Boeing 737-8BK
Service difficulty reports · 662
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7378BK' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7378BK' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SCNA20140506070Floorboard · damagedAFT WET AREA FLOORBOARD JUST INSIDE R2 DOOR HAS ONE SCREW HOLE OUT OF PLACE. REMOVED, REPLACED AND RELOCATED INSERTS.SDR SCNA20140506069Intercostal · corrodedCRACKED INTERCOSTAL IN FWD CARGO RT BS 500G-500H. FABRICATED AND REPLACED INTERCOSTAL.SDR SCNA20140506058Floor Support · crackedPAX COMPARTMENT FLOOR SUPPORT RBL 45 BETWEEN BS 312 - 328 CRACKED AT BOTH THROUGH HOLES. R & R FLOOR SUPPORT.SDR SCNA20140506050Floor Support · crackedCABIN FLOOR SUPPORT LBL 46 BS 312-328 IS CRACKED. R & R FLOOR SUPPORT.SDR SCNA20140506065Support Angle · crackedAFT CARGO BAY BS 847, S25L FWD LWR BULKHEAD SUPPORT ANGLE HAS EVIDENCE OF 2 STRESS CRACKS. REMOVED DAMAGE. FABRICATED AND INSTALLED REPAIR.SDR SCNA20140506068Intercostal · corrodedDURING GVI OF FWD CARGO FOUND INTERCOSTAL BETWEEN BS 500C-500D AT RBL21 CORRODED. R & R INTERCOSTAL DUE TO CORROSION BEING OUT OF LIMITS.SDR SCNA20140512072Floor Panel · damagedFWD WET AREA FLOOR PANEL "A" HAS PEELING FIBERS. REPAIRED FLOOR PANEL.SDR SCNA20140506067Channel · crackedLEFT HAT CHANNEL CRACKED AT BS 540 AND BL 0. R & R LT HAT CHANNEL.SDR SCNA20140506066Channel · crackedRT HAT CHANNEL CRACKED AT BS 540 AND BL 0. R & R RT HAT CHANNEL.SDR SCNA20140506064Angle · damagedAFT CARGO BAY BS 767-787, S25R, TRANSITION ANGLE UPPER SURFACE HAS NUMEROUS AREAS WITH CORROSION AND 2 DEEP GOUGES. REMOVED CORROSION FOUND TO BE OUT OF LIMITS. NEW PART FABRICATED AND INSTALLED.SDR SCNA20140506063Angle · corrodedAFT CARGO BAY BS 767-787 S25L TRANSITION ANGLE UPPER SURFACE HAS NUMEROUS AREAS WITH CORROSION. R & R TRANSITION ANGLE.SDR SCNA20140506062Angle · corrodedAFT CARGO BAY BS 727F-727G, S25R TRANSITION ANGLE UPPER SURFACE HAS NUMEROUS AREAS WITH CORROSION. REMOVED, FABRICATED AND INSTALLED NEW TRANSITION ANGLE.SDR SCNA20140506059Floor Panel · damagedAFT WET AREA FLOOR PANEL HAS MISSING & DAMAGED POTTED INSERTS. REPAIRED FLOOR PANEL AND INSTALLED INSERTS.SDR SCNA20140512071Floor Panel · damagedAFT WET AREA FLOOR PANEL "H" HAS PEELING FIBERS. REPAIRED FLOOR PANEL.SDR SCNA20140506061Floorbeam · corrodedAFT CABIN WET AREA AFT GALLEY FRAME, BS 986.5 TOP SURFACE CORROSION ON FILLERS FOR EXISTING FLOORBEAM. REPAIR LOCATED AT RBL 30 OTBD TO ATTACH POINT AT MOP SILL. REMOVED CORROSION FOUND TO BE OUT OF LIMITS. REPAIRED BEAM.SDR SCNA20140506057Angle · corrodedFWD CARGO BAY AFT BS 500G-TO AFT BULKHEAD. LT TRANSITION ANGLE HAS CORROSION UPPER SURFACE NUMEROUS AREAS. REMOVED CORROSION, FOUND TO BE FOUND OUT OF LIMITS. REPAIRED DAMAGED SECTION.SDR SCNA20140506056Angle · delaminatedFWD CARGO BAY RT AFT BS 500H TO AFT BULKHEAD AT TRANSITION ANGLE HAS DELAMINATION CORROSION UPPER SURFACE. DAMAGE FOUND OUT OF LIMITS. R & R TRANSITION PANEL.SDR SCNA20140506055Angle · corrodedFWD CARGO BAY BS 500G-500H RT AT TRANSITION ANGLE HAS CORROSION ON UPPER SURFACE. REMOVED CORROSION AND FOUND BEYOND LIMITS. NEW TRANSITION ANGLE INSTALLED.SDR SCNA20140506054Angle · corrodedFWD CARGO BAY BS 500E-500F, RT AT TRANSITION ANGLE HAS CORROSION UPPER SURFACE. REMOVED CORROSION IS BEYOND LIMITS. INSTALLED NEW TRANSITION ANGLE.SDR SCNA20140506053Angle · corrodedFWD CARGOBAY BS 500D-500E RT AT TRANSITION ANGLE HAS CORROSION UPPER SURFACE. REMOVED CORROSION AND FOUND BEYOND LIMITS. INSTALLED NEW TRANSITION ANGLE.SDR SCNA20140506051Angle · corrodedFWD CARGO BAY BS 492-500, RT AT TRANSITION ANGLE HAS CORROSION AT NUTPLATE HOLE. R & R TRANSITION ANGLE.SDR SCNA20140506060Floor Support · corrodedAFT CABIN WET AREA, AFT GALLEY RT FWD MOUNT HAS CORROSION ON TOP SURFACE OF FLOOR SUPPORT AFT OF GALLEY MOUNT AFT OF BS 986.5. R & R FLOOR SUPPORT.SDR SCNA20140506052Web · corrodedFWD CARGO BAY BS 440-492, RT AT LWR DOOR CUTOUT SURROUND WEB HAS NUMEROUS CORRODED AREAS ON UPPER SURFACE. REMOVED CORROSION. FOUND TO BE OUT OF LIMITS. INSTALLED NEW WEB.SDR SCNA20140512073Window Frame · crackedPILOT AFT SIDE WINDOW NR 3 FRAME HAS HFEC CRACK INDICATION IN A BOLT HOLE AND COUNTERSINK FWD SIDE SECOND FROM BOTTOM. REPAIRED WINDOW FRAME CRACK.SDR SCNA20140506049Floor Panel · corrodedFWD CARGO NR 3 FLOOR PANEL UPPER SURFACE INBD AND OTBD HAS LIGHT CORROSION. REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS. NEW FLOOR PANEL FABRICATED.SDR SCNA20140506048Window Frame · crackedCO-PILOT SIDE, AFT SIDE WINDOW NR 3 FRAME HAS A HFEC CRACK INDICATION IN A BOLT HOLE AND COUNTERSINK. FWD SIDE SECOND FROM BOTTOM. REPAIRED CRACK ON RT NR 3 WINDOW.SDR SCNA20140506047Floor Panel · corrodedAFT CARGO NR 2 FLOOR PANEL HAS LIGHT CORROSION ON UPPER SURFACE INBD & OTBD SIDES. BLENDED AND FOUND TO BE OUT OF LIMITS. NEW FLOOR PANEL FABRICATED.SDR CA140327001Pin · corroded(CAN) DURING THE FIRST SCHEDULED 10 YEARS MLG REMOVAL FOR O/H, SEVERE CORROSION WAS NOTED TO LT TRUNNION PIN, PN 161A1188-3, PART WILL BE SCRAPPED. THIS IS A LIFE LIMITED PART.SDR SCNA20140130004Battery Pack · no testEMERGENCY LIGHTS AT RT OVERWING EXIT DOORS FAILED BATTERY PACK CAPACITY FUNCTIONAL CHECK. R & R BATTERY PACK.SDR SCNA20131120191Power Supply · unknownR & R FORWARD AREA POWER SUPPLY AND BATTERY PACK. OPS CHECK GOOD.SDR SCNA20131120190Engine · failedON TAKEOFF ROLL, ENGINES ABOVE 40 PERCENT NG, AUTOTHROTTLES JUST STARTING TO TAKE CONTROL, THERE WAS A BANG AND NR 2 ENGINE STARTED TO ROLL BACK. FLIGHT WAS UNDER 80 KTS AND THE CREW ABORTED THE TAKEOFF AND RETURNED TO THE GATE.SDR SCNA20131114189Battery Pack · inoperativeDURING FUNCTIONAL CHECK, FOUND RT SIDE ROW 14-21 ALONG WITH LT SIDE ROW 13-21, EMERGENCY LIGHTS FAILED CHECK. BATTERY PACKS REPLACED. OPS CHECKED GOOD.SDR SCNA20131111188Cover · missingEXIT LIGHT COVER MISSING. INSTALLED NEW COVER.SDR SCNA20131122194Floor Panel · corrodedAFT CARGO NR 3 FLOOR PANEL HAS LIGHT CORROSION ON BOTTOM & TOP ATTACH AREAS. FABRICATED FLOOR PANEL.SDR SCNA20131122193Floor Panel · corrodedAFT CARGO NR 2 FLOOR PANEL HAS LIGHT CORROSION ON LOWER SURFACE ATTACH AREAS. FABRICATED AND TREATED FLOOR PANEL.SDR SCNA20131024181Floor Support · crackedFS 540, BUTT LINE 0 FLOOR SUPPORT CRACKED. REMOVED FLOOR SUPPORTS AND INSTALLED NEW FLOOR SUPPORT.SDR SCNA20131025187Vapor Barrier · crackedDURING OTHER MAINTENANCE IN LT WHEEL WELL, FOUND VAPOR BARRIER CRACKED APPROX 14" LT STA 663.73, LBL 30. THIS WAS PREVIOUSLY REPAIRED WITH CRACK RUNNING THROUGH REPAIR AREA AND BEYOND. REPAIRED DAMAGE.SDR SCNA20131024183Floor Panel · brokenPASSENGER CABIN LT BS 360, FLOOR PANEL BROKEN. REPAIRED FLOOR PANEL.SDR SCNA20131025186Sill · corrodedPASSENGER CABIN FWD WET AREA LT BS 309.9 OF MOP SILL. R & R MOP SILL.SDR SCNA20131025185Web · corrodedWEB AT STRINGER 17L IS DENTED AT CENTER LIGHTNING HOLE AT BS 857. REPAIRED WEB.SDR SCNA20131024184Floorbeam · corrodedFLOORBEAM AT BS 986 HAS EVIDENCE OF CORROSION AROUND FASTENER HOLES OTBD OF LBL 36. REPAIRED FLOORBEAM.SDR SCNA20131024182Rib · crackedLT HORIZONTAL STAB L/E INTERNAL INBD RIB CRACKED. R & R RIB.SDR SCNA20130904113Keelbeam · crackedWHILE PERFORMING LOWER WING TO BODY FAIRING UNDER WING BOX INSPECTION, FOUND LT AIR CONDITIONING BAY, AFT BULKHEAD UPPER INBOARD CORNER 2ND RIVET OTBD OF KEEL BEAM HAS A CRACK FROM RIVET HOLE DOWN TO LOWER EDGE OF BRACKET.SDR SCNA20130904112Bulkhead · crackedWHILE PERFORMING WING CENTER SECTION, RT BODY TASKS, FOUND RT AIR CONDITIONING BAY, AFT BULKHEAD, UPPER INBD CORNER, 2ND RIVET OTBD OF KEEL BEAM HAS A CRACK THROUGH THE RIVET HOLE.SDR SCNA20130611106Slide · malfunctionedON ARRIVAL AT KCHO, L1 DOOR SLIDE DEPLOYED BUT DID NOT INFLATE. REMOVED AND REPLACED L1 ESCAPE SLIDE.SDR SCNA20130513097Sign · missingSEAT 13A MISSING EXIT SIGN. REPLACED 13A EMERGENCY EXIT SIGN. OPS CHECK GOOD.SDR SCNA20121005042Warning Light · illuminatedON TAKEOFF ROLL, RIGHT AFT OVERWING EXIT LIGHTS ILLUMINATED.SDR CA120713003Brake · damaged(CAN) DURING BRAKE REMOVAL, FOUND THE WHEEL HARD TO REMOVE. HAD TO FORCE THE WHEEL OFF THE BRAKE UNIT. UPON INSPECTION, FOUND NR 2 ROTOR DAMAGED AT SEVERAL POSITIONS AROUND THE ROTOR DRIVE KEY SLOTS. THE CLIPS THAT ARE FITTED TO TRANSFER THE TORQUE, DRIVE KESDR CA111229002Connector · chafed(CAN) DURING OPERATION EXPERIENCED THE CB FEEDING THE READING LIGHTS AT ROW 28-29-30/A-B-C POPPING. ON FURTHER TROUBLESHOOTING FOUND A WIRE AT CONNECTOR D11580 PIN #6 CHAFING AGAINST A BRACKET LOCATED BETWEEN PSUS AT ROW 29 & 30, CAUSING THE CIRCUIT BREAKER TOSDR CA111223005Manifold · cracked(CAN) FUEL DISCOVERED LEAKING FROM APU DRAIN MAST DURING DAILY CHECK. FOUND APU FUEL MANIFOLD CRACKED NEAR B NUT AT FUEL NOZZLE. DIGEST 737NG-FTD-49-05003, DESCRIBES THIS AS A KNOWN ISSUE WHICH IS UNDER INVESTIGATION. FUEL MANIFOLD REPLACED WITH NEW.
Back to Boeing 737-8BK