Boeing 737-890
Service difficulty reports · 23,038
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '737890' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '737890' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR ASAA11510019Idg · failedNR 1 GEN SOURCE OFF LIGHT CAME ON IN FLIGHT WOULD NOT RESET / APU COVERED THE BUS. GCU 1 SHOWS IDG FAULT. REPLACED NR 1 ENG IDG PER MM 24 11 11 000 801 AND 24 11 11 400 801. PERFORMED OPERATIONAL TEST REF AMM 24 11 00 700 802. OPS CHECK GOOD.SDR ASAA11510017Battery · defectiveMAIN AIRCRAFT BATTERY INDICATED NR 2 AMPS 27 28 VOLTS FOR ENTERING FLIGHT (2 + 20 HRS). AUX BATT INDICATED 0 AMPS 27 VOLTS AND ALL OTHER ELECTRIC SYSTEMS ARE INDICATING NORMAL. REPLACED BOTH BATTERIES PER MM 24 31 11. INSTALLATION TEST GOOD PER MM 24 31 11.SDR ASAA11510018Unknown · malfunctionedCAPT "FD" FLAG DISPLAYED. CYCLED AC & DC POWER. CAPT'S "FD" FLAG CLEARED ACCOMPLISHED DFCS BITE AUTOTEST. SYS TEST PASSED. REF AMM TASK 22 11 00 810 801.SDR ASAA11510016Starter Gen · faultyAPU FAILS TO START. FAULT LIGHT ILLUMINATED. ACCOMPLISHED FIM TASK 49 40 TASK 806 FOUND FAULT CODE 49 41244 LOGGED. REPLACED APU STARTER GENERATOR PER M/M 49 41 21 SYSTEM, OPS CHECKS NORMAL.SDR ASAA11510015Actuator · failedRT RAM AIR DOOR ACTUATOR CONTINUES TO RUN. RAM AIR DOORS AT INTERMEDIATE POSITION. BLUE LIGHT OUT ON FLT DECK. REPLACED RT RAM AIR INLET ACTUATOR PER AMM 21 51 21. PERFORMED PACK/ZONE TEMP CNTRL. BITE TWO TIMES ON BOTH PACKS. NO FAULTS NOTED.SDR ASAA11510014Warning System · intermittentRT PACK LIGHT REMAINS ILLUMINATED ON RECALL RESETS W/MASTER CAUTION RESET. ACCMP FIM TASK 21 53 00 810 810. FAULT FOUND TO BE INTERMTTENT ON RT PACK. BITE CHECK FOUND TO BE CLEAR. NO FAULTS. GROUND CHECK OK.SDR ASAA1159989Filter Element · dirtyAPU OIL FILTER INDICATOR RED BUTTON EXTENDED. REPLACED APU OIL FILTER. RESET THE OIL FILTER INDICATOR BUTTON PER AMM 49 91 12.SDR ASAA1159988Ram Air Door · out of positionNR 2 RAM AIR DEFLECTOR DOOR FOR A/C IS IN IMPROPER POSTION. CYCLED ACFT POWER. NR 2 RAM DOOR RETURNED TO OPEN POSTION. PERFORMED PACK/ZONE BITE TEST PER M/M 21 61 00 700 806 002. TEST GOOD. OK FOR SERVICE.SDR ASAA1159991Control Panel · inoperativeAPU GENERATOR POWER NOT AVAILABLE. ACFT GROUNDED. REPLACED APU STARTER GENERATOR AS REQUIRED OPS CHECKED BAD. AIR PRESSURE WAS GOOD NO ELECTRICAL POWER. REF AMM 49-41-21-400-810. REPLACED REMOTE APU CONTROL PANEL REF MM 26-22-03. PERFORMED TESTS MM 26-22-00-73SDR ASAA1159992Fmc · inoperativeLEFT FMC INOP CDU BLANK. FMCS CDU BITE SHOWS LEFT CDU FAULTING ON MULTIPLE LEGS IN THE INFLIGHT FAULTS PAGE (LETTER 'B' SHOWN ON FLT LEGS). CONFIRMED NO DEFECTS ON CONNECTORS D2181, D3263, D3267 AND D2179A. CONFIRMED CONNECTOR D2181 GOT GOOD GROUND ON PINS 31SDR ASAA1159985Unknown · malfunctionedAUTOLAND TOUCHED DOWN APPX IN LINE WITH LEFT HASH MARK OF RUNWAY WHILE CORRECTING TO THE RIGHT. PERF'D DFCS CURRENT STATUS TEST REF AMM 22 11 00 NO FAULTS BUT FLIGHT FAULT REVIEW REVEALED BOTH A/P'S WITH "VOR/LOC BEAM ANOMALY DETECTED" DURING APPCH/FLARE. ACSDR ASAA1159976Drive Unit · failedWX RADAR FAIL LIGHT PWS FAIL & ANT SHOWED. REPLACED WX RADAR ANT DRIVE UNIT OPS CK GOOD REF AMM 34 43 11. OPS CHECK GOOD REF AMM 34 43 00.SDR ASAA1159979Accessory Unit · malfunctionedCAPT MCDU BLANK. DE PINNED CONN D3263 PINS L AND M NO DEFECTS. REPLACED BOTH PINS PRECAUTIONARY PER WDM 34 61 11 REF SWPM 20 74 11. REPLACED IFSAU PER MM 22 11 37. BOTH FMC CDU'S OP CHECK NORMAL. KEPT PWR ON A/C FOR APPROX 30 MIN'S WITH NO DEFECTS. RE-INSSDR ASAA1159975Hmu · faultedFMC/CDU BITE CK FAIL NR 1 ENG SHORT TIME FAULT OF 50 HRS MESSAGE NR 73 20341 THE VMF POSITION SIGNAL IS OUT OF RANGE. ACCOMPLISHED EEC BITE FAULT STILL ACTIVE EVERY LEG (73 20341 IS ONLY FAULT). REF FIM 73 25 803 STEP F.(4): TABLE 205 PIN 16 34 SHOWS OPEN. SDR ASAA1159974Display · inoperativeF/O MCDU INOP. REPLACED F/O MCDU PER AMM REF 34 61 01 400 802/34 61 01 000 802. OPS CHECKS GOOD.SDR ASAA1159971Unknown · malfunctionedDURING PREFLIGHT FOUND OPEN C/B ON P18 2 (B 10) "FMCS BITE DC". RESET C/B PER MM 20 60 01 REF WDM 34 61 22. TESTED FMC REF MM 34 61 00 710 801. TESTS OK. SUCESSFUL GROUND VERIFICATION.SDR ASAA1159970Unknown · malfunctionedFMC DISPLAY FROZEN. ACARS OPS OK. PER ENGINEERING REQUEST ACCOMPLISHED THE FOLLOWING. REMOVED FMC NR 1 AND DISCONNECTED CONNECTORS D3267 D3263 D45235P AND D5925J. WHILE SHAKING ACCESIBLE WIRE BUNDLES AND CHECKING PIN SECURITY AND TENSION VERIFIED GOOD CONTSDR ASAA1159973Precooler · failedSIGNIFICANT PNEUMATIC DUCT PRESSURE SPLIT DURING CLIMB UPON REACHING FL 350 THE GAP NARROWED. EN ROUTE THE RIGHT DUCT PRESSURE WAS STEADY AT 42 & THE LEFT FLUCTUATED BETWEEN 22 PSI AND 37 PSI. FURTHER NOTE: DURING DESCENT (IDLE POWER) MATCHED VALUES AT 20/2SDR ASAA1159972Unknown · malfunctionedAFTER PUSHBACK FMC DISAGREE LIGHT ILLUMINATED. QRH PROCEDURE COMPLETED, OPS NORMAL.SDR ASAA1159968Sensor · failedRIGHT SIDE WINDOW OVERHEAT OCCURED PERFORMED QRH PROCEDURES WENT OUT AFTER 3 MINS WITH SWITCH OFF THEN BACK ON, NORMAL OPS. PERFORMED WHCU BITE PROCEDURE FOUND RT SIDE SENSOR FAULT. DUE TO HISTORY MOVED FROM MAIN SENSOR TO ALT SENSOR (LOWER POST). PERFORMEDSDR ASAA1159967Sensor · faultyAPU GENERATOR KICKED OFF BUS. ACCOMPLISHED FIM TASK 49 60 00 810 817 SPEED SENSOR 1 OR 2 SHOWS CIRCUIT FAILURE. FOUND NUMEROUS FAULTS ON NR 1 SPEED SENSOR. REPLACED SPEED SENSOR PER M/M 49 61 21. GROUND VERIFICATION CHECKS GOOD.SDR ASAA1159966Unknown · malfunctionedDURING ENGINE START WITH APU RUNNING AND ON APU GENERATOR POWER THE APU GENERATOR KICKED OFF BOTH SIDES BUT CONTINUED TO RUN. AFTER ENGINE NR 1 WAS STARTED APU GENERATORS WERE SUCCESSFULLY PUT BACK ON BOTH SIDES HOWEVER EEC ON ENGINE NR 1 WAS IN ALTN MODE. NSDR ASAA1159965Filter · unserviceableNR 1 ENG IDG FILTER BYPASS POPPED DPI SCAVENGE FILTER. CK IDG FILTER NR 1 ENG FOUND NO DEFECTS REF MM 24 11 00 810 803 FIM REPLACED IDG FILTERS REF MM 24 11 41 REPLACED OIL IDG MM 12 13 21 MOTORED NR 1 ENG FOR LEAK CHECK REF MM 71 11 02, OPS NORMAL.SDR ASAA1159969Transceiver · failedON PREFLIGHT WXR RADAR/PWS FAIL. DUPLICATED DEFECT. REPLACED WXR RECEIVER/TRANSMITTER REF MM 34 43 41, OPS CHECK NORMAL.SDR ASAA1159964Actuator · failedNR 1 ENGINE WOULD NOT START, NO F/F. NR 1 FUEL SPAR VALVE LIGHT REMAINS CONSTANTLY ON SPAR VALVE NOT OPENING. REPLACED NR 1 SPAR VALVE ACTUATOR IAW AMM 28 22 11 000 804 AND 28 22 11 400 804 OPS CHECK GOOD IAW AMM 28 22 00 710 801.SDR ASAA1159938Control Valve · failedON CLIMBOUT DUCT PRESS INDICATED L=18/R=40 PSI. CYCLED ENG AND WING HEAT ON/OFF WHICH CAUSED LEFT DUCT PRESS TO DROP TO 12 PSI W/A/I ON THEN BACK TO L23/R40. 3:51 HR/MIN INTO FLT DUCT PRESS STABLE AT L25 PSI/R42 PSI. PERFORMED LT ENG BLEED AIR HEALTH CHECK MSDR ASAA1159936Unknown · malfunctionedFMC DISAGREE DISPLAYED. ACCOMPLISHED FMC DISAGREE QRH CHECKLIST FMC DISAGREE MESSAGE NO LONGER DISPLAYED.SDR ASAA1159934Unknown · malfunctionedFMC DISAGREE MESSAGE DISPLAYED AND FMC DISAGREE LIGHT ILLUMINATED DURING TAXI. QRH PROCEDURE CLEARED MESSAGE LIGHT REMAINED OUT.SDR ASAA1159935Unknown · malfunctionedAUTO THROTTLES WILL NOT REMAIN ENGAGED. PERFORMED A/T BITE TEST FOUND F/C 22 31687 ASM NR 1 PER FTD 22 039 AND MT 22 039 CYCLED CB FOR AUTOTHROTTLE DC1. PERFORMED A/T SERVO MOTOR AND CURRENT STATUS TEST NO FAULTS. ALSO TORQUE MOTOR TEST NO FAULTS.SDR ASAA1159933Bleed Air Sys · malfunctionedNO APU DUCT PRESSURE APU RUNNING NORMAL EGT 400 DEG. ACCOMPLISHED INITIAL EVALUATION & APU BITE PROCEDURES PER FIM 49 55 00 801 804 E (1) PGS 1 3 & 49 60 00 810 801 NO DEFECTS FOUND. INSPECTED BLEED AIR VALVE AREA NO LEAKS FOUND & CONNECTOR IS TIGHTENED & SESDR ASAA1159930Overheat Loop · out of toleranceCLIMBING THRU 3000FT AGL NR 1 ENGINE OVERHEAT LIGHT ILLUMINATED. ENGINE NR 1 INDICATIONS WERE NORMAL. FOLLOWED QRH PROCEDURES LIGHT STAYED ON WITH THE THROTTLE AT IDLE. SHUT NR 1 ENG DOWN & LIGHT STAYED ON. PULLED FIRE HANDLE & LIGHT WENT OUT. RETURNED WISDR ASAA1159924Unknown · malfunctionedON PRE FLIGHT WINDOW HEAT RIGHT SIDE ON LIGHT NOT ILLUMINATED. CYCLED SWITCH LIGHT CAME ON. C/W WINDOW HEAT CONTROL TEST PER FIM TASK 30 41 00 810 801. RESET FAULT OPS CHECK NORMAL AT THIS TIME.SDR ASAA1159918Control Valve · failedAFTER ENGINE START OBSERVED A AIR CONDITIONING MASTER CAUTION ON RECALL WITH A RIGHT PACK LIGHT. RIGHT PACK/ZONE TEMP CONTROLLER LOGS "TCV THIS PACK" FAULT. REPLACED RIGHT TCV V141 REF MM 21 51 10. TCV INSTALLATION TEST GOOD PER SAME.SDR ASAA1159920Fuel/Oil Cooler · leakingFOUND FUEL LEAKING FROM FUEL / OIL HEAT EXCHANGER DRAIN LINE ON NR 1 ENGINE. NUMBER ONE ENGINE MAIN OIL / FUEL HEAT EXCHANGER DEFERRED FOR 75 CYCLES REF AMM 71 71 00 200 801 PARA F (1)(B)1. LEAKAGE RATE IS 10 DROPS PER MINUTE WITH ENGINE RUNNING AND NO LEAKASDR ASAA1159919Unknown · malfunctionedF/O FMC/CDU WENT BLANK FOR 10 SECS THEN CAME BACK ON. ONCE IN FLIGHT ONCE ON GND. OPS NORMAL WHEN IT CAME BACK ON. F/O FMC FFR SHOWS 1 MCDU FAULT. REMOVED & LIFTED F/O CDU KEYBOARD & INSPECTED FOR SECURITY NO FAULT FOUND. RE-INSTALLED F/O CDU KEYBOARD. ASDR ASAA1159922Shim · wornNR 2 ENG FAN BLADES SHIMS WORN. REPLACED 24 FAN BLADE SHIMS MFG P/N 340 252 307 0. REF TC 78472002.SDR ASAA1159913Wire Harness · defectiveNR 1 ENGINE TREND DATA SHOWS GREATER THAN NORMAL VIBRATION DATA SCATTER FROM THE FORWARD (NOB) SENSOR. ACCOMPLISHED AVM SYS OPS TEST NO FAULTS LOGGED BEFORE AND AFTER HARNESS CHANGED. REPLACED ENGINE NACELLE WIRING HARNESS MW0313 REF MM 71 51 03 000/400 801 SDR ASAA1159916Bleed Air Sys · malfunctionedZERO DUCT PRESSURE WHEN APU BLEED SWITCH SWITCHED ON. STARTED APU AND PERFORMED BLEED AIR VALVE OPERATIONAL CHECK OPS CHECK NORMAL IAW AMM 49 52 11 400 801 STEP F APU BITE TEST SHOW NO MAINTENANCE MESSAGE THERE WAS AN INTERMITTENT FAULT OK FOR SERVICE REF FIMSDR ASAA1159917Wire Harness · brokenDURING ENG FIRE TEST LIGHTS IN FIRE SWITCH HANDLE NR 2 FAILED TO ILLUMINATE. PERFORMED ENG/APU FIRE DET CONT MODULE BITE TEST PER FIM 26 10 TASK 801. FAULTED NR 2 ENG LOOP B UPPER FAN DETECTOR. FOUND WIRE AT UPPER FAN DET BROKEN OFF TERMINAL. RE-TERMINATEDSDR ASAA1159915Unknown · malfunctionedTR 3 CIRCUIT BREAKER OUT. FOUND TR 3 DC IND C/B ON P 5 OUT. ACCOMPLISHED C/B RESET PROCEDURE REF AMM 20 60 01. GROUND OPS VERIFICATION CHECKS GOOD REF AMM 24 32 11.SDR ASAA1159914Unknown · malfunctionedTRIM AIR PRESSURE CIRCUIT BREAKER IS POPPED OUT. RESET C/B REFERENCE AMM 20 60 01. PERFORMED BITE CHECK OF BOTH TEMP CONTROLLERS NO FAULTS LOGGED 21 62 00. OPERATED TRIM AIR NO FAULTS NOTED NO HISTORY FOR 30 DAYS.SDR ASAA1159921Shim · wornCOATING ON NR 2 ENGINE INLET SPINNER CONE MISSING COATING 24 FAN BLADE PLATFORM SEALS TORN 24 FAN BLADE SHIMS MISSING COATING. REPLACED ENGINE INLET SPINNER CONE PER T/C 78472002 STEP 7, 24 FAN BLADE PLATFORMS P/N 340 001 816 0 INSTALLED PER T/C 78472002 STEPSDR ASAA1159912Connector · malfunctionedCAPT FMC DISPLAY BLANK. FMCS CDU BITE SHOWS LEFT CDU FAULTING ON MULTIPLE LEGS IN THE INFLIGHT FAULTS PAGE (LETTER 'B' SHOWN ON FLT LEGS). CONFIRMED NO DEFECTS ON CONNECTORS D2181, D3263, D3267 AND D2179A. CONFIRMED CONNECTOR D2181 GOT GOOD GROUND ON PINS 3SDR ASAA1159907Screw · out of positionNR 2 ENGINE TREND DATA SHOWS A SUDDEN INCREASE IN LOW PRESSURE ROTOR VIBRATION LEVELS AFTER LAST FAN LUBE. DATA SCATTER INDICATES HARDWARE INSPECTION AND FAN RELUBE REQUIRED. C/W TASK CARD PERFORMED ON BOARD TRIM BALANCE AND VIBRATION SURVEY. POSITION NR 2 SDR ASAA1159906Sensor · failedAPU AIR SHUT OFF WITH SWITCH IN THE ON POSITION NO OTHER INDICATIONS OF ABNORMAL AIR SYSTEM. RAN APU W/ FULL LOAD ON ELEC & AIR BOTH PACKS ON. APU BLEED SW. OPS NORMAL W/ GOOD INDICATIONS. TSR ISSUED. REPLACED APU TOTAL PRESSURE SENSOR PER AMM 49 52 32 OPS SDR ASAA1159899Ring · damagedNR 1 ENG RING CONNECTING OIL CAP TO LANYARD IS DAMAGED. REMOVED AND REPLACED LANYARD RING ASSY, OPS NML.SDR ASAA1159898Antenna · defectiveRADAR IS SPOKING ALL QUADS IN CAL MODE IN WX T. UNABLE TO DUPLICATE. NO HISTORY LAST 30 DAYS. REPLACED WXR RADAR ANTENNA PRECAUTIONARY REF MM 34 43 11. OPS NML REF SAME.SDR ASAA1159897Unknown · malfunctionedLEFT PACK LIGHT ON RECALL, CLEARS WITH MASTER CAUTION RESET. PERFORMED PACK/ZONE TEMP CONTROLLER BITE PER FIM 21 62 00 810 801. INIT FAULT THIS PACK TCV. FAULT CLEARED. RE-RAN BITE. NR 1 & AT PACK TEMP CONTROLLERS BOTH "GO".SDR ASAA1159896Unknown · malfunctionedDURING CLIMB AUTOTHROTTLES DISENGAGED. PRIOR TO DISENGAGING NR 1 THROTTLE INCREASED N1 BY 1.8 PERCENT. FOUND MSG22 31688 ASM 2 IN FAULT HISTORY PAGE. ACCOMPLISHED FIM TASK 22 32 00 810 819. VERIFIED A/T BITE TORQUE TESTS ARE SATISFACTORY AND NO FAULT MSG PSDR ASAA1159893Bleed Air Sys · malfunctionedAFTER SHUTDOWN ATTEMPTED TO APPLY AIR CONDITIONING WITH APU INITIALLY. APU BLEED AIR SWITCH APPEARED NOT TO WORK. NO AIR WITH APU BLEED SWITCH ON. PERFORMED CURRENT STATES BITE NO FAULTS NOTED AND A FAULT HISTORY BITE NO FAULTS FOUND AND A MAINTENANCE HISTO
Back to Boeing 737-890