Boeing 747-282B
Service difficulty reports · 100
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '747282B' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '747282B' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR TWRA9716Battery Pack · dischargedEXIT SIGNS INOP AT R/2-L/3 MED. REMOVED AND REPLACED BATTERY PACK, PER MM 33-51-00. OPS CHECKED NORMAL. (M)SDR TWRA96374Light · inoperativeDURING DAILY CHECK, FOUND CEILING LIGHT INOP AT R4 DOOR, B AND C ZONE RIGHT SIDE CEILING LIGHT INOP. REMOVED AND REPLACED LIGHT ASSEMBLY. OPS CHECKED NORMAL PER MM 33-51-00. (M)SDR TWRA96372Battery Pack · dischargedDURING DAILY CHECK, FOUND EMERGENCY EXIT SIGN ADJACENT TO SEAT 65AC INOPERABLE. REPLACED EXIT SIGN BATTERY PACK. OPS CHECKED NORMAL PER MM 33-51-00. (X)SDR TWRA96353Light · inoperativeDURING DAILY CHECK, FOUND RIGHT SIDE AISLE CEILING EMERGENCY LIGHT INOP, ADJACENT TO SEAT 64 HJK. REMOVED AND REPLACED LIGHT ASSEMBLY AS PER MM 33-51-00. OPS CHECKED NORMAL. (M)SDR TWRA96341Light · inoperativeDURING DAILY CHECK, FOUND LIGHT STRIP AT SEAT 7A NOT ILLUMINATING. REPLACED STRIP AT SEAT 7A. OPS CHECKED NORMAL PER MM 33-59-00. (M)SDR TWRA96340Light · inoperativeR4 MED EMERGENCY BUSTLE LIGHT INOP. REPLACED EMERGENCY BUSTLE LIGHT ON R4 MED. OPS CHECK OK PER MM 33-51-00 PAGE 501. (M)SDR TWRA96339Light · inoperativeREAR GALLEY EMERGENCY FLOOR STRIP INOP. REPLACED REAR GALLEY FLOOR STRIP. OPS CHECK OK PER 33-51-01. (M)SDR TWRA96336Battery · dischargedMAIN CABIN CROSSOVER EXIT, EMERGENCY EVAC LIGHT INOP. IN C-ZONE, FORWARD RIGHT SIDE. REPLACED LIGHT ASSEMBLY BATTERY PACK. OPS CHECK NORMAL PER 33-51-00. (M)SDR TWRA96335Light · inoperativeNR 1 LEFT AND NR 4 LEFT MED UPPER BUSTLE EMERGENCY EVAC LIGHTS INOP REPLACE FAULTY BUSTLE LIGHTS. OPS CHECK OK PER MM 33-51-00. (M)SDR TWRA96334Wire · looseEVAC LIGHT STRIP OUT FROM 36 ABC TO 44 ABC AND IN FRONT OF 'L' LAV. CLEANED CONNECTIONS AND SECURED LOOSE WIRE. (M)SDR TWRA96332Battery · dischargedEVAC SYSTEM OVERWING LEFT SIDE. LAST TWO LIGHT ASSEMBLYS HAVE BOTH LIGHTS OUT. REPLACED BATTERY PACK. OPS CHECK OK PER MM 33-51-00. (M)SDR TWRA96328Engine · failedAFTER T/O 30 MINS IN FLT, WHILE CLIMBING THRU FL 350, LOST PWR ON NR 4 ENG. EGT DROPPED TO 480 DEG CELSIUS, N1 AND N2 APPROX 75 PERCENT, FUEL FLOW 300. NORMAL OIL PRESS WITH POSITIVE FUEL PRESS. ACCOMP UNSCHEDULED THRUST LOSS OR ABNORMAL RESPONSE TO THRUST SDR TWRA96331Light · inoperativeDURING DAILY CHECK, FOUND UPPER DECK EVAC FLOOR STRIP INOP. REPLACED EMERGENCY LIGHT STRIP IN UPPER DECK. OPS CHECKED OK PER MM 33-51-00. (M)SDR TWRA96323Light · inoperativeDURING DAILY CHECK, FOUND RIGHT SIDE OVERWING TO FUSELAGE NR 3 EVAC LIGHT ASSEMBLY. AFT BULB INOP. REMOVED AND REPLACED LIGHT ASSEMBLY. OPS CHECKED NORMAL PER MM 33-51-00. (M)SDR TWRA96315Slide · deployedINADVERTENTLY, L1 DOOR WAS OPENED WHILE IN AUTO MODE SLIDE DEPLOYED. PERFORMED INSPECTION PER 5-51-23. REPLACED SLIDE AT L21 DOOR PER TC 25-665-1L AND REPLACED DOOR ASSIST BOTTLE AT L1 DOOR PER WIC 25-615-4-2. OPERATIONAL CHECKED NORMAL. AIRCRAFT RETURN TOSDR 96ZZZM1483Door Assist Bott · emptyINADVERTENTLY, L1 DOOR WAS OPENED WHILE IN AUTO MODE SLIDE DEPLOYED. PERFORMED INSPECTION PER 5-51-23. REPLACED SLIDE AT L21 DOOR PER TC 25-665-1L AND REPLACED DOOR ASSIST BOTTLE AT L1 DOOR PER WIC 25-615-4-2. OPERATIONAL CHECKED NORMAL. AIRCRAFT RETURN TOSDR TWRA96314Wire · brokenDURING DAILY CHECK, FOUND UPPER DECK FLOOR STRIP EVAC LIGHT IS INOP. REPLACED WIRE FROM POWER SOURCE TO EVAC STRIP. OPS CHECKED NORMAL PER MM 33-59-00. (M)SDR TWRA96280Light · inoperativeDURING DAILY CHECK, FOUND FLOOR EVAC EGRESS LIGHT STRIP INOP BETWEEN SEATS ROW 20ABC. REPLACED BROKEN POWER STRIP. OPS CHECKED GOOD PER MM 33-51-00. (M)SDR TWRA96271Light · inoperativeDURING DAILY CHECK, FOUND NEAR NR 4L MED GALLEY FLOOR EMERGENCY LIGHT INOP. REMOVED AND REPLACED EMERGENCY LIGHT STRIP. OPS CHECKED NORMAL AS PER MM 33-51-00. (M)SDR TWRA96270Light · inoperativeDURING DAILY CHECK, FOUND NEAR NR 2 MED GALLEY FLOOR EMERGENCY LIGHT INOP. REMOVED AND REPLACED LIGHT. OPS CHECKED NORMAL AS PER MM 33-51-00. (M)SDR TWRA96269Light · inoperativeDURING DAILY CHECK, FOUND 20H THROUGH 26H FLOOR EMERGENCY LIGHTS ARE INOP. REMOVED AND REPLACED EMERGENCY LIGHT STRIP 20H THROUGH 26H. OPS CHECKED NORMAL AS PER 33-51-00. (M)SDR TWRA96263Bulb · failedDURING DAILY CHECK, FOUND RIGHT WING NR 3 OVERWING EMERGENCY LIGHT ONE BULB INOP. RELAMPED, OPS CHECKED OK PER MM 33-51-00 PAGE 501. (M)SDR TWRA96217Connector · looseDURING DAILY CHECK, FOUND FLOOR EVAC EGRESS LIGHT STRIP INOP AT SEAT 35C. FOUND CONNECTOR LOOSE, RE-SEATED AND SECURED. OPS CHECK OK PER MM 33-51-00. (M)SDR TWRA96215Wire · inoperativeDURING DAILY CHECK, FOUND FLOOR EVAC EGRESS LIGHT STRIP AT 'E' GALLEY INOP. REPAIRED HARNESS, OPS CHECKED OK PER MM 33-51-00. (M)SDR TWRA96214Bulb · failedDURING DAILY CHECK, FOUND RIGHT OUTSIDE LOWER MOST EMERGENCY LIGHT INOP. RELAMPED, OPS CHECK GOOD, PER MM 33-51-00. (M)SDR TWRA96226Lights · inoperativeDURING DAILY CHECK, FOUND EMERGENCY OVERWING LIGHTS INOP, (BOTH SIDES). REPAIRED WIRES, OPS CHECKED GOOD PER MM 33-51-00. (M)SDR TWRA96225Wire · brokenDURING DAILY CHECK, FOUND R1 MED EMERGENCY LIGHT INOP. REPAIRED WIRE, OPS CHECKED GOOD PER MM 33-51-00. (M)SDR TWRA96224Strip · inoperativeDURING DAILY CHECK, FOUND C-ZONE EMERGENCY LIGHT (R/S) INOP. REPLACED B-ZONE GALLEY STRIP. OPS CHECKED NORMAL PER MM 33-51-00. (M)SDR TWRA96223Wire · brokenDURING DAILY CHECK, FOUND 5L MED EMERGENCY LIGHT INOP. REPAIRED WIRING. OPS CHECKED OK PER IAW 33-51-00. (M)SDR TWRA96201Connector · looseDURING DAILY CHECK, FOUND RIGHT AISLE WITH NO EVAC LIGHTS FROM 22 KJA THROUGH 26 KJH. FOUND LOOSE CONNECTOR. TIGHTEN CONNECTOR. LIGHT OPS CHECK OK PER MM 33-51-00. (X)SDR TWRA96198Connector · defectiveDURING DAILY CHECK, FOUND ENTIRE U/D EVAC LIGHT INOPERATIVE. FOUND BAD CONNECTOR FOR FEEDER. REPLACED CONNECTOR. EMERGENCY LIGHT OPS CHECK NORMAL PER MM 33-51-00. (X)SDR TWRA96192Strip · inoperativeDURING DAILY CHECK, FOUND UPPER DECK EGRESS LIGHT IS INOP AND LEFT OF 'Z' ZONE EGRESS LIGHTS ARE INOP. REMOVED AND REPLACED STRIP IN UPPER DECK AND REPAIRED BROKEN WIRE IN 'A' ZONE PER MM 33-51-00. (M)SDR TWRA9651Battery Pack · dischargedDURING DAILY SERVICE, FOUND CREW DOOR EMERGENCY EXIT SIGN AND SILLLIGHTS INOPERATIVE DURING OPS CHECK. REPLACED BATTERY AT OVERHEAD CREW DOORFOR SILL LIGHTS AND RELAMPED EXIT SIGN WITH 700 517-14 BULBS. BOTH LIGHTSTEST OK. (M)SDR TWRA9633Switch · shortedON APPROACH, ELECTRICAL BURNING SMELL WAS NOTICED IN COCKPIT AFTER LEFT OUTBOARD LANDING LIGHT WAS TURNED ON DURING TAXI, LIGHT COULD NOT BE TURNED OFF WITH SWITCH. INSPECTED AREA AND FOUND SWITCH SHORTED AND FIRST INCH OF WIRE TO SWITCH BURNED. CIRCUIT BREASDR TWRA9632Engine · malfunctionedON APPROACH AND DURING TAXI IN TO PARKING SPOT, A SMELL OF SMOKE WAS DETECTED COCKPIT GALLEY POWER WAS OFF SMELL MOSTLY CAME FROM CAPTAINS SIDE (EYEBALL VENTS). NR 2 ENGINE WAS REPLACED AND R/U CHECK OK, ALL 3 PACKS WERE RUN. OPS CHECK OK. NO SMOKE IN COCKPSDR TWRA9621Girt Bar · stuckAT DEPARTURE L-3 DOOR WOULD NOT GO INTO AUTOMATIC POSITION. INVESTIGATION FOUND GIRT BAR HANGING UP. GIRT BAR WAS FREED. OPS CHECK, IAW MM 52-10-00. (M)SDR TWRA9617Battery Pack · dischargedEGRESS LIGHTS INTERMITTENTLY COMING ON AT TIMES (BUSTLE LT AT R-1 DOOR AND EXIT LT AT R-1 DOOR). REPLACED BATTERY PACK AT BUSTLE LT, R-1 DOOR AND AT EXIT LT, R-1 DOOR. (M)SDR TWRA9616Light Strips · shortedEMERGENCY EXIT LIGHTS WILL NOT EXTINGUISH WITH OVERHEAD CONTROL SWITCH IN 'ARM' POSITION. REPLACED SHORTED LIGHT STRIPS ON FLOOR. (M)SDR TWRA9614Strip Light · brokenDURING GROUND CHECKS, FOUND SEVERAL EMERGENCY LIGHTS INOP. FOUND STRIP LIGHT WIRE BROKEN. TROUBLESHOT AND CORRECTED INOP EMERGENCY LIGHTS. 1 REPLACED 2 SECTIONS OF STRIP LIGHT. (M)SDR TWRA9613Battery Pack · dischargedDURING GROUND CHECKS, FOUND SEVERAL EMERGENCY LIGHTS INOP. FOUND WATER UNDER GALLEY MAT, TROUBLESHOT AND CORRECTED INOP EMERGENCY LIGHTS. REPLACED BATTERY PACK, EMERGENCY CEILING LIGHT ABOVE ROW 59HJK. (M)SDR TWRA9612Lock Assy · missingL-5 DOOR, PRIOR TO DEPARTURE MIA, FOUND GIRT BAR SLIDE BRACKET MISSING (LOCK ASSY). MAINTENANCE INSTALLED NEW SLIDE BRACKET. (X)SDR TWRA9571Evc · wornDURING CLIMB-OUT, FLIGHT CREW EXPERIENCED AN OIL SMELL IN THE COCKPIT AND CABIN. SMELL CLEARED AFTER POWER WAS REDUCED. REPLACED NR 2 ENGINE'S ENGINE VANE CONTROL. (X)SDR TWRA9561Coalescer · dirtyDURING TAKEOFF WITH PACKS TURNED ON, CABIN FILLED WITH BLUE SMOKE FOR A SHORT PERIOD OF TIME. MAINTENANCE AT JFK CHECKED ALL FOUR ENGINES FUEL HEATERS AND BLEED SYSTEMS. ALL FOUND OK. COALESCER BAGS WERE REPLACED IAW 21-51-05. ALSO, CLEARED BLOCKAGE IN THESDR TWRA9546Eel Wiring Strip · shortedD-ZONE EGRESS LIGHTS RIGHT SIDE INOPERATIVE. REPLACED SHORTED DAMAGED EGRESS STRIP, REPAIRED FLOOR WIRING, OPS CHECK OK. (M)SDR TWRA9545Eel Wire · brokenC-ZONE EGRESS LIGHTS RIGHT SIDE INOPERATIVE. REPLACED BROKEN GROUND WIRE AT BATTERY PACK, OPS CHECK OK (M)SDR TWRA9544Eel Wire · shortedUPPER DECK EGRESS LIGHTS AT SEATS AND COCKPIT INOPERATIVE. REPLACED SHORTED EGRESS FEED. REPLACED WIRING TO EXIT EGRESS SIGN IN COCKPIT. OPS CHECK OK. (M)SDR TWRA9541Eel Battery Pack · dischargedAT R4 DOOR PASSAGEWAY BOTH EXIT SIGNS (FWD AND AFT) ARE INOPERATIVE. REPLACED BATTERY PACK AFT OF R4 DOOR EMERGENCY LIGHTS, OPS CHECK OK. (M)SDR TWRA9529Light Strip · inoperativeDURING AN A-SERVICE AT GAMCO, FOUND EMERGENCY LIGHT STRIPS AT SEATS 26 ABC TO 32 ABC, 57 ABC TO 65 ABC AND 25 KJ TO 20 KJ, NOT COMING ON. REPAIRED LIGHT STRIPS, OPERATIONAL CHECK OKAY. (X)SDR TWRA9507Eel Batt Pack · inoperativeDURING DAILY SERVICE, EMERGENCY LIGHTS AT R1 MAIN ENTRY DOOR CAME ON AND OFF. REPLACED BATTERY PACK AT R1 MED, AND REPLACED LIGHT ASSEMBLY. OPS CHECK OK. (W)SDR TWRA9506Eel Battery Pack · dischargedDURING LOADING OF A/C, COULD NOT EXTINGUISH EMERGENCY EXIT LIGHTS. RESEATED CANNON PLUG AT ALL EXIT LIGHTS, REPLACED BATTERY PACK AT L-5 MAIN ENTRY DOOR, REPAIRED GROUND PLUG R484. SYSTEM OPS CHECK OKAY. (X)
Back to Boeing 747-282B