SDR SCNA20150429068Skin · damagedRIGHT SIDE LOWER FUSELAGE FORWARD OF FORWARD CARGO DOOR FS 312 AND R25 EVIDENCE OF LIGHTNING STRIKE. REPAIRED SKIN.SDR SCNA20150429067Skin · damagedRIGHT SIDE LOWER FUSELAGE FORWARD OF FORWARD CARGO DOOR FS 330 AND R26 EVIDENCE OF LIGHTNING STRIKE. INSTALLED RIVET AFTER DRILLING OUT DAMAGE.SDR SCNA20150428066Skin · damagedRIGHT SIDE LOWER FUSELAGE FORWARD OF FORWARD CARGO DOOR FS 305 S25R EVIDENCE OF LIGHTNING STRIKE. REPAIRED LIGHTNING STRIKE.SDR SCNA20150428065Skin · damagedRIGHT SIDE LOWER FUSELAGE FORWARD OF FORWARD CARGO DOOR STA 325 AND R26 EVIDENCE OF LIGHTNING STRIKE. R & R 1 EA RIVET.SDR SCNA20150428064Skin · damagedRIGHT SIDE LOWER FUSELAGE FORWARD OF FORWARD CARGO DOOR FS 268.7 AND BETWEEN R26-R27 EVIDENCE OF LIGHTNING STRIKE. REMOVED DAMAGED RIVET AND INSTALLED NEW RIVET.SDR SCNA20150428063Skin · damagedRIGHT SIDE LOWER FUSELAGE FWD OF FWD CARGO DOOR FS 235.8 AND BETWEEN R25-R26 EVIDENCE OF LIGHTNING STRIKE. REPAIRED LIGHTNING STRIKE DAMAGE WITH RIVET REPAIR.SDR SCNA20150428062Skin · damagedRIGHT SIDE LOWER FUSELAGE FWD OF FWD CARGO DOOR FS 235.8 AND BETWEEN R25-R26 HAS EVIDENCE OF LIGHTNING STRIKE. REPAIRED LIGHTNING STRIKE DAMAGE FS 235.8 BETWEEN STR 25 & 26.SDR SCNA20150428061Skin · damagedRIGHT SIDE LOWER FUSELAGE AFT OF RADOME HAS LIGHTNING STRIKE BETWEEN FS 224.8-219.5. REPAIRED LIGHTNING STRIKE DAMAGE TO FUSELAGE BETWEEN FS 224.8-219.5 STGR 25.SDR SCNA20150428060Skin · damagedRT SIDE FORWARD LOWER FUSELAGE AFT OF RADOME BETWEEN FS 196.5-203 AND BETWEEN R23-R24 HAS LIGHTNING STRIKE. R & R 1 EACH RIVET.SDR SCNA20150428058Skin · damagedRIGHT SIDE LOWER FUSELAGE AFT OF RADOME FS 178 BETWEEN R23-R24 SKIN HAS LIGHTNING STRIKE. DAMAGE REPAIRED.SDR SCNA20150428057Skin · damagedRIGHT SIDE LOWER FUSELAGE AFT OF RADOME FS 178 BETWEEN R23-R24 HAS LIGHTNING STRIKE. R & R 1 EACH RIVET.SDR SCNA20150312051Light · brokenR1 DOOR EMERGENCY EXIT LIGHT BROKEN OFF OF MOUNT PLATE. R & R LIGHT FIXTURE.SDR SCNA20141223244Floorbeam · corrodedFWD WET AREA FLOORBEAM, BS 328 HAS CORROSION AT RBL 52. BLENDED CORROSION FOUND TO BE OUT OF LIMITS. REPAIRED BLEND OUT.SDR SCNA20141223259Threshold · corrodedAFT CABIN RT ON FRAME AT BS 986 JUST INBD OF R2 DOOR THRESHOLD, 2 EA AREAS OF CORROSION A250.004. BLENDED CORROSION FOUND TO BE OUT OF LIMITS. REPAIR ENTIRE UPPER CHORD.SDR SCNA20141223252Floor Support · crackedFWD WET AREA BS 294.5-312, RBL 15, FLOOR SUPPORT HAS A CRACK. R & R FLOOR SUPPORT.SDR SCNA20141223248Floor Support · crackedFWD WET AREA BETWEEN BS 328-344, LBL 11 FLOOR SUPPORT HAS CORROSION. BLENDED CORROSION FOUND TO BE OUT OF LIMITS. REMOVED FLOOR SUPPORT AND FABRICATED AND INSTALLED NEW FLOOR SUPPORT.SDR SCNA20141223238Floorbeam · corrodedFWD CARGO BAY AFT FLOOR PANEL LAND AT BS 500I LWR SURFACE CORRODED AT LBL 17.24 AND RBL 13.84. BLENDED CORROSION FOUND TO BE OUT OF LIMITS. REMOVED AND INSTALLED NEW FLOOR PANEL RAIL.SDR SCNA20141223237Stringer Clip · crackedSTRINGER CLIP 26R CRACKED AT BS 500I. REMOVED DAMAGED STRINGER CLIP AND INSTALLED NEW.SDR SCNA20141223262Baffle · crackedFOUND BAFFLE BETWEEN 500E-500F CRACKED. R & R BAFFLE.SDR SCNA20141223261Baffle · crackedDURING GVI, FOUND BAFFLE BETWEEN BS 500A - 500B CRACKED. R & R BAFFLE.SDR SCNA20141223253Tee Fitting · corrodedL2 DOOR CUT-OUT FRAME TO INTERCOSTAL T-FITTING CORRODED, STA 992.8 AND STR 15L.SDR SCNA20141223260Floor Support · corrodedAFT CABIN LT BETWEEN BS 967 & 947.5 ON FLOOR SUPPORT JUST INBD OF L-2 DOOR THRESHOLD AREA OF CORROSION AROUND FASTENER HOLE A250-007. CORROSION REMOVED FOUND OUT OF LIMITS. R & R PART.SDR SCNA20141223258Threshold · corrodedAFT CABIN RT APPROXIMATELY STA 967 BY R-2 THRESHOLD FRAME HAS AREAS OF CORROSION AROUND FASTENER HOLE A250-002. REMOVED CORROSION FOUND TO BE OUT OF LIMITS. R & R PART.SDR SCNA20141223254Stiffener · crackedRIGHT STABILIZER NR 1 SPAR RIB STAB STA 92.7 FWD VERTICAL STIFFNER CRACKED AT LOWER FLANGE, REPAIRED.SDR SCNA20141223236Door Frame · corrodedAFT CARGO DOOR CUTOUT LOWER FRAME CORRODED FROM BS 787 - 847. R & R AFT CARGO DOOR CUTOUT LOWER FRAME.SDR SCNA20141223257Stiffener · crackedLEFT HORIZONTAL STABILIZER 1 INNER SPAR RIB AT STA 92.7, NR 3 VERTICAL STIFFENER IS CRACKED ON LWR END. REPAIRED CRACKED RIB.SDR SCNA20141223255Stiffener · crackedRIGHT STABILIZER NR 1 INSPAR RIB AT STA 92.7 AFT VERTICAL STIFFNER CRACKED AT LOWER FLANGE, REPAIRED.SDR SCNA20141223256Stiffener · crackedLEFT HORIZONTAL STABALIZER NR 1 INNER SPAR RIB AT STABILIZER STA 92.7, NR 2 VERTICAL STIFFENER IS CRACKED ON LOWER END. REPAIRED CRACKED RIB.SDR SCNA20141223251Floor Support · crackedFWD WET AREA BS 344-360, LBL 11, FLOOR SUPPORT HAS A CRACK. R & R THE FLOOR SUPPORT.SDR SCNA20141223250Floor Support · crackedFWD WET AREA BS 328-344, LBL 46, FLOOR SUPPORT HAS A CRACK. R & R THE FLOOR SUPPORT.SDR SCNA20141223249Floor Support · crackedFWD WET AREA BETWEEN BS 312-328, LBL 46 FLOOR SUPPORT HAS A CRACK. R & R THE FLOOR SUPPORT.SDR SCNA20141223247Floor Support · crackedFWD WET AREA BETWEEN BS 344-360, BL 0, FLOOR SUPPORT HAS A CRACK. R & R FLOOR SUPPORT.SDR SCNA20141223241Floor Panel · corrodedBS 887 IN THE AFT BILGE, THE FLOOR PANEL SPLICE IS CORRODED. REMOVED CORROSION FOUND TO BE OUT OF LIMITS. FABRICATED NEW FLOOR PANEL SPLICE.SDR SCNA20141223246Floor Support · crackedFWD WET AREA BETWEEN BS 312-328, RBL 32 FLOOR SUPPORT HAS TWO CRACKS. R & R FLOOR SUPPORT.SDR SCNA20141223245Floor Support · corrodedFWD WET AREA FLOOR SUPPORT BETWEEN STA 277 - 294.5 AT BL 0 IS CRACKED. R & R FLOOR SUPPORT.SDR SCNA20141224263Frame · corrodedAFT CABIN LT AT BS 986 ON FRAME JUST INBD OF L2 DOOR THRESHOLD AREA AROUND FASTENER HOLE IS CORRODED A250.008. BLENDED CORROSION FOUND TO BE OUT OF LIMITS. REPAIRED ENTIRE UPPER CHORD.SDR SCNA20141223243Transition Panel · corrodedDURING GVI IN FWD CARGO, FOUND CORROSION ON RT AFT END OF TRANSITION PANEL BS 500I. BLENDED CORROSION FOUND TO BE OUT OF LIMITS. R & R SIDEPLATE CHANNEL.SDR SCNA20141223242Transition Panel · corrodedDURING GVI, FOUND CORROSION IN FWD CARGO ON LT AFT END OF TRANSITION PANEL BS 500I. BLENDED CORROSION FOUND TO BE OUT OF LIMITS. REPLACED SECTION.SDR SCNA20141223240Channel · puncturedFWD CARGO BAY SIDEPLATE CHANNEL AT RBL 21, PUNCTURED AT BS 500A+4. R & R SIDEPLATE CHANNEL.SDR SCNA20141223239Channel · crackedFWD CARGO BAY SIDEPLATE CHANNEL AT RBL 21 CRACKED AT STA 500E+8. CRACK EXTENDS SRM LIMITS. R & R SIDEPLATE CHANNEL.SDR SCNA20141024146Battery Pack · inoperativeR1 DOOR EMERGENCY LIGHT & OVERHEAD BIN EMERGENCY LIGHTS INOPERATIVE 2 FD & 3FD. R & R EMERGENCY EXIT BATTERY PACKS.SDR SCNA20141024145Battery Pack · inoperativeFLOOR EMERGENCY LIGHTS INOPERATIVE ROW 1AC TO 4ABC. R & R EMERGENCY EXIT BATTERY PACK.SDR CA140314018Bleed Air Sys · failed(CAN) PILOT, ABOUT 1 HR INTO THE FLIGHT, REPORTED THAT JUST BEFORE REACHING LEVEL OFF ALTITUDE (FL 400), BLEED TRIP OFF, LIGHT CAME ON RT SIDE. AFTER COMPLETING A TRIP RESET IAW QRH, LIGHT WENT OUT FOR 30 SECONDS AND LIGHT CAME BACK, THEN BLEED TRIP OFF LIGHSDR SCNA20140225043Cover · brokenR2 DOOR AREA PLASTIC EXIT SIGN COVER BROKEN. REPLACED EXIT SIGN COVER.SDR SCNA20140130005Battery Pack · failedFOUND BAD BATTERY PACK FOR EMERGENCY LIGHTS AT ROW 12ABC. R & R BATTERY PACK.SDR SCNA20131212232Lamp · inoperativeFOUND TWO LIGHTS OUT ON EMERGENCY LIGHT ROW 13DEF. REPLACED LAMPS. OPS CHECKED GOOD.SDR SCNA20131210231Cover · unsecurePLASTIC MOLDING OVER ELECTRICAL RUNNER BY 3C IS NOT ATTACHED TO THE FLOOR. R & R FLOOR TRACK EMERGENCY LIGHT LENS COVER AT SEATS 1C TO 4C APPROXIMATELY 10' STRIP. SECURITY CHECKS GOOD.SDR SCNA20131127230Light · unsecureFLOOR PROXIMITY LIGHT IN FORWARD CABIN, TAPE PEELING OFF. REPLACED FLOOR TRACK COVER.
Back to Boeing 737-8K2