Boeing 737-8H4
Service difficulty reports · 24,363
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7378H4' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7378H4' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2021062926472Angle · corrodedAFT CARGO R/H TRANSITION ANGLE HAS LARGE AREAS OF CORROSION BOTH UPPER + LOWER SURFACE B5 727I-767 / R/H TRANSITION ANGLE WAS REPLACED FROM 727H +10 THRU BS 767 ON NR# D469439SDR SWAA2020111026527Lens · crackedRIGHT AFT OVERWING ILLUMINATION LIGHT LENSE CRACKED. REPLACED RIGHT AFT SLIDE/OVERWING LIGHT LENS, IAW AMM 33-51-04-960-801 STEPS 2F (1) (A) AND (D) A TAG A91524.SDR SWAA2021071526503Angle · corrodedFWD PIT STA 418 FLOOR SUPPORT SHIELD UPPER SURFACE CORRODED AT RBL24 AND W/L157 / REMOVED CORROSION ON R/H Z-ANGLE AT STA 418 IN FWD CARGO COMPARTMENT IAW SRM 51-10-02-0G-0. VERIFIED LIMITS ORIGINAL THICKNESS .040'; LOSS OF .006' REMAINING .034' OUT OF LIMITS SDR SWAA2021071526492Shield · corrodedFWD PIT STA 438 FLOOR SUPPORT SHIELD UPPER SURFACE CORRODED STA RBL24 AND W/L157 / REMOVED CORROSION ON FWD SHIELD IN FWD CARGO COMPARTMENT AT STA 438; RBL 24 IAW SRM 51-10-02-0G-0. VERIFIED LIMITS ORIGINAL THICKNESS .032; LOSS OF .013; REMAINING .019' OUT OF SDR SWAA2021071526496Rail · corrodedFWD PIT STA 500I LATERAL FLOOR SUPPORT UPPER SURFACE CORRODED FROM LBL24 TO RBL24 AND W/L157 / EVALUATED CORROSION AT FWD PIT STA 500I FLOOR SUPPORT RAIL LBL 24 RBL 24 W/L 157 100% MATERIAL LOSS FOUND. NO PUBLICATION OF LIMITS WAS FOUND. REMOVED AND REPLACED FSDR SWAA2021071526099Support Angle · bentLEFT WING TRAILING EDGE PANEL 551FB WIRE BUNDLE SUPPORT ANGLE DAMAGED/BENT. MARKED. / REMOVED AND INSTALLED NEW LEFT WING TRAILING EDGE PANEL 551FB WIRE BUNDLE SUPPORT ANGLE IAW SRM 51-40-02-0G-0 AND BOEING DWG # 115A2710 REV - A TAG # A90358SDR SWAA2021071426497Support · corrodedFWD PIT STA 500I SIDEWALL SUPPORT UPPER SURFACE CORRODED AT RBL25 AND W/L157 / REMOVED CORROSION ON FWD PIT STA 500I; RBL 25 SIDE WALL SUPPORT ANGLE ORIGINAL MATERIAL THICKNESS .071 LOSS OF .003 WITH .068 REMAINING FOUND TO BE OUT OF LIMITS DUE TO NO PUBLISHEDSDR SWAA2021040826499Angle · corrodedAFT CARGO COMPARTMEMT R/H Z-ANGLE; RBL 20; WL 156; BS 727C + 16' - 767 CORRODED IN MULTIPLE PLACES / BLENDED AND REMOVED CORROSION AFT CARGO COMPARTMENT R/H Z ANGLE RBL 20 WL 156 BS 727C+16 - 767 AND VERIFIED WITH 10X MAGNIFYING IAW SRM 51-10-02-0G-0 ORIGINAL SDR SWAA2021040726453Floor Panel · damagedFWD CARGO FLOOR PNL 121ZBC IS DAMAGED. / REMOVED AND REPLACED FLOOR PANEL PER AMM 25-52-10.SDR SWAA2021040726092Floor Panel · corrodedFWD CARGO COMPT. FLOOR PANEL 120AF HAS CORROSION AROUND EDGES / EVALUATED CORROSION ON FWD CARGO COMPT FLOOR PANEL 120AF TOTAL ACCUMULATED DAMAGE FOUND TO BE MORE THAN THE 20' MAXIMUM ALLOWED OUT OF LIMITS IAW SRM 53-00-53-1A-1 FABRICATED NEW FLOOR PANEL 120AFSDR SWAA2021040726091Floor Panel · corrodedFWD CARGO COMPT. FLOOR PANEL 120BF HAS CORROSION AROUND EDGES ALSO MISALIGNED HOLES ON ONE SIDE / EVALUATED CORROSION AS OUT OF LIMITS DAMAGE GREATER THAN 20' IAW SRM SRM 53-00-53-1A-1 FIGURE 102. VERIFIED NEW MATERIAL AS 2024 T3 0.071' ATAG# GO6775 IAW AMM 25SDR SWAA2021040726088Floor Panel · corrodedFWD CARGO COMPT. FLOOR PANEL 120CF HAS CORROSION AROUND EDGES / REMOVED CORROSION AT FWD CARGO COMPT FLOOR PANEL 120CF CORROSION EXCESS MORE THAN 20' INCHES IS OUT OF LIMITS IAW SRM 53-00-53-1A-1 VERIFIED NEW MATERIAL AND FABRICATED NEW PNL 120CF IAW SRM 51-40SDR SWAA2021040726087Floor Panel · corrodedFWD CARGO COMPT. FLOOR PANEL 120DF HAS CORROSION AROUND EDGES / EVALUATED CORROSION ON FWD CARGO COMPT. FLOOR PANEL 120DF AND FOUND TOTAL LENGTH OF DAMAGE EXCEEDS 20' MAXIMUM ALLOWED - OUT OF LIMITS IAW SRM 53-00-53-1A-1 FABRICATED NEW PANEL 120DF IAW AMM 25-5SDR SWAA2021040726083Floor Panel · corrodedAFT CARGO COMPARTMENT FLOOR PANEL 140BF IS CORRODED / REPLACED AFT CARGO COMPT FLOOR PANEL 140BF WORK COMPLETED ON Y244387SDR SWAA2020111126494Angle · corrodedFWD PIT STA 500A TO STA 500I RT FLOOR SUPPORT Z ANGLE UPPER SURFACE CORRODED AT RBL 24 AND WL 157. REMOVED CORROSION AT RT Z-ANGLE STA 500A TO 500I, IAW SRM 51-10-02-0G-0 AND SRM 53-00-53-1A-2. VERIFIED WITH 10X MAGNIFICATION. ORIGINAL THICKNESS .040', AFTESDR SWAA2020111026071Angle · crackedRIGHT HAND PACK BAY HORIZONTAL ANGLE COMMON TO LOWER SIDE OF CENTER FUEL TANK AT STATION 663 IS CRACKED, 3RD FASTENER OUTBOARD OF KEEL BEAM VERTICAL ANGLE, MARKED. REMOVED DAMAGED AREA OF RIGHT HAND PACK BAY HORIZONTAL ANGLE COMMON TO LOWER SIDE OF CENTER FUESDR SWAA2020111026500Angle · corrodedAFT CARGO COMPARTMEMT LT Z-ANGLE LBL 20, WL 156, BS 727D +5' -807 CORRODED IN MULTIPLE PLACES. REMOVED CORROSION AT LT Z-ANGLE STA 727D TO 807+8, IAW SRM 53-00-53-1A-2. EVALUATED MATERIAL LOSS FROM STA 727D TO 747 ORIGINAL THICKNESS .040', AFTER REWORK .036'SDR SWAA2020111026495Angle · corrodedFWD PIT STA 440 TO STA 500I LT FLOOR SUPPORT Z ANGLE UPPER SURFACE CORRODED AT LBL 24 AND W/L 157. REMOVED CORROSION ON FWD PIT STA 440 TO 500I LT FLOOR SUPPORT Z-ANGLE LBL 24, IAW B737 SRM 51-10-02-0G-0 ITEM 15. ORIGINAL 'T' .040, REMAINING .028, LOSS .012'SDR SWAA2020102926760Slide · dislodgedFWD SERVICE DOOR SLIDE FELL PARTIALLY OUT OF SHROUD. REINSERTED SLIDE, PER MM 25-66-01 AND MT 725-61-06.SDR SWAA2021082525849Floor Panel · corrodedPANEL 532 EB HAS EVIDENCE OF CORROSION / REPLACED PANEL WITH SERVICABLE PANEL T0 BE INSTALLED ON W/O 698428SDR SWAA2021082525851Floor Panel · corrodedPANEL 532 GB HAS EVIDENCE OF CORROSION / REPLACED PANEL WITH SERVICEABLE PANEL TO BE INSTALLED ON W/O 698428SDR SWAA2020111126070Angle · crackedLEFT HAND PACK BAY HORIZONTAL ANGLE COMMON TO LOWER SIDE OF CENTER FUEL TANK AT STATION 663 IS CRACKED, 3RD FASTENER OUTBOARD OF KEEL BEAM VERTICAL ANGLE, MARKED. REMOVED DAMAGED AREA OF LEFT HAND PACK BAY HORIZ ANGLE COMMON TO LOWER SIDE OF CENTER FUEL TANK SDR SWAA2020102826032Lens · missingOVERWING EXIGT LIGHT MISSING. RESECURED LENS IN REF TO SIP.SDR SWAA2020102825799Slide · dislodgedDOOR L1 WAS OPENED PARTIALLY WITH GINT BARS INSTALLED. SLIDE WAS DISLODGED, DID NOT DEPLOY. REINSTALLED FWD ENTRY DOOR SLIDE, PER MT 725-61-06.SDR SWAA2021081225739Strake · damagedFOUND DAMAGE ON RH WINGLET LOWER STRAKE TRAILING EDGE. / R+R R/H WINGLET STRAKE PER A.I.P FINALL INSTALL WILL BE ACCOMPLISHED ON TASK CARD 757-31-02POS P/H P/N OFF/ON 737-2510-4 S/N OFF 12225406/001 S/N ON 1254031/001SDR SWAA2021072025713Attach Angle · crackedON THE RIGHT WING; JUST INBD OF THE DELECTION RIB. THE ATTACH ANGLE IS CRACKED. (OTBD END OF LOWER BULB SEAL.) / REMOVED AND DAMAGED ANGLE PER SRM 51-40-02; 104029. INSTALLED NEW ATTACH ANGLE PER SRM 51-40-02.SDR SWAA2021081325420Fairing · crackedLEFT AFT STRUT FAIRING AFT O/B ANGLE CRACKED REF. EA OTHER-54EA-07834REPLACED AFT L/H STRUT FAIRING ASSY IAW AMM 54-52-04 #61795 PER OTHER-54EA-07834 TLD TRACKING REPLACEMENT OF P/N 313A2060-957 WITH P/N 313A2060-73 PER EA OTHER 54EA-07834.SA-M 115 P/N OFF 313SDR SWAA2020102725746Sign · detachedEXIT SIGN CENTER CEILING FELL OFF. REINSTALLED EXIT SIGN PER SIP.SDR SWAA2021052525349Gusset · crackedFWD CARGO GUESSET CRACKED BS 500I STR19R / FWD CARGO REMOVED AND REPLACED GUSSET AT STA-500 I/ STR-19R PER SRM 51-40-02SA-M 326 A1200850SDR SWAA2020102825151Battery · inoperativeAFT EMERGENCY LIGHTS M1673 BATTERY WILL NOT CHARGE. REPLACED AFT EMERGENCY LIGHT M1673 BATTERY AND PERFORMED GOOD TEST, IAW AMM 33-51-06-960-805 ATAG: AD8863.SDR SWAA2020102625145Motor · failedELECTRIC TRIM INOPERABLE WOULD NOT ENGAGE A OR B AUTO PILOT. R & R STAB TRIM MOTOR, PER MM 27-41-71. OPERATIONS CHECK GOOD ISSUE 3063169POS, TAG 654366 P/N OFF/ON 6355C0001-02 S/N OFF 5258 S/N ON 02232.SDR SWAA2021050624645Slider · crackedR/H HORIZONTAL UPPER FWD SLIDER IS CRACKED / REMOVED AND REPLACED PER M/M 53-31-31.INSPECTOR: E50309SDR SWAA2021050624644Slider · crackedL/H HORIZONTAL UPPER FWD SLIDER IS CRACKED / REMOVED AND REPLACED PER M/M 53-31-31INSPECTOR: E50309SDR SWAA2020102624994Battery · failedFWD EMERGENCY FLASH LIGHT WILL NOT TEST. REMOVED AND REPLACED BATTERY, PER SIP.SDR SWAA2020102124485Lamp · inoperativeRT SIDE FWD OVERWING EMERGENCY LIGHT INOPERABLE. RELAMPED IAW AMM 33-51-04. OPERATIONS CHECK GOOD, AMT 142885.SDR SWAA2020102124324Battery · inoperativeAFT INBOARD EMERGENCY FLASHLIGHT INOPERABLE. R & R FLASHLIGHT BATTERY, PER 25-64-00.SDR SWAA2020102124470Sign · looseOVERHEAD EXIT SIGN ROW 15 FELL OFF. RESECURED IN REF TO SIP.SDR SWAA2020102124329Light · inoperativeLT FWD EMERENCY EXIT DOOR LIGHT INOPERABLE. EMERGENCY LIGHT OPERATIONS NORMAL.SDR SWAA2020102024351Cover · missingEXIT SIGN COVER AT ROW 13 SEAT C IS MISSING. INSTALLED EMER EXIT SIGN COVER AT SEAT 13A, PER SIP.SDR SWAA2020102024353Sign · unsecureEXIT SIGN FOR OVERWING EXITS FELL DOWN. RESECURED IN REF TO SIP.SDR SWAA2021080323561Floorbeam · crackedCABIN FLOOR - STA. 537.5 - RBL PANEL BREAK JUST OUTSIDE 0 - CRACKED AT BOTH FASTNERS / CABIN FLOOR STA 537 RBL 0' TO RBL 24 PNL BREAK BEAM CRACKED. REMOVED CRACKED PNL BREAK I/A/W SRM 51-40-02-0G-0. LOCATED AND DRILLED NEW PNL BREAK BEAM I/A/W SRM 51-40-05-0G-SDR SWAA2021072823550Fairing · cracked#1 ENG PYLON AFT STRUT FAIRING (ZONE 434) AFT FITTING O/B AREA CRACKED THROUGH RADIUS - AS MARKED REMOVED AND REPLACED #1 ENG AFT STRUT FAIRING IAW AMM 54-52-04. REF OTHER-54EA-07715 #1 ENGINE PYLON AFT PYLON FAIRING ALTERNATE PART. THIS EC/TC ACCOMPLISHES THESDR SWAA2021071523255Support Angle · corrodedFWD CARGO STA 500I; LOWER BULKHEAD SUPPORT ANGLE CORRODED. / REPLACED BULKHEAD SUPPORT ANGLE PER SRM 53-40-02SA-M 326 A1184532SDR SWAA2021052623560Floor Panel · crackedCABIN FLOOR - STA. 537.5 - LBL PANEL BREAK JUST OUTSIDE 0 - CRACKED AT FASTNER / REMOVED CRACKED CABIN FLOOR PANEL BREAK STA 537.5 AND REPLACED WITH NEW PANEL BREAK P/N 143A5240-35 IAW SRM 51-40-02-0G-0 AND BOEING DWG 143A0060 REV A A TAG WN41284SDR SWAA2021071523057Plate · corrodedFWD CARGO L/H SIDEPLATE; CORROSION AT FASTENER HOLES BETWEEN STATIONS 500H- 500I. / REPAIRED PER SRM 53-00-53-2R-5 ; SEE INDIVIDUAL SIGNOFFS FOR ALL WORK ACCOMPLISHED SEE SAM326: A1184521SDR SWAA2021051223083Skate Angle · chafedUPPER FUSELAGE STA 1018-1054; RBL15; CLOSURE ANGLE FOR VERTICAL STAB (SKATE ANGLE) INBD SIDE HAS LIGHT CHAFING WEAR. / REMOVED + REPLACED CLOSURE ANGLE STA 1016-1140 RBL 15 IAW SRM 51-40-02-0G-0; 51-10-02-0G-0; 51-40-05-0G-0; AMM 51-21-99-300-801; + DWG 148A83SDR SWAA2021051223082Skate Angle · chafedUPPER FUSELAGE STA 1008-1016; RBL15; CLOSURE ANGLE FOR VERTICAL STAB (SKATE ANGLE) INBD & OTBD SIDES; LIGHT CHAFING WEAR. / REMOVED + REPLACED CLOSURE ANGLE STA 1006-1016 RBL 15 IAW SRM 51-40-02-0G-0; 51-40-05-0G-0; AMM 51-21-99-300-801; + DWG 147A0030 SHT 26 SDR SWAA2021051223081Skate Angle · chafedUPPER FUSELAGE STA 1040-1048; 1077-1084 & 1103-1108; LBL15; CLOSURE ANGLE FOR VERTICAL STAB (SKATE ANGLE) INBD SIDE; 3 EA MRK'D AREAS HAVE LIGHT CHAFING WEAR. / REMOVED + REPLACED UPPER FUSELAGE CLOSURE ANGLE FOR VERTICAL STAB STA 1016-1140 LBL 15 IAW SRM 51-4SDR SWAA2021051223080Skate Angle · chafedUPPER FUSELAGE STA 1008-1013; LBL15; CLOSURE ANGLE (SKATE ANGLE) INBD SIDE HAS LIGHT CHAFING WEAR. / REMOVED + REPLACED CLOSURE ANGLE STA 1006-1016 LBL 15 IAW SRM 51-40-02-0G-0; 51-40-05-0G-0; 51-10-02-0G-0; AMM 51-21-99-300-801; + DWG 147A0030 SHT 27 REV -SDR SWAA2020102822919Floor Panel · damagedCABIN FLOOR PANEL 242CF AFT OUTBOARD CORNER HAS DAMAGE. REPAIRED CABIN FLOOR PANEL 242CF AFT OUTBOARD CORNER DAMAGE, IAW SRM 53-00-50-2R-0 AND IAW SRM 53-00-50-2R-1 A94417, A72535, A34007.
Back to Boeing 737-8H4