Boeing 737-8F2
Service difficulty reports · 209
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7378F2' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7378F2' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SCNA20260109018Guard · brokenEMERHENCY EXIT LIGHT SWITCH ON P5 PANEL BLACK GUARD BROKEN. SWITCH IS NOT CLOSING, PART NUMBER NOT ASSIGNED TO THIS ACFT. IPC SAYS IT IS. INSTALLED PART NUMBER B9985-1.SDR SCNA20260105003Lamp · inoperativeAFT L/H EXTERIOR OVERWING EXIT EMERGNECY LIGHT INOPERATIVE. REMOVED AND REPLACED AFT LT EXTERIOR OVERWING EXIT EMERGENCY LIGHT LAMP IAW AMM 33-51-04-960-801. OPS CHECK GOOD AT THIS TIMESDR SCNA20251229509Wire Harness · burnedFOUND WIRE HARNESS TO NR 2 ENG STARTER BURNED. REMOVED AND REPLACED WIRING HARNESS MW0312. REF AMM 71-51-03. WIRING HARNESS NEEDS OPS CHECKED PER SUBTASK 71-51-03-710-004-F00SDR SCNA20251226508Retainer · unsecureL1 ESCAPE SLIDE VERY LOOSE WHEN DISARMED AND GIRT BAR IS IN RETAINER CLIP. TIGHTENED L1 SLIDE GIRT BAR HOLDER REF AMM 25-61-06SDR SCNA20251226506Lens · deterioratedRIGHT FWD EMERGENCY EXIT DOOR ROW 15DEF LIGHT LENS DERIORATED.DECRATIVE PAINT CHIPPED. TOUCH UP PAINT LIGHT AT ROW 15 DEF IAW AMM 51-21-99.SDR SCNA20251226503Lens · deterioratedRIGHT FWD EMERG. EXIT DOOR LIGHT LENS DETERIATED IAW GMM/MTI MDDR #135854.SDR SCNA20251226501Bulb · inoperativeAFT CEILING EMERGENCY LIGHT INOPERATIVE. REPLACED AFT EMERGENCY CEILING BULB REF AMM 33-51-00SDR SCNA20251226500Bulb · inoperativeEMERGENCY LIGHT 10DEF FAILED. REPLACED 10DEF EMERGENCY LIGHT BULB REF AMM 33-51-00.SDR SCNA20251218495Lamp · inoperativeNO SMOKING LIGHTS INOP AT THE FOLLOWING SEAT LOCATIONS: 6D, 11D, 29D, 10A, 19A RELAMPED NO SMOKING LIGHTS 6D, 11D, 29D,10A,AND 19A REF AMM 33-25-00. OK FOR SERVICESDR SCNA20251215485Brake · contaminatedBOTH BRAKE SMOKING ON LANDING UP TO GATE. INSP NR 1 & 2 BRAKES IAW AMM 32-41-41. NO LEAKS NOTED, SUSPECT DEICING FLUID.SDR SCNA20251209468Light · unsecureROW 1A AND 13 ABC EMERGENCY EXIT PATH STRIP COMMING UP. SECURED THE LIGHT STRIP ON EXIT PATH LIGHT IAW AMM 33-14-00.SDR SCNA20251202457Trim Panel · damagedSHARP METAL TRIM NEAR 2L AFT LAV STICKING OUT. SECURED TRIM NEAR AFT LAV REF AMM 25-31-00. OK FOR SERVICE.SDR SCNA20251022400SCarpet · unsecureFORWARD ENTRY BASEBOARD CARPET IS PEELING OFF WALL, PLASTIC IS A TRIP HAZARD ( NON-ESSENTIAL EQUIPMENT AND FURNISHING (NEF) ) REMOVED AND REPLACED FORWARD ENTRY BASEBOARD CARPET AND KICKSTRIP PLASTIC REF CMM 25-26-18. THIS CLEARS MEL 25-10NSDR SCNA20251022400Carpet · peelingFORWARD ENTRY BASEBOARD CARPET IS PEELING OFF WALL, PLASTIC IS A TRIP HAZARD. OPENSDR SCNA20250919382Handle · unsecureLEFT FWD OVERWING EMERGENCY EXIT DOOR MAINT ASSIST STRAP MISSING TRIM RETAINING STUDS. SECURED THE LT FWD OVERWING EXIT DOOR ASSIST HANDLE TRIM ASSY. REF AMM 52-22-51.SDR SCNA20250917378Battery Pack · no test6-12ABC EMERGENCY AREA LIGHTS FAILED CAPACITY CHECK RETEST. PER AMM 33-51-06-200-801 STEP 5 REMOVED AND REPLACED AFT POWER SUPPLY BATTERY PACK REF: 31-51-06-960-805. EMERGENCY LIGHTS CHECK GOOD.SDR SCNA2025091500375Seat Track · out of limitsCOPILOT AFT OUTBOARD SEAT TRACK OUT OF LIMITS. REMOVED AND REPLACED COPILOT AFT OUTBOARD SEAT TRACK IAW B737 AMM 25-11-11-400-801SDR SCNA20250915375Window Frame · crackedCRACK NOTED R1 WINDOW FRAME UPPER OUTBOARD CORNER. REPAIR OF R/H #1 WINDOW FRAME WAS ACCOMPLISHED ON EA TASK CARD 737-53-1336-01-G3CFG1&2-R. 89773U 09/11/2025SDR SCNA20250908365Slide · no discrepancy1L DOOR SLIDE SAGS AND SEEMS TO MAKE A POPPING NOISE ON CLIMB OUT INSPECTED SLIDE PACK PER AMM 25-66-01 NO DEFECTS NOTED OK FOR SERVICE A&P 3353509SDR BJNA202509090001Battery Pack · dischargedRH AFT OVERWING EMERGENCY LIGHT (SLIDE LIGHT) INOPERATIVE. R & R POWER SUPPLY M1671 IAW AMM 33-51-06-960-806. SEE LOG PAGE 144200 FOR BATTERY REPLACEMENT AND OPS CHECK.. INSTALLED BATTERY IN M1617 POWER SUPPLY IAW AMM 33-51-06-960-805. R & R AFT OVERWING SLIDSDR SCNA20250904358Slide · out of positionCREW REPORTS L1 DOOR SLIDE FLAP HANGING LOW. RE-POSITIONED L1 DOOR SLIDE FLAP AND INSPECTED SLIDE LATCH REF AMM 25-66-01SDR SCNA20250903349Lens · detachedEXIT ROW EMER EXIT LIGHT MISSING FWD EXIT SIGN. FOUND LENS FOR EXIT LOCATOR SIGN IN COMPARTMENT, RESECURED AT OVERWING POSITION IN REF AMM 33-51-00. OKAY FOR SERVICE.SDR SCNA20250905362Window Frame · crackedL1 WINDOW FRAME CRACK - PERMANENT REPAIR - LH - - C/W BY ATS 80761C ACCOMPLISHED SB 737-53-1336 REV 1 DATED OCT 23, 2014SDR SCNA20250818324Battery Pack · inoperative2L EMERGENCY EXIT PLACARDS (TOP AND BOTTOM) AND FLOOR EXIT LIGHTING IN THE AFT CABIN DID NOT ILLUMINATE WITH AC POWER OFF. REMOVED AND REPLACED BATTERY PACK PER AMM 33-51-06.SDR SCNA20250811313Light · unsecureTHE EMERGENCY LIGHTING STRIP ON THE FLOOR IS NOT SECURED TO THE FLOOR ROW 12 & 13. RESECURED STRIP @ ROW 12 & 13 REF AMM 25-27-31. OK FOR SERVICE.SDR SCNA20250807303Power Supply · inoperativeROW 20 AND 22 DEF EMERGENCY ISLE LIGHTS INOPERAITVE. INTERIOR EMERGENCY EXIT LIGHTING SYSTEM; EMERGENCY AISLE LIGHTS. REMOVED AND REPLACED POWER SUPPLY M1671 REF AMM 33-51-06, OPS CHECK GOOD THIS CLEARS MEL.SDR SCNA20250807295Generator · trippedWHILE BOARDING APU GENERATOR KICKED OFF LINE. MANUALLY PUT GENERATOR BACK ON LINE. DISTINCT ELECTRICAL SMELL IN FLIGHT DECK CABIN. PERFORMED FUMES IN CABIN FIM 21-00 TASK 806 NO DEFECTS NOT AT THIS TIME A/C OK FOR SERVICESDR SCNA20250731288Retainer · out of adjustL1 GIRT BAR VERY LOOSE. ADJUSTED GIRT BAR RETENTION CLIPS AT L-1 POS. PER AMM 25-66-00SDR SCNA20250625229Retainer · looseL1 DOOR SLIDE GIRT BAR RETAINING LOOPS LOOSE IN COVER, REMOVED SLIDE IAW AMM 25-66-01 TO TIGHTEN RIVETS ON GIRT BAR RETAINING LOOPS IAW SRM 51-40-02. INSTALLED SLIDE IAW AMM 25-66-01.INSPECTED SLIDE WHEN ITS INSTALLED REF AMM 25-66-01.SDR SCNA20250616211Battery Pack · inoperativeFOUND EMERGENCY EXIT SIGNS AND LEFT ESCAPE SLIDE LIGHT IN FWD GALLEY INOP. - REMOVED AND REPLACED BATTERY PACK AT M1675 POWER SUPPLY. EMERGENCY LIGHS OPS CHECK GOOD.REF AMM 33-51-06.SDR SCNA20250613209Slide · detachedDEFECT 717847: F/A OPENED DOOR WITHOUT DISARMING SLIDE - SLIDE CAME OUT OF CAGE BUT DID NOT DEPLOY - RESOLUTION: REINSTALLED DOOR SLIDE AT 1L DOOR PER B737 AMM 25-66-01-400-801 REV 86 DATED 15 FEB 2025SDR SCNA20250612208Battery Pack · no testEMER BATTERY PACK FOR AFT SERVICE DOOR FAILED TEST - RESOLUTION: R&R EMER BATTERY PACK FOR AFT SERVICE DOOR REF AMM 33-51-06 OPS CHECK GOODSDR SCNA20250602186Smoke Detector · false activationWORK ORDER 95748: FWD F/A VISUAL ALERT LIGHT DOES NOT ILLUMINATE DURING LAV SMOKE DETECTOR TEST ( ALERTING SYSTEM (AUDIO/VISUAL); FLIGHT ATTENDANT VISUAL ALERTING SYSTEM ) - RESOLUTION: R/R FWD LAV SMOKE DETECTOR IAW AMM 26-14-01. OPS CHECK GOOD. THIS CLEARSSDR BJNA202505150001Battery Pack · faultedNOTED R1 DOOR EMERGENCY EXIT LIGHT INOP. FOUND POWER SUPPLY TO BE FAULTY. R/R EMERGENCY EXIT LIGHT POWER SUPPLY IAW AMM 33-51-06-960-806. SEE SUBSEQUENT ACTION FOR R/R OF BATTER AND OPS CHECK. CHARGER LOCATION M1674. R/R BATTERY PACK ASSY ON POWER SUPPLY IAWSDR SCNA20250505155Strap · corrodedFLOOR STRAP AT BS 1019 RBL 18 WL 208 HAS CORROSION - RESOLUTION: FOUND NO ALLOWABLE DAMAGE IN SRM, REPAIRABLE BY REPLACEMENT PER SRM 51-10-02-OG-0, STEP 9(C), REMOVED AND INSTALLED NEW FLOOR STRAP AT B.S. 1019, RBL18, WL208 PER SRM 51-40-02-OG-0, DWG 147A5700SDR SCNA20250505158Stringer · damagedWO 94518, TASK CARD ENG-53SCA-11445: N827SY - STRINGER 28R REPAIR BETWEEN BS 500B AND BS 500H - INSTALL - C/W FAS# 9230SDR SCNA20250425129Lens · damagedON WALKAROUND FOUND L1 DOOR EXTERIOR EMERGENCY EXIT LIGHT LENS PUSHED OUT & LIGHT INOP. - RESOLUTION: RELAMPED L1 DOOR EMERGENCY EXIT (SLIDE) LIGHT, CHECKS GOOD. REMOVED DAMAGED LENS.SDR SCNA20250505154Frame · crackedSTA 312 FRAME HAS A CRACK ON THE EDGE BETWEEN STR 5-6 LH - STA 312 FRAME REPAIRED IAW SRM 53-10-07-2R-1 BETWEEN STA 5-6 LHSDR SCNA202505052153Frame · crackedSTA 312 FRAME HAS A CRACK ON THE EDGE BETWEEN STR 5-6 LH - STA 312 FRAME REPAIRED IAW SRM 53-10-07-2R-1 BETWEEN STA 5-6 LH.SDR SCNA20250407101Fire Detector · false activationDEFECT 714466: EXPERIENCED 4 INNTERMITTENT , AFT CARGO FIRE ALERTS FROM 37,000 FT TO 8000 FT. LONGEST OF 10 SECOND DURATION. ALWAYS WENT OUT ON ITS OWN. - RESOLUTION: PERFORMED FIM 26-16 TASK 801 NO DEFECTS NOTED. REMOVED AND REPLACED AFT CARGO CEU IN REF. TSDR SCNA20250312073Light · inoperativeWORK ORDER 93797 N/R-00002: WHEN CHECKING EMERG LIGHTS PER TASK CARD #330100000, EMERG LINGTS REMAINED ON FOR 10 MIN OR LESS AT FWD ENTRY DOOR, AFT LH ENTRY DOOR , AFT GALLEY OVERHEAD LIGHT . - - RESOLUTION: (IN PROGRESS)SDR SCNA20250312072Light · inoperativeWORK ORDER 93797 N/R-00001: PER TASK CARD #330100000, EMERG LIGHTS DID NOT COME ON AT ROW 11 ABC, 18 ABC, 24ABC, 26 ABC, AND DEF ROW 4. - - RESOLUTION: (IN PROGRESS)SDR SCNA20250221059Slide · partial deployL1 DOOR SLIDE PARTIALLY DEPLOYED FROM SLIDE CANISTER. GIRT BAR WAS ARMED WHEN DOOR PARTIALLY OPENED. REF LOG PAGE 797561 ITEM 2 FOR SLIDE REPLACEMENT, REF 797561 - L1 DOOR SLIDE INSTALLED REF AMM 25-66-01 GOOD FOR SERVICESDR SCNA20250130035Latch · stuckDEFECT 797311: FORWARD ALLEY EMERGENCY CABINET EQUIPMENT DOOR LATCH STUCK. RESOLUTION: LUBED LATCH FWD GALLEY CABINET DOOR LATCH. OPS CK GOOD REF AMM 25-64-00.SDR SCNA20250128033Cover · brokenDEFECT 796983: 2L SLIDE HOUSING COVER BROKEN. RESOLUTION: REAPPLIED 2L SLIDE HOUSING COVER REF AMM 25-66-00 OK FOR SERVICESDR SCNA20250128032Window · arcedDEFECT 797038: DURING DECENT BRIGHT FLASH OF LIGHT FROM MIDDLE OF R1 WINDOW POSSIBLE ARC WITH OVERHEAT ANNUNCIATION ON OVERHEAD PANEL. REMOVED WINDOW REF AMM 56-11-11 R1 WINDSHIELD INSTALLED REF AMM 56-11-11. UP TO STEP H.(8). INSTALLED MESH , NALON CORN AND SDR SCNA20250116017Girt Bar · looseDEFECT 796963: 1R DOOR BRACKET FOR GIRT BAR LOOSE. RESOLUTION: FOUND DEBRIS IN GIRT BAR BRACKET AND ON GIRT BAR REMOVED CLEANED AND REINSTALLED REF AMM 25-66-01. OPS CHECK GOOD OK FOR SERVICE.SDR SCNA20250108006Wire Harness · burnedWORK ORDER 92239, NR00008: B SYS ELECTRIC HYD PUMP WIRING HARNESS CONNECTOR IS BADLY BURNED AND IN NEED OF REPLACEMENT. RESOLUTION: PULLED BREAKERS ON THE P-91 PANEL. LEFT PLUG OFF FROM PUMP.SDR SCNA20250108004Flt Controls · stiffDEFECT 796540: FLIGHT CONTROLS ARE ABNORMALLY STIFF. RESOLUTION: LUBED AILERON MIXER REF AMM 27-11-81 OPS TEST GOOD.SDR SCNA20250102001Aileron · lack of lubeON APPROACH WITH FLAPS 30, GEAR EXTENDED, HYD B QTY WAS 69-70% AND PRESSURE AT 2870. AILERONS BEOND 10-15 DEGREES OF BANK WERE VERY STIFF AND HARD TO GET BEOND. CONTROLS REMAINED STIFF ON ROLL OUT UNTIL FLAPS RETRACTED. LUBRICATED AILERON POGO QUADRANT PER A
Back to Boeing 737-8F2