SDR UALA2009102603332Lamp · inoperativeEMERGENCY EXIT LIGHT INOP. ROW 52 LEFT CEILING. RELAMPED. OPS. NORMAL.SDR UALA2009102603331Lamp · inoperativeEMERGENCY EXIT LIGHT INOP. ROW 57 LEFT CEILING. RELAMPED. OPS. NORMAL.SDR UALA2009102303313Light · inoperativeCROSS AISLE EEL LIGHT INOP BETWEEN DOORS 2L AND 2R, RT LIGHT INOP. RELAMPED, CHECKS OKAY.SDR UALA2009102303312Battery · dischargedCEILING EEL LIGHTS INOP ZONE E ROWS 46RL AND ROWS 60RL. REPLACED BATTERY, CHECKS OKAY.SDR UALA2009102303311Feeder Cable · contaminatedEEL LIGHTS INOP FWD EXIT 4L, AFT EXIT 4R, MAIN GALLEY FWD CROSS ISLE LEFT SIDE, SEATS 45L THRU 53L. THIS IS A COMMON PROBLEM ON 84XX 747'S COMING OUT OF OVERHAUL. REMOVED WATER COVERING FEEDER CABLES.SDR UALA2009102303309Connector · dirtyEMERGENCY EXIT LIGHTS AREA DOOR 1L FLICKER ON-OFF. CLEANED CONNECTOR & TESTED. OP CHECKS NORMAL.SDR UALA2009102203294Cable · defectiveWHEN TESTING THE EEL LIGHT SYS FOUND ROW 45C THRU 53C THE SIDE OF SEAT EEL LIGHTS INOP WITH THE GALLEY CROSS-AISLE INOP. REPLACED CABLE ASSEMBLY AT CROSS AISLE. EEL OPS CHECKS OKAY.SDR UALA2009102203293Spring · brokenDOOR 1L EEL LIGHTING FLASHES ON AND OFF. FOUND SPRING ON EMERGENCY LIGHT SWITCH GUARD AT 1L JUMPSEAT BROKEN. REPLACED SWITCH GUARD.SDR UALA2009102003267Power Supply · dischargedDOOR 1L EMERGENCY LIGHTS INTERMITTENT. REPLACED DOOR 1L EMERGENCY LIGHT POWER SUPPLY M7915. CHECK OK.SDR UALA2009102003266Power Supply · dischargedEMERGENCY EXIT LIGHT 1L FLASHES ON INTERMITTENTLY. REPLACED M7915 POWER SUPPLY FOR DOOR 1L EMERGENCY LIGHTS, CHECK OK.SDR UALA2009101603246Light · inoperativeCEILING EEL LIGHT INOP ROW 49L. RELAMPED, OPS NORMAL.SDR UALA2009101603245Feeder Cable · contaminatedEMERGENCY EXIT EEL LIGHTS INOP, SEAT ROWS 45 THRU 51 LEFT, DOOR 4L FWD EXIT SIGN, DOOR 4R AFT EXIT SIGN. LOWER WALL EEL ACROSS DOOR 4L, AND DOOR 4 GALLEY AREA LOWER WALL EEL. THIS IS A REPETITIVE PROBLEM IN THESE SPECIFIC AREAS ON 84XX AIRCRAFT COMING OUT OFSDR UALA2009101903262Oxygen Bottle · low pressureARRIVAL CHECK FOUND CREW O2 ONLY 1570 PSI. CREW OXYGEN BOTTLE REPLACED AND PRESSURE CHECKED AT 1850 PSI.SDR UALA2009101503236Stringer · crackedSTRINGER 44L DAMAGED STA 440-480. MAJOR REPAIR ACCOMPLISHED. SPLICED IN NEW STRINGER SECTION.SDR UALA2009101403224Feeder Cable · contaminatedEMERGENCY LIGHTS IN AFT GALLEY INOP. REPAIRED WET EMERGENCY LIGHT STRIPS AND LAMPS.SDR UALA2009101403223Feeder Cable · contaminatedEMERGENCY LIGHTS INOP FROM DOOR 4L ABC TO 4 ROWS AFT. REPAIRED WET AND CORRODED WIRES.SDR UALA2009101403233Servo · faultyYOKE SHOOK VIOLENTLY W- AUTOPILOT ENGAGED DURING FINAL APPROACH WITH FLAPS 20 +GEAR UP. ALL WIRING CHECKS OKAY. REPLACED CENTER FLIGHT CONTROL COMPUTER AS A PRECAUTION. REPLACED CENTER ELEVATOR AUTOPILOT SERVO. ACCMP'D CHECK OF AUTOPILOT SYSTEM. ALL AFDS SDR UALA2009101303218Light · improper partSEAT 24C EEL LIGHT WRONG TYPE. REPLACED LIGHT ASSY, CHECKS OKAY.SDR UALA2009101203199Wire · brokenWHILE ACP TEST FOR INBOARD FLAP COAST BREAK FOUND LEFT OUTBOARD FLAP INDICATION NOT READING. FOUND EXISTING FAULT LEFT OUTBOARD RVDT FAIL. MSG 27636. STARTED PERFORMING FIM 27-58 TASK 820. ISOLATED EACH FCU NO HELP. REPLACED LEFT O/B TRAILING EDGE FLAP RVSDR UALA2009101203191Support · damagedEMERGENCY LIGHT SUPPORT DAMAGED, LOCATED JUST AFT OF DOOR 1R. LIGHT IS LWR ASSY OF TWO, THAT ARE MOUNTED ON THE LAV CORNER. ACP INTERIM REPAIR. BOTH EMERGENCY LIGHTS ARE WORKING, AT THIS LOCATION. INTERIM REPAIRS MADE USING QUICK SET EPOXY AND PIT TAPE. EMERSDR UALA2009101203185Lamp · inoperativeDURING EMERGENCY LIGHT TEST FOUND CROSS AISLE IS INOP AT DOOR 4L AND THRU THE AFT GALLEY. REPLACED LAMP STRIP, EMERGENCY LIGHT OPS CHECKS OKAY.SDR UALA2013040402208Skin · corrodedNUMEROUS AREAS OF CORROSION FOUND ON FUSELAGE INTERIOR SKIN CROWN AREA AT BS 1480 BETWEEN STR 12L & 12R. CORROSION WAS REMOVED & SKIN BLENDED OUT TO 10:1 RATIO WITH SEVERAL AREAS OF MATERIAL LOSS GREATER THAN ALLOWED BY SRM LIMITS. SKIN WAS TREATED & PRIMED SDR UALA2009101203184Light · inoperativeEEL INOP AT DOOR 4R, AISLE WALL NEXT TO GALLEY. REPLACED LIGHT L9025.SDR UALA2009101203190Skin · corrodedNUMEROUS AREAS OF CORROSION FOUND ON FUSELAGE INTERIOR SKIN CROWN AREA AT BS 1480 BETWEEN STR 12L & 12R. MAJOR REPAIR ACCOMPLISHED. CORROSION WAS REMOVED & SKIN BLENDED OUT TO 10:1 RATIO WITH SEVERAL AREAS OF MATERIAL LOSS GREATER THAN ALLOWED. SKIN WAS TRESDR UALA2009101203183Light · inoperativeEEL LIGHTS ARE INOP FROM DOOR 4L TO ROW 45 AND GALLEY WALL ALSO EXIT LIGHTS AT DOOR 4L AND 4R. ORDERED LIGHT ASSYS. REMOVED AISLE LIGHT & DISCONNECTED FEEDER ALL OTHER LIGHTS NOW OKAY. REPLACED EEL LIGHTS L9025, 3 EA.SDR UALA2009100903176Door Frame · crackedDOOR 1R UPPER FRAME CRACKED AT 2 EACH FASTENER HOLES AT GATE ATTACH POINT, 9TH & 10TH HOLES FROM FWD END. MAJOR REPAIR ACCOMPLISHED. INSTALLED REPAIR ANGLE, FILLER & CLIP.SDR UALA2009100903175Door Frame · crackedDOOR 1L UPPER FRAME CRACKED AT GATE 2 EACH ATTACH HOLES, 9TH & 10TH FROM FWD END. MAJOR REPAIR ACCOMPLISHED. INSTALLED REPAIR ANGLE, FILLER & CLIP.SDR UALA2009100903174Connector · unsecureEMERGENCY EXIT LIGHT INOP CEILING SEAT ROW 4 RIGHT. SECURED CONNECTOR, OPS CHECKS NORMAL.SDR UALA2009100903173Light · inoperativeEMERGENCY EXIT LIGHT INOP DOOR 5 LEFT BUSTLE. REPLACED LIGHT ASSY, OPS CHECKS NORMAL.SDR UALA2009100903172Connector · unsecureEMERGENCY EXIT EEL LIGHT INOP SEAT ROW 54 LEFT. SECURED CONNECTOR, OPS CHECKS NORMAL.SDR UALA2009100903171Light · inoperativeEMERGENCY EXIT LIGHT INOP DOOR 3 LEFT BUSTLE. REPLACED LIGHT ASSY, OPS CHECKS NORMAL.SDR UALA2009100903170Skin · corrodedFUSELAGE INTERNAL SKIN HAS CORROSION AROUND LT TOILET VENT EXIT, BS 2080-2100, STR 35L-36L. MAJOR REPAIR ACCOMPLISHED. INSTALLED EXTERNAL DOUBLER & TRIPLER REPAIR.SDR UALA2009100903169Battery Pack · dischargedEMERGENCY EXIT LIGHT INOP ABOVE DOOR 1R. REPLACED BATTERY PACK, OP CHECK OKAY.SDR UALA2009100903168Light · inoperativeDOOR 2R & 5L EMERGENCY EVAC SLIDE ILLUMINATION LIGHTS INOP. RELAMPED, LIGHTS CHECK OKAY.SDR UALA2009100803162Light · disconnectedEMERGENCY EXIT EEL LIGHT INOP LOWER WALL ACROSS DOOR 4 RIGHT. FOUND EEL NOT CONNECTED, RECONNECTED AND OP CHECKED NORMAL.SDR UALA2009100803161Light · inoperativeEMERGENCY EXIT LIGHT INOP CEILING ROW 22 LEFT. REPLACED BULB AND OP CHECKED NORMAL.SDR UALA2009100803160Light · inoperativeEMERGENCY EXIT LIGHT INOP IN FLIGHT DECK. RELAMPED, OPS NORMAL.SDR UALA2009100803159Light · inoperativeEMERGENCY EXIT LIGHTS INOP UPPER DECK CEILING BETWEEN DOORS, FWD AND AFT LIGHT ASSY'S. RELAMPED, OPS NORMAL.SDR UALA2009100803157Control Panel · no testOVERHEAD SQUIB NR 1 TEST SWITCH INTERMITTENT AND STICKS. COULD NOT GET TEST NR 1 TO TEST AT ALL. REPLACED SQUIB TEST PANEL. OPS TEST NORMAL.SDR UALA2009100803156Wire Harness · brokenEEL LIGHTS INOP AT AFT GALLEY SIDE WALL. FOUND BROKEN WIRE UNDER SEAT 35ABC. REPLACED UNDER SEAT HARNESS AND LEAD IN HARNESS TO GALLEY LIGHTS. OPS NORMAL.SDR UALA2009100803155Fuse · faultyRT WING ESCAPE PATH HAS THE FIRST TWO LIGHTS INOPERATIVE. REPLACED FUSE IN PWR SUPPLY AT DOOR 3R. OPS NORMAL.SDR UALA2009100503130Tank · emptyCREW REPORTS NO WATER PRESSURE UPON TAKEOFF. FOUND WATER TANK GAUGE READING 000 PERCENT QTY, SERVICED TANK TO OVERFILL, FOUND NO LEAKS. A/C OKAY FOR SERVICE.SDR UALA2009100503121Tension Tie · crackedTENSION TIE CRACKED AT 2 FASTENER HOLES, BS 1160 STR 8L - 9L. MAJOR REPAIR ACCOMPLISHED. INSTALLED REINFORCING REPAIR.SDR UALA2009100503120Light · damagedFOUND EEL LIGHT DAMAGED AT LAV CORNER, JUST FWD OF DOOR 2R. ACP INTERIM REPAIR TO LWR EEL LIGHT, ON LAV CORNER, JUST AHEAD OF DOOR 2R. BOTH EEL LIGHTS ON CORNER WORK. RE-EPOXIED LIGHT STANDOFFS TO LAV AND REPLACED WIRE COVER TRIM PIECE. LIGHT SECURE AND OPSDR UALA2009100503119Tension Tie · crackedTENSION TIE FASTENER HOLE CRACKED AT BS 1180 STR 9L-10L. MAJOR REPAIR ACCOMPLISHED: INSTALLED REINFORCING REPAIR.SDR UALA2009100503118Light · looseEMERGENCY LIGHT IS LOOSE AT 37C. SECURED LIGHT ASSY.SDR UALA2009100503117Failsafe · crackedFAIL-SAFE CHORD CRACKED AT 2 FASTENER HOLES AFTER OVER-SIZING. LOCATED AT BS 1140 STR 9R-10R. MAJOR REPAIR ACCOMPLISHED: SPLICED IN NEW SECTION OF CHORD.SDR UALA2009100503106Light · inoperativeAFT GALLEY EEL LIGHTING CROSS AISLE IS INOP. REPLACED EEL LAMP ASSY, EEL OPS CHECKS OKAY.SDR UALA2009100503105Power Cable · faultyDURING EEL LIGHT TEST FOUND THAT SIDE OF SEATS EEL LIGHTS ARE NOT WORKING FROM ROWS 45ABC THRU ROW 53ABC. REPLACED POWER CABLE AT CROSS AISLE, EEL OPS CHECK OKAY.SDR UALA2009100503104Cover · damagedDAMAGE TO DOOR 1R AFT LWR EEL LT ASSY, WHICH IS MOUNTED ON THE LAV CORNER, JUST AFT OF THE DOOR. ACP INTERIM REPAIR, BOTH EEL LIGHTS IN THIS LOCATION WORK. FOR BROKEN BASE ASSY AND WIRE COVER BETWEEN FLOOR AND LWR EEL ASSY, AND BETWEEN LWR AND UPPER EEL ASSY
Back to Boeing 747-422