SDR CALA2012110600754Skin · dentedAFTER PERFORMING BIRD STRIKE INSPECTION DISCOVERED DENT ABOVE CAPTS L1 WINSHIELD. DAMAGE REPAIRED IAW ECRA 5331-01473.SDR CALA2012103100692Skin · gougedGOUGE AFT OF AFT CARGO DOOR , MID SECTION APPROX. 3.25 INCHES FROM EDGE BLENDED OUT DAMAGE. FOUND TO BE OUT OF LIMITS IAW SRM 53-00-01. REPAIRED AREA IAW SRM 53-00-01, REPAIR 22.SDR CALA2012110900791Skin · gougedPAINT PEELED OFF AT APPROXIMATELY LOCATION FUSE STA 500H APPROXIMATELY FOUR INCHES ABOVE S6R AND FOUND GOUGED APRPROX ONE INCH. INSTALLED REPAIR IAW SRM 53-00-01, REPAIR 3. OK FOR SERVICE.SDR CALA2012110900790Frame · damagedFRAME HAS TWO MISDRILLED HOLES AT 727D STR 2R AND 3R. REPAIRED IAW ECRA 5310-05529.SDR CALA2012110700759Pressure Blkhd · canningOIL CANNING FOUND ON AFT SIDE OF AFT PRESSURE BULKHEAD WEB BETWEEN SL7 AND BL 0. REPAIRED IAW ECRA 5310-04639 REV .SDR CALA2012103100688Skin · dentedLEFT HORIZONTAL STAB DENTED AT L/E STA 216 IS OUT OF LIMITS IAW SRM 55-10-01, ALLOWABLE DAMAGE 1, PG 105, STEP (2) GENERAL CONDITION. REPAIRED LT HORIZONTAL L/E AT STA 216 REF SRM 55-10-01, REPAIR 1.SDR CALA2012101800680Sign · looseEXIT SIGN OVERHEAD FIRST CLASS CABIN LOOSE. REPLACED EXIT SIGN IN FIRST CLASS. VERIFIED OPERATIONS OF EMERGENCY EXIT SIGN.SDR CALA2012101700673Air Data Module · malfunctionedIAS DISAGREE DISPLAYED ON CAPT AND F/O SCREENS - F/O AIRSPEED DEE MED OK. CAPTS INOP. CORRECTED ON LANDING. CAPT'S IAS WENT TO 45 IN DECENT ALT WAS 600'' HIGH PITOT PROBE INSP CK OK IAW AMM 34-11-01-200-804 STATIC PORT IN SPN CHK OK IAW AMM34-11-02-200-803 PSDR CALA2012101700672Frame · crackedFRAME BS 500A FOUND CRACK BETWEEN STR 8 AND 9. REPAIRED FRAME IAW AE 5310-04716.SDR CALA2012101700670Frame · crackedFRAME BS 440, FOUND CRACK BETWEEN STRINGER 8 AND 9. REPAIRED IAW EA 5310-04716, REV C, OP1.SDR CALA2012101700669Frame · crackedBS 500C FRAME HAS A CRACK INDICATION. REPAIRED IAW EA 5310-04716, REV C, OP 1.SDR CALA2012101700668Frame · crackedFRAME BS 380 FOUND CRACKED BETWEEN STR 8 AND 9. REPAIRED IAW EA 5310-04716-REV C, PO 1.SDR CALA2012101700667Frame · crackedBS 440, FRAME HAS A CRACK INDICATION. REPAIRED FRAME IAW EA 5310-04716, REV C, OP1.SDR CALA2012101700665Floorbeam · corrodedFLOORBEAM HAS CORROSION AT BS 294 RBL 40. REPAIR FLOORBEAM IAW EC/RA 5321-01813.SDR CALA2012100900663Frame · crackedLEFT FRAME BS 480 HAS A CRACK INDICATION INBD FASTENER SIDE. REPAIRED IAW EA 5310-04716, REV C.SDR CALA2012100900662Frame · crackedRT FRAME BS 400 HAS A CRACK INDICATION AT INBD FASTENER. INSTALLED FRAME REPAIRED IAW EA 5310-04716.SDR CALA2012100900661Structure · corrodedLEFT STRUCTURE HAS CORROSION. R *& R L2 STRUCTUREREF SRM 51-40-02 AND DWG 147A8501.SDR CALA2012100800659Frame · crackedRIGHT FRAME, BS 480, SHOWS A CRACK INDICATION, INBD FASTENER. REPAIRED FRAME IAW EA 5310-04716.SDR CALA2012100800658Frame · crackedRIGHT FRAME BS 440 HAS A CRACK INDICATION AT INBD FASTENER, REPAIRED FRAME IAW EA 5310-04716.SDR CALA2012100800657Frame · crackedLEFT FRAME BS 400 HAS A CRACK INDICATION, INBD FASTENER SIDE. REPAIRED FRAME IAW EA 5310-04716.SDR CALA2012100800656Frame · crackedLEFT FRAME, BS 440 HAS A CRACK, HFEC OTBD FASTENER SIDE. REPAIRED LT FRAME AT BS 440 IAW EA 5310-04716, REV C, FIG 3.SDR CALA2012100800654Frame · crackedLEFT FRAME, BS 867 SHOWS A CRACK INBD FASTENER. CUT OUT DAMAGED AREA IAW EA 5310-04716, FABRICATED REPAIR ANGLES IAW EA5310-04716 TREAT & PRIMED & INSTALLED IAW EA 5310-0 4716, REV C & SRM 51-40-02.SDR CALA2012100800653Frame · crackedFRAME BS 727F SHOWS A CRACK MFEC INBD FASTENER. REPAIR LT FRAME BS 727F, REF EA 5310-04716, REV C.SDR CALA2012100800652Frame · crackedRT FRAME BS 867 SHOWS A CRACK MFEC INBD FASTENER, REPAIRED CRACKED FRAME AT BS 867 RT SIDE IAW EA 5310-04716, REV C, OP 1.SDR CALA2012100400636Skin · crackedLEFT HORIZONTAL STAB LOWER SKIN AREA ANOMALY FOUND AT STA 147.90 AND 17 " FROM REAR SPAR ANOMALY MEASURES .750" LONG SKIN CRACK AT STA 147.90 LT STAB LOWER SKIN REPAIRED IAW SRM T/R 55-15 / 55-10-01 AND ECRA 5510-02160 REPAIR TO BE INSP AT 56000 FLT CYC'S AFTESDR CALA2012092600627Charger · inoperativeEMERGENCY LIGHTS ON SEATS 8 THRU 12 INOPERATIVE. FOUND FAULTY BATTERY CHARGER AT POSITION M1676. R & R BATTERY CHARGER REF MM 33-51-06. OPS CHECKED NORMAL.SDR CALA2012092500626Stringer · corrodedFWD CARGO BAY 13, STRINGER 28L HAS CORROSION. REMOVED DAMAGE AND REPAIR AREA IAW ECRA 5310-05594 AND SRM 53-00-03.SDR CALA2012092500625Stringer · corrodedFWD CARGO BAY STRINGER 27L HAS CORROSION. REMOVED DAMAGE AND REPAIRED AREA IAW ECRA 5310-05594 AND SRM 53-00-03.SDR CALA2012092100622Shaft · shearedLEFT BLEED TRIP OFF LIGHT ILLUMINATED. QRH FOLLOWED FOUND PRECOOLER VALVE SHAFT SHEARED. REPLACED SAME IAW AMM 36-12- 02. OPS CK NORMAL ROTABLE PARTS CHANGE WAS INDICATED -VALVE, PRECOOLER.SDR CALA2012092000619Seal · contaminatedEXTREMELY LOUD HIGH PITCH NOISE IN VICINITY OF L2, L4 & L5 BETWEEN 2.4 -4.0 CABIN DIF PRESSURE CHECKED & INSPECTED BOTH NR 2 WINDOW, FOUND PRESSURE SEALS CONTAMINATED WITH DIRT & DUST PARTICALS ON LOWER EDGE. CLEANED SEALS & MATING SURFACE ON AIRFRAME. PRESSURSDR CALA2012091700606Fan · inoperativeCABIN CREW REPORTED VISABLE SMOKE AND STRONG BURNING ODOR IN CABIN, STRONGEST AROUND ROWS 7-10. SMELL SPRED FROM AFT GALLEY TO COCKPIT DISSAPATED AFTER COMPLETION OF QRH (C9001 USED DUE TO EMPLOYEE NR 80553 NOT RECOGNIZED FOR ENTRY) INSPECTED ACFT IAW AMM 05-SDR CALA2012091700605Actuator · failedWHILE PERFORMING MANUAL REVERSION TEST LT ELEVATOR TRIM TAB ACTUATOR FAILED. R & R LT ELEVATOR TAB LOCK ACTUATOR IAW AMM 27-51-34-000-804 AND 400-804. NR 4563497 FOR LEAK AND OPS CKS.SDR CALA2012091100599Oxygen Gen · dischargedDURING PAX O2 SYSTEM INSPECTION, FOUND O2 CANISTER AT ROW 34 A, B, C DISCHARGED. REPLACED OXYGEN GENERATOR AT SEAT 34 A, B, C IAW AMM 35-22-11.SDR CALA2012091000585Power Supply · failedDURING SERVICE CHECK, FOUND EMERGENCY LIGHTS IN SEATS FROM ROW 22 AFT ARE INOPERATIVE. FOUND BAD POWER SUPPLY M1672 IN AFT GALLEY OVERHEAD AND REPLACED REF MM 33-51-06. EMERGENCY LIGHTING CHECKED OK.SDR CALA2012090400557Battery Pack · inoperativeEMERGENCY EXIT LIGHT BS 322, WL 291, RLB 7, BATTERY PACK M1674 WILL NOT HOLD A CHARGE, R & R BATTERY PACK, EMERGENCY LIGHT OPS CHECKED GOOD IAW 33-51-06.SDR CALA2012090400559Battery Pack · inoperativeEMERGENCY EXIT LIGHT AT BS 565 WL 213 LBL 68 BATTERY PACK M1694 WILL NOT HOLD A CHARGE. R & R BATTERY PACK EMERGENCY EXIT LIGHTING OPS CHECKED GOOD IAW AMM 33-51-06.SDR CALA2012090400558Battery Pack · inoperativeEMERGENCY EXIT LIGHT BS 952, WL 291, LBL 14 BATTERY PACK M1673 WILL NOT HOLD A CHARGE. R & R BATTERY PACK, EMERGENCY LIGHT OPS CHECKED GOOD IAW AMM 33-51-06.SDR CALA2012083100554Engine · warning lightON TAKE OFF ROLL ABOUT 60-70KTS THE NR 2 ENGINE CONTROL AND 6 PACK ENGINE LIGHT CAME ON. REJECTED TAKEOFF AND RETURN TO GATE. PERFORMED BITE IAW FIM 73-06-00 810-801 F00 FOUND FAULT CODE 73 -21672, CHECKED PITOT HEAT OPERATION, CHECKED NORMAL, CDS FAULT CKSSDR CALA2012082900552Electronic Unit · failedAT 39000 FT DISPLAY SOURCE LIGHT CAME ON. LOST HYD SYS A INDICATION, CAPTAIN`S SPEED LIM IND-LOSS OF SPEED BANDS-WX RANGE DISAGREE.1.5 MIN, FOLLOWED BY DISPLAY SOURCE CHECKLIST. LOST F/D AT 1000FT ON APPROACH. CDS FAULT ON GROUND. NO CB OUT. R & R /31 DEU SDR CALA2012082800541Battery · inoperativeEMERGENCY EXIT LIGHT ROW 15-21 CAME ON AT GATE AFTER ENGINE SHUTDOWN. BATTERIES INOPRATIVE. REPLACED BATTERIES ALSO REPLACED PSU AT M1675 & M1694. GROUND SYS TESTED OK. ACFT BACK TO SERVICE.SDR CALA2012081500506Wire Harness · damagedON PUSH BACK AND START ENG NR 2 OVERHEAT LIGHT ILLUMINATED AND WENT OUT. AFTER TEST, ALL CHECKED GOOD AND CONTINUED AFTER TAKEOFF. 8000FT LIGHT ILLUMINATED, RAN QRH LIGHT WENT OUT. RETURNED TO DEPARTURE, INSPECTED NR 2 ENG FOR PNEUMATIC LEAKS, NONE FOUND, CSDR CALA2012080800499Oven · contaminatedON TAXI OUT, F/A COMPLAINED OF MIST IN AFT CABIN, ODOR OF SULFER, AND THROAT IRRITATION. ACCOMPLISHED FIM TASK 05-51-26-0800-801C. FOUND ODOR EMINATING FROM AFT OVENS. REMOVED FOOD SCRAPS FROM SAME. NO ODOR NOTED ON ENGINE RUN. O/B CREW SUPPLIED WITH FORSDR CALA2012080600496Light · inoperativeFIRE DETECTION WARNING LIGHTS OVHT/DECT AND MASTER CAUTION DO NOT ILLUMINATE DURING FIRE TEST. REMOVED & REPLACED CAPTAINS SIX PACK LIGHT. PERFORMED FIRE DECTECTION TEST OVHT/DECT AND MASTER CAUTION LIGHT ILLUMINATES. OPS CHECK GOOD ACFT OK TO CONTINUE.SDR CALA2012080300494Oxygen Mask · unwanted deployDURING TAKEOFF ROLL, OXYGEN MASK FELL AT SEATS 24DEF. INSPECTED AND PACKED PAX OXYGEN MASKS AT ROW 24DEF, REF MM 35-22-31.SDR CALA2012073000477Skin · crackedLT HORIZONTAL STAB LOWER SKIN IS CRACKED AT INBD FLANGE OF STA 129. 5, RIB 18" AFT OF FWD SPAR. CRACK IS APPROX 2.5" LONG CUT OUT DAMAGE AND INSTALLED REPAIR PARTS REF SRM 55-10-01, REPAIR 11SDR CALA2012073000476Uplock Switch · looseNOSE GEAR LIGHT ILLUMINATED RED AFTER TAKEOFF. AFTER LANDING PSEU LIGHT ILLUMINATED WITH GEAR HANDLE IN UP POSITION. TROUBLESHOOT AND FOUND LOOSE LOCK INDICATION SWITCH AT NOSE GEAR, SECURED AND PSEU RESET, LATCH FAULT CLEARED AND PSEU LIGHT EXTINGUISHED. AMSDR CALA2012072600475Accumulator · faultyDURING CRUISE, BRAKE PRESSURE DROPPED FROM 3000 - 2500 PSI. REMOVED HYD BRAKE ACCUMULATOR IAW AMM TASK 32-41-51-420-801, LEAK CHECKED GOOD, OK FOR SERVICE.SDR CALA2012071600450Controller · malfunctionedLEFT PACK TRIP AND WOULD NOT RESET. CHECK PRIMARY AND SECONDARY HEAT EXCHANGER FOR DEBRIS, CK INLET DOORS AND FOUND GOOD. R & R NR 1 ZONE TEMP CONTROLLER AND BITE CK GOOD IAW AMM 21-61-20. REPLACED ARM AIR ROD SENSOR IAW AMM 21-51-50-000-801. OPS CHECKED GSDR CALA2012070600431Seat Track · corrodedCABIN, CORROSION ON LT OTBD (MIDDLE) SEAT TRACK BETWEEN STA 360 AND 380. INSTALLED REPAIR PARTS ON LT OTBD SEAT TRACK FROM STA 360-410, REF SRM 53-00-52, REPAIR 4.SDR CALA2012070500428Feeder Cable · looseNR 2 ENGINE GENERATOR SOURCE OFF LIGHT INFLT, UNABLE TO BRING NR 2 GENERATOR ONLINE. UNABLE TO START APU INFLIGHT. OPS CHECKED APU REF AMM 49-00-00. OPS CHECKED GOOD. FOUND MAIN FEEDER HARNESS LOOSE AT FIREWALL, ECURED, RAN ENGINE, GENERATOR OPS AND LEAK
Back to Boeing 737-824