Boeing 737-8Q8
Service difficulty reports · 1,686
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7378Q8' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7378Q8' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR MYWA09067Warning System · activatedETOPS SIGNIFICANT SYSTEM - ON DESCENT INTO MIA PRESSED RE-CALL AND THE "MACH TRIM" LIGHT ILLUMINATED.SDR MYWA09066Bleed Valve · defectiveETOPS SIGNIFICANT SYSTEM - APU DUCT PRESSURE INSUFFICIENT TO START ENGINE.SDR MYWA09065Radio · inoperativeETOPS SIGNIFICANT SYSTEM - NR 2 VHF INOP CAPT'S AND F/O'S POSITION.SDR XV6A2009120200011Light · inoperative3 EMERGENCY FLOOR PATH LAMPS INOP BETWEEN SEAT ROWS 6 AND 7.SDR MYWA09062Warning System · activatedETOPS SIGNIFICANT SYSTEM - ABORTED TAKEOFF IN ATL FOR ENGINE MASTER CAUTION INDICATION. AIRSPEED LESS THAN 65 KTS.SDR MYWA090056Warning System · malfunctionedABORTED TAKEOFF IN ATLANTA FOR MASTER CAUTION ENG INDICATION AIRSPEED LESS THAN 65 KTS. PERFORMED ENGINE CONTROL LIGHT BITE CHECK PER FIM 73-06-801, NO FAULTS NOTED. PERFORMED CDS BITE CHECK PER FIM 34-21-801, NO FAULTS NOTED EVERYTHING CHECKS OK.SDR SCNA09015Light · looseDURING A FUNCTIONAL CHECK, MAINTENANCE DISCOVERED EMERGENCY FLOOR LIGHTING BY SEAT 1C IS LOOSE. MAINTENANCE SECURED EMERGENCY FLOOR LIGHTING BY SEAT 1C.SDR SCNA09013Cover · looseA CLEAR PLASTIC COVER ON THE R-1 DOOR SLIDE WAS FOUND TO BE LOOSE. MAINTENANCE REMOVED THE SLIDE AND REPAIRED THE WINDOW AND THEN REINSTALLED THE SLIDE IN THE R-1 POSITION.SDR SCNA09012Battery Pack · failedDURING A FUNCTIONAL CHECK MAINTENANCE DISCOVERED THAT THE EMERGENCY BATTERY PACK DID NOT PASS IT'S CAPACITY CHECK. MAINTENANCE THEN REPLACED THE BATTERY PACK AND THE FUNCTION TEST IS NORMAL.SDR SCNA09011Power Supply · dischargedDURING A FUNCTIONAL CHECK MAINTENANCE DISCOVERED THAT THE M1673 CHARGER / POWER SUPPLY WAS UNSERVICEABLE. MAINTENANCE REPLACED THE EMERGENCY LIGHT POWER SUPPLY M1673.SDR SCNA09010Battery Pack · failedDURING A FUNCTIONAL CHECK MAINTENANCE DISCOVERED THAT THE EMERGENCY LIGHT BATTERY PACK FOR THE AFT LEFT OVERHEAD EXIT LIGHTS FAILED IT'S TEST. MAINTENANCE REPLACED THE BATTERY PACK AND THE EMERGENCY EXIT LIGHTS FUNCTION CHECK NORMAL.SDR SCNA09009Battery Pack · failedDURING A FUNCTIONAL CHECK THE EMERGENCY LIGHT BATTERY PACK AT ROW 12ABC FAILED IT'S TEST. MAINTENANCE REPLACED THE BATTERY PACK AND ITS FUNCTION CHECKS NORMAL.SDR SCNA09008Battery Pack · failedDURING A FUNCTIONAL CHECK THE EMERGENCY LIGHT BATTERY PACK AT ROW 18DEF FAILED AFTER 2 MINUTES. MAINTENANCE REPLACED THE BATTERY PACK AND EMERGENCY LIGHTS TEST NORMAL.SDR 2009FA0000416Attach Fitting · crackedFRAME ATTACH CLIP CRACKED AT BS 500E STRINGER 25 RT.SDR 2009FA0000414Power Supply · failedEMERGENCY LIGHT POWER SUPPLY M1671 INOP, WILL NOT TURN LIGHTS ON WHEN SYSTEM IS TURNED ON.SDR 2009FA0000413Battery · dischargedLT AFT F/A EMERGENCY FLASHLIGHT BATTERY DEAD.SDR 2009FA0000412Attach Fitting · crackedFRAME ATTACH CLIP CRACKED AT BS 500C STRINGER 25 RT.SDR 2009FA0000411Attach Fitting · crackedFRAME ATTACH CLIP CRACKED AT BS 500D STRINGER 25 RT.SDR 2009FA0000379Floorbeam · corrodedOUT OF LIMITS CORROSION FOUND ON FLOORBEAM UPPER CHORD AT BS 986.5 RBL26-30, LOWER SURFACE AROUND CLIPNUT HOLES DURING 10 YEAR CHECK. ORIGINAL MATERIAL THICKNESS .150, MATERIAL LOSS .070, BEAM IS LOCATED IN LAV/GALLEY "WET" AREA.SDR 2009FA0000378Floorbeam · corrodedOUT OF LIMITS CORROSION FOUND ON FLOORBEAM UPPER CHORD SURFACE AT BS 847 LBL4-RBL12 DURING 10 YEAR CHECK. ORIGINAL MATERIAL THICKNESS .150, MATERIAL LOSS .080. BEAM IS LOCATED IN LAV/GALLEY "WET" AREA.SDR 2009FA0000356Web · crackedFLOOR LEVEL WEB CRACKED BS 986.5 RBL 44 REMOVED, FABRICATED,AND INSTALLED FLOOR LEVEL WEB BS986.5 RBL44 IAW B737-800 SRM 51-40-02 FIGS 3AND12 BOEING DWG PL 147A5712SDR 2009FA0000355Attach Fitting · crackedFWD CARGO COMPARTMENT BS 500G FRAME ATTACH CLIP CRACKED JUST BELOW STR 25 LT. REMOVED AND REPLACED FWD CARGO COMPARTMENT BS 500G FRAME ATTACH CLIP JUST BELOW STR 25 LT IAW SRM 51-40-02 FIGS 8 AND 12.SDR 2009FA0000354Attach Fitting · crackedFWD CARGO COMPARTMENT BS 500E FRAME ATTACH CLIP CRACKED JUST BELOW STR 25 LT. REMOVED AND REPLACED FWD CARGO COMPARTMENT BS 500E FRAME ATTACH CLIP JUST BELOW STR 25 LT IAW SRM 51-40-02 FIGS 8 AND 12.SDR 2009FA0000353Intercostal · crackedFLOOR INTERCOSTAL CRACKED BS 328-334 RBL 34. REMOVED AND REPLACED INTERCOSTAL BS 328-334 RBL 34 IAW SRM 51-40-02 FIGS 8 AND 12.SDR 2009FA0000352Floorbeam · corrodedCORROSION ON FLOORBEAM UPPER CHORD UPPER SURFACE BS 947 LBL 4-RBL 12. REPAIRED FLOORBEAM UPPER CHORD UPPER SURFACE BS 947, LBL4-RBL 12 IAW SRM 53-00-51 FIG 203.SDR 2009FA0000351Intercostal · crackedFLOOR INTERCOSTAL CRACKED BS 312-328 LBL 46. REMOVED AND REPLACED FLOOR INTERCOSTAL BS 312-328 LBL 46 IAW SRM 51-40-02 FIGS 8 AND 12.SDR SCNA09007Light · inoperativeMAINTENANCE DISCOVERED THAT THE LEFT AFT OVERWING EMERGENCY EXIT LIGHT WAS INOPERATIVE DURING A FUNCTIONAL CHECK. THE EMERGENCY EXIT LIGHT WAS RELAMPED AND THE FUNCTION CHECK IS NOW NORMAL.SDR SCNA09002Light · inoperativeDURING MAINTENANCE INSPECTION, FOUND THE RT AFT OVERWING EXIT EMERGENCY LIGHT TO BE INOPERATIVE. MAINTENANCE RELAMPED THE LIGHT. OPERATIONAL CHECK IS NORMAL.SDR SCNA20090120001Power Supply · defectiveDURING MAINTENANCE INSPECTION, FOUND EMERGENCY LIGHTS AT SEATS 4-10 NOT WORKING. MAINTENANCE FOUND POWER SUPPLY AT ROW 6 LEFT FAULTY AND NOT CHARGING BATTERY PACK. FUSES AND POWER TO POWER SUPPLY CHECKS GOOD. REMOVED AND REPLACED POWER SUPPLY AND BATTERY ANSDR DU4R2008263Floorbeam · corrodedFOUND CORROSION IN AFT PIT ON TOP SURFACE OF FLOORBEAM AT BS 787 TO BS 847 RBL 16.SDR DU4R2008259Floorbeam · corrodedDURING SCHEDULED INSPECTION, FOUND CORRODED FLOOR BEAM AT BS 967 LBL 16 IN AFT CABIN.SDR DU4R2008258Floorbeam · corrodedDURING SCHEDULED INSPECTION, FOUND CORRODED FLOORBEAM AT BS 947 LBL 53 IN AFT CABIN.SDR DU4R2008257Shear Tie · corrodedDURING SCHEDULED INSPECTION FOUND CORRODED SHEAR TIE AT BS 986 RBL 39 TO LBL 44 IN AFT CABIN.SDR DU4R2008256Shear Web · corrodedDURING SCHEDULED INSPECTION, FOUND CORRODED SHEAR DECK AT BS 1010 LBL 31 IN AFT CABIN.SDR DU4R2008255Floor Support · corrodedDURING SCHEDULED INSPECTION, FOUND CORROSION ON FLOOR SUPPORT AT BS 344 BL 0 TO BL 10R.SDR DU4R2008254Floorbeam · corrodedDURING SCHEDULED INSPECTION, FOUND CORROSION ON FLOOR SUPPORT AT BS 328 RBL 9 - RBL 31.SDR DU4R2008253Web · corrodedDURING SCHEDULED INSPECTION, FOUND CORROSION ON UPPER SURFACE OF UPPER WEB BS 787 TO BS 847 S-25R IN AFT CARGO PIT.SDR DU4R2008252Structure · corrodedDURING SCHEDULED INSPECTION, FOUND CORROSION ON INNER CHORD AT LT OB FLOOR STRUCTURE AT BS 685-727.SDR DU4R2008251Floorbeam · corrodedDURING SCHEDULED INSPECTION, FOUND CORROSION ON FLOOR BEAM BS 312 LBL 13-30.SDR DU4R2008250Floor Support · corrodedDURING SCHEDULED INSPECTION, FOUND CORROSION ON FLOOR SUPPORT BS 340 LBL 22.SDR DU4R2008249Floorbeam · corrodedDURING SCHEDULED INSPECTION, FOUND CORROSION ON FLOOR BEAM BS 344 LBL 22.SDR DU4R2008248Floorbeam · corrodedDURING SCHEDULED INSPECTION, FOUND CORROSION ON BS 340 FLOOR SUPPORT LBL 11.SDR DU4R2008247Floorbeam · corrodedDURING SCHEDULED INSPECTION, FOUND CORROSION ON BS 325 FLOOR SUPPORT RBL 10.SDR DU4R2008246Floorbeam · corrodedDURING SCHEDULED INSPECTION, FOUND CORROSION ON BS 294 FLOORBEAM BL 0 TO BL 10R.SDR DU4R2008245Floor Support · crackedDURING SCHEDULED INSPECTION, FOUND FLOOR SUPPORT CRACKED AT BS 316 TO BS 324 RBL 30.SDR DU4R2008244Floorbeam · corrodedDURING SCHEDULED INSPECTION, FOUND CORROSION ON FLOORBEAM AFT CABIN BS 947 LBL 53.SDR DU4R2008243Floorbeam · corrodedDURING SCHEDULED INSPECTION, FL FOUND CORROSION ON FLOORBEAM AFT CABIN STA 986 RBL 39 TO LBL 44.SDR DU4R2008242Angle · chafedDURING SCHEDULED INSPECTION, FOUND LT IB FLAP RIB CHAFED AT IB TRACK FOR FORE FLAP ROLLER.SDR BJNA080403Lamp · inoperativeLEFT AFT EXTERNAL EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED THE EXTERNAL EMERGENCY LIGHT LAMP, OPERATIONAL CHECK GOOD. (K)SDR CA080305004Coupler · cracked(CAN) DURING CRUISE, CREW NOTED CABIN ALTITUDE WARNING. UNABLE TO CLOSE OUTFLOW VALVE EITHER ELECTRICALLY OR MANUALLY. EMERGENCY DESCENT PERFORMED, OXYGEN MASKS DROPPED. OUTFLOW VALVE WOULD CLOSE TO THE .2500 POSITION ON GAUGE. ATTEMPTED TO CLOSE VALVE MANUALL
Back to Boeing 737-8Q8