Boeing 737-8EH
Service difficulty reports · 154
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7378EH' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7378EH' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2022092906393Transmitter · inoperativeSHIP 3777 -FCNT/DE- DECLARED EMERGENCY DUE TO FLAP ASYMMETRY ON APPROACH. CORRECTIVE ACTION: PERFORMED FSEU BITE PROCEDURE. IDENTIFIED FAULT CODE 27-52260 (TE FLAP SNSR R). ALSO FOUND LEFT FLAP POSITION TRANSMITTER OUT OF RIG. REPLACED LT/RT FLAP POSITION TRANSDR DALA2022072105057Battery Pack · inoperative(LOG 9154866) DURING INSPECTION FOUND EMERGENCY LIGHTS INOP ON RT AFT SIDE AROUND ROW 23 THROUGH AFT SVC DOOR. R/R BATTERY PACK AT MODULE M1672 PER B737 AMM 33-51. OPS CK NORMAL.SDR DALA2022062304387Transmitter · failedSHIP 3775 - MISC/DE - DUE TO FLAPS LOCKED OUT ON APPROACH. ALTERNATE FLAPS USED TO EXTEND TO 15. CORRECTIVE ACTION: REPLACED LEFT FLAP POSITION TRANSMITTER. OPS CHECKS GOOD.SDR DALA2022032201865Not Reported · not reported(LOG 2162685) DURING INSPECTION FOUND RT MLG: FWD TRUNNION FITTING UPPER O/B BUSHING HAS CORROSION AT NON FLANGE END. REPAIRED PER B737 SRM 57-20-90.SDR DALA2022032201864Not Reported · not reported(LOG 2162684) DURING INSPECTION FOUND RT MLG: FWD TRUNNION FITTING UPPER I/B BUSHING HAS CORROSION AT NON FLANGE END. REPAIRED PER B737 SRM 57-20-90.SDR DALA2022021701051None · none(LOG 2123388) DURING INSPECTION FOUND CORROSION ON RH SIDE PLATE BTW STA 767 TO 787 AT AFT CARGO COMPARTMENT. C2.RH SIDE PLATE BTW STA 767 TO 787 AT AFT CARGO COMPARTMENT WAS REPLACED PER B737-800 SRM 51-40-02-0G.SDR DALA2022021701050None · none(LOG 2122933) DURING INSPECTION FOUND CORROSION ON WEB FROM 796 TO 847 AT AFT CARGO COMPARTMENT ENTRY. C2. WEB WAS REPLACED PER B737-800 SRM 51-40-02-0G.SDR DALA2022020700747None · none(LOG 2110372) DURING INSPECTION FOUND CORROSION ON FUEL TANK ACCESS DOOR 633 CB ,632AB, 532 BB ,532NB ,532DB,532MB. CORROSION ON FUEL TANK ACCESS DOOR 633 CB ,632AB,532 BB ,532NB ,532DB,532MB, WAS REMOVED PER B737-800 SRM 51-10-02.SDR DALA2022020700746None · none(LOG 2110359) DURING INSPECTION FOUND CORROSION AT ACCES DOOR 532QB. CORROSION ON FUEL TANK ACCESS DOOR: 532QB WAS REMOVED B737-800 SRM 51-10-02.SDR DALA2021112907297Battery Pack · inoperative(LOG 8083707) DURING INSPECTION FOUND 3 EA CABIN OVERHEAD EMERGENCY LIGHTS INOP. REPLACED PWR SUPPLY AND BATTERY PACK M2335 AND TESTED PER B737 AMM 33-51-06.SDR DALA2021092705778None · none(LOG 1960292) DURING INSPECTION FOUND LIGHTNING STRIKE DAMAGE FOUND BETWEEN STA 203.8 & 196.5, S-27L & S-27R. REPAIRED DAMAGE PER ERA 594343-14.SDR DALA2021091605550Web · corroded(LOG 1949816) DURING INSPECTION FOUND CORROSION AT THRESHOLD WEB FROM STA 440 TO STA 492.4 AT FWD CARGO COMPARTMENT. CORROSION LEVEL 2 THRESHOLD WEB FROM STA 440 TO STA 492.4 WAS REPLACED PER B737-800 SRM 51-40-02.SDR DALA2021091605549Plate · corroded(LOG 1948970) DURING INSPECTION FOUND CORROSION ON RH SIDE PLATE BTW STA 492 TO STA 500I AT FWD CARGO COMPARTMENT. RH SIDE PLATE FROM STATION 500A TO STA 500I AT FWD CARGO COMPARTMENT WAS REPAIRED PER B737-800 SRM 53-00-53-2R PROCEDURE 6 AND RH SHIELD FROM STASDR DALA2021091605548Intercostal · corroded(LOG 1948287) DURING INSPECTION FOUND CORROSION WITH OUT OF LIMIT ON RH INTERCOSTALS FROM STA 500A TO STA 500C AT FWD CARGO COMPARTMENT. INTERCOSTALS FROM STA 500A TO STA 500C AT FWD CARGO COMPARTMENT WERE REPLACED PER B737-800 SRM 51-40-02.SDR DALA2021091305433Plate · corroded(LOG 1943694) DURING INSPECTION FOUND CORROSION ON LH SIDE PLATE BTW STA 500C TO 500E AT FWD CARGO COMPARTMENT. SIDE PLATE BTW STA 500 C TO 500E AT FWD CARGO COMPARTMENT WAS REPAIRED PER B737-800 SRM 53-00-53-2R, REPAIR 6.SDR DALA2021091005359Support · corroded(LOG 1941364) DURING INSPECTION FOUND CORROSION ON LH SIDE PLATE-SUPPORT ZEE UPPER AND LOWER AREA FROM STA 742 TO 827 ALSO BARE SURFACE OF SIDEPLATE-SUPPORT ZEE AT AFT CARGO COMPARTMENT. SIDEPLATE-SUPPORT ZEE FROM STA 742 TO 827 WAS REPLACED PER B737-800 SRM 5SDR DALA2021091005357Support · corroded(LOG 1941520) DURING INSPECTION FOUND CORROSION ON RH SIDEPLATE-SUPPORT ZEE UPPER AND LOWER AREA FROM STA 727F TO 767 ALSO BARE SURFACE OF SIDEPLATE-SUPPORT ZEE AT AFT CARGO COMPARTMENT. RH SIDEPLATE-SUPPORT ZEE FROM STA 727F TO 767 WAS REPLACED PER B737-800 SSDR DALA2021091005356Support · corroded(LOG 1941360) DURING INSPECTION FOUND CORROSION ON LH SIDEPLATE-SUPPORT ZEE UPPER AND LOWER AREA FROM STA, 727F TO 767 ALSO BARE SURFACE OF SIDEPLATE-SUPPORT ZEE AT AFT CARGO COMPARTMENT.SDR DALA2021032601810Transmitter · inoperativeSHIP 3775 -MISC/DE- DUE TO FLAPS WON'T EXTEND PAST 10 DEGREES ON APPROACH. CORRECTIVE ACTION: PERFORMED FSEU BITE. FAULT CODE 27-52260 (TE FLAP SNSR R) RECORDED. REPLACED RT FLAP POSITION TRANSMITTER AND FLAP POSITION INDICATOR. OPS CHECKS GOOD. AIRCRAFT RETURSDR DALA2021031901567Sensor · inoperativeSHIP 3777 -MISC/DE- DUE TO FLAPS WILL NOT EXTEND ON APPROACH. CORRECTIVE ACTION: FSEU BITE CHECK FAULT CODE 27-52259 (TE FLAP SENSOR L) REPORTED. REPLACED LEFT FLAP POSITION SENSOR. OPS CHECKS GOOD. FOUND FLAP POSITION INDICATOR N54 BAD. REPLACED SAME. PERFORMSDR DALA2021021800956Acm · seizedSHIP 3776 -ATB- RETURNED TO JFK DUE TO SMELL THROUGHOUT THE CABIN ALONG WITH ASSOCIATED GRINDING NOISE THAT FOLLOWS THROTTLES. CORRECTIVE ACTION: FOUND LT ACM FROZEN. REPLACED SAME. FOUND PRIMARY HEAT EXCHANGER CRACKED. REPLACED SAME. DUE TO ACM DAMAGE SUSPECTSDR DALA2021011900349Battery · inoperativeDURING INSPECTION FOUND ALL EMERGENCY LIGHTS OUT AT OVER WING EMERGENCY EXIT ROWS. FOUND BATTERY AT ROW 17DEF INOPERABLE. REMOVED AND REPLACED BATTERY AT ROW 17DEF, PER 737 AMM 33-51-06 TEST OK.SDR DALA2021011900338Battery Pack · inoperativeDURING INSPECTION FOUND EMERGENCY LIGHTS OUT AT OVER WING EMERGENCY ROW. FOUND BATTERY AT ROW 17DEF INOPERABLE. REMOVED AND REPLACED BATTERY AT ROW 17DEF, PER B737 AMM 33-51-06 TEST OK.SDR DALA2021010800112Skin · damagedDURING LAYOVER IN ATL, GROUND DAMAGE WAS INCURRED TO THE FUSELAGE SKIN BETWEEN STA 888-927 AND STR 23R-24R. MAINTENANCE REPAIRED DAMAGE, PER ERA 589328-14.SDR DALA2021010800111Skin · damagedDURING LAYOVER IN ATL, GROUND DAMAGE WAS DISCOVERED ON THE FUSELAGE SKIN BETWEEN STA 900-915 AND STR 23R TO 24R. STRINGER STR 24R (P/N 147A3215-21) WAS ALSO DAMAGED. MAINTENANCE REPAIRED DAMAGE, PER ERA 589302-14.SDR DALA2021010700106Skin · damagedDURING LAYOVER IN ATL, GROUND DAMAGE WAS INCURRED TO THE FUSELAGE SKIN BETWEEN STA 888-927 AND STR 23R-24R. MAINTENANCE REPAIRED DAMAGE, PER ERA 589328-14.SDR DALA2020122104178Heater · damagedF/A SMELLED SMOKE AFT GALLEY. NO ODORS NOTED, REF FIM 21-00 806. SUSPECT AFT DOOR HEATERS. R & R AFT DOOR HEATER, PER B737 AMM 21-45-01. OLD HEATER HAD SIGNIFICANT FOD ON INLET SCREEN, PROBABLE CAUSE OF ODOR. RAN CONDITIONED AIR THROUGH NEW HEATER FOR 30 SDR DALA2020091803121Battery Pack · inoperativeDURING INSPECTION FOUND ROWS RT 10-15 EMERGENCY LIGHTS INOPERATIVE. REMOVED AND REPLACED BATTERY PACK M1676, IAW B737 AMM 33-51. OPS CHECK NORMAL.SDR DALA2020090802979Floor Support · corrodedDURING INSPECTION FOUND CORROSION ON INTERCOSTAL BTW STA Y=500B AND Y=500C LBL 24 AT FWD CARGO COMPARTMENT. INTERCOSTAL AT LBL 24 BTW STA Y=500B AND Y=500C FWD CARGO COMPARTMENT WAS REPAIRED PER ER/A 587652-14 REV. ORIGINAL. SECTION I PERMANENT REPAIR AND ETI-SDR DALA2020090842974Floorbeam · crackedDURING INSPECTION FOUND CRACK ON FLOOR SUPPORT STATION 540 RBL 2 AND LBL 2 AT PASSENGER COMPARTMENT. REPAIR WAS PERFORMED ON PANEL BRAKE SUPPORT STATION 540 PER ERA 587606-14 REV. A SECTION I AND ETI-37-20-318 REV 1.SDR DALA2020090532965Floorbeam · crackedDURING HCK AT QRO, WHILE PERFORMING A BASE ZONAL INSPECTION PER WC 5300-2342, SEVERAL CRACKS WERE FOUND AFFECTING PANEL BREAK DETAILS P/N 143A5240-33 & -34 AT STA 540 BTW RBL 24.75 - LBL 24.75, PERTAINING TO LOWER LOBE INTEGRATION INSTALLATION. DAMAGE WAS REPASDR DALA2020090102911Support · corrodedDURING INSPECTION FOUND CORROSION ON RH SHIELD PLATE FLOOR STRUCTURE SUPPORT FROM STA 767 TO STA 794.3 AT AFT CARGO COMPARTMENT. SHIELD PLATE FLOOR STRUCTURE SUPPORT FROM STA 767 TO STA 794. WAS REPLACED PER B737 -800 SRM 51-40-02 PAR 4 AND 5 AND DWGSDR DALA2020051302387Battery Pack · dischargedOVERHEAD EMERGENCY LIGHTS AT ROW 18 ABC AND 27 ABC ARE INOPERATIVE. REPLACED LIGHT BATTERY PACK M1670. SYSTEM OPERATION IS NORMAL.SDR DALA2020050502356Battery · dischargedFOUND EMERGENCY LIGHT BATTERY PACK M1673 INOPERATIVE. REPLACED BATTERY. SYSTEM OPERATION IS NORMAL.SDR DALA2020050502352Battery Pack · dischargedAFT ROW EXIT EMERGENCY LIGHTS AND LEFT ROW LIGHT INOPERATIVE DURING SERVICE CHECK. REPLACED BATTERY PACK. SYSTEM OPERATION IS NORMAL.SDR DALA2020041002235Battery Pack · discharged(LOG 6944429) EMERGENCY SEAT LIGHTS NOT TESTING AT ROWS 19 THRU 22. REPLACED EMERGENCY LIGHT BATTERY PACK AT SEAT 23 M16T1 PER B737 AMM 33-51. OPS TEST OK.SDR DALA2020041002234Charger · inoperative(LOG 6195421) EMERGENCY LIGHTS AFT LEFT DOOR INOPERATIVE. R/R CHARGER AND BATTERY PER B737 AMM 33-51-11. OPS CK NORMAL.SDR DALA2020040602183Control Valve · faulty3777 - DIV DIVERTING TO LAX DUE TO FLT DECK TEMP BEING HOT. MAINTENANCE REPLACED LEFT PARK MIX MUFF DUCT CLAMPS PER AMM 21-51. ALSO REPLACED TRIM AIR VALVE AND LEFT PACK TEMP CONTROL VALVE PER AMM 21-61.OPERATIONAL CHECK OK.SDR DALA2020022411361Battery Pack · inoperative(LOG 6669825) DURING INSPECTION FOUND EMERGENCY LIGHTS INOP AT L2 DOOR AND GALLEY. REMOVED AND REPLACED THE EMERGENCY LIGHT BATTERY PACK AT M1673. OPS NML REF B737 AMM 33-51.SDR DALA2020010300023Fuse · blown(LOG 6401400) DURING INSPECTION FOUND FWD GALLEY EMERGENCY LIGHT INOPERATIVE. REPLACED FUSE IN BATTERY PACK. NOW ALL E-LIGHTS CK GOOD. REF B737-800AMM 33-51.SDR DALA2020081312784Structure · damagedDURING INSPECTION FOUND AFT CARGO DOOR DAMAGE. DAMAGE WAS REPAIRED PER B737-800 SRM 52-30-01.SDR DALA2019082805051Light · inoperativeDURING INSPECTION FOUND EMERGENCY AISLE LIGHT ABOVE ROW 1 INOPERATIVE. REMOVED AND REPLACED EMER LIGHT ASSY ABOVE ROW 1 PER B717 AMM 33-22 OP CKS GOOD.SDR DALA2019051302996Chiller · malfunctioned(LOG 5768692) FLT CREW REPORTED AN ELECTRICAL SMELL COMING FROM FWD GALLEY NEAR CHILLER. REPLACED FWD GALLEY CHILLER PER AMM 25-31. OPS NORMAL.SDR DALA2019030301398Sign · inoperative(LOG 5768940) DURING INSPECTION FOUND 1R EMERGENCY EXIT SIGN INOPERATIVE. RPLCD SAME OPS CK GOOD IAW AMM 33-50.SDR DALA2019022501167Transmitter · inoperativeON APPROACH INTO SLC, LE FLAPS FAILED TO EXTEND. WE RAN THE QRH AND USED THE ALTERNATE FLAP SWITCH AND EXTENDED FC TO FLAPS 15. LANDING AT FL15 WAS UNEVENTFUL. REMOVED AND REPLACED LH FLAP POSITION TRANSMITTER AND FLAP POSITION INDICATOR PER B737 AMM 27-58. OPSDR DALA2019011800382Cargo Track · cracked(LOG 0908146) DURING INSPECTION FOUND CRACK TRACK RBBL 13.80 FROM BS727E TO BS767 AT AFT CARGO COMPARTMENT. PERFORMED PERMANENT REPAIR ON TRACK RBBL 13.80 FROM BS7270 TO BS787 AFT CARGO COMPARTMENT ASPER PRI 574418-14 REV.O, 1 AND ERA NO.574418-14.SDR DALA2019011800381Frame Splice · dented(LOG 0907627) DURING INSPECTION FOUND DENT FRAME SPLICE LOCATED STA 727H AND STR 24R TO STR 25R AT AFT CARGO COMPARTMENT. REPLACED FRAME SPLICE LOCATED STA 727H AND STR 24R TO STR 25R AT AFT CARGO COMPARTMENT AS PER SRM 51-10-02 ITEM 9 AND DRAWING #146A1242SDR DALA2019011600282Channel · dented(LOG 0905842) DURING INSPECTION FOUND DENTS ON FRAME CHANNEL LOCATED 500D BTW STR 25L TO STR 26L AT FWD CARGO COMPARTMENT. REPLACED CHANNEL LOC AT BS 500D BTW STR 18L AND STR 26L FWD CARGO COMPARTMENT AS PER SRM 51-10-02. ITEM 9. 51-40-02. AND DWG # 143A1225. SDR DALA2019011600281Intercostal · cracked(LOG 0905815) DURING INSPECTION FOUND CRACK WEB - INTERCOSTAL LOCATEB BTW STA 328 TO STA 344 AND LBL 45.5 AT FWD GALLEY AREA. THE REPLACEMENT OF WEB-INTERCOSTAL LOCATED BTW STA 328 TO 344 AND LBL 45.5 AT FWD GALLEY AREA IS TO BE ACCOMPLISHED AS PER MODIFICATIOSDR DALA2019012400526Intercostal · corroded(LOG 0905129) DURING INSPECTION FOUND CORROSION WEB - INTERCOSTAL BTW BST 767 TO BST 792 AND RBL 20 AT AFT CARGO COMPARTMENT. REPLACED WEB - INTERCOSTAL LOC BTW BODY STATION 767 TO BODY STATION 792 AND RBL 20 AT AFT CARGO COMPARTMENT AS PER SRM 51-10-02.
Back to Boeing 737-8EH