Boeing 737-932ER
Service difficulty reports · 3,110
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '737932ER' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '737932ER' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2026031001650Plate · corroded(LOG 1481434) CORROSION ON RT SIDE PLATE UPPER, & LWR SURFACE FROM BS 727 TO 767 AT AFT CARGO COMPARTMENT. RH SIDE PLATE FROM BS 727 TO 767 AT AFT CARGO COMPARTMENT. WAS REPLACED IAW SRM 51-40-02-0G.SDR DALA2026031001649Plate · corrodedCORROSION ON LH SIDE PLATE UPPER/LWR SURFACE FROM BS 727 TO 807 AT AFT CARGO COMPARTMENT. SIDE PLATE LH SIDE FROM STA 727 TO STA 807 AT AFT CARGO COMPARTMENT. REPLACED PER B737-900 SRM 51-40-02-0G.SDR DALA2026030901604Floor Support · corroded(LOG 1480560) CORROSION ON INTERCOSTAL RH SIDE BTW STA 767 TO STA 747 AT AFT CARGO COMPARTMENT. INTERCOSTAL RH SIDE BTW STA 767 TO STA 747 AT AFT CARGO COMPARTMENT WAS FRABRICATEED PER B737-900 DWG 146A7505-2 REV. A AND REPLACED PER B737-900 SRM 51-40-02-0G.SDR DALA2026030901603Floorbeam · corroded(LOG 1479152) CORROSION ON UPPER FLANGE BEAM STA 947 LBL 21 TO LBL 29 AT AFT PASSENGER CABIN (W2). UPPER FLANGE BEAM STA 947 LBL 8 TO LBL 60 AT AFT PASSENGER CABIN (W2) WAS REPAIRED PER B737-900 SRM 53-70-51-2R PROCEDURE 5 REPAIR 5 AND ER/A 632805-14 PRI REV. SDR DALA2026030901602Battery Pack · inoperative(LOG 8254571) DURING EMERGENCY LIGHT CHECK OF CABIN FOUND FLOOR PORXIMITY LIGHTS OUT AT ROW 28-32. REPLACED BATTERY PACK REF B737AMM 33-51-06. OPS CHECK GOOD.SDR DALA2026030401517Controller · faultedSHIP 3835 -ATB- RETURNED TO SEA DUE TO CAPTAINS L1 WINDOW ARCING AND CRACKED. CORRECTIVE ACTION: REPLACED L1 WINDOW AND WINDOW HEAT CONTROLLER. OPS AND LEAK CHECK NORMAL.SDR DALA2026030401519Battery Pack · inoperativeEMERGENCY LIGHTS INOP AT AFT LEFT EMERGENCY HATCH INTERIOR AND EXTERIOR, CEILING LIGHT AT ROW 24, AND LIGHT AFT OF LEFT WHEEL WELL. R/R EMERGENCY BATTERY PACK AT ROW 26ABC REF B737 AMM 33-51. ALL LIGHTS CHECK GOOD.SDR DALA2026030901601Plate · corroded(LOG 1477217) CORROSION ON LH SIDE PLATES FROM STA 500D TO STA 500L AT FWD CARGO COMPARTMENT. LH SIDE PLATE FROM STA 500D TO STA 500L AT FWD CARGO COMPARTMENT WAS REPLACED PER B737-900 SRM 51-40-02-0G.SDR DALA2026030901608Module · failed(LOG 8521544) EMERGENCY LIGHTS FROM MODULE M1676 INOP. RPLD MODULE M1676 AND BATT PACK AT 11DEF PER B737 AMM 33-51. OPS CKS GOOD.SDR DALA2026030901607Battery Pack · inoperativeSEVERAL EMERGENCY EXIT PATH LIGHTS INOP IN FWD GALLEY. REMOVED AND REPLACED THE ASSOCIATED BATTERY PACK IN THE FWD GALLEY CEILING PER B737 AMM 33-51.SDR DALA2026030501546Battery Pack · inoperative(LOG 8521545) EMERGENCY LIGHTS FROM MODULE M1695 INOPERATIVE. REPLACED MODULE M1695 AND BATT PACK AT 19DEF IAW AMM 33-51. OPS CKS GOOD.SDR DALA2026030501543Battery Pack · inoperative(LOG 8521543) DURING SVC CK FOUND NUMEROUS EMERGENCY PATH LIGHTS INOPERATIVE. REPLACED M2816 AMD M1673 IAW AMM 33-51. CHKD GOOD. REPLACED M1671 AND M2627 IAW AMM 33-51. OP CHKD GOOD.SDR DALA2026030501544Gust Lock · faulted(LOG 8380442) CATERING REPORTS ISSUE CLOSING R1 AT THE GATE. R & R DAMAGED GUST LOCK HOLD OPEN BUTTON ON R1 DOOR IAW AMM 52-41. OPS TESTED GOOD.SDR DALA2026030301446Plate · corroded(LOG 1474374) SEVERAL CORROSION ON RT SIDE PLATES FROM BS 500 TO 500L AT FWD CARGO COMPARTMENT. RH SIDE PLATES FROM STA 500 TO STA 500L AT FWD CARGO COMPARTMENT WAS REPLACED PER B737-900 SRM 51-40-02-0G.SDR DALA2026030301453Battery Pack · inoperative(LOG 8560486) ROW 20 LEFT OVERWING EMER EXIT SIGN INOPERATIVE. R & R M1670 BATTERY PACK & OPS CHECKED GOOD. IAW WDM 33-21.SDR DALA2026030301449Battery Pack · inoperative(LOG 8376077) EMERGENCY LIGHT ABOVE SEAT 30A INOP. REMOVED AND REPLACED BATTERY PACK M2626 PER BSSM 33-51-13. OVERHEAD EMERG LIGHT OPS CHECK GOOD.SDR DALA2026030301452Battery Pack · inoperativeON SCV CHECK FOUND EMERGENCY LIGHTS INOP ON CEILING. R & R BATTERY PACKS BETWEEN SEATS 10-11A AND SEATS 25-26A. OPS CHECKED GOOD, OK FOR SVC IAW AMM 33-51.SDR DALA2026031701850Inlet · gouged(LOG 1471009) WHILE IN THE SHOP FOR REPAIR, THE SUBJECT 737 INLET COWL (P/N 314-2100-4) WAS FOUND WITH GOUGE DAMAGE TO THE INNER FACE OF THE MOUNT RING (P/N 314-2134-3) AT APPROXIMATELY THE 5:00 POSITION. GOUGE REPAIRED PER ERA 631756-14AD.SDR DALA2026022701394Structure · corroded(LOG 1470144) AFT WET AREA CORROSION ON UPPER CHORD STA 986.5 MULTIPLE NUTPLATE HOLES CORRODED. PERFORMED REPAIR ON THE AFT WET AREA UPPER CHORD AT STA 986.5 RBL6 IAW B737-900 SRM 53-00-51-2R-1.SDR DALA2026022401314Battery Pack · inoperativeFOUND BATTERY PACK M1672, M1673, M2627, M1694 INOP DURING SVC WALKAROUND. R/R BATTERY PACKS M1672, M1673, M2627, M1694 PER B737 AMM 33-51. OPS CHECK GOOD.SDR DALA2026022401316Shutoff Valve · failedBRAKE/DE- DECLARED EMERGENCY INTO MSP DUE TO PARKING BRAKE LIGHT ILLUMINATED IN FLIGHT. MAINTENANCE REPLACED THE PARKING BRAKE SHUTOFF VALVE PER AMM 32-44 ON LOG PAGE 8499647.SDR DALA2026022401315Battery Pack · inoperativeCEILING EMERGENCY LIGHT INOP AT ROW 30. REMOVED AND REPLACED EMERGENCY LIGHT BATTERY IN CEILING AT ROW 29 PER AMM 33-51. OPS CHECKED GOOD.SDR DALA2026022401313Battery Pack · inoperativeFLOOR PROXIMITY EMERGENCY LIGHTS INOPERATIVE AT ROWS 22-27. REMOVED AND REPLACED BATTERY PACK ON POWER SUPPLY M01671 PER B737 AMM 33-51. OPS CHECKED GOOD.SDR DALA2026021701078Engine · overspeedDIV/IFSD/DE- FLIGHT CREW SHUT DOWN RIGHT ENGINE AND DIVERTED TO ELP DUE TO UNCOMMANDED OVERSPEED. REMOVED AND REPLACED NUMBER 2 ENGINE IAW AMDS W/C 7100-4423. OPS TEST GOOD.SDR DALA2026021801147Oven · smoke(LOG 8105730) SMOKE COMING FROM OVEN. REMOVED FWD GALLEY OVEN AND INSPECTED CONNECTORS FOR OVERHEATING NO EVIDENCE OF BURING DETECTED. SMELLS LIKE OVEN CLEANER RESIDUE. R/R OVEN AT FWD GALLEY IN REF TO B737 AMM 25-31. OPS NORMAL.SDR DALA2026021701074Battery Pack · inoperativeRT SIDE ROWS 33-37 AND R2 DOOR EMERGENCY LIGHTS INOPERATIVE. R & R BATTERY PACK IAW AMM 33-51. OPS CHKD GOOD.SDR DALA2026021701076Battery Pack · inoperativeEMERGENCY EXIT LIGHTS FROM ROW 11 TO 17 ARE INOPERATIVE. REPLACED BATTERY IAW AMM 33-51-06. OPS CHECKED GOOD.SDR DALA2026021701075Battery Pack · inoperativeFOUND FIRST CLASS EMERGENCY LIGHTS OUT. R & R FWD EMER LIGHT BATTERY PACK IAW AMM 33-51. OPS TESTED GOOD.SDR DALA2026021701073Battery Pack · inoperativeEMERGENCY EXIT LIGHTS BY DOOR 2L AND IN OVERHEAD ALONG AISLE ARE INOPERATIVE, AND FWD HALF OF ACFT TO ROW 5 ARE ALSO INOPERATIVE. FOUND THE BATTERY PACKS AT LOCATIONS M1675, M1673, M2816 BAD. REMOVED AND REPLACED BATTERY PACKS IAW AMM 33-51-06-960-805. OPS CHSDR DALA2026021301039Battery Pack · inoperativeDURING SERVICE CHECK FOUND R AFT EMERGENCY LIGHTS INOPERATIVE. R & R BATTERY PACK ON POWER SUPPLY M01672 IAW B737 AMM 33-51. LIGHTS TESTED OK.SDR DALA2026021301040Battery Pack · inoperativeEMERGENCY LIGHTS ON R2 DOOR INOPERATIVE. R & R R2 DOOR EMERGENCY BATTERY PACK IAW AMM 33-51. OPS CHK NORMAL.SDR DALA2026021000949Oil System · overservicedON TAKEOFF ROTATION CAPTAIN & FIRST OFFICER NOTICED A BURNED RUBBER ODOR AND DISAPATED IN 20 SECONDS. FOUND APU OIL OVERSERVICED. SERVICED APU OIL IAW AMM 12-13.SDR DALA2026021000946Power Supply · inoperativeL1 DOOR EMERGENCY LIGHTS INOPERATIVE. R & R POWER SUPPLY & BATTERY PACK IAW AMM 33-51 OPS CHECKED NORMAL.SDR DALA2026021000945Battery Pack · inoperativeOVERHEAD EMERGENCY LIGHT AT ROW 30ABC INOPERATIVE. REPLACED THE BATTERY PACK M2626 IAW AMM 33-51.SDR DALA2026020600872Battery Pack · inoperative(LOG 7919180) EMER LIGHTS INOP. REMOVED AND REPLACED 1L & R OVERWING BATTERY PACKS. OPS CK GOOD. STILL NEEDS L OVERWING & RT AFT BATTERIES. ALL PER B737 AMM 33-51.SDR DALA2026020500843Access Panel · corrodedWEAR AND CORROSION ON ANGLE OF EMPENAGE AREA SELMENT AREA OF ACCESS PANELS 321A, 323AL, 323BL, 323CL, 324AL, 323AR, 323BR, 323CR, 324AR AT VERTICAL STABILIZER. ANGLE OF EMPENAGE AREA SELMENT AREA OF ACCESS PANELS ON THE VERTICAL STABILIZER WERE REPLACED PER SSDR DALA2026020500842Battery Pack · inoperative(LOG 8028982) EMERGENCY EXIT AISLE LIGHTS OUT BETWEEN SEATS 28-32. REMOVED & REPLACED BATTERY PACK AT POWER SUPPLY FOR ROWS 28-32 (M2627) PER B737 AMM 33-51.SDR DALA2026020500841Plate · corrodedCORROSION ON SIDE PLATE RT BTW BS 500 TO 500A, 500A TO 500B, 500B TO 500C, 500D TO 500E, 500E TO 500F, 500F TO 500G, 500G TO 500H, 500H TO 500I, 500I TO 500J, 500J TO 500K, 500K TO 500L AT FWD CARGO COMPARTMENT. SIDE PLATES REPLACED PER B737-900 SRM 5SDR DALA2026020200783Floorbeam · corrodedCORROSION ON FLOORBEAM UPPER TEE BS 947 LBL 53, RBL 53, AND RBL 25. THE FLOORBEAM UPPER TEE REPAIRED IAW SRM 53-70-51-2R-5, PROCEDURE 5, REPAIR 5.SDR DALA2026020200780Battery Pack · no testDURING A SERVICE CHECK, LAST 5 ROWS AND AFT GALLEY EMERGENCY LIGHTS OUT. R & R THE BATTERY PACK M1673 IAW AMM 33-51. OPS CHKD GOOD.SDR DALA2026021601056Bezel · damagedSEAT 19D EMERGENCY LIGHT BEZEL DAMAGED. R & R SEAT 19D BEZEL ASSY IAW CMM 25-22-56 .SDR DALA2026020200779Baffle · corrodedCORROSION LOWER BAFFLES ON SIDE TRACK RT AT BS 500H AT NUT AREA AT FWD CARGO BAY. THE BAFFLE WAS REPLACED IAW SRM 51-40-02-0G.SDR DALA2026020200778Floorbeam · corrodedCORROSION ON FLOORBEAM UPPER TEE BS 947, RBL 53. THE FLOORBEAM UPPER TEE WAS REPAIRED IAW SRM 53-70-51-2R, PROCEDURE 8, REPAIR 8.SDR DALA2026020200776Floorbeam · corrodedCORROSION ON FLOORBEAM UPPER TEE (LOWER/ UPPER SURFACE) STA 986.5 RBL 43 (APPROX) AT W2. FLOORBEAM UPPER TEE WAS REPAIRED IAW SRM 53-70-51-2R-6, REPAIR 6.SDR DALA2026020200781Battery Pack · inoperativeCABIN EMERGENCY LIGHTS INOPERATIVE, ROWS 18 - 21, & ROWS 33-37, MID CABIN OVERHEAD EXIT SIGN, RT INTERIOR OVERWING EXIT SIGN LIGHT TOP & BOTTOM, R2 DOOR EMERGENCY EXIT LIGHTS. R & R BATTERY PACKS M1695 & M1672 IAW AMM 33-51. OPS CHKD NORMAL.SDR DALA2026020200782Battery Pack · inoperativeFWD GALLEY EMERGENCY LIGHTS AROUND L1 DOOR ARE OUT. R & R BATTERY PACK IAW AMM 33-51. OPS CHKD GOOD.SDR DALA2026020200775Battery Pack · inoperativeROWS 28-32 EMERGENCY LIGHTS INOPERATIVE. R & R THE BATTERY PACK AT 30R CEILING IAW AMM 33-51. OPS CHKD OK.SDR DALA2026012800665Filter · cloggedDURING DESENT AT OR NEAR IDLE POWER THROUGH 12000-10000FT, THERE WAS A CHEMICAL ODOR IN THE COCKPIT. FOUND RECIRC FAN FILTERS COGGLED. R & R THE CABIN RECIRC FILTERS IAW AMM 21-25. NO ODORS PRESENT. OK FOR SERVICE.SDR DALA2026012800663Transmitter · out of adjustPERFORMED GO AROUND & DECLARED AN EMERGENCY DUE TO LEADING EDGE FLAP TRANSIT LIGHT AND TRAILING EDGE FLAPS WOULD NOT GO TO 30. RESET & LANDED, FLAPS 15. PERFORMED FSEU BITE CHECK. NO FAULTS FOUND. PERFORMED LT & RT FLAP POSITION TRANSMITTER ADJUSTMENT IAW AMMSDR DALA2026012800662Controller · faultedPACK LIGHT ILLUMINATED IN FLT. FOLLOWED QRH. TRIP RESET WORKED, BUT TEMPORARY. ALSO HAD INTERMITTENT BURNING-CHEMICAL ODOR DURING DESCENT. R & R LT PACK TEMP CONTROLLER IAW AMM 21-61. OPS CHKD GOOD.
Back to Boeing 737-932ER