Boeing 747-422
Service difficulty reports · 9,801
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '747422' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '747422' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2010052401744Light · inoperativeSEAT 56H FLOOR PROX EMERGENCY LIGHT STRIP INOPERATIVE. REPLACED, OPS NORMAL.SDR UALA2010052401743Lamp · inoperativeEMERGENCY EXIT LIGHTS INOP. DOOR 2 GALLEY AREA CENTER AND RIGHT LOWER FWD WALL. RELAMPED. OPS. CKS. NORMALSDR UALA2010052401746Unknown · odorF/A REPORTED SLIGHT ELECTRICAL BURNING ODOR IN U-D GALLEY AREA ON TAXI IN. SEEMED TO DISSIPATE. OP CKD ALL LIGHTS AND RESET GALLEY PWR AND CHILLERS, NO INDICATION OF BURNING ODOR, POSSIBLY FOOD CART PROBLEM. OP CKD, NFF.SDR UALA2010052401753Light · smokeAFT PORT OVRHD FLOURESCENT LIGHT BUZZING AND HAS ELEC. SMOKE SMELL ON UPR DECK.SDR UALA2010052401738Cover · looseEMERGENCY LIGHT STRIP TOP OF UPPER DECK STAIRS LOOSE FROM WALL. SECURED PLASTIC COVER ON STAIR EMERGENCY LIGHT. LIGHTS OPS CHK OKAY.SDR UALA2010052101720Connector · saturatedEMERGENCY EXIT LIGHTS INOP. SEAT ROWS 45 THRU 53 LT, DOOR 4 LT FWD EXIT SIGN, DOOR 4 RT AFT. EXIT SIGN, LOWER WALL EMERGENCY LIGHT ACROSS DOOR 4 LT, AND DOOR 4 GALLEY AREA LOWER WALL EMERGENCY LIGHT. THIS IS A REPETITIVE PROBLEM IN THIS SPECIFIC AREA ON 84XX SDR UALA2010052101719Lamp · inoperativeEMERGENCY EXIT LIGHTS INOP DOOR 5 RT FWD AND AFT SILL. RELAMPED. OPS, CKS NORMAL.SDR UALA2010052101717Light · missingLOW TECH CREW REPORTED EMERGENCY LIGHT BAR ON SEAT 57C MISSING. REPLACED LIGHT ASSY, OPS CKS OK.SDR UALA2010052001705Socket · burnedAFT PORT OVERHEAD FLOURESCENT LIGHT BUZZING AND HAS ELECTRICAL SMOKE SMELL ON UPPER DECK. FOUND CEILING LIGHT SOCKET BURNED. BEHIND ROW 17JK PORT SIDE. BALLAST CONNECTOR REMOVED AND STOW. LIGHT SOCKET NOT AVAIL. CLEANED FLUORESCENT LAMP SOCKETS AT MOST AFTSDR UALA2010051901680Window · overheatedCREW REPORTED THAT L3 WINDOW BECAME TOO HOT THAT UNABLE TO TOUCH. FOUND 5 & HALF INCH LENGTH AND 2 INCH WIDTH OF MILKY WHITE FILM CAN BE SEEN ON THE FWD OF THE WINDOW. 2 INCH DELAMINATION ALONG THE MILKY FILM. THE WINDOW NEEDS TO BE CHANGED IAW MM. USED JAL NSDR UALA2010051701656Apu · faultyAPU WOULDN'T START. 2 ATTEMPTS. SPOOLED UP TO 14PCT THEN SHUTDOWN. SPOOLED UPTO 14PCT THEN SHUTDOWN. APU NO LIGHT OFF. DUE TO CHRONIC ASD-OPS OK & ODOR IN CABIN. REPLACED APU, OPS CK'S GOOD.SDR UALA2010051401639Wire · shortedCAPT ADJUSTING SUNSHADE INADVERTANTLY HIT WIRE ON TERMINAL BLOCK OF WINDOW 1L CAUSING SPARKS. CB FOR WINDOW HEAT POPPED AT THE SAME TIME, POSSIBLE LOOSE WIRE ON TERMINAL BLOCK. FOUND SHORT JUMPER WIRES ON TRIPLEX WINDSHIELDS NOT CONNECTED TERMINAL FOR BOTH SDR UALA2010060101857Wire · damagedEMERGENCY EXIT EMERGENCY LIGHT INOP. SEAT ROW 48 RT. REPAIRED BROKEN WIRE. OP CKS OKAY.SDR UALA2010051101605Line · leakingFOUND 1 GALLON OF FUEL IN APU-STAB SHROUD SUMP DRAIN. APU FWD FUEL LINE LEAKING AT CONSTANT RATE WITH APU RUNNING. DISCONNECTED APU SHROUD IN AFT PIT.2EA LOCATIONS PER MM. EVIDENCE OF FUEL AT BOTH LOCATION S. ALL APU FUEL LINE SECTIONS NEED REPLACING. RMV'D ASDR UALA2010051001576Feeder Cable · faultySEAT ROW 45-53 EMERGENCY SEAT LIGHTS STRIPS INOP, DOOR 4 LT & 4 RT EXIT LIGHTS INOP, AFT GALLEY BY DOOR 4 LT & 4 RT GALLEY EMERGENCY LIGHT STRIPS INOPERATIVE. REPLACED FEED IN POWER CABLE AND JUMPER CABLE FROM FEED IN TO GALLEY EMERGENCY STRIP LIGHTS, OP CHECSDR UALA2010051001575Connector · brokenSEAT 45 HJK EMERGENCY SEAT EMERGENCY LIGHT INOPERATIVE. REPAIRED BROKEN WIRE AT CONNECTOR UNDER SEAT, OP CHECKS GOOD.SDR UALA2010051001574Lamp · inoperativeDOOR 2LT & 2RT GALLEY BOTTOM EMERGENCY LIGHTS INOPERATIVE. RELAMPED GALLEY EMERGENCY LIGHTS, OP CHECKS GOODSDR UALA2010051201609Wire · damagedNR 4 ENG HAS NO OIL PRESSURE INDICATION, BREAKER D4 WAS POPPED. FOUND MULTIPLE WIRES BURNED AND ARCING ON WIRE HARNESS 10 INCHES AFT OF TRANSMITTER. BUNDLE WAS DAMAGED BY COOLING VALVE MOUNTED ON INBOARD SIDE OF FAN COWL. WIRE HARNESS IS FOR OIL PRESSURE TRSDR UALA2010050701558Structure · damagedTAIL STRIKE ON TAKEOFF, RTFL. NO DAMAGE IN FUSELAGE AREA FWD OF STA 2658. ALL DAMAGE CONTAINED AND DOCUMENTED FROM STA 2658 THRU TO STA 2764 IN LWR AREA REFER SMC 5 THRU 17 FOR FINDINGS. FERRIED FOR REPAIRS. REPLACED DAMAGED FRAME AT STA 2742. HORZ STAB ACCESSDR UALA2010050401508Pushrod · out of adjustDOOR 5R ARMING HANDLE FORCES HIGH AND GIRT BAR NOT ENGAGING FITTINGS FULLY. SUPPLEMENTAL DATA UPDATE GIRT BAR SLIDERS DO NOT TRAVEL FULLY INTO FLOOR FITTINGS AND FABRIC LANYARD FROM SLIDE IS NOT PROPERLY ROUTED UNDER GIRT BAR HOLDING STRAP. CORRECTED FABRIC LSDR UALA2010050301483Lamp · inoperativeDOOR 5L GALLEY WALL EMERGENCY LIGHT INOP. REPLACED EMERGENCY LAMP, OP CK NORMAL.SDR UALA2010050301482Battery Pack · faultyMAIN GALLEY WALL EMERGENCY LIGHT FWD AND S SIDE WALL INOP. REPLACED BATTERY PACK. CLEANED AND RESECURED CONNECTOR. OPS CK NORMAL.SDR UALA2010050301481Battery Pack · inoperativeEMERGENCY CEILING LIGHT FROM ROW 35 THROUGH 45 LT INOP. REPLACED BATTERY PACK. OPS CK NORMAL.SDR UALA2010050301480Battery Pack · inoperativeEMERGENCY CEILING LIGHT ROW 35 THROUGH 45 RT INOP. REPLACED BATTERY PACK. OP CK NORMAL.SDR UALA2010050301479Battery Pack · inoperativeEMERGENCY LIGHT ROW 45 THROUGH 53 LT INOP. REPLACED BATTERY PACK ABOVE DR 4LT . CLEANED AND RESECURED EMERGENCY LIGHT CONNECTOR. OPS CK NORMAL.SDR UALA2010050301478Light · inoperativeDR2 LT EMERGENCY BUSSEL LIGHT INOPERATIVE. REPLACED LIGHT ASSY, CHECKS OK.SDR UALA2010050301476Light · shortedEMERGENCY LIGHT AT 2 RT THE LOWER UNIT IS BROKEN OFF THE WALL. REPLACED SHORTED EMERGENCY LIGHT SECTION. OPS ARE NORMAL.SDR UALA2010050301475Light · shortedEMERGENCY LIGHT AT ECONOMY GALLEY IN AISLE AT 4LT AND IN GALLEY UNIT PROPER ARE INOPERATIVE. REPLACED SHORTED EMERGENCY LIGHT SECTION. OPS ARE NORMAL.SDR UALA2010050301474Light · shortedEMERGENCY LIGHT AT 4R AFT EXIT SIGN IS INOPERATIVE. REPLACED SHORTED EMERGENCY LIGHT SECTION. OPS ARE NORMAL.SDR UALA2010050301473Light · shortedEMERGENCY LIGHT AT 4LT FWD SIDE EXIT SIGN INOPERATIVE. REPLACED SHORTED EMERGENCY LIGHT SECTION. OPS ARE NORMAL.SDR UALA2010050301472Light · shortedEMERGENCY LIGHT AT 45ABC THRU 53ABC ARE INOPERATIVE. REPLACED SHORTED EMERGENCY LIGHT SECTION. OPS ARE NORMAL.SDR UALA2010050301460Connector · unsecureEMERGENCY LIGHT ROW 40 RT INOP. RESECURED EMERGENCY LIGHT CONNECTOR. OP CK NORMAL.SDR UALA2010050301459Lamp · inoperativeEMERGENCY CEILING LIGHT ROW 7 RT INOPERATIVE. RELAMPED. OPS CK NORMAL.SDR UALA2010043001451Lamp · inoperativeLT OVERWING EMERGENCY LIGHT EXIT LIGHT OUT. REPLACED LAMP. OP CK GOOD IAW MM 33-51-03 PB 200. BY MECH 9602880 AND INSP KAA059 ON NON ROUTINE JC 330023.SDR UALA2010043001450Light · inoperativeEMERGENCY DOOR SLIDE LIGHT INOP AT L4 DOOR. REPLACED LIGHT. OP CHECK GOOD IAW MM 33-51-06. BY MECH 0012666 AND INSP KAA 059 ON NON ROUTINE 330025.SDR UALA2010043001449Switch · brokenEMERGENCY LIGHT SWITCH BROKEN AT L1 DOOR ATTENDANT SEAT. REPLACED SWITCH. OP CK GOOD IAW MM 33-51-00 PB500, WDM 33-51-11 PAGE 1.SDR UALA2010043001456Valve · leakingNR 2 ENGINE, REPLACE FUEL DISTRIBUTION VALVE IAW SMC ENGINE CONTROLLER DUE TO FUEL LEAKING FROM ENGINE CASE. REPLACED DISTRIBUTION VALVE. LEAK NO LONGER DETECTED.SDR UALA2010042901431Wire · saturatedEMERGENCY EXIT LIGHTS INOP, SEAT ROWS 45 THRU 52 LT, DOOR 4 LT FWD EXIT SIGN, DOOR 4 RT AFT EXIT SIGN, LOWER WALL EMERGENCY LIGHT ACROSS DOOR 4 LT, AND DOOR 4 GALLEY AREA LOWER WALL EMERGENCY LIGHT. REPLACED AND REPAIRED SHORTED EMERGENCY LIGHT WIRING DUE TO SDR UALA2010042901430Light · inoperativeEMERGENCY EXIT LIGHT INOP, LOWER WALL ACROSS DOOR 1 RT. REPLACED LIGHT ASSY, OPS CKS NORMAL.SDR UALA2010042901429Light · inoperativeEMERGENCY EXIT LIGHT INOP SEAT ROW 50 LT. REPLACED LIGHT ASSY, OPS CKS NORMAL.SDR UALA2010042901428Lamp · inoperativeEMERGENCY EXIT LIGHT INOP. CEILING SEAT ROW 45 LT. RELAMPED. OPS. NORMAL.SDR UALA2010042901427Lamp · inoperativeEMERGENCY EXIT LIGHT INOP. DOOR 1 LEFT AFT SILL LIGHT. RELAMPED. OPS CKS NORMAL.SDR UALA2010042901426Link · out of adjustBEFORE PUSH BACK F/A REPORT UPPER DECK RT ESCAPE DOOR SLIDE HANDLE WON'T GO ARM POSITION. INSP-CHECK TO INCLUDE (ARM AND DISARM), ALSO REF SVC TIP (RIGGING). REPORT & CORRECT ANY FAULTS. INSP MECHANISM. DOOR SLIDE DEPLOYMENT HOOK AND SLIDE DEPLOYMENT LINK NOTSDR UALA2010042901432Light · missingSEAT 9J, AFT AISLE EMERGENCY LIGHT ASSY MISSING. REPLACED LIGHT ASSY, OPS NORMAL.SDR UALA2010042801413Skin · crackedAFT CARGO DOOR CUTOUT UPPER FWD CORNER: 2 EACH CRACKS EXTENDING FROM FASTENER HOLE. MAJOR REPAIR ACCOMPLISHED: CUT OUT SKIN, MFG AND INSTALLED REPAIR PARTS IAW SRM 53-60-01 REPAIR 3 TYPE III.SDR UALA2010042801412Bottle · reads lowNEW LT UD SLIDE HAS LWR PSI ON FWD BOTTLE. REPLACED FWD BOTTLE AND SECURED SAME.SDR UALA2010042701402Light · inoperativeEMERGENCY EXIT LIGHT INOP AFT CREW REST AREA CEILING INBOARD LAMP. RELAMPED, OPS CHECKS NORMAL.SDR UALA2010042701401Connector · unsecureEMERGENCY EXIT EEL LIGHT INOP SEAT ROW 45 LEFT. SECURED CONNECTOR, OPS CHECKS NORMAL.SDR UALA2010042701400Connector · unsecureEMERGENCY EXIT EEL LIGHT INOP SEAT ROW 43 LEFT. SECURED CONNECTOR, OPS CHECKS NORMAL.SDR UALA2010042701399Light · inoperativeEMERGENCY EXIT LIGHT INOP DOOR 2 GALLEY AREA LOWER LEFT WALL. RELAMPED, OPS NORMAL.
Back to Boeing 747-422