Boeing 737-890
Service difficulty reports · 23,038
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '737890' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '737890' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR ASAA12510905Filter Element · defectiveFOUND THE LUBE OIL MODULE OIL FILTER INDICATOR EXTENDED. PERFORMED OIL FILTER INDICATOR INSPECTION REF MM 49 91 13 200 801. REPLACED LUBE FILTER ELEMENT & RESET OIL FILTER INDICATOR REF MM 49 91 13 600 801. SERVICED APU OIL TO FULL REF MM 12 13 31.SDR ASAA12510904Ecu · faultyBLUE APU "MAINT" IS ILLUMINATED. VERIFIED OIL LEVEL ON APU SIGHT GLASS AND CDU SHOW FULL. PERF APU BITE PROCEDURE PER FIM TASK 49 60 00 810 801 NO FAULTS. TECH SERVICES REQ T/S OF APU OIL QUANTITY INDICATION ERRORS. COMPLETED STEPS OF FIM 49 90 00 810 804 SDR ASAA12510899Actuator · malfunctionedRIGHT PACK LIGHT CAME ON DURING RECALL ON LANDING CHECK MASTER CAUTION RESET LIGHT GOES OUT. BITE CKD BOTH CONTROLLERS MM 21 60 00 NR 2 FAULTED RAM AIR ACTUATOR WAS ABLE TO RESET 2ND OCCURANCE IN 2 WEEKS. REPLACED RT RAM AIR INLET ACTUATOR OPS CHECKED GOOD RSDR ASAA12510906Igniter · inoperativeNR 1 ENG LEFT IGNITION DOES NOT WORK. ACCOMPLISHED FIM TASK 74 21 00 810 806 F00 EEC BITE CHECK SHOWED NO FAULTS LOGGED. DURING FURTHER T/S FOUND NO AUDIBLE CONFIRMATION OF IGNITOR PLUGS IGNITING. REPLACED NR 1 ENGINE IGNITOR PLUGS REF T/C 78474000 SYSTEM OSDR ASAA12510902Unknown · unknownAFTER LANDING APU GEN READ 0 VOLTS/0 FREQ WOULD NOT GO ON LINE WITH APU OFF BUS LIGHT ILLUMINATED. ACCOMPLISHED APU BITE TEST REF FIM TASK 49 60 TASK 801 FOUND FAULT CODE 49 31171 LOGGED. REF FIM TASK 49 31 00 810 808 ACCOMPLISHED APU STARTING OPERATIONAL CHSDR ASAA12510898Unknown · malfunctioned"AUTO FAIL" AND "ALTN" ILLUMINATED ON PRESSURIZATION PANEL W/AUTO. FAULT CLEARS AFTER SWITCHING FROM AUTO TO MANUAL TO AUTO. NR 2 PRESS CTLR INDICATES NO FAULTS. NR 2 DCPC INDICATES FAULT CONT PNL 101. TROUBLESHOT PER FMI 21 31 00 810 801 BITE CHECK PER FISDR ASAA1250897Circuit Breaker · openAUTOTHROTTLE DC 1 (P18 1 E1) CB FOUND OPEN. VERIFIED INSECTION OF C/B AND ASSOCIATED WIRING BEHIND P18 1 PANEL GOOD. RESET AT DC1 C/B REF MM 20 60 01, OPS TEST PASSED REF MM 22 31 00.SDR ASAA12510895Unknown · malfunctionedFMC DISAGREE ON TAXI OUT AT PDX. ACCOMPLISHED QRH PROCEDURE. LIGHT EXTINGUISHED.SDR ASAA12510894Warning System · false activationRIGHT PACK LIGHT ILLUMINATES WITH MASTER CAUTION RECALL. LIGHT EXTINGUISHES WITH RESET. PERFORMED BITE CK OF NR 2 ZONE TEMP CNTL PER AMM REF 21 61 00. FAULTS 32 PACK RAM AIR ACTUATOR. PERFORMED FAULT RESET PROCEDURE PER SAME REF FAULT CLEARED PACK LIGHT EXSDR ASAA12510881Starter Gen · faultyAPU WOULD NOT START GOT A FAULT & MAINTENANCE LIGHT. FAULT CODE 49 41244 GENERATOR FAIL. REPLACED STARTER GENERATOR REF AMM 49 41 21. OPS AND LEAK CHECKED GOOD. APU BITE CHECK GOOD NO FAULTS NOTED REF AMM 49 61 00 700 801.SDR ASAA12510882Panel · looseWHILE ACCOMPLISHING ENGINE INLET AND FAN BLADE INSP FOUND FAN DUCT PANELS LOOSE. PANELS NR 6, 7, 8, 9 AND 12. TIGHTEN SCREW ON FAN DUCT PANEL NR 1 ENG REF MM 72 23 07.SDR ASAA12510880Warning System · false activationLEFT WINDOW HEAT "OVERHEAT" LIGHT ILLUMINATED TWICE BEFORE RESET ON GREEN "ON". ACCOMPLISHED FIM TASK 30 40 00. SYSTEM OPS CHECKS GOOD. GROUND VERIFICATION SUCCESFUL PER FIM. AC GOOD FOR CONT SERVICE.SDR ASAA12510879Cam · obstructedF/A REPORTS CAN'T SHUT FRONT L1 DOOR. FOUND AND REMOVED DEBRIS IN UPPER HINGE LOWER CAM PLATE L1 DOOR FRAME WHICH KEPT DOOR PRELOADED PREVENTING GUST LOCK LEVER EASY TRAVEL. L1 DOOR GUST LOCK RELEASES AND DOOR CLOSES NORMAL REF 52 11 00.SDR ASAA12510878Fastener · missingUPON ARRIVAL L1 DOOR COULD NOT BE OPENED. WHEN DOOR DID OPEN IT MADE SOME LOUD GRINDING NOISES. FOUND SCREW & KEY WASHER MISSING FROM GUIDE ARM LOWER RADIUS LINK. INSTALLED NEW SCREW & KEY WASHER & DOOR OPERATES NORMALLY. REF MM 52 11 21 400 802 STEP 4. D GSDR ASAA12510874Unknown · malfunctionedCONT CABIN ZONE TEMP LIGHT ILLUMINATES ON RECALL. RAN BITE TEST NR 2 CONTROLLER FLT DECK TRIM VALVE ILLUMINATED. RAN GROUND VERIFY NO FAULTS RERAN BITE NO FAULTS NOTED.SDR ASAA12510871Apu · failedAPU QUIT ON PUSHBACK. REPLACED APU LOW OIL PRESS SWITCH IAW MM49 94 22, NO HELP. REPLACED APU ECU IAW MM 49 61 12, NO HELP. RE-INSTALLED ORIGINAL PART. REMOVED AND REPLACED APU PER T/C 78349010. OPS CHECK NORMAL. A/C OK FOR SERVICE.SDR ASAA12510929Trans Panel · crackedAFT CARGO BILGE AREA RT TRANSITION PANEL IS CRACKED AT BS 747. CUT OUT DAMAGED SECTION AND FABRICATED ZEE CHANNEL SIDEPLATE AND SPLICE SIDEPLATE (ITEM 1 & 2) P/N BAC1496 377 7075 T62 IAW B737 800 SRM 53 00 53 FIG 202 REPAIR 5. ALODNED AND PRIMED IAW B737 800SDR ASAA12510872Valve · malfunctionedLEFT BLEED TRIP OFF LIGHT ILLUMINATED ON DESCENT. WOULD NOT RESET. COMPLETED FIM 36 10 00 810 801 A THRU E(2). BLEED TRIP RESET SUCCESSFUL ON GROUND. CREW STATED DESCENT FROM 38 000 FEET LEFT PACK TRIPPED WAITED 1:30 MIN TRIED TO RESET NO GOOD. DUCT PRESSSDR ASAA12510873Unknown · malfunctionedHF2 SHOWS FAIL WHEN SELECTED. PERFORMED HF COMMUNICATION SYSTEM TEST. OPS CHECK GOOD. REF AMM 23 11 00 730 801.SDR ASAA12510870Cdu · defectiveFMC SCREEN ON F/O'S SIDE "FLICKERS" AND BUTTONS ON LT & RT SIDE DID NOT LIGHT UP. REPLACED F/O MCDU AMM 34 61 00. OPS CHECKED NORMAL.SDR ASAA11510866Apu · malfunctionedDUE TO APU EGT ABOVE THE THRESHOLD POWERPLANT ENGINEERING REQUEST THE APU BE REMOVED. REPLACED APU. OPS/LEAK CHECK OK. REF T/C 78349010.SDR ASAA11510867Apu · malfunctionedAFTER APU START "DIRTY SOCK SMELL WAS PRESENT IN CABIN AND COCKPIT, WENT AWAY AFTER ENGINE START. ON LANDING SAN SAME SMELL WAS AGAIN PRESENT. DUE TO RECENT HISTORY ENGINEERING REQUESTS APU BE REPLACED. OIL FOUND AT APU BLEED AIR VALVE CONFIRMING APU AS THESDR ASAA11510869Sensor · defectiveLT SIDE WINDOW OVHT LIGHT ILLUMINATED DURING PREFLIGHT. PERFORMED BITE CHECK OF LT SIDE WHCU. FOUND LT SIDE SENSOR FAULT. PERFORMED FIM TASK 30 41 00 810 811. ON LT SIDE WINDOW SWAPPED SENSOR TO SPARE SENSOR. SYSTEM OPS CHECK NORMAL PER AMM 30 41 00 710 8SDR ASAA11510868Unknown · malfunctionedON LANDING IN ANC PRESSED RECALL PER LANDING CHECK LIST M/C LIGHT CAME ON RIGHT PACK AMBER LIGHT ON M/C RESET LIGHT OUT. RAN BITE TEST FOUND RT PACK RAM AIR ACT LIGHT. RAN GROUND VERIFY PROBLEM CLEARED. RERAN BITE TEST GOOD. OK FOR SERVICE.SDR ASAA12510930Seat Track · corrodedFORWARD CARGO COMPARTMENT AFT BULKHEAD LT/SIDE SEAT TRACK MOUNT CORRODED. REPAIRED TRACK IAW B737 800 SRM 53 00 53 REPAIR 3. REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS IAW B767 800 SRM 53 00 53. REMOVED DAMAGED SECTION IAW B737 800 SRM 53 00 53 REPAIR SDR ASAA11510863Control Valve · faultyMASTER CAUTION RECALL ILLUMINATES AIR COND CAUTION LIGHT WITH ASSOCIATED LEFT PACK LIGHT. MASTER CAUTION RESET EXTINGUISHES BOTH LIGHTS. BITE CHECKS SHOWS TCV FAULT. REPLACED LEFT PACK TEMP CONT. VALVE PER AMM 21 51 10 000 801. OP'S GOOD NO LEAKS NOTED.SDR ASAA11510864Wire Harness · defectiveDURING CRUISE FLIGHT 4 HOURS AFTER TAKEOFF LEFT SIDE WINDOW HEAT AMBER OVERHEAT OCCURRED. QRH FOLLOWED. OVERHEAT CONDITION WOULD NOT RESET. PERFORMED WINDOW HEAT CONTROL UNIT BITE CHECK NO ACTIVE FAULTS FOUND. HISTORICAL FAULT LT SIDE WINDOW SENSOR SHOWN. CSDR ASAA1150862Unknown · malfunctionedLEFT PACK LIGHT ILLUMINATED ON GROUND. ACCOMPLISHED BITE PROCEDURE ON PACK/ZONE TEMP CONTROLLERS. A TCV FAULT SHOWED ON THE NR 1 TEMP CONTROLLER. FAULT CLEARED & TEMP CONTROLLERS SHOW NO NEW FAULTS. GROUND VERIFIED BY RUNNING APU & A/C PACKS. NO FAULTS INSDR ASAA11510861Warning System · false activationCONT CAB ZONE TEMP LIGHT ILLUMINATES WITH MASTER CAUTION RECALL AND EXTINGUISHES WITH MASTER CAUTION RESET. ACCOMPLISHED FIM TASK 21 62 00 ZONE TEMP BITE, OPS CHECK NORMAL. GROUND VERIFICATION SUCCESSFUL.SDR ASAA11510860Drain Mast · crackedAPUR SHROUD AND HYD DRAIN MAST AFT OF LT W/W APPEARS CRACKED AT THE BASE ON THE T/E. VERFIED CRACK USING HFEC 2.0 IN ON OTBD SIDE AND 3.0 IN ON INBD SIDE PER BOEING NDT MANUAL 51 00 00 FIG 23 PART 6. REPLACED APU FUEL FEED LINE SHROUD DRAIN MAST REF MM 25 25SDR ASAA11510859Shim · damagedNR 2 ENG FAN LUBE 24 EA FAN BLADE SHIMS REQ REPLACEMENT P/N 340 252 307 0 NO MOLY 0 DAG COATING. NR 2 ENG 24 SHIMS P/N 340 252 307 0 REPLACED REF T/C 78472002.SDR ASAA11510858Battery Pack · failedREF T/C 78233001: EMERGENCY LIGHT BATTERY PACKS M1672 & M1675 FAILS CAPACITY CHECK. REF WDM 33 51 12 & 33 51 14. REPLACED AND TESTED EMERGENCY LIGHT BATTERY PACKS M1675 & M1675 PER MM 33 51 06 960 805, OPS NORMAL.SDR ASAA11510856Unknown · malfunctionedON RECALL LEFT PACK LIGHT ILLUMINATES. EXTINGUISHES UPON RESET. BITE OF NR 1 ZONE TEMP CONT SHOWS THIS PACK TCV FAULT. RESET TEMP CONT. NO FAULTS AT THIS TIME ON NR 1 OR NR 2 TEMP CONT.SDR ASAA11510845Control Valve · faultyAFTER ENGINE ON RECALL ANNUNCIATOR PANEL DISPLAYED "AIR COND" WITH RIGHT PACK LIGHT ON CONSULTED QRH ON MASTER CAUTION RESET THE PACK LIGHT EXTINGUISHED. NR 2 TEMP CONTROLLER SHOWS THIS PACK TCV FAULT. INSTALLED NEW TEMP CONTROL VALVE REF MM 21 51 10. PERFOSDR ASAA11510854Unknown · malfunctionedON PREFLIGHT START VALVE C/B OPEN. RESET C/B REF MM 20 60 01. NR 1 ENGINE START VALVE OPS CK GOOD REF MM 80 11 03.SDR ASAA11510849Coupler · faulty40 MIN INTO FLT AFTER ENTERING CLASS II NAV BUT PRIOR TO ETOPS AIRSPACE MADE POSITION REPORT NORMALLY ON HF1 RECEIVED SELCAL CHECK BUT COULD NOT RESPOND TO ATC. DISCOVERED THAT WE COULD NOT TRANSMIT ON HF OR VHF COMMS 1 OR 2 USING BOOM MIC OR HANDHELD MIC AT SDR ASAA11510847Unknown · malfunctionedZONE TEMP LIGHT ILLUMINATED AFTER T/O. LIGHT EXTINGUISHES WITH MASTER CAUTION RESET. BITE SHOWS FLT DK ZONE VALVE. RESET AND REVERIFIED FAULT DID NOT RETURN.SDR ASAA11510844Unknown · malfunctionedCONTROL CABIN ZONE TEMP LIGHT ILLUMINATES ON RECALL. EXTINGUISHES ON RESET. BITE OF NR 2 PZTC SHOWS CONT CAB TRIM VALVE FAULT RESET & RETESTED PZTC REF FIM TASK 21 62TSK 842 NO FAULTS NOTED. SUCCESSFUL GROUND VERIFICATION CONFIRMED.SDR ASAA11510855Bleed Valve · failedON CLIMBOUT DUCT PRESSURE DIFFERENTIAL 22 PSI (R50PSI LT28PSI) CRUISE DIFFERENTAIL PRESSURE (10PSI RT40PSI LT 30PSI) A/C PRESSURISED NORMALLY. ACFT GROUNDED. ACCOMPLISHED LT ENGINE BLEED AIR SYSTEM HEALTH CHECK PER MM 36-11-00. FOUND BLEED AIR REGUALATOR ANSDR ASAA11510852Sensor · defectiveAPU OIL QTY READ AT CDU READS LOW APU OIL QTY AT TANK IS FULL. REPLACED APU OIL LEVEL SENSOR REF 49 94 11, GROUND OPS CK VERIFICATION GOOD.SDR ASAA11510848Unknown · malfunctionedCAPT FD AMBER FLAG DISPLAYS. FOUND FCC A DC C/B OUT. INSPECTED & RESET C/B REF MM 20 60 01 FCC A OPS CK OK REF MM 22 11 33.SDR ASAA11510846Duct · separatedON GROUND FLIGHT DECK TEMP CONTROLLER WILL NOT SUPPLY COLD AIR TO FLIGHT DECK. FULL COLD SELECTION ONLY SENDS 31 C AIR SUPPLY DUCK. FOUND DUCT CLAMP OFF AND DUCT SEPARATED AT RECIRCULATION FAN LEFT A/C BAY. CLAMP DAMAGED. DUCT ASSY GOUGE AT FLANGE NECK IS SDR ASAA1150850Idg · failedNR 1 IDG LIGHT NOT ILLUMINATED WITH ENGINE OFF. REPLACED IDG REF AMM 24 11 11 OPERATIONAL TEST FOR NR 1 IDG GOOD REF AMM 24 11 10.SDR ASAA1150853Start Valve · failedNR 1 ENG START VALVE WOULD NOT OPEN. NO ROTATION OR VALVE OPEN LIGHT. REPLACED NR 1 ENG START V/V PER MM 80 11 03, OPS OK. GROUND VERIFICATION GOOD.SDR ASAA11510851Unknown · malfunctionedON PREFLIGHT FO NOTED WING ANTI ICE VALVE C/B POPPED OUT. INSPECTED C/B PANEL & VALVE. NO DEFECT NOTED. RESET C/B REF AMM 20 60 01 PROCEDURE. OPS CHECK NORMAL REF AMM. 30 11 00. GROUND VERIFICATION GOOD.SDR ASAA1150839Unknown · malfunctionedL ENG ANTI ICE "BLUE" LIGHT BULB BURNED OUT. FOUND LT ENG CWL ANTI ICE VLV C/B A 7 OPEN. VISUALLY INSP CWL ANTI ICE VLV C/B BEHIND PANEL. NO DEFECT NOTED. RESET C/B IAW AMM TASK 20 60 01 860 801. TESTED LT ENG CWL ANTI ICE IAW AMM TASK 30 21 00 710 801. SDR ASAA2011122050843Valve · malfunctionedAIR CONDITIONING DUCT PRESSURE SPLIT OVER 20PSI. LEFT 50 RIGHT 29 PSI. ACCOMPLISHED NR 2 ENGINE BLEED AIR SYSTEM HEALTH CHECK IAW AMM 36-11-00-700-801. NR 2 ENGINE HIGH STAGE VALVE AND PCCV FAILED. HIGH STAGE VALVE DID NOT MANUALLY OPEN AND CLOSE SMOOTHLY SDR ASAA11510835Unknown · malfunctionedFMC DISAGREE DISPLAYED ON GROUND. ACCOMPLISHED QRH PROCEDURE. MSG NO LONGER DISPLAYED. OPS NORMAL.SDR ASAA11510834Unknown · malfunctionedON TAXI OUT OF SAN WITH RECALL GOT A LEFT PACK AIR COND AND MASTER CAUTION LIGHT. ALL LIGHTS EXTINGISHED AFTER RESETTING THE MASTER CAUTION. COULD NOT DUPLICATE. LT TEMP CONTROLLER BITE CHECK LOGGED THIS PACK TCV FAULT BUT VERIFY WAS A GO RESET LT TEMP CONTSDR ASAA11510833Unknown · malfunctionedDURING TAXI OUT OGG "FMS DISAGREE" MESSAGE DISPLAYED ACCOMPLISHED QRH PROCEDURE FMS OPERATIONS RETURNED TO NORMAL. CURRENTLY NR 1 AND NR 2 FMS SYSTEM GROUND FUNCTIONAL TEST GOOD IAW AMM 34 61 00 SYSTEM READY FOR CONTINUED SERVICE.
Back to Boeing 737-890