Boeing 737-8H4
Service difficulty reports · 24,363
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7378H4' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7378H4' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2020070292884Angle · corrodedAFT CARGO BAY Z-ANGLE HAS CORROSION AT BS 767 TO BS 727A RBL22; WL154. BLENDED CORROSION ON AFT CARGO Z-ANGLE STA 767-727A RBL 22. VERIFIED MATERIAL LOSS ORIG 'T' .040 REMAINING 'T' .030 LOSS OF .010 FOUND TO BE OUT OF LIMITS. REMOVED AND REPLACED Z-ANGLE ASDR SWAA2020070192896Angle · crackedRT A/C PACK BAY HORIZONTAL ANGLE COMMON TO LOWER CENTER FUEL TANK AT STATION 663 IS CRACKED 3RD FASTENER OUTBOURD OF KEEL BEAM VERTICAL ANGLE. CUT + REMOVED DAMAGE RT A/C BAY; HORIZONTIAL ANGLE COMMON TO LOWER CENTER FUEL TANK AT STA 663. FABRICATED + INSTALSDR SWAA2020070192895Angle · crackedLT A/C PACK BAY HORIZONTAL ANGLE COMMON TO LOWER CENTER FUEL TANK AT STATION 663 IS CRACKED 3RD FASTENER OUTBOURD OF KEEL BEAM VERTICAL ANGLE. CUT + REMOVED DAMAGE LT A/C PACK BAY; HORIZONTIAL ANGLE COMMON TO LOWER CENTER FUEL TANK AT STA 663. FABRICATED + ISDR SWAA2021081392789Angle · corrodedFWD CARGO COMP FLOOR STRUCTURE;AFT RH BULKHEAD ANGLE STA.500I RBL 26' WL 156'CORROSION AROUND FASTNER HOLE / REMOVED CORROSION FROM FWD CARGO; AFT R/H BULKHEAD ANGLE STA 500I ORIG 'T' 0.071' REMAINING 0.053' LOSS 0.018' OUT OF LIMITS IAW SRM 53-00-53-1A-2. REMSDR SWAA2021072092792Attach Angle · bentFWD CARGO COMPARTMENT SIDEWALL ATTACH ANGLE COMMON TO FRAME AT STA 500D; RBL 28; BETWEEN STR 26R AND 25R; IS DENTED AND BENT; MARKED. / REMOVED AND REPLACED FWD CARGO SIDEWALL ATTACH ANGLE STA 500D R/H SIDE IAW SRM 51-40-02-0G-0 AND AIPC 53-11-00-35A.SDR SWAA2021071592788Bulkhead · corrodedFWD CARGO COMP FLOOR STRUCTURE;AT BULKHEAD BOTTOM ANGLE 500I ABOVE RBL 0-24'WL 156'CORROSION AROUND FASTNER HOLES / EVALUATED CORROSION ON FWD CARGO COMPARTMENT AFT BULKHEAD SUPPORT ANGLES FOUND TO BE OUT OF LIMITS DUE TO NO SRM DAMAGE LIMITS GIVEN. REPLACED BSDR SWAA2021060892783Shield · corrodedFWD CARGO COMP FLOOR STRUCTURE;RH FLOOR SHIELD STA.500-500A ABOVE STR 25RH RBL 24'CORROSION AROUND FASTNER HOLES / REMOVED CORROSION ON FWD CARGO RH FLOOR SHIELD STA 500-500A ORIG 'T' 0.032' REMOVED 0.005' REMAINING 0.027' OUT OF LIMITS IAW SRM 53-30-15-1A-1. SDR SWAA2020070192787Angle · corrodedFWD CARGO COMP FLOOR STRUCTURE, RT Z-ANGLE STA 500D-500I ABOVE STR 25R RBL 24, CORROSION AROUND FASTNER HOLES. REMOVED CORROSION FROM RT Z ANGLE 500D TO 500I ORIGINAL .040 .009 REMOVED .031 REMIANING FOUND TO BE OUT OF LIMITS REMOVED RT Z ANGLE SECTION 500F TSDR SWAA2020070192786Angle · corrodedFWD CARGO COMP FLOOR STRUCTURE, LT Z-ANGLE STA 500D-500I ABOVE STR 25L LBL 24, CORROSION AROUND FASTNER HOLES. REMOVED CORROSION LT Z ANGLE STA 500D TO 500I. ORIGINAL THICKNESS .040 .008 REMOVED .032 REMAINING IN LOWEST AREA. LT Z ANGLE SECTION REMOVED FROM 5SDR SWAA2020061792803Pump · low pressureON CLIMB OUT PASSING 18;000. ENG 1 A & B SYS HYD LOW PRESSURE PUMP LIGHT ILLUMINATED. CHECKED HYD OIL QTY & PRESSURE, A SYS PRESSURE WAS DROPPING. CONSULTED QRH CHECKLIST 13:4 LOSS OF A SYS. COMPLETED CHECK LIST AND RETURNED TO DEPARTURE. HYD CHECKED BRAKESDR SWAA2020061792547Cover · looseMID CABIN EXIT SIGN COVERS FELL OFF. REINSTALLED EXIT SIGN COVER IAW SIPSDR SWAA2021062392288Floor Panel · looseFLOOR BOARD LOOSE ROW 17. METAL BOWING WHEN NOT UNDER FOOT: SPRINGING DOWN UNDER WEIGHTCOMPLIED WITH EA 1-A53-31403 REV. 1 DATE 06/22/2017. PANEL IS FREE OF DEFECTS (CRACKS; DENTS; PUNCTURE; ETC) AT THIS TIME. REPEAT INSPECTION REQUIRED: PERFORM VISUAL EXAMINASDR SWAA2020061792548Flashlight · inoperativeAFT GALLEY RT OUTBD FLASHLIGHT WILL NOT TEST. R & R THE AFT RT OTBD FLASHLIGHT ASSY IAW AMM 25-64-00.SDR SWAA2020061692028Flashlight · no testCREW REPORTED THE FWD EMERGENCY FLASHLIGHT NOT TESTING. R & R THE FWD FLASHLIGHT IAW AMM 25-64-00.SDR SWAA2020061692049Slide · out of positionL1 DOOR SLIDE REQUIRES REPOSITIONING INSIDE THE COMPARTMENT. REPOSITIONED L1 DOOR SLIDE IAW MT 725-61-06.SDR SWAA2020061692048Slide · out of positionSERVICE DOOR SLIDE REQS REPOSITIONING INSIDE COMPARTMENT. REPOSITIONED THE DOOR SLIDE IAW MT 725-61-06.SDR SWAA2020061692050Charger · inoperativeTHREE EMERGENCY LIGHTS AROUND FWD SERVICE DOOR INOPERATIVE. REMOVED AND REPLACED FWD BATTERY CHARGER AND BATTERY PACK IAW AMM 33-51-06. OPS CHECKED GOOD.SDR SWAA2021081791591Bracket · brokenR/H WING TRAILING EDGE PANEL 651FB FWD BRACKET IS BROKEN / REMOVED AND REPLACED R/H WING TRAILING EDGE PANEL 651FB FWD BRACKET IAW SRM 51-40-02-0G-0 AND DWG 115A2710 REV- SHEET 9.SDR SWAA2021072991547Floorboard · looseFLOOR BOARD LOOSE ROW 17. METAL BOWING WHEN NOT UNDER FOOT: SPRINGING DOWN UNDER WEIGHTCOMPLIED WITH EA 1-A53-31403 REV. 1 DATE 06/22/2017. PANEL IS FREE OF DEFECTS (CRACKS; DENTS; PUNCTURE; ETC) AT THIS TIME. REPEAT INSPECTION REQUIRED: PERFORM VISUAL EXAMINASDR SWAA2020061291294Battery · dischargedEMERG LIGHTS AT ROW 10 DEF + 14 DEF INOP. REMOVED + REPLACED BATTERY + BATTERY CHARGER AT STA 500 C ON RT SIDE. OPS CHECK GOOD IAW AMM 33-51-06.SDR SWAA2021082091086Fairing · debondedL/H WING FWD FLAP TRACK FAIRING 544AB (#1) HAS DISBOND AREA BETWEEN FWD AND AFT MOUNT HOLES. / REMOVED AND REPLACED L/H WING FWD FLAP TRACK FAIRING 544AB (#1) IAW AMM 27-51-28-000-801 AND AMM 27-51-28-400-801. VERIFIED ADJUSTMENT IAW AMM 27-51-28-820-801. NO ASDR SWAA2021081091089Skin · bentAPU DOOR IS BENT IN FWD. L/H CORNER / REPAIRED APU ACCESS DOOR SKIN; FWD FRAME & L/H ZEE FRAME PER ATS ER 20-02730 REV IR AND SWA CARD NUMBER 20-152-00794 REV IRSDR SWAA2020061091098Floorboard · looseFLOORBOARD LOOSE ROW 17. METAL BOWING WHEN NOT UNDER FOOT: SPRINGING DOWN UNDER WEIGHT COMPLIED WITH EA 1-A53-31403 REV 1 DATE 06/22/2017. PANEL IS FREE OF DEFECTS (CRACKS; DENTS; PUNCTURE; ETC) AT THIS TIME. REPEAT INSPECTION REQUIRED: PERFORM VISUAL EXAMINATSDR SWAA2021072991305Web · corrodedAFT CARGO COMPARTMENT LOWER SILL WEB IN DOORWAY HAS CORROSION AROUND NUT PLATES; BETWEEN BS 810 - 840; RBL 30; WL 156 / EVALUATED AND REMOVED CORROSION DAMAGE FROM AFT CARGO DOOR CUTOUT LOWER SILL WEB IAW B737 SRM 51-10-02-0G-0 & 53-60-15-1A-1. FOUND OUT OF LISDR SWAA2020061291039Flashlight · inoperativeFWD F/A INBD FLASHLIGHT DOES NOT TEST. (CABIN EMERGENCY FLASHLIGHT HOLDERS/FLASHLIGHTS) CLOSING DMA 0228300R&R FLASHLIGHT PER AMM 25-64-00 CL 77071.SDR SWAA2021080590731Floor Panel · damagedSEVERAL FWD CARGO FLOOR PANELS DAMAGED / REPLACED DAMAGED PANELS.SDR SWAA2020061290477Vapor Barrier · crackedCENTER WING REAR SPAR VAPOR WEB CRACKED 8.0' AT RBL 31.83 FROM STIFFENER FOR FASTENER HEAD. REPETITIVE ACTION REQUIRED: REINSPECT PER SRM 57-10-10-1A-2: PERFORM VISUAL INSPECTION OF THE REPAIR AREA AT 1200 FLIGHT CYCLES INTERVALS. IF THE CRACK HAS GROWN PAST TSDR SWAA2020061290492Vapor Barrier · crackedCENTER WING REAR SPAR VAPOR WEB HAS A 10' DIAGONAL CRACK THAT EXTENDS FROM RBL 30.83 TO RBL 35. THE CRACK EXTENDS UNDER STIFFENER AT RBL 31.83. THIS IS THE LOWER RIGHT WEB (GFRP) REPAIRED CRACK PER SRM 57-10-10-2R-2REPETITIVE ACTION REQUIRED: DO A DETAILED VISSDR SWAA2020061090600Battery · dischargedFWD FLASHLIGHT TEST BAD, RED LIGHT ILLUMINATES WHEN TESTED. ( CABIN EMERGENCY FLASHLIGHT HOLDERS/FLASHLIGHTS ) REPLACED BATTERY IN FWD O/B FLASHLIGHT REF AMM 25-64-00. OPS CHECKS GOOD.SDR SWAA2020061090603Smoke Detector · intermittentSMOKE ALARM IN AFT LAV, FO SIDE WAS INTERMITTENT. NO SMOKE IN LAV, REPLACED SMOKE DETECTOR PER AMM 26-14-01.SDR SWAA2020061090501Fuse · inoperativeLT FWD ENTRY DOOR SLIDE EMERGENCY ESCAPE LIGHT. WILL NOT ILLUMINATE DURING TEST / REMOVED AND REPLACED FUSE IN POWER SUPPLY M1675 IAW AMM 33-51-06 OPS CHECKED GOOD.SDR SWAA2021071690386Baffle · corroded**CORROSION** AFT CARGO COMPARTMENT BAFFLE STA. 747-767; RBL30;WL165 HAS CORROSION / REMOVED AND REPLACED R/H BAFFLE FS 747-767 WL 165 DUE TO OUT OF LIMITS CORRISION IAW SRM 51-40-02-0G-0; SRM 53-00-04-1A-1 AND DWG 146A7505; DWG 146A7500SDR SWAA2021060290111Vapor Barrier · crackedRIGHT HAND MAIN LANDING GEAR FORWARD BULKHEAD AT B.S. 540 VAPOR BARRIER CRACKED IN TWO (2) LOCATIONS.PERFORMED INTERIM REPAIR PER REPAIR 57 EA-07683 FOR FURTHER CORRECTIVE ACTION REF 943 & #V005123REPETITVE ACTION REQUIRED:REMOVE ALUM FOIL TAPE AND PERFORM DETSDR SWAA2021050590123Seal · crackedLT HORIZ STAB UPPER FWD SLIDING SEAL CRACKED / REMOVED AND REPLACED LT HORIZ STAB UPPER FWD SLIDING SEAL PER AMM 52-31-31INSP P44SDR SWAA2021050590122Seal · crackedRIGHT HORIZ STAB UPPER FWD SLIDING SEAL CRACKED / REMOVED AND REPLACED RIGHT HORIZ STAB UPPER FWD SLIDING SEAL PER AMM 53-31-31INSP P44SDR SWAA2020061890059Floor Panel · damagedRH CABIN FLOOR PANEL 232QF HAS DAMAGE ON AFT EDGE. (MARKED) / REPAIRED DAMAGE ON AFT EDGE OF RH CABIN FLOOR PANEL 232QF IAW SRM 53-00-50-2R-1. DAMAGE WAS BEYOND ALLOWABLE LIMITS IAW SRM 53-00-50-1A-1 PARA 4.E.(2)(B) DAMAGE WAS WITHIN 3.0' FROM THE EDGE OF THE SDR SWAA2020061690103Battery Pack · inoperativeFWD GALLEY LEFT EMERGENCY LIGHTS BATTERY PACK INOPERATIVE. R & R THE BATTERY PACK IAW AMM 31-51-06. OPS CHECKED GOOD IAW 31-51-21, AND 31 51-11.SDR SWAA2020060990474Battery Pack · dischargedEMERGENCY EXIT LIGHTS FO SIDE STAY ON WITH SWITCH IN ARMED MODE. FOUND M1695 RT EMERGENCY CHARGER + BATTER PACK INOP. REPLACED CHARGER + BATTERY PACK PER AMM 33-51-06.SDR SWAA2020060990503Battery · dischargedCREW PREPARED AFT GALLEY EMERGENCY FLASHLIGHT WILL NOT TEST. R&R BATTERY IAW S.I.P.SDR SWAA2020061589823None · puncturedSUPPLEMENTAL INFORMATION: AFT CARGO; ZEE CHANNEL BETWEEN STATIONS 727F-727G;WL155; STRINGER 25R HAS PUNCTURE /CRACK IN UPPER SURFACE. / DAMAGED SECTION OF ZEE ANGLE WAS REPLACED ON N/R Y228940 W/O # 41066/1600/0026 STA 727F - 727G P/N 146A7502-52SDR SWAA2021082590524Panel · corrodedFUEL PANEL 533AB HAS SIGNS OF CORROSION ON PANEL ADJACENT TO SEAL; MARKED. / EVALUATED SIGNS OF CORROSION ON FUEL PANEL 533AB. NO DAMAGE LIMITS GIVEN FOR AREA OF PANEL AFFECTED. REPLACED LEFT WING FUEL PANEL 533AB WITH A SERVICABLE PANEL IAW B737 SRM 51-10-02-SDR SWAA2021081989484Plate · corrodedAFT CARGO PIT FLOOR STRUCTURE STA 772 TRANSITION PLATE HAS VARIOUS AREAS OF CORROSION. / STA 772 TRANSITION PLATE FOUND TO BE OUT OF LIMITS DUE TO 100% MATERIAL LOSS IAW B737 SRM 53-00-53-1A-2 NEW TRANSITION PLATE P/N 146A9401-4 IAW AIPC 53-42-11-26 ITEM 955 WSDR SWAA2021072990018Shield · corrodedC-2 PIT; THRESHOLD FWD I/B CORNER SHEILD PLATE HAS AREAS OF CORROSION ON LOWER SIDE OF PLATE; MARKED IN BLACK / VERIFIED MATERIAL P/N 453A2611-1 TAG 1 A56583 BOEING 737-800 DWG 453A2600 REV A; REPLACED IAW SRM 51-40-02.SDR SWAA2021072990017Shield · corrodedC-2 PIT; THRESHOLD AFT I/B CORNER SHEILD PLATE HAS AR3AS OF CORROSION ON LOWER SIDE OF PLATE; MARKED IN BLACK / VERIFIED MATERIAL P/N 453A2611-2 ATAG A96311 IAW B737-800 DWG 453A2600 REV A INSTALLED ON SA-M 565SSDR SWAA2021071689828Baffle · cracked#1 ENGINE I/B FAN COWL; CRACK IN FRAME BAFFEL AFT OF OIL ACCESS DOOR. / REMOVED CRACKED FRAME BAFFLE AFT OF OIL ACCESS DOOR ON #1 ENGINE I/B FAN COWL. RECIVED NEW FRAME BAFFLE LOCATED AND DRILLED AND INSTALLED NEW FRAME BAFFLE ON #1 ENGINE I/B FAN COWL.SDR SWAA2020061589491Angle · corrodedAFT CARGO; ZEE CHANNEL BETWEEN STATIONS 727J-767;WL155 STRINGER 25R HAS CORROSION ON UPPER SURFACE. / BLENDED OUT WORN AREA AT VERTICAL STAB L/H SKATE ANGLE AT STA 1085 INNER SURFACE I-A-W 53-80-13-1A-1. VERIFIED MATERIAL LOSS ORIGINAL .063 REMOVED .010 REMAINSDR SWAA2020061589490Angle · corrodedAFT CARGO; ZEE CHANNEL BETWEEN STATIONS 727G-767; WL155; STRINGER 25L HAS CORROSION ON UPPER SURFACE. / REMOVED CORROSION ON L/H ZEE ANGLE STA 727G-767 AND FOUND MATERIAL LOSS TO BE .006 WITH AN ORIGINAL T=.040 AND A REMAINING T=.034. 'OUT OF LIMITS' IAW SRM 5SDR SWAA2020061589489None · corrodedSUPPLEMENTAL INFORMATION: AFT CARGO PIT FLOOR STRUCTURE STA 767 TO 847; L/H ZEE ANGLE HAS VARIOUS AREAS OF CORROSION. / DAMAGED SECTION OF ZEE ANGLE WAS REPLACED ON N/R Y228939 W/O # 41066/1600/0025 STE 767 - 847 P/N 146A7502-31SDR SWAA2021081888989Floor Panel · corrodedAFT CARGO COMPT. FLOOR PANEL 140CF EDGES HAVE CORROSION / INSTALLED BUSHING IN 551BB ATTACH BRACKET I/A/W B737 SOPM 20-50-03 PG 3 STEP B; PG 14 STEP C ATAG: A70685SDR SWAA2021081589025Shield · corroded*** CORROSION *** AFT CARGO COMPARTMENT AFT SHIELD HAS CORROSION FROM STA 847+9 TO 847+12; RBL 21; WL 167. / DUE TO NO ALLOWABLE LIMITS IN THE SRM; REMOVED AND REPLACED AFT CARGO; AFT SHIELD P.O. 765476 IAW SRM 51-40-02-0G-0; BOEING DWG 146A0081 REV A
Back to Boeing 737-8H4