Boeing 747-422

Service difficulty reports · 9,801

Newest first. General aviation reporting is voluntary.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE aircraft_model_key = '747422'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR 2008UALA05551Lamp · inoperativeSEAT 5F AFT FLOOR EMERGENCY LIGHT INOP. FOUND FAULTY LAMP STRIP. REPLACED LAMP STRIP, OP CHECK GOOD. AC OK FOR SERVICE.Aug 31, 2008 · N180UA · Boeing 747422 · Emergency LightingSDR 2008UALA05550Lamp · inoperativeSEAT 2J AFT EMERGENCY LIGHT FLOOR INOP. FOUND FAULTY LAMP. REPLACED LAMP STRIP, OP CHECK GOOD. AC OK FOR SERVICE.Aug 31, 2008 · N180UA · Boeing 747422 · Emergency LightingSDR 2008UALA05536Battery Pack · inoperativeTHE A-ZONE LT COLUMN EMERGENCY LIGHT INOP. REPLACED BATTERY PACK, OP CHECK OKAY.Aug 30, 2008 · N179UA · Boeing 747422 · Emergency LightingSDR 2008UALA05519Oxygen Bottle · lowCREW OXYGEN SYSTEM LOW. CREW COMMENTS: CREW O2 NEEDS SERVICING. *S/D* SUSPECT PRE FLIGHT CHECKS. SERVICED SYSTEM TO FULL. AC OK FOR SERVICE.Aug 27, 2008 · N127UA · Boeing 747422 · Crew Oxygen SystemSDR UALA2008111305487Unknown · smokeSMOKE APPEARED IN AFT GALLEY. PER FLIGHT ATTENDANT, SAW A SLIGHT AMOUNT OF SMOKE COMING FROM AREA NEAR AFT LEFT COFFEE WARMER. OPERATED ALL AFT GALLEY EQUIPMENT. CHECKED AREA. NO SMOKE DETECTED. GALLEY 428 NR 181 GETS TOO HOT. OPS OK. NO OTHERS DEFECTS Aug 26, 2008 · N171UA · Boeing 747422 · Air Distribution SystemSDR 2008UALA05487Unknown · odorSMOKE APPEARED IN AFT GALLEY.Aug 26, 2008 · N171UA · Boeing 747422 · Air Distribution SystemSDR 2008UALA05493Coffeemaker · smokeAFT GALLEY SMOKE APPEARING. OCCURRED JUST PRIOR TO LANDING AND ELECTRICAL POWER REMOVED FROM GALLEY AS A PRECAUTION. PER FLIGHT ATTENDENTS, THEY SAW A SMALL AMOUNT OF SMOKE COMING FROM AREA NEAR AFT LEFT COFFEE WARMER. OPERATED ALL AFT GALLEY EQUIPMENT. CHECAug 26, 2008 · N171UA · Boeing 747422 · Buffet/GalleysSDR UALA2008111305459Connector · chafedELECTRICAL ODOR MAIN DECK GALLEY. RTFL. FOUND PIGTAIL CONNECTOR WIRE BUNDLE FOR P56 AND P57 LOCATED ON BACK WALL WHERE GALLEY OVEN CARTS GO TO BE CHAFED IN TWO PLACES. REPLACED THE WIRE BUNDLE FOR P56 TO P57. OVERHEAD GALLEY LIGHT IN MID GALLEY INOP. REPLAug 25, 2008 · N104UA · Boeing 747422 · Equipment/Furnishings WiringSDR UALA2008111305461Flap · puncturedLEFT INBOARD FORE FLAP LEADING EDGE HAS A LARGE PUNCTURE. FOUND PUNCTURED FORE FLAP DAMAGED FROM TIRE TREAD. REPAIRED DAMAGED SPAR PER SRM 51-70-12, REPAIR 1. REPAIRED LOWER PANEL ON R61502 PER SM-80-57-53-17-JD. REPAIRED L/E BULLNOSE ON R61505 PER SRM 57-Aug 25, 2008 · N117UA · Boeing 747422 · Trailing Edge FlapsSDR 2008UALA05452Battery Pack · inoperativeEMERGENCY LIGHT FROM ROW 55 TO 61 INOP. REPLACED BATTERY PACK. OP CHECK NORMAL.Aug 25, 2008 · N173UA · Boeing 747422 · Emergency LightingSDR 2008UALA05453Battery · inoperativeEMERGENCY EXIT LIGHT DOOR 5 LT INOP. REPLACED BATTERY. OP CHECK NORMAL.Aug 25, 2008 · N173UA · Boeing 747422 · Emergency LightingSDR 2008UALA05461Skin · puncturedLEFT INBOARD FORE FLAP LEADING EDGE HAS A LARGE PUNCTURE. REMOVED LEFT INBOARD FORE FLAP. COMPLETE FORE FLAP INSTALLATION FROM ITEM 3 PAGE 407 TO COMPLETION.Aug 25, 2008 · N117UA · Boeing 747422 · Trailing Edge FlapsSDR 2008UALA05459Unknown · odorELECTRICAL ODOR MAIN DECK GALLEY. RTFL.Aug 25, 2008 · N104UA · Boeing 747422 · Air Distribution SystemSDR 2008UALA05454Connector · unsecureEMERGENCY LIGHT AFT GALLEY BOTTOM WALL LT INOP. RESECURED EMERGENCY LIGHT CONNECTOR. OP CHECK NORMAL.Aug 25, 2008 · N173UA · Boeing 747422 · Light System WiringSDR 2008UALA05451Lamp · inoperativeEMERGENCY CEILING LIGHT ROW 44 LT INOP. RELAMPED, OP CHECK NORMAL.Aug 24, 2008 · N173UA · Boeing 747422 · Emergency LightingSDR 2008UALA05421Lamp · inoperativeDOOR 2 RIGHT SILL EMERGENCY LIGHT IS INOP. RELAMPED. CHECKS NORMAL.Aug 23, 2008 · N117UA · Boeing 747422 · Emergency LightingSDR 2008UALA05424Lamp · inoperativeDOOR 3 LEFT SILL EMERGENCY LIGHT IS INOP. FOUND BURNED OUT LAMP. REPLACED LAMP, OP CHECK GOOD. AC OK FOR SERVICE.Aug 23, 2008 · N117UA · Boeing 747422 · Emergency LightingSDR 2008UALA05422Lamp · inoperativeSEAT 55HJK EMERGENCY LIGHT IS INOP. RELAMPED, CHECKS NORMAL.Aug 23, 2008 · N117UA · Boeing 747422 · Emergency LightingSDR 2008UALA05423Lamp · inoperativeDOOR 3 LEFT CEILING 1 EA EMERGENCY LIGHT IS INOP. RELAMPED, CHECKS NORMAL.Aug 23, 2008 · N117UA · Boeing 747422 · Emergency LightingSDR 2008UALA05429Battery · inoperativeLEFT OVERWING 4 EACH EMERGENCY LIGHT IS INOP. REPLACED BATTERY. CHECKS NORMAL.Aug 23, 2008 · N117UA · Boeing 747422 · Emergency LightingSDR 2008UALA05425Cable · unsecureLEFT SIDE A ZONE EMERGENCY LIGHT, SEATS 1A-5A IS INOP. FOUND UNDER SEAT CABLE OFF. RECONNECTED, CHECKS NORMAL.Aug 23, 2008 · N117UA · Boeing 747422 · Emergency LightingSDR UALA2008111305393Smoke Detector · false activationSMOKE ALARM IN FLT ATT CREW REST AREA WENT OFF 2X ON TAXI IN. ALSO LOUD NOISE HEARD BENEATH 5L. DOOR 5 SMOKE DETECT CB CYCLED, SYS RESET, ALL OPS NORMAL. UNABLE TO REPRODUCE LOUD NOISE UNDER 5L. NO FAULT FOUND.Aug 22, 2008 · N107UA · Boeing 747422 · Smoke DetectionSDR 2008UALA04375Light · missingA 4A AFT EEL STRIP MISSING. *S/D* FOUND MISSING LIGHT STRIP. REPLACED LIGHT STRIP, OP CHECK GOOD. AC OK FOR SERVICE.Aug 22, 2008 · N107UA · Boeing 747422 · Emergency LightingSDR 2008UALA05415Fire Bottle · malfunctionedBTL LOW CARGO B MSG DISPLAYED AND DISCHARGE LIGHT ON OVERHEAD PANEL ILLUMINATED, NO FWD OR AFT LIGHT ON. REPLACED FIRE "B" BOTTLE.Aug 22, 2008 · N171UA · Boeing 747422 · Extinguishing SystemSDR 2008UALA04374Power Supply · intermittentEMERGENCY EXIT AND PATH LIGHTS AT DOORS 2L-2R IN BUSINESS CLASS COME ON INTERMITTENTLY. *S/D* REPLACED POWER SUPPLY M6002 AT DOOR 2R.Aug 22, 2008 · N120UA · Boeing 747422 · Emergency LightingSDR 2008UALA05394Bearing · wornFOUND METAL DEPOSIT ON NR 1, 1.5 AND 2 BEARING CHIP DETECTORS AND MAIN OIL FILTER. WILL REQUIRE NR 4 ENG REPLACEMENT. ENGINE WAS REPLACED AT LAX PRIOR TO FURTHER FLIGHT. SHOP TEARDOWN FOUND THE NR 1 BEARING WITH A BALL COMPLETELY MISSING. THE BALL HAD FAIAug 22, 2008 · N127UA · Boeing 747422 · Engine (Turbine/Turboprop)SDR 2008UALA05393Smoke Detector · malfunctionedSMOKE ALARM IN FLT ATT CREW REST AREA WENT OFF TWICE ON TAXI IN. ALSO LOUD NOISE HEARD BENEATH 5L- :DOOR 5 SMOKE DETECT C/B CYCLED, SYS RESET, ALL OPS NORMAL. UNABLE TO REPRODUCE LOUD NOISE UNDER 5 L.Aug 22, 2008 · N107UA · Boeing 747422 · Smoke DetectionSDR 2008UALA04336Lamp · inoperativeEMERGENCY LIGHT ROW 4A INOP. *S/D* REPLACED LAMP, OP CHECKS OKAY.Aug 19, 2008 · N174UA · Boeing 747422 · Emergency LightingSDR 2008UALA04335Lamp · inoperativeEMERGENCY CEILING LIGHT ABOVE ROW 32 RT INOP. *S/D* RELAMPED, OP CHECK NORMAL.Aug 19, 2008 · N174UA · Boeing 747422 · Emergency LightingSDR 2008UALA04334Lamp · inoperativeEMERGENCY LIGHT ROW 4F INOP. *S/D* RELAMPED, OP CHECK NORMAL.Aug 19, 2008 · N174UA · Boeing 747422 · Emergency LightingSDR 2008UALA04353Guard · unsecureEEL LIGHTING AT ROWS 6-8 RT SIDE TURN OFF AND ON RANDOMLY. FOUND LOOSE LIGHT GUARD. SECURED LIGHT GUARD OP CHECK GOOD. ACFT OK FOR SERVICE.Aug 19, 2008 · N120UA · Boeing 747422 · Emergency LightingSDR 2008UALA04296Bottle · lowCREW OXYGEN PX READ 1560 PSI ON STS PAGE. REPLACED CREW OXYGEN CYLINDER. ACFT OK FOR SERVICE.Aug 18, 2008 · N175UA · Boeing 747422 · Crew Oxygen SystemSDR 2008UALA04300Feeder Cable · inoperativeEMERGENCY LIGHT AFT GALLEY LOWER WALL LT INOP. *S/D* REPLACED EEL CABLE. OP CHECK NORMAL.Aug 16, 2008 · N178UA · Boeing 747422 · Light System WiringSDR 2008UALA04299Feeder Cable · damagedEMERGENCY LIGHT LT FROM ROW 45 TO 53 INOP. *S/D* REPLACED EEL CABLE. OP CHECK NORMAL.Aug 16, 2008 · N178UA · Boeing 747422 · Light System WiringSDR 2008UALA04298Light · inoperativeEMERGENCY LIGHT ROW 56 RT INOP. *S/D* RELAMPED EMERGENCY LIGHT, OP CHECK NORMAL.Aug 16, 2008 · N178UA · Boeing 747422 · Emergency LightingSDR 2008UALA04297Connector · unsecureDOOR 4 RT AFT EXIT LIGHT INOP. FOUND LOOSE CONNECTION. SECURED CONNECTION OP CHECK GOOD. ACFT OK FOR SERVICE.Aug 16, 2008 · N178UA · Boeing 747422 · Light System WiringSDR 2008UALA04311Light · missingSEAT 3J EEL MARKER MISSING. *S/D* REPLACED EEL LIGHT ASSY, CHECK OKAY.Aug 15, 2008 · N116UA · Boeing 747422 · Emergency LightingSDR 2008UALA04280Battery · inoperativeEMERGENCY LIGHT AT DOOR 2R FLASHES INTERMITTENTLY. *S/D* REPLACED POWER SUPPLY BATTERY ASSY, OP CHECKS OKAY.Aug 15, 2008 · N120UA · Boeing 747422 · Emergency LightingSDR 2008UALA04288O-Ring · leakingCREW OXYGEN PRESSURE READ LOW. SUSPECT LEAKING O-RING. REPLACED O2 BOTTLE OP AND LEAK CHECK GOOD. ACFT OK FOR SERVICE.Aug 15, 2008 · N182UA · Boeing 747422 · Crew Oxygen SystemSDR 2008UALA04282Light · unsecureSEAT 5A EEL LT STRIP NEEDS TO BE SECURED. FOUND LOOSE LIGHT ASSEMBLY. SECURED LIGHT ASSEMBLY OP CHECK GOOD. ACFT OK FOR SERVICE. Aug 15, 2008 · N173UA · Boeing 747422 · Emergency LightingSDR 2008UALA04285Light · unsecureSEAT 5J EMERGENCY LIGHT IS LOOSE. FOUND LIGHT UNSECURE. SECURED EMERGENCY LIGHT. Aug 14, 2008 · N180UA · Boeing 747422 · Emergency LightingSDR 2008UALA04259Bottle · lowLOW BOTTLE.Aug 13, 2008 · N171UA · Boeing 747422 · Escape SlideSDR 2008UALA04255Lamp · inoperativeSEAT 47 HJK EMERGENCY LIGHT INOP. RELAMPED, CHECKS OKAY.Aug 12, 2008 · N195UA · Boeing 747422 · Emergency LightingSDR 2008UALA04243Brake · seizedLANDING GEAR NO RETRACT. RTFL. FOUND RT BLG FWD LT BRAKE SEIZED. REPLACED BRAKE. NO SHOP DATA FOR ROOT CAUSE. Aug 12, 2008 · N175UA · Boeing 747422 · Landing Gear Retraction/Extension SystemSDR 2008UALA04227Connector · inoperativeEMERGENCY LIGHT ROW 55 LT INOP. FOUND LOOSE CONNECTOR. RE-SECURED EEL CONNECTOR. OP CHECK NORMAL.Aug 11, 2008 · N196UA · Boeing 747422 · Light System WiringSDR 2008UALA04231Connector · unsecureEMERGENCY LIGHT ON WALL FWD OF LAV 110 DOOR 2L INOP. RESECURED EMERGENCY LIGHT CONNECTOR. OP CHECK NORMAL.Aug 11, 2008 · N196UA · Boeing 747422 · Light System WiringSDR 2008UALA04230Connector · unsecureEMERGENCY LIGHT ON LT WALL LAV 110 DOOR 2L INOP. *S/D* RESECURED EMERGENCY LIGHT CONNECTOR. OP CHECK NORMAL.Aug 11, 2008 · N196UA · Boeing 747422 · Light System WiringSDR 2008UALA04229Lamp · inoperativeEMERGENCY CEILING LIGHT TOP OF STAIRS UPPER DECK INOP. RELAMPED, OP CHECK NORMAL.Aug 11, 2008 · N196UA · Boeing 747422 · Emergency LightingSDR 2008UALA04228Lamp · inoperativeEMERGENCY CEILING LIGHT ABOVE ROW 16 INOP. RELAMPED, OP CHECK NORMAL.Aug 11, 2008 · N196UA · Boeing 747422 · Emergency LightingSDR 2008UALA04226Lamp · inoperativeEMERGENCY LIGHT ROW 44LT INOP. RELAMPED, OP CHECK NORMAL.Aug 11, 2008 · N196UA · Boeing 747422 · Emergency Lighting
Back to Boeing 747-422