SDR ASAA2015041311341Satcom · lockedSATCOM LOCKUP. ACFT GROUNDED. SATCOM LOCK-UP PROCEDURE PERFORMED, NORMAL OPS RESTORED.SDR ASAA2015041311340Satcom · lockedSATCOM LOCK UP. ACFT GROUNDED. COMPLETED QRH, SATCOM LOCKUP PAGE 53. OPS NORMAL.SDR ASAA2015041211314Satcom · malfunctionedTRANSFERRING TO APU PWR FROM GROUND PUSH LOST SAT COM PROMPT ON FMC/ACARS MENU. ACFT GROUNDED. ACCOMPLISHED QRH. QRH PROCEDURE RESTORED SAT COM.SDR ASAA2015041211303Probe · faultedWHILE ACCOMPLISHING T/C 78273000, FOUND NR 2 ENGINE ECONOMIC FAULT 73-31372 ON LEG 2 & 10. UPPER EGT SECTORS READING HIGH. ACFT GROUNDED. ACCOMPLISHED T49.5 PROBE AND EGT SYS INSPECTION IAW AMM 77-21-01-200-801-F00. FOUND RESISTANCE TO S4 PROBE MEASURING EXSDR ASAA2015041111472Floor Panel · gougedPER CUSTOMER REP NED: FABRICATE NEW AFT CARGO COMPARTMENT FLOOR PANEL 140EF DUE TO SEVERAL DEEP GOUGES. GROUNDED - YES. FABRICATED NEW FLOOR PANEL 140EF AFT CARGO PIT IAW BAC DWG 453A2610 ALODINED AND PRIMED AIW B737-800 SRM 51-20-01.SDR ASAA2015041111299Apu · faultedAPU BITE INOPERATIVE, NO INTERFACE BETWEEN APU AND ECU. ACFT GROUNDED. ACCOMPLISHED FIM 49-65, TASK 801 FAULT ISOLATION PROCEDURES A THRU F. BITE RESTORED. ACCOMPLISH APU BITE 49-60-801.SDR ASAA2015041111295Fmc · failedUPON TOUCHDOWN F/O'S FMC SCREEN FLICKERS WITH A LINE THROUGH SCREEN AS WELL; SCREEN SEEMS TO BE FAILING. ACFT GROUNDED. CONFIRMED FAULT, F/O FMC CDU DISPLAY INTERMITTENT. R & R F/O FMC CDU REF AMM 34-61-01, OPS CK NORMAL. ALSO, ACCOMPLISHED CDU SOFTWARE CONSDR ASAA2015041111294Warning Message · false activationFMC DISAGREE MESSAGE DISPLAYED ON CDU'S AND NAV DISPLAYS. ACFT GROUNDED. ACCOMPLISHED QRH. ISSUE RESOLVED.SDR ASAA2015041111289Indicator · inoperativeQTY INDICATOR INOPERATIVE, NR 1 TANK. ACFT GROUNDED. OPS CKD FQI ON RE-FUEL ALL OPS NML 28-40-00.SDR ASAA2015041111287Satcom · lockedSATCOM LOCKUP AFTER ENGINE START. ACFT GROUNDED. QRH FOLLOWED, SATCOM RESTORED.SDR ASAA2015041011470Channel · corrodedAFT CARGO COMPARTMENT, R/H SIDEPLATE HAS CORROSION STA 727C - 767. GROUNDED - YES. REMOVED CORROSION AND FOUND BEYOND ALLOWABLE LIMITS OF 10% MAX THICKNES IAW ASA 737-800 SRM 53-00-53-A1-2,ORIGINAL MATERIAL THICKNESS IS .040 IN IAW ASA 737-800 SRM 53-60-53-0ISDR ASAA2015041011461Shield · corrodedAFT CARGO COMPARTMENT, DOOR SURROUND SHIELD STA 767-794 HAS CORROSION. ACFT GROUNDED. REMOVED CORROSION AND FOUND BEYOND ALLOWABLE LIMITS IAW SRM 53-60-15-1A-1, FIG 103, DETAIL D, MAX ALLOWABLE THICKNESS REMOVED IS 10 PERCENT ORIGINAL MATERIAL THICKNESS IS 0.SDR ASAA2015041011392Door Frame · gougedAFT ENTRY DOOR FORWARD UPPER STOP FITTING GOUGED. ACFT GROUNDED. AFT ENTRY DOOR FWD. UPPER STOP FITTING FOUND TO BE OUT OF LIMITS REF SRM 52-10-90-1A-1. REMOVED UPPER & FWD LINER SUPPORT, UPPER GATE AND DISPLACED PRESSURE SEAL TO FOM REF SRM 51-40-02, AND SDR ASAA2015041011302Panel · bentNR 1 ENGINE INBD SIDE FAN DUCT PANEL AT 12 TO 1 O'CLOCK ALF UPPER ATF CORNER IS DISTORTED/BENT. ACFTGROUNDED. R & R NR 1 ENG INBD SIDE FAN DUCT PANEL AT 12 O`CLOCK REF MM 72-23-07.SDR ASAA2015041011296Valve · failedNR 1 BLEED TRIP OFF LIGHT ILLUMINATED DESCENDING THROUGH 380. ACCOMPLISHED BLEED TRIP OFF CHECKLIST. LIGHT REMAINED ILLUMINATED. ACFT GROUNDED. ACCOMPLISHED T/C NG-36WC-00001. FOUND PCU VALVE & PRSOV FAILED. R & R PRECOOLER CONTROL VALVE REF AMM 36-12-02 OSDR ASAA2015041011293Warning Message · false activationFMC DISAGREE ON GROUND. ACFT GROUNDED. FOLLOWED QRH PROCEDURE, OPS NORMAL.SDR ASAA2015041011292Warning Message · false activationFMC DISAGREE ON GROUND. ACFT GROUNDED. ACCOMPLISHED QRH PROCEDURE. RESTORED BOTH FMC'S.SDR ASAA2015041011284Actuator · failedRT PACK LIGHT CAME ON DURING TAXI IN, DID NOT ATTEMPT RESET. ACFT GROUNDED. REPLACED RIGHT RAM AIR DOOR ACT IAW AMM 21-51-21. GROUND VERIFICATION CHECKED GOOD. ACCOMPLISHED RAM INLET ACTUATOR TEST, BITE TEST OF RT PACK ZONE TEMP CONTROLLERS. FAULT RESET.SDR ASAA2015040911304Probe · faultedDIAGNOSTIC REPORTS NR 1 ENGINE TREND DATA SHOWS A SHIFT IN CRUISE AND TAKEOFF MARGIN INDICATIVE OF EGT INDICATION ERRORS. ACFT GROUNDED. WHILE COMPLYING WITH TC 78273000 FOUND ECONOMIC FAULT 77-20861 ON ENGINE 1ESN894921. READINGS OF ENGINE NR 1 T49.5 PROBESDR ASAA2015040911301Window · bindingL2 WINDOW BINDS, DIFFICULT TO OPEN AND CLOSE. DOES NOT SMOOTHLY RUN THRU TRAVEL. ACFT GROUNDED. ADJUSTED AND OPS CHECKED L2 WINDOW IAW AMM 56-12-11.SDR ASAA2015040911300Warning Light · illuminatedAFTER LANDING, APU FAULT LIGHT ILLUMINATED ON FIRST ATTEMPT, AFTER 5 MINUTES, FAULT LIGHT EXTINGUISHED AND APU STARTED ON SECOND ATTEMPT. ACFT GROUNDED. PERFORMED APU BITE PROCEDURE FOUND FAULT CODE 49-41011 FIM NO FLAME SHUTDOWN. PERFORMED APU START, STARTSDR ASAA2015040911291Fmc · malfunctionedTEMPORARY LOSS OF RT FMC APPROXIMATELY 4 + 25 MINUTES INTO FLIGHT. RESTORED TO NORMAL OPERATION WITHIN 2 MINUTES. ACFT GROUNDED. ACP FIM TASK 34-61-801. NO FAULTS LOGGED. GROUND VERIFICATION CK GOOD. REF AMM 34-61-00-710-801. NO PREVIOUS HISTORY IN 30 DAYSSDR ASAA2015040911290Fmc · lockedFMC LOCKED UP. ALTITUDE SHOWS 50,000 FT SEL SPD, NO VSPD, FD AND LG ALT FLAGS ON BOTH ATTITUDE DISPLAYS. INITIALLY HAD FMC DISAGREE AND FOLLOWED QRH PROCEDURE. FMC DISAGREE WENT AWAY BUT OTHER INDICATIONS REMAINED. ACFT GROUNDED. FOUND THAT MCP HAD LOCKEDSDR ASAA2015040911288Satcom · lockedSATCOM LOCKUP OCCURED WHEN APU PWR APPLIED. ACFT GROUNDED. ACCOMPLISHED QRH CHECKLIST. ISSUE CORRECTED.SDR ASAA2015040911285Valve · failedPACK LIGHT ON RECALL EXTINGUISHED WITH RESET. ACFT GROUNDED. R & R LT PACK TEMP CONTROL VALVE IAW AMM 21-51-103.SDR ASAA2015040911283Warning Light · false activationLT PACK LIGHT ILLUMINATED. ACFT GROUNDED. SUSPECT LT PACK OVER TEMPED. RESET PUSHING RESET BUTTON. PERFORMED BITE OF TEMP CONTROLS TCU FAULT LOGGED BUT CLEARED. NO HISTORY NOTED 30 DAYS. OK FOR CONTINUED SERVICE. REF FIM 21-62, TASK 801.SDR ASAA2015040811279Lamp · inoperativeFOUND EMERGENCY AREA LIGHT AT 11ABC INOPERATIVE. ACFT GROUNDED. REPLACED THE LAMP IAW AMM 33-51-03-960-801. OPS CHECKED GOOD.SDR ASAA2015040811277Satcom · lockedEXPERIENCED SATCOM LOCK UP AFTER ENGINE START AND AFTER BOTH GENERATORS WERE POWERING THE BUSES. ACFT GROUNDED. QRH PROCEDURE ACCOMPLISHED. SATCOM OPS NORMAL.SDR ASAA2015040711263Hf Comm · inoperativeHF 1 AND 2 SHOW INOPERATIVE ON BOTH RADIO TUNING PANELS. ACFT GROUNDED. PERFORMED AMM 23-12-41-800-802 TASK PROCEDURE RADIO TUNING PANEL RESET. GROUND OPS CHECK NORMAL.SDR ASAA2015040711261Satcom · lockedSATCOM LOCK UP: ACFT GROUNDED. QRH CHECKLIST PROCEDURES COMPLETED. OPS NORMAL.SDR ASAA2015040711245Vent · unknownFOLLOW-UP TO NR 2 IDG CONTINUED FREQUENT OIL SERVICING. ACFT GROUNDED. RAN NR 2 END AT IDLE FOR 10 MIN THEN CHECKED FOR OIL ACCUMULATION FROM DRAIN, NO OIL LEAKS OR ACCUMULATION NOTED. R & R THE VENT VALVE IAW AMM 24-11-00-700-804, AS REQUESTED.SDR ASAA2015040611253Warning Light · false activationPACK LIGHT ON RECALL EXTINGUISHES WITH MASTER CAUTION RESET. ACFT GROUNDED.SDR ASAA2015040611257Sensor · failedRT SIDE FORWARD WINSHIELD OVERHEAT LIGHT ILLUMINATED. ACFT GROUNDED. PERFORMED BITE TEST FOR RT SIDE FWD WINDSHIELD. FOUND WINDOW SENSOR FAULT. REF FIM 30-41-00-810-801. SWITCHED TO ALTERNATE SENSOR. OVERHEAT LIGHT WENT OUT. BITE CHECK GOOD. REF AMM 30-41SDR ASAA2015040611256Control Unit · malfunctionedFOUND CIRCUIT BREAKER "INVERTER VOLTS" ON SPCU POPPED AND HEAD BROKEN OFF. ACFT GROUNDED. REPLACED SPCU, OPS CK NORMAL REF MM 24-34-11.SDR ASAA2015040611255Satcom · lockedSATCOM LOCK-UP, ACFT GROUNDED. SATCOM LOCK-UP PROCEDURE PERFORMED SUCCESSFULLY.SDR ASAA2015040611254Satcom · lockedSAT COM LOCK UP. ACFT GROUNDED. QRH CHECKLIST 5.3 COMPLETED, NORMAL OPS RESTORED.SDR ASAA2015040511248Shim · worn24 EA SHIMS WORN & MISSING COATING, NR 2 ENGINE. ACFT GROUNDED. R & R 24 EA SHIMS IN REF TASK CARD 78472002, NR 2 ENGINE.SDR ASAA2015040511247Indication Sys · malfunctionedRIGHT AS THE CENTER TANK WAS EMPTY, IMBALANCE SHOWED ON THE FUEL QTY INDICATOR. NR1 MAIN TANK INDICATED 6.85, NR 2 MAIN INDICATED 8.55. FOLLOWED QRH FOR CROSSFEED, AFTER CROSSFEED WAS COMPLETE NR 1 TANK INDICATIONS DID NOT DECREASE FOR AWHILE. THAN INDICATIOSDR ASAA2015040411227Indicator · failedREFUELING NR 2 FUEL QUANTITY INDICATION SHOWING 8'S, AS IF IN A TEST MODE. ACFT GROUNDED. REPLACED NR 2 FUELING FUEL QUANTITY INDICATOR, OPS NORMAL, REF AMM 28-41-61-400-801.SDR ASAA2015040411223Valve · malfunctionedAFTER ENGINE START AND MASTER CAUTION RECALL THE RIGHT PACK LIGHT ILLUMINATED. COMPLIED WITH QRH AND LIGHT RESET. ACFT GROUNDED. TEMPERATURE CONTROL VALVE HARD FAULT ON TEMP CONTROLLER NR 2. R & R NR 2 TEMPERATURE CONTROL VALVE IAW AMM 21-51-10-000-801 AND SDR ASAA2015040411220Valve · malfunctionedLEFT PACK LIGHT ILLUMINATED ON RECALL. ACFT GROUNDED. REPLACED LT PACK TEMP CONTROL VALVE AS REQUIRED. OPS CKD GOOD. LEAK CHECKED GOOD, REF AMM 21-51-10-400-801.SDR ASAA2015040311234Engine · failedDURING START OF NR 2 ENGINE, FAILED TO INCREASE AT NORMAL RATE FOLLOWED BY FLASHING START VALVE OPEN LIGHT AND LOW OIL PRESSURE LIGHT. ACFT GROUNDED. ACCOMPLISHED 2 NORMAL ENGINE STARTS ALL PARAMETERS NORMAL, EEC BITE SHOWS NO FAULTS.SDR ASAA2015040311232Fastener · looseREF T/C 78472000, NR 2 ENGINE FAN DUCT PANEL, WITH LPTACC SCOOP, AT 4-5 OCLOCK, ALF, LOWER MIDDLE FASTENER LOOSE, DAMAGED. FAN DUCT PANEL AT 5-6 OCLOCK, ALF, UPPER AND LOWER MIDDLE FASTENERS PULLED THROUGH PANEL. ACFT GROUNDED. R & R THE NR 2 ENGINE FAN DUCSDR ASAA2015040311231Spinner · unknownWHILE WORKING TC 78472002, FOLLOWING ITEMS REQUIRE REPLACEMENT ON NR 2 ENGINE. FRONT SPINNER CONE, ALL SHIMS, PLATFORMS AND SPACERS FROM BLADES 19 AND 22. ACFT GROUNDED. INSTALLED NEW FRONT SPINNER CONE, ALL SHIMS AND PLATFORMS AND SPACERS FROM BLADES 19 ANSDR ASAA2015040311226Wire Harness · failedNR 2 ENGINE "B" LOOP INOPERATIVE. ACFT GROUNDED. FOUND NR 2 ENGINE "B" LOOP DETECTOR, RT SIDE CORE, OPEN. REPLACED RT SIDE CORE LOOP FIRE DETECTOR IAW AMM 26-11-01-401. ENGINE FIRE OPS TEST GOOD IAW AMM 26-11-00-710-801.SDR ASAA2015040311225Satcom · lockedSATCOM LOCKUP WITH POWER CHANGE. ACFT GROUNDED. FOLLOWED QRH PROCEDURES. SATCOM RESTORED.SDR ASAA2015040311224Satcom · lockedSATCOM LOCKUP. ACFT GROUNDED. SATCOM LOCKUP CHECKLIST PERFORMED AND SYS RESTORED.SDR ASAA2015040211237Start Valve · failedNR 2 ENGINE, NO N2 ROTATION WITH START SWITCH IN GROUND. ACFT GROUNDED. REPLACED NR 2 ENGINE START VALVE, REF MM 80-11-03-400-801-F00. OPS CHECK NORMAL.SDR ASAA2015040211229Lens · missingEMERGENCY EXIT ROW 17 DEF MISSING EMERGENCY LIGHT COVER. GROUNDED - YES. INSTALLED NEW EMERGENCY EXIT LIGHT COVER @ ROW 17 DEF AS REQUIRED. OPS CKD GOOD, REF AMM 33-51-01-960-801.SDR ASAA2015040211228Sensor · failedRIGHT SIDE WINDOW HEAT OVERHEATED, QRH PROCEDURES DONE, LIGHT STILL ILLUMINATED. ACFT GROUNDED. FOUND SENSOR IN RT SIDE WINDOW INOPERATIVE. SWAPPED SENSOR WIRE TO OTHER SENSOR IAW AMM 30-41-TASK 811. OPS CHECKS GOOD. PERFORMED WINDOW HEAT CONTROL UNIT SYS T
Back to Boeing 737-890