ASSY . R/R L/H AFT COFFEE MAKER ANSDR SWAA2024011842369Light · inoperativeFOUND AFT ENTRY DOOR EMERGENCY LIGHT INOP<[01] RELAMPED AFT ENTRY DOOR EMERGENCY LIGHT PER AMM 33-51-04.OPS CHECK GOODSDR M17F202402020001Transmitter · false indicationRIGHT FLAP POSITION TRANSMITTER DISAGREE
TE FLAP SNSR R 27-52260SDR SWAA2024012442633Angle · crackedDOT #14 A-43; AFT CARGO VACUUM WASTE COMPARTMENT; LEEK ANGLE CRACKED STA 867 LBL 12 WL 156<[01] REMOVED AND REPLACED AFT CARGO WASTE COMPARTMENT BRACKET 149A8109-114 IAW SRM 51-40-02-0G-0 IPC 53-42-51-06;[02] AUDIT C/WSDR M17F20240122009Transmitter · malfunctionedDURING FINA APPROACH FLAP LEVER IN 30 BUT INDICATION IN 15.SDR SWAA2024011841998Girt Bar · detachedFORWARD ENTRY GIRT BAR CAME OFF HANGER<[01] UNJAMMED GIRT BAR. ALL GOOD. REF AMM 25-66-00SDR 2024F00077Motor · defectiveAFATER TAKEOFF WHEN TRYING TO COMPENSATE WITH MAIN ELECTRIC TRIM, IT IS NOT POSSIBLE, STAB AOUT OF TRIM LIGHT OCCASIONALLY, STABALIZER TRIM INOPERATIVE LIST MADE. CORRECTIVE ACTION TAKEN: STABILIZER TRIM MOTOR WAS REPLACED I.A.W. AMM TASK 27-41-71-000-8SDR SCNA20240311145Angle · crackedINITIAL INSPECTION: CRACK ON SEVERAL ANGLES AT STA 500G STGR 26R, STA 500H STRG 26R AND BTW STA 500G/500I AND STGR 23L / 25L ON FWD CARGO COMPARTMENT. DAMAGED ANGLES AT STA 500G STGR 26R, STA 500H STRG 26R AND BTW STA 500G/500I AND STGR 23L / 25L ON FWD CARGO SDR SWAA2024011941739Inlet · cracked#1 ENGINE INLET COWL HAS A BUBBLE SHAPED DEFECT ON OUTER SIDE WITH CRACKS AT APPROX. 8:00 OCLOCK POSITION.<[01] REF TSR 202400353. REMOVED DAMAGE PER SRM 51-10-02. REMOVED DAMAGE DIMENSIONS .75 X .50.;[02] REMOVED INLET COWL. REF AMM 71-11-01.SDR SWAA2024011641525Slide · failedFWD ENTRY DOOR OPENED WITH GIRT BAR ATTACHED; SLIDE DID NOT DEPLOY<[01] REPACKED FWD ENTRY DOOR SLIDE AT L1 REF AMM 25-66-01 NO FURTHER DEFECTSSDR SWAA2024011641622Flashlight · inoperativeAFT FA EMERGENCY FLASHLIGHT INOP. R & R AFT F/A EMERGENCY FLASHLIGHT ASSY LT INBD IAW AMM 25-64-00.SDR SCNA2024012716014Unknown · smokeSUPPLEMENTAL: DEFECT 765927 - - CORRECTIVE ACTION: DUE TO INSPECTION OF SMOKE IN CABIN PER AMM 05-51-56 AND FIM TASK 21-00 TASK 806 NO FINDINGS FOUND AND VALVE OPERATED NORMALLY THIS CLEARS MEL.SDR SWAA2024011741499Flashlight · brokenF/A FLASH LIGHT AFT AT CAPTAIN SIDE BROKEN<[01] FOUND AFT CA SIDE FA FLASHLIGHT IMPROPERLY SEATED. RE-SEATED FLASHLIGHT AND INSTALLED NEW SEAL. FLASHLIGHT NOW OPS CHECKS GOOD REF: AMM 25-64-00.SDR SWAA2024011641451Flashlight · inoperativeFWD F/A FLASHLIGHT WILL NOT TEST<[01] R/R FWD FA FLASHLIGHT ASSY & PFM OPS CHK IAW AMM 25-64-00 SATIS. THIS CLRS MEL. REF CMM 25-60-13SDR SCNA20240116014Unknown · odorDEFECT 765927: - - FLT ATTENDANTS REPORT BURN RUBBER SMELL THROUGHOUT THE CABIN. - - RESOLUTION: (IN PROGRESSSDR SWAA2024011640876Battery · failedFLIGHT DECK FLASHLIGHT PUSH TO TEST LED FAILS TO ILLUMINATE.<[01] REMOVED AND REPLACED FLASHLIGHT BATT PER AMM 25-64-00SDR SWAA2024011640922Lens · missingEXIT SIGN COVER AT OVERWING MISSING ; RT. SIDE.<[01] INSTALLED LENS PER AMM 33-51-01.SDR 2024F00074Gasket · leakingFUEL LEAK DETECTED ON RIGHT WING DURING WALKAROUND CORRECTIVE ACTION TAKEN: THE ALUMINUM GASKET WAS REPLACED IAW 28-11-11-400-801SDR SCNA20240130024Outflow Valve · icedDEFECT 723152: - - EXPERIENCED PRESSURE FLUCTUATIONS IN FLIGHT AND EVENTUALLY LOST PRESSURIZATION. RAN CHECKLIST AND WAS UNABLE TO CLOSE OUTFLOW VALVE MORE THAN 40% CLOSED. - - RESOLUTION: FOUND ICE ON OUTFLOW VALVE. REMOVED ICE AS REQUIRED. PERFORMED BITE ONSDR CALA2024011500118Sensor · looseFWD ENTRY DOOR LIGHT ILLUMINATED ON TAKEOFF REJECT INITIATED AT 110 KTS AS PER INBOUND CREW GROSS WEIGHT 170.800 LBS. BRAKES ON SPEED 110KNOTS. PRESSURE ALT 200FT. OAT 44C. RTO SELECTED FOR STOPPING A/C. THRUST REVERSERS WERE USED. TAXI FROM A/C STOP TO GATE ASDR 2024FA0000226Fuel Tank · leakingFUEL LEAK DROP CENTER TANK CORRECTIVE ACTION TAKEN: 1.- ACCES DOOR 631AB OF RH WING WAS INSTALED AIW AMM 28-11-31 2.- ACCES DOOR 531BB OF LH WING WAS INSTALLED AIW AMM 28-11-21SDR SWAA2024011239955Battery · dischargedFLIGHT DECK EMERGENCY FLASHLIGHT BATTERY LOW<[01] R&R EMERGENCY FLASHLIGHT BATTERY PER CMM 25-60-13SDR SWAA2024011239748Battery · inoperativeCOCKPIT EMERGENCY FLASHLIGHT HOLDER WILL NOT TEST COCKPIT EMERGENCY FLASHLIGHT HOLDER WILL NOT TEST.<[01] OK TO CONTINUE PER MEL 25-64-02 SP1B.;[02] REMOVED AND REPLACED COCKPIT FLASHLIGHT BATTERY IAW AMM CHPT 25-64-00 THIS CLEARS MEL 25-64-02ASDR SWAA2024011139620Light · inoperativeAFT ENTRY DOOR EMERGENCY SLIDE LIGHT INOP<[01] REMOVED AND REPLACED AFT ENTRY DOOR EMERGENCY SLIDE LIGHT LAMP PER AMM 33-51-04SDR SWAA2024011639353Floor Panel · crackedAFT CARGO FLOOR PANEL 140CF HAS CRACK AND DENT<[01] INSTALLED PANEL 140CF IAW AMM 50-10-04-400-801;[02] C/W<BR>AUDIT C/WSDR CALA2024011200089Unknown · unknownSTAB OUT OF TRIM DISCONNECTED AP+AT ELEC TRIM OPS NORMAL PERFOMED DFCS FAULT REVIEW, FOUND MESSAGE 22-11830 ON FLT LEG 01, SUSPECT CREW OPERATION. PERFORMED DFCS LIBRARY TEST 60.32 AND 60.35 IAW FIM TASK 22-11 TASK D72, NO FAULTS FOUND ALL TESTS PASSED. NO RELSDR SWAA2024011139316Megaphone · intermittentF A REPORTS AFT MEGAPHONE INTERMITTENT<[01] R&R MEGAPHONE IAW AMM 25-64-00SDR SWAA2024011139270Battery Pack · inoperativeLH MID CABIN EMERGENCY LIGHTS IN COVE PANELS FWD OF EMERGENCY DOORS INOP<[01] R/R?D M2335 EMERGENCY LIGHT POWER SUPPLY BATTERY PACK REF AMM 33-51-06. OPS CHECK NORMAL.SDR SWAA2024011138981Flashlight · inoperativeFWD FA FLASHLIGHT INOP.<[01] OK TO CONTINUE PER MEL: 25-64-02A SP#1. AUTHORIZATION# 174470.;[02] REPLACED FWD FA FLASHLIGHT BATTERY PER AMM 25-64-00. THIS CLEARS MEL.SDR SCNA20240108005Unknown · unknownDEFECT 731540 - - #2 ENG HYD PUMP LOW PRESS IN CRZ. B SYS QTY SHOWS 0 AND PRESSURE SHOWS >2900 PSI. #2 ENG HYD PUMP SWITCHED OFF PER QRH. - - RESOLUTION: (IN RPOGRESS)SDR SWAA2024010939013Battery Pack · inoperativeRH EXTERIOR SLIDE EMERGENCY LIGHT INOP.<[01] REMOVED AND REPLACED EMERGENCY LIGHT BATTERY PACK M2816 IN REF TO AMM 33-51-06. OPS TEST GOOD. NO DEFECTS NOTED AT THIS TIME.SDR SWAA2024011038849Battery · inoperativeFWD GALLEY FLASHLIGHT INOP<[01] R&R FWD GALLEY I/B FLASHLIGHT BATTERY PER AMM 25-64-00. THIS CLEARS MEL 25-64-02A. MOC NOTIFIED. REF SA-M 663ETOPS LOGPAGE 0442822E AND MXI TTG8Q00QRTXU.SDR SWAA2024010939005Unknown · smokeTAXING TO GATE W/ BOTH ENGINES RUNNING AND APU AS WELL. NO CONFIGURATION CHANGE CHANGES SMELLED ACRID / ELECTRICAL BURNING SMELL W/ NO SMOKW PRESENT.<[01] COMPLIED WITH CONDITIONAL INSPECTION PER AMM 05-51-56. NO ISSUES NOTED.SDR CALA2024010800048Anti-Ice Valve · failedENG ANTI-ICE COWL VALVE LIGHT IS ON AT MORE THAN 28000 FEET ENG 2 COWL VALVE LIGHT REMAINS ILLUMINATED WHEN SWITCHED TO ON AT FL300 T/S PER FIM 30-21 TASK 810 FOUND #2 ENG ANTI ICE VALVE FAILED, REMOVED AND REPLACE VALVE REF AMM 30-21-11-000-801 AND 30-21-11-4SDR SWAA2024010437671Lamp · inoperativeEMERGENCY LIGHT BETWEEN LH EMERGENCY EXITS DOORS INOP<[01] RELAMPED EMERGENCY LIGHT BETWEEN LH EMERGENCY EXITS REFERENCE B737AMM CH 33-51-04. OPS CK GOOD.SDR SWAA2024010837691Engine · stalledNR 2 ENGINE COMPRESSOR STALL ON DEPARTURE. QRC AND QRH COMPLETED. STALLED TWICE. R & R NR 2 ENG ON WP BC TTG8Q00QP4PM. ORIGINAL SUBMISSION DATE: 1/8/2024.SDR SWAA2024010437690Girt Bar · out of adjustFWD GALLEY SERVICE DOOR SLIDE GIRT BAR DIFFICULT TO LATCH IN DISARM.<[01] REMOVED FWD SERVICE DOOR SLIDE AND REPACKED AND ADJUSTED PER MT 825-PRD-01-01.SDR SWAA2024010437461Handle · out of adjustAFT ENTRY DOOR HANDLE IS DIFFICULT TO OPEN AND CLOSE<[01] ADDED TOOLING;[02] ACCOMPLISHED AFT ENTRY DOOR SYSTEM TEST PER AMM 52-13-00-700-801 WITH NO FAULTS NOTED. ACCOMPLISHED AFT ENTRY DOOR LUBRICATION PER AMM 12-25-12. DOOR OPERATES AS REQUIRED AT THIS TIMESDR SCNA20240103003Unknown · unknownDEFECT 717600: L1 ESCAPE SLIDE PACK BUSTLE LOOSE. - - - RESOLUTION: INSTALLED GIRT BAR INTO RETAINING CLIPS REF AMM 25-66-01. READY FOR SERVICE.SDR SCNA20240103002Unknown · unknownDEFECT 746372: R2 DOOR GIRT BAR DIFFICULT TO REMOVE. - - RESOLUTION: REMOVED DEBRIS FROM GIRT BAR LATCH REF AMM 25-66-02. OPS CHK GOOD.SDR SCNA20240103001Unknown · unknownDEFECT WORK ORDER 83401: L1 DOOR GIRT BAR CLIP LOOSE. - - RESOLUTION: REMOVED L1 DOOR SLIDE REPLACED BROKEN RIVET IN GIRT BAR CLIP INSTALLED DOOR SLIDE ON L1 DOOR REF AMM 25-66-01.SDR SWAA2024010236719Mount · missingFWD GALLEY #7 DOOR 7-12/7-09 SLIDE MISSING MOUNT. REF L/P 2262727.<[01] OK TO CONTINUE PER MEL 25-28-01A. SP#1B APPLIED. AUTH # 173198;[02] INSTALLED SLIDE MOUNT IAW CMM 25-31-71.