SDR ASAA2019091830726Relay · failed#2 FWD FUEL PUMP LOW PRESSURE LIGHT ILLUMINATED WITH PUMP ON. GROUNDED - YES. REF TSR 703841, REMOVED #2 FWD BOOST PUMP GFI RELAY R21 PER AMM 28-22-18-000-801. INSTALLED NEW RELAY R21 PER AMM 28-22-18-400-801. PERFORMED (GFI) RELAY OPERATIONAL TEST PER AMM 28-SDR ASAA2019091830723Spinner · worn#1 ENG FRONT SPINNER CONE BLACK COATING WORN. GROUNDED - YES. REPLACED #1 ENG FRONT SPINNER CONE PER AMM 72-21-01 STEP F (5).SDR ASAA2019091630718Probe · inoperativeON AFTER START FLOW NOTICED "CAPT PITOT" LIGHT ILLUMINATED AFTER TURNING ON PROBE HEAT. GROUNDED - YES. FOUND CAPT PITOT LIGHT ILLUMINATED, PERFORMED FIM TASK 30-31-00-810-802, FOUND CAPT PITOT PROBE INOP, REPLACED CAPT PITOT PROBE REF AMM 34-11-01. PERFORMED SDR ASAA2019091630710Wire Harness · excess playDURING LT - ENGINE HARNESS INSPECTION FOUND J7 HARNESS SLEEVE AT ALTERNATOR OUTBOARD CONNECTOR LOOSE WITH EXCESSIVE PLAY. LEFT HAND ENGINE J7 HARNESS CONSIDERED AN LRU AND SHOULD NOT BE REPAIRED. GROUNDED - YES. REMOVED AND REPLACED J7 HARNESS PER AMM REF 73-2SDR ASAA2019091530717Pump · inoperative#2 TANK FWD BOOST PUMP SHOWED LOW PRESSURE. GROUNDED - YES. REMOVED AND REPLACED #2 FWD FUEL PUMP IAW AMM 28-42-22/401. GROUND VERIFICATION AND LEAK CHECK SUCCESSFUL PER AMM 28-22-41-710-801.SDR ASAA2019091530705Actuator · leaking#2 ENGINE HAS RECENT HISTORY OF FUEL LEAK AT ENGINE START. DUE TO TIME ON VSV ACTUATOR TECH SERVICES REQUESTS REPLACEMENT. GROUNDED - YES. NO ENGINE VENTS AND DRAINS INSPECTION PERFORMED. PERFORMED LEAKS AND DRAINS INSPECTION, FOUND LEFT VBV ON #2 ENG TO BE LESDR ASAA2019091530703Elastomer · tornWHILE ACCOMPLISHING TC 78472010 FOUND THAT ALL THE PLATFORMS RUBBER ON #1 ENG IS RIPPING. GROUNDED - YES. REPLACED ALL PLATFORMS ON #1 ENG REF TC 78472010 FAN BLADE LUBE.SDR ASAA2019091430708Power Supply · inoperativeRIGHT OVERWING EMERGENCY LIGHTS INOP. GROUNDED - YES. REMOVED AND REPLACED LIGHT OVERWING EMERGENCY LIGHT POWER SUPPLY S/N 39707, OPS CHECK GOOD IAW AMM 33-51-06-960-806.SDR ASAA2019091430701Unknown · malfunctionedAPU FAULT LIGHT ON START. GROUNDED - YES. PERFORMED, APU BITE, FOUND FAULT 49-11019 POWER INTERRUPT DUE TO APU SHUTDOWN. NO OTHER FAULTS FOUND. PERFORMED APU START WITH NO FAULTS, SUCCESSFUL GROUND VERIFICATION. REF FIM 49-60 TASK 801.SDR ASAA2019091430693Unknown · malfunctionedCONT CAB ZONE TEMP LIGHT ILLUMINATES-RESETS WITH MASTER CAUTION. GROUNDED - YES. INTERROGATED LEFT AND RIGHT PACK ZONE TEMP CONTROLLERS. RIGHT PZTC "FLIGHT DECK TRIM VALVE" FAULT. BITE TEST PASSED. UNABLE TO DUPLICATE WITH APU. 115V AT PLUG D3886 ON THE CONTROSDR ASAA2019101591013Fitting · gougedWHILE ACCOMPLISHING T/C 78327000 FOUND GOUGE NEAR AFT O/B BOLT ON L/H JACKSCREW SUPPORT FITTING LOOKING AFT. GROUNDED - YES. LOCAL BLEND REPAIRED PER ASA EA 800-27EA-22071.SDR ASAA2019091330704Elastomer · missingWHILE ACCOMPLISHING TC 78472010 ON #2 ENGINE FOUND PLATFORM #18 MISSING THE ELASTOMER FROM ONE ENTIRE SIDE. GROUNDED - YES. REPLACED #2 ENGINE #18 PLATFORM REF TC 78472010.SDR ASAA2019091330699Trim Motor · failedAFTER DEPARTURE ELECTRIC TRIM INOP ON BOTH CONTROL COLUMNS. ENGAGED AUTOPILOT PER QRH & STAB OUT OF TRIM LIGHT ILLUMINATED. GROUNDED - YES. AIR TURNBACK. DIVERSION TIME 51 MINUTES - VERIFIED DEFECT, ACCOMPLISHED FIM 27-41 TASK 804 VERIFIED 115VAC ON D700 PINS SDR ASAA2019091330696Filter · dirtyCONT CAB ZONE TEMP LIGHT ILLUMINATES-RESETS WITH MASTER CAUTION. GROUNDED - YES. PER FIM 21-62 TASK 842 PERFORMED BITE TEST ON PFTC #2, FAULTED FLT DECK TRIM CONTROL VALVE, RESET PFTC #2, AND OPERATED BOTH PACKS TO FULL WARM AND FULL COOL FOR 30 MINUTES PER RESDR ASAA2019091230702Exciter · failedAPU FAULT LIGHT ILLUMINATED DURING START. FAULT LIGHT EXTINGUISHED AFTER 5 MINUTES. GROUNDED - YES. APU WOULD NOT START, TRIED TWICE. REMOVED AND REPLACED APU EXCITER UNIT IAW AMM 49-41-31-000-801 AND 49-41-31-400-801, ETOPS GROUND FUNCTIONAL CHECK GOOD IAW AMSDR ASAA2019091230695Warning System · false activationRIGHT PACK LIGHT ILLUMINATED DURING CLIMB-25000 MSL RAN CHECK LIST AND LIGHT RESET BUT REILLUMINATED NOT LONG AFTER A GOOD RESET. FINISHED CHECKLIST BY TURNING RT PACK OFF AND ISOLATION VALVE TO CLOSED. PRESSURIZATION AND TEMP CONTROL REMAINED GOOD ON L PACK FSDR ASAA2019091230694Control Panel · scratchedCAPT COURSE SELECTOR WINDOW SCRATCHED UP. UNABLE TO CLEARLY READ COURSE. GROUNDED - YES. REMOVED AND REPLACED DFCS MODE CONTROL PANEL PER AMM 22-11-34. DFCS MODE CONTROL PANEL OPS CKS NORMAL PER AMM 22-11-34-740-801. DFCS, LAND VERIFY GRP 49, DFCS CURRENT STATSDR ASAA2019091230681Channel · corrodedFORWARD PIT RT SIDE ZEE CHANNEL CONTAINS SEVERAL SPOTS OF CORROSION FROM STATION 500B TO 500E. GROUNDED - YES. REMOVED DAMAGED ZEE CHANNEL SECTION FROM STATION 500B-500E + 10 AT FORWARD PIT RT SIDE AFTER IT WAS FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2. SDR ASAA2019091230679Charger · inoperativeEMERGENCY LIGHTS COMMON TO POWER SUPPLY M1676 INOP. GROUNDED - YES. REMOVED AND REPLACED BATTERY PACK AND CHARGER ASSY M1676 IAW AMM 33-51-06-960-806. OPS CHK GOOD.SDR ASAA2019091230678Charger · inoperativeEMERGENCY LIGHTS COMMON TO POWER SUPPLY M1676 INOP. GROUNDED - YES. REMOVED AND REPLACED CHARGE ASSY AND BATTERY PACK.SDR ASAA2019091230677Unknown · malfunctionedLEFT WXR IN AUTO & WXTURB WILL INDICATE WX ON ONE SWEEP, THEN BLANK THE NEXT. CONTINUOUSLY ALTERNATES. RT WXR OPS NORMAL. GROUNDED - YES. ACCOMPLISHED FIM 34-43 TASK 814. NO FAULTS NOTED.SDR ASAA2019091130698Overheat Sensor · defectiveAPU DET INOP ILLUMINATED AT CRUISE, APU WAS NOT RUNNING. GROUNDED - YES. FIRE DETECTION MODULE SHOWS APU-TAILPIPE. ACCOMPLISHED FIM 26-10 TASK 808. TAIL PIPE DETECTOR READS 25K OHMS. PER FIM 26-10 TASK 802 REMOVED AND REPLACED APU TAILPIPE OVERHEAT DETECTOR ELSDR ASAA2019091130664Control Valve · failedRIGHT PACK LIGHT ILLUMINATES DURING RECALL AND EXTINGUISHES DURING MASTER CAUTION RESET. GROUNDED - YES. REMOVED & REPLACED TCV2 REF AMM 21-51-10, RT PACK/ZONE TEMP CONTROLLER BITE TEST & LK TEST NML REF AMM 21-61-00-700-806-002. PULLED & RESET 3 TOTAL C/BS. TSDR ASAA2019091130670Charger · inoperativeR1 EMERGENCY LIGHTS INOP GROUNDED - YES. REMOVED AND REPLACED BATTERY CHARGER AND BATTERY SUPPLY IN ACCORDANCE WITH AMM 33-51-06.SDR ASAA2019091030706Wire Harness · faultyREF L/P 12157573, #1 ENG EC BITE TEST STILL SHOWS FAULT MSG 77-20871. GROUNDED - YES. PERFORMED T49.5 PROBE AND EGT SYSTEM INSPECTION PER AMM TASK 77-21-01-200-801-F00. J10 HARNESS FOUND TO HAVE RESISTANCE VALUES OUT OF TOLERANCE FOR S4 TEMP PROBE. REMOVED ANDSDR ASAA2019091030697Oven · faultyFA'S REPORT "ELECTRICAL" SMELLING FUMES, PASSENGER ALSO SMELLS THEM, FROM ABOUT ROW 15 ALL THE WAY TO THE BACK, BUT NOT IN THE GALLEY. QHR3.1 FOLLOWED THROUGH STEP 11. AT THAT POINT ALL FUMES WERE GONE. WE LEFT ITEMS TURNED OFF, OFF FOR REMAINDER OF THE FLIGHTSDR ASAA2019091030655Battery · dischargedR1 EMERGENCY LIGHTS INOP. GROUNDED - YES. T/S AND FOUND R1 DOOR EL BATTERY CHARGER AND BATTERY BAD, REMOVED AND REPLACED M1674 R1 DOOR EL BATTERY CHARGER AND BATTERY IAW AMM33-51-06, OPS CHECKED GOOD IAW AMM 33-51-06-960-806.SDR ASAA2019090930651Unknown · malfunctionedINFLIGHT CA VTK APPEARED-FIXED ITSELF; GPS#2 SIGNAL LOST- NEVER REGAINED. F/O CLOCK INOP; MAIN ENTRY LT APPEARED TURN INTO GATE; F/O HEADSET JACK INOP IRS ON RECALL AFTER VTK. GROUNDED - YES. CYCLE AIRCRAFT POWER FOR SYS RESET. AFTER POWER BACKUP ALL SYS BACK SDR ASAA2019090830631Heat Exchanger · leaking#2 ENGINE DRIPPING FUEL FROM BOTTOM OF COWLING. GROUNDED - YES. PERFORMED OPS CHECK OF #2 ENG VENTS & DRAINS, REF AMM 71-71-00. FOUND MAIN OIL/FUEL HEATER EXCHANGER PAD DRAIN DRIPPING FUEL AT 11 DPM. WITHIN DEFERRABLE LIMITS. MAIN OIL/ FUEL HEATER EXCHANGER TOSDR ASAA2019090830630Drain Valve · leakingRAMP REPORTS FUEL SPRAY FROM #2 ENG ON START. GROUNDED - YES. FOUND HPTACC VALVE DRAIN DRIPPING 8 DROPS PER MINUTE STATIC. NO LEAKS OR DRIPS DURING OR AFTER START, REF AMM 71-71-00. WITHIN DEFERRABLE LIMITS. HPTACCV TO BE REPLACED WITHIN 25 FLIGHT CYCLES. REMOSDR ASAA2019090730660Pressure Switch · failedTANK 2 FWD FUEL PUMP LIGHT ILLUMINATED WITH FULL TANK. GROUNDED - YES. REMOVED AND REPLACED #2 TANK FWD BOOST PUMP LOW PRESSURE SWITCH (S153), OPS AND LEAK CHECK GOOD. REF AMM 28-42-11.SDR ASAA2019090730634Overheat Sensor · faulty"APU DET INOP" LIGHT ILLUMINATED DURING CRUISE FLIGHT. GROUNDED - YES. ENG/APU FIRE DET CTRL MOD SHOWS APU TAIL PIPE LOOP FAULT. REMOVED AND REPLACED APU OVERHEAT DETECTOR ASSY IAW AMM TASK 26-15-01-000-802/26-15-01-400-802. APU FIRE DETECTION OPERATION TEST VSDR ASAA2019090730638Actuator · leakingDURING WALKAROUND NOTICED FUEL DRIPPING FROM #2 ENGINE. GROUNDED - YES. OPENED #2 ENG COWLS. FOUND FUEL DRIPPING FROM LEFT VSV DRAIN TUBE AT 3 DROPS PER MIN. HAD CREW RUN #2 ENGINE AT IDLE. NO LEAKS NOTED DURING IDLE RUN. AFTER SHUT DOWN NO LEAKS NOTED FROM DRSDR ASAA2019090730636Connector · contaminatedIN FLT #2 FWD FUEL PUMP LIGHT ILLUMINATED. GROUNDED - YES. PERFORMED FIM 28-22 TASK 805. FOUND NO FAULTS. OPS TEST GOOD. PERFORMED GOOD INSULATION RESISTANCE CHECK ON #2 FWD BOOST PUMP PER AMM 28-22-00-760-802 AND FIM 28-22 TASK 805. REMOVED CONNECTOR D872 FROSDR ASAA2019090730633Tube · damagedWHILE WORKING ON T/C N8420001, FOUND HPTACC STAGE 9 INLET TUBE DAMAGED BY J9 BRAIDED SHIELD AT CJ9 DISCONNECT. GROUNDED - YES. REPLACED #2 ENG HPTACC INLET TUBE REF AMM 75-21-01-400-801-F00 STEPS 3G (5)-3G (6).SDR ASAA2019090730632Wire Harness · damagedWHILE WORKING ON T/C N8420001, FOUND J9 HARNESS METAL BRANDED SHIELD DAMAGED AT CJ9 DISCONNECT. GROUNDED - YES. DAMAGE IS ON THE #2 ENGINE J10 HARNESS, REPLACED J10 REF AMM 73-21-06-400-802. PERFORMED FADEC SYSTEM TEST IAW AMM 73-21-00-700-802-F00, ALL TESTS PSDR ASAA2019090530753Bracket · crackedFORWARD PIT LT SIDE HAS ANGLE BRACKET CRACKED AT LBL 23 APPROX STATION 500H, UNDERNEATH ZEE CHANNEL. GROUNDED - YES. REMOVED CRACKED ANGLE BRACKET LOCATED AT FWD PIT LT SIDE AT APPROX LBL 23, STATION 500H UNDERNEATH ZEE CHANNEL AND REPLACED WITH NEW ANGLE BRACSDR ASAA2019090530740Transition Panel · crackedAFT CARGO RT TRANSITION PANEL CRACKED STA 727H. GROUNDED - YES. AFT CARGO RT TRANSITION PANEL EVALUATED AND FOUND TO BE OUT OF LIMITS IAW 53-00-53-1A-2 REMOVED AND INSTALLED NEW TRANSITION PANEL IAW SRM 53-00-53-2R-5 AND 51-40-02 REPLACED ZEE CHANNEL FROM BS72SDR ASAA2019090530714Bracket · crackedFORWARD PIT RT SIDE HAS ANGLE BRACKET CRACKED AT RBL 24 APPROX, STATION 500G AFT SIDE, UNDERNEATH ZEE CHANNEL. GROUNDED - YES. REMOVED CRACKED ANGLE BRACKET LOCATED AT FWD PIT RT SIDE AT APPROX RBL 24, STATION 500G AFT SIDE UNDERNEATH ZEE CHANNEL AND REPLACED SDR ASAA2019090530627Unknown · malfunctionedAUTOLAND UNSUCCESSFUL. AT APPROX 100 FT AGL, A/C TURNED HARD RIGHT AND AUTOPILOT HAD TO BE DISCONNECTED TO MAINTAIN CONTROLLED FLIGHT. LANDED MANUALLY. ALL INDICATIONS NORMAL DOWN TO 100' AGL. (NOTE: HGS AIII OPERATED NORMALLY). GROUNDED - YES. DFCS 1&2 SHOW NSDR ASAA2019090430798Splice Plate · corrodedFRAME BEEF UP PLATE & SUB STRUCTURE RH @ STA 787 IS CORRODED - DOT & STREAMER ATTACHED. GROUNDED - YES. REMOVED AND REPLACED CORRODED FRAM SPLICE PLATE @ BS787 WITH NEW SPLICE PLATE P/N 146A1300U3 PO# 954829.1 PER BAC DWG #1436A1262 REV -.SDR ASAA2019090430797Door Sill · corrodedAFT CARGO DOOR SILL PLATE HAS SEVERAL AREAS CORRODED - DOT & STREAMER ATTACHED. GROUNDED - YES. REMOVED AND REPLACED (WEB) DOOR SILL PLATE REF BAC DRWG 146A8340.SDR ASAA2019090430728Shield · corrodedFLOORBEAM TRANSITION PLATE RT FROM STA 767 TO STA 787 IS CORRODED. DOT & STREAMER ATTACHED. GROUNDED - YES. REMOVED CORRODED SHIELD FROM BS767-BS787, LOCATED AND DRILLED NEW SHIELD P/N 146A8127U12 PO# 954475.1 INSTALLED NEW SHIELD PER BAC DWG # 146A0081 REV -.SDR ASAA2019090430727Floorbeam · damagedFLOORBEAM @ STA 727I LH HAS PULLED THRU FASTENED- DOT & STREAMER ATTACHED. GROUNDED - YES. REMOVED AND REPLACED DAMAGED ZEE CHANNEL SECTION FROM LT STA 727 TO 827+8 IAW SRM 53-00-53-2R-5 REPAIR 5.SDR ASAA2019090430713Bracket · crackedFORWARD PIT RT SIDE HAS ANGLE BRACKET CRACKED AT RBL 24 APPROX, STATION 500G, UNDERNEATH ZEE CHANNEL. GROUNDED - YES. REMOVED CRACKED ANGLE BRACKET LOCATED AT FWD PIT RT SIDE AT APPROX RBL 24 STATION 500G UNDERNEATH ZEE CHANNEL AND REPLACED WITH NEW ANGLE BRACSDR ASAA2019090430687Bracket · crackedFORWARD PIT RT SIDE HAS ANGLE BRACKET CRACKED AT RBL 24 APPROX, STATION 500F, UNDERNEATH ZEE CHANNEL. GROUNDED - YES. REMOVED CRACKED ANGLE BRACKET AT FWD PIT RT SIDE APPROX RBL 24, STATION 500F UNDERNEATH ZEE CHENNEL AND REPLACED WITH NEW ANGLE BRACKET IAW SRSDR ASAA2019090430682Bracket · crackedFORWARD PIT RT SIDE HAS ANGLE BRACKET CRACKED AT RBL 24 APPROX, STATION 500H, UNDERNEATH ZEE CHANNEL. GROUNDED - YES. REMOVED CRACKED ANGLE BRACKET AND REPLACED WITH NEW ANGLE BRACKET AT FORWARD PIT RT SIDE IAW SRM 51-40-02 AND DWG 143A7505 REV - AT APPROX RBLSDR ASAA2019090430680Shield · corrodedFORWARD FLOOR SUPPORT SHIELD IN FORWARD PIT RT SIDE IS CORRODED (STATION 500 RBL 24 APPROX.). GROUNDED - YES. BLENDED CORROSION FROM SHIELD IN FWD PIT RT SIDE @ BS 500 ORG MAT .032, REMOVED .005, .027 REMAINS. FOUND TO BE OUT OF LIMITS PER 53-30-15. REMOVED ANSDR ASAA2019090430658Actuator · faultyWHILE PERFORMING T/C 78273000 #2 ENG FOUND FAULT CODE #75-10442 VBV SIGNAL OUT OF RANGE. GROUNDED - YES. REF TSR703795 REMOVED AND REPLACED #2 ENGINE RT VBV ACTUATOR S/N YU023186-K PER AMM 75-32-02. OPS CHECKS AND LEAK CHECKS GOOD. GROUND VERIFICATION SUCCESSFSDR ASAA2019090430616Skin · corrodedCORROSION AROUND LAV VENT OPENING. GROUNDED - YES. REPAIRED SKIN IAW SRM 53-70-01-2R-3. THIS IS A CAT B REPAIR WITH AN INSPECTION THRESHOLD OF 50,000 CYCLES, A/C CYCLES AT TIME OF REPAIR 14,913W-1"O-.125"R-0.0L-1"D-.125".
Back to Boeing 737-890