Boeing 737-890
Service difficulty reports · 23,038
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '737890' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '737890' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR ASAA0954967Control Valve · faultyZONE TEMP LIGHT ILLUMINATED ON CONT CABIN DURING MASTER CAUTION RECALL LIGHT EXTINGUISHES WHEN MASTER CAUTION SYSTEM IS RESET. ACCOMP PACK/ZONE TEMP. CONTROLLER BITE PROCEDURE FOUND FAULT LIGHT FOR FLT DECK TRIM VALVE ON NR 2 TEMP CONTROL AND NR 1 HAD NO FAULSDR ASAA0954939Stringer · damagedSTR 25R HAS THREE OVERSIZED HOLES. REMOVED & REPLACED DAMAGED SECTION OF STR PER SRM 53 00 03 REPAIR 1.SDR ASAA0954895Shim · damagedNR 1 ENG REF T/C 78472002 FOUND BLADE SHIMS MISSING MORE THAN 25 PERCENT OF MOLYDAG COATING REF MM 72-21-02-200-801-F00. SHIMS NIS SEA DEFERRED FOR 250 CYCLES IAW MM 72-21-02-200-801 SEAMC NOTIFIED.SDR ASAA0954894Paint · missingREF T/C 78472002 STEP 6 NR 1 ENGINE FRONT SPINNER CONE IS MISSING MORE THAN 20 PERCENT OF WHITE ANTI EROSION PAINT. REPLACED FRONT SPINNER CONE IAW T/C 78472002.SDR ASAA0954889Fitting · damagedSTR 25R HAS ELONGATED HOLE IN STR END FITTING. REPLACED STR END FITTING.SDR ASAA0954856Pcu · intermittentELEC LIGHT ON OVERHEAD PANEL IS ILLUMINATED. PERFORMED FIM TASK 24 31 00 810 801 FOUND INTERMITTENT FAULT ON SPCU. CLEARED FAULT, ALL CHECKS GOOD.SDR ASAA0954855Outflow Valve · malfunctionedAUTO PRESSURIZATION FAIL SWITCHED TO ALT. FOUND FAULT ON CABIN PRESS CONT NR 2 FLIGHT LEG OO CODE O78 OFU LRU FAIL 38214. VERIFIED P/N 4063 19972 01AA WITH SEAMC. REMOVED AND REPLACED AFT OUTFLOW VALVE REF MM 21 31 03 19382. DFPC BITE TEST GOOD, PRESSURIZASDR ASAA0954854Apu · leakingAPU IS LEAKING OIL FROM THE DRAIN MAST CAUSING A PUDDLE ON THE GROUND & IS 1 QUART LOW. PERFORMED DRAIN MAST INSPECTION REF MM 49 16 11 200 801 RAN APU FOR 10 MINS & MIDDLE DRAIN IS LEAKING OIL (LOAD COMPRESSOR SEAL). REPLACED APU REF AMM 49 11 00.SDR ASAA0954804Floor Panel · corrodedAFT CARGO BAY NR 5 FLOOR PANEL CORROSION. REMOVED AND REPLACED WITH NEW FABRICATED FLOOR PANEL.SDR ASAA0954806Floor Panel · corrodedAFT CARGO BAY NR 3 FLOOR PANEL CORROSION. REMOVED AND REPLACED WITH NEW FABRICATED FLOOR PANEL.SDR ASAA0954805Floor Panel · corrodedAFT CARGO BAY NR 4 FLOOR PANEL CORROSION. REMOVED AND REPLACED WITH NEW FABRICATED FLOOR PANEL.SDR ASAA0954803Floor Panel · corrodedAFT CARGO BAY NR 2 FLOOR PANEL CORROSION. REMOVED AND REPLACED WITH FABRICATED NEW FLOOR PANEL.SDR ASAA0954802Floor Panel · corrodedAFT CARGO BAY NR 1 FLOOR PANEL CORROSION. REMOVED AND REPLACED WITH NEW FABRICATED FLOOR PANEL.SDR ASAA0954828Fmc · malfunctionedFMC R FAILED SELECTED FMC BOTH ON LEFT F/O'S DISPLAY RETURNED TO NORMAL. FMC NR 2 CHECKS GOOD REF MM 34 36 01 NO RECENT HISTORY, OPS NORMAL.SDR ASAA0954781Frame · crackedBS 1088 FRAME LOWER CHORD CRACKED. REPAIRED PER ER 09-2021 & EA 800-53EA-00963.SDR ASAA0954762Threshold · crackedFWD CARGO BAY DOOR CUTOUT FWD CORNER THRESHOLD IS CRACKED. REMOVED AND REPLACED WD CARGO BAY DOOR CUTOUT FWD CORNER.SDR ASAA0954761Threshold · crackedFWD CARGO BAY DOOR CUTOUT AFT CORNER THRESHOLD IS CRACKED. REMOVED AND REPLACED FWD CARGO BAY DOOR CUTOUT AFT CORNER THRESHOLD.SDR ASAA0954764Floorbeam · corrodedAFT CARGO FLOORBEAM AT BS 727I+4 RBL 8. REPAIRED AFT CARGO FLOOR BEAM AT BS 727I+4 RBL 8SDR ASAA0954767Floorbeam · corrodedAFT CARGO FLOORBEAM CORRODED AT BS 767+4 LBL 12. REPAIRED AFT CARGO FLOOR BEAM AT BS 767+4 LBL 12SDR ASAA0954766Floorbeam · corrodedAFT CARGO FLOORBEAM AT BS 727I+4 LBL 7. REPAIRED AFT CARGO FLOOR BEAM AT BS 727+4 LBL 7.SDR ASAA0954765Floorbeam · corrodedAFT CARGO FLOORBEAM AT BS 727I+4 LBL 3. REPAIRED AFT CARGO FLOOR BEAM AT BS 727I+4 LBL 3.SDR ASAA0954763Floorbeam · corrodedAFT CARGO FLOORBEAM AT BS 727I+4 RBL 2. REPAIRED AFT CARGO FLOORBEAM AT BS 727I+4 RBL 2.SDR ASAA0954760Floorbeam · corrodedAFT CARGO FLOORBEAM CORRODED BS 767+4 RBL 3. REMOVED AND REPLACED WITH NEW EXTRUSION ON AFT CARGO FLOORBEAM.SDR ASAA0954759Floorbeam · corrodedAFT CARGO FLOORBEAM CORRODED BS 767+4 RBL 2. REMOVED AND REPLACED WITH NEW EXTRUSION ON AFT CARGO FLOORBEAM.SDR ASAA0954758Floorbeam · corrodedAFT CARGO FLOORBEAM CORRODED BS 767+4 RBL 7. REMOVED AND REPLACED WITH NEW EXTRUSION ON AFT CARGO FLOORBEAM.SDR ASAA0954826Paint · missingNR 2 ENGINE FRONT SPINNER MISSING BLACK ANTI EROSION PAINT. REPLACEMENT OF NR 2 ENGINE FRONT SPINNER DEFERRED UNTIL NEXT C-CHECK PER MM 72 21 01 200 801, SEAMC NOTIFIED.SDR ASAA0954827Bleed Air Sys · malfunctionedUPON APU START AND SELECTION OF APU BLEED AIR ONLY RECEIVED 2 PSI ON DUCT PRESSURE GAUGE (OUTSIDE AIR TEMP 32 DEG AND SNOWING). ACCOMPLISHED FIM TASK 49 55 00 810 804 INITIAL EVALUATION CHECKED NORMAL. ACCOMPLISHED APU BITE PROCEDURE PER 49 60 TASK 801, NO FSDR ASAA0954824Relay · failedRT CENTER FUEL PUMP AUTO SHUTOFF TEST INOP DURING TC 78128007 W/O 19798. FOUND RT AUTO SHUT OFF RELAY R937 BAD. REPLACED R937 REF WDM 28 23 11. GROUND VERIFICATION CHECKS GOOD REF MM 28 22 00.SDR ASAA0954796Hf Comm · malfunctionedARINL REPORTED NR 1 HF RADIO XSMIESIONS BROKEN SWITCHED PRIMARY FREQ TO NR 2 HF RADIO REPORTED LOUD/CLEAR. NR 1 HF SWITCHED TO DATA MODE. TESTED NR 1 HF RADIO WORKS NML REF MM 23 11 00/501. VERIFICATION FLIGHT SUCCESSFUL. OPS NORMAL.SDR ASAA0954795Warning System · malfunctionedWHEN MASTER CAUTION RECALL CHECK ACCOMPLISHED RT "PACK" LT ILLUMINATED. LT EXTINGUISHED WHEN MASTER CAUTION PUSH TO RESET BUTTON PUSHED. TROUBLESHOT PER FIM 21 62 00 810 828. RT PACK TCV FAULT LIGHT CLEARS AFTER TEMP CONTROLLER BITE. PAC OPS NORMAL RT "PACSDR ASAA0954794Sensor · dirtyZONE TEMP LIGHT ILLUMINATED ON RECALL FOR CONT CAB LIGHT EXTINGUISHES ON MASTER CAUTION RESET GROUNDED YES. PERFORMED BITE TEST ON NR 1 AND NR 2 ZTC FOUND FLT DECK SENSOR FLAGGED ON BOTH CONTROLLERS. PERFORMED CLEANING OF SENSOR REF 21-61-10-100-801 REF BITE TSDR ASAA0954750Floor Panel · corrodedFWD CARGO BAY NR 1 FLOOR PANEL CORRODED ON UPPER SURFACE OUTBOARD EDGES. REMOVED FABRICATED REPLACEMENT PANEL AND INSTALLED.SDR ASAA0954749Floorbeam · corrodedAFT CARGO BAY FLOORBEAM CORRODED. REMOVED AND REPLACED FLOORBEAM.SDR ASAA0954754Shim · damagedWHILE ACCOMPLISHING FAN BLADE LUBE ON NR 1 ENG FOUND FAN BLADE SHIMS MISSING MOLYDAG COATING GREATER THAN 25 PERCENT REF MM 72-21-02-200-801-F00 PARA I (1)(A). 24 EA SHIMS P/N 340-252-307-0 ORDERED ON FR 16675. A CONTINUE IN SERVICE LIMIT OF 250 CYCLES IS PESDR ASAA0954756Control Unit · overspeedFVR UNSATISFACTORY APU OVERSPEED AT FL 390 AUTO SHUTDOWN INITIATED. REMOVED AND REPLACED APU FUEL CONTROL UNIT REF MM 49 31 11 000 801 AND 49 31 11 400 801 STEPS A THROUGH AND INCLUDING H(2) OF INSTALLATION. REMOVED AND REPLACED APU ELE CONT UNIT REF MM 49 6SDR ASAA0954748Splice · corrodedCORROSION ON FLOORBOARD SPLICE BS 887 RBL 21 LBL 21.SDR ASAA0954757Splice · corrodedCORROSION ON FLOORBOARD SPLICE BS 887 RBL 21 LBL 21. FABRICATED AND INSTALLED SPLICE.SDR ASAA0954774Servo · faultyAUTO THROTTLES INOP WILL NOT ENGAGE IN ANY MODE. REPLACED NR 1 AUTO THROTTLE SERVO MOTOR PER MM 22 31 91 400 801. OPS NORMAL.SDR ASAA0954755Sensor · malfunctionedAFTER LEVELING FL 340 APU OVERSPEED ILLUMINATED FOLLOWED BY A SHUTDOWN OF THE APU. DIVERSION TIME 83 MINUTES. PERFORMED APU BITE CHECK FOUND FAULT MSG 49 31014 (APU OVERSPEED SHUTDOWN). PERFORMED FIM 49 30 TASK 802. REMOVED AND REPLACED APU SPEED SENSOR P/SDR ASAA0954753Shroud · damagedPER TECH SVC REQUEST REINSPECT OF NR 1 ENG ABRADABLE SHROUD. FOUND DAMAGE TO BE OUT OF SERVICEABLE LIMITS REF AMM 72 24 02 200 801 STEP F (1) PARAGRAPH (E) 1A CUMULATIVE DAMAGE TO BE GREATER THAN 1.5 FOR A CIRCUMFENTIAL DEFECT. MIG 2 C 235588 INIT (02030) ABRSDR ASAA0954729Panel · damagedNR 7 SPOILER MID SPAN I/B END HAS VARIOUS AREAS OF DAMAGE. REMOVED & REPLACED NR 7 SPOILER PANEL.SDR ASAA0954730Support · corrodedCORROSION ON FLOOR TO SIDEWALL SUPPORT BS 727B+6-787 10 LBL 21. FABRICATED REPLACEMENT SIDEWALL SUPPORT AND REPAIR SPLICES AND INSTALLED AT BS 727B+6-787 10 LBL 21.SDR ASAA0954728Support · corrodedCORROSION ON FLOOR TO SIDEWALL SUPPORT AT BS 500I RBL 24 WL 156. REMOVED AND REPLACED FLOOR SUPPORT.SDR ASAA0954727Support · corrodedCORROSION ON FLOOR TO SIDEWALL SUPPORT AT BS 500D TO 500I. FABRICATED AND INSTALLED SUPPORT.SDR ASAA0954697Arm · chafedRIGHT WING T/E PROGRAM ROLLER ARM IS CHAFED BEYOND SRM LIMITS. REMOVED AND REPLACED ROLLER ARM.SDR ASAA0954695Scuff Plate · corrodedCORROSION OF CARGO DOOR CUTOUT SCUFF PLATE. REMOVED AND REPLACED SCUFF PLATE.SDR ASAA0954726Support · corrodedCORROSION ON FLOOR TO SIDEWALL SUPPORT. FABRICATED REPLACEMENT SUPPORT IAW SRM 53 60 53 AND INSTALLED.SDR ASAA0954694Cargo Track · corrodedCORROSION ON RT CARGO TRACK. REMOVED AND REPLACED RT CARGO TRACK.SDR ASAA0954696Support · corrodedCORROSION ON FLOOR TO SIDEWALL SUPPORT. REPAIRED SUPPORT.SDR ASAA0954699Computer · malfunctionedAFTER ENG START W/ENG GENERATORS ON THE BUSSES FLT CONTROL MASTER CAUTION LIGHT ILLUMINATED ON RECALL. SPD TRIM FAIL AND MACH TRIM FAIL LIGHTS ILLUMINATED ON OVERHEAD FD FLAG ILLUMINATED ON CAPTAIN'S EADI. AFCS SYS A WARN LIGHT (BAT) C/B POPPED ON P18 PANEL.
Back to Boeing 737-890