SDR 2008UALA03568Lamp · inoperativeLT OVERWING EMERGENCY EXIT LIGHTS INOP, 1ST & 2ND FROM FWD. FOUND BURNED OUT LAMPS AND FUSES. REPLACED LAMPS AND FUSES OP CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA03569Light · brokenSEAT 4J EMERGENCY LIGHT BROKEN. FOUND BROKEN LIGHT ASSEMBLY. REPLACED LIGHT ASSEMBLY OP CHECKED GOOD. AC OK FOR SERVICE.
SDR 2008UALA03549Lamp · inoperativeOVERWING EMERGENCY LIGHT RT TOP FWD INOP. FOUND BURNED OUT LAMP. REPLACED LAMP OP CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA03548Light · inoperativeOVERWING EMERGENCY LIGHT LT SECOND FROM TOP FWD INOP. FOUND FAULTY LIGHT ASSEMBLY. REPLACED LIGHT ASSEMBLY OP CHECKED OK. AC OK FOR SERVICE.SDR 2008UALA03547Light · inoperativeOVERWING EMERGENCY LIGHT NOT WORKING. LOCATION: LEFT SIDE 2ND FROM TOP. FOUND FAULTY LIGHT ASSEMBLY. REPLACED LIGHT ASSEMBLY OP CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA03546Lamp · inoperativeEMERGENCY LIGHT ROW 2J AFT INOP. FOUND FAULTY LAMP. REPLACED LAMP OP CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA03550Engine · bird ingestionBIRDSTRIKE TO NR 2 ENGINE. RTFL. CREW SUSPECTED A BIRDSTRIKE, AND SHUT THE ENGINE DOWN AS A PRECAUTION. BORESCOPE INSPECTION REVEALED NO CORE DAMAGE; BIRDSTRIKE DAMAGE CONFINED TO FAN BYPASS AREA. FIVE FAN BLADES WERE BENT FORWARD, WITH MINOR NICKS TO OTHERSDR 2008UALA03494Connector · looseEMERGENCY LIGHT AFT GALLEY RT BOTTOM WALL INOP. FOUND LOOSE CONNECTION. SECURED CONNECTION, OP CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA03493Connector · looseEMERGENCY LIGHT ROW 48 LT INOP. FOUND LOOSE CONNECTION. SECURED CONNECTION, OP CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA03477Lamp · inoperativeEEL INOP: SEAT 56 RT. FOUND BURNED OUT LAMP. REPLACED LAMP, OP CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA03476Lamp · inoperativeEMERGENCY LIGHT INOP: CEILING ROW 13. FOUND BURNED OUT LAMP. REPLACED LAMP, OP CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA03475Lamp · burned outEMERGENCY LIGHT INOP: COCKPIT CEILING. FOUND LAMP BURNED OUT. REPLACED LAMP, OP CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA03461Light · inoperativeWALL EEL INOP: AFT OF ROW 8 LT AT COAT CLOSET. FOUND LIGHT ASSEMBLY TO BE FAULTY. REPLACED LIGHT ASSEMBLY OP CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA03474Light · brokenEMERGENCY EEL LIGHT BROKEN OFF SEAT 55C. REPLACED EEL LIGHT ASSY. OP CHECKED OKAY.SDR 2008UALA03411Light · inoperativeEMERGENCY LIGHT INOP: AFT CREW REST STAIRS ILLUM. SUSPECT FAULTY LIGHT ASSEMBLY. REPLACED LIGHT ASSEMBLY, OP CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA03409Connector · unsecureWALL EEL INOP: AFT GALLEY FWD WALL. FOUND LOOSE CONNECTION. SECURED CONNECTION, OP CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA03405Lamp · inoperativeEMERGENCY LIGHT INOP: DOOR 2L FWD SILL. FOUND BURNED OUT LAMP. REPLACED LAMP, OP CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA03383Connector · unsecureWALL EEL INOP: BETWEEN MID LAVS CROSS AISLE. FOUND LOOSE CONNECTION. SECURED CONNECTION, OP CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA03410Light · inoperativeEMERGENCY LIGHT INOP CEILING ROW 12. REPLACED LAMP.SDR 2008UALA03408Light · inoperativeSEAT EEL INOP ROW 58 LT. RELAMPED EMERGENCY LIGHT, OP CHECK NORMAL.SDR 2008UALA03407Light · inoperativeSEAT EEL INOP 49 LT. RELAMPED EMERGENCY, OP CHECK NORMAL.SDR 2008UALA03406Light · inoperativeWALL EEL INOP LT SIDE LAV 111. RELAMPED EMERGENCY LIGHT, OP CHECK NORMAL.SDR 2008UALA03394Light · inoperativeEMERGENCY LIGHT INOP ROW 1J FWD SECTION. RELAMPED EMERGENCY LIGHT. OP CHECK NORMAL.SDR 2008UALA03431Light · missingTHE 3A EEL STRIP MISSING. FOUND LIGHT STRIP MISSING. REPLACED LIGHT STRIP, OP CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA03347Feeder Cable · damagedEEL INOP AT CLOSET WALL AFT OF DOOR 1L. FOUND EEL INOP AT CLOSET WALL AFT OF DOOR 1L. REPLACED BULB AND CABLE, OP CHECK OK REF MM 33-51-12. AC OK FOR SERVICE.SDR 2008UALA03310Floorbeam · damagedUPPER DECK FLOORBEAM UPPER CHORD AT BS 860 & 880, LBL 7 1.5, TOTAL OF 3 FASTENER HOLES MISDRILLED. PLUGGED FASTENER HOLES REF SRM 51-40-02. AC OK FOR SERVICE.SDR 2008UALA03304Wire · shortedFOUND SEATS 4J, 5J SIDE WALL AND CEILING LIGHT INOP. FOUND WIRE SHORTED BETWEEN STOW BIN AND STRUCTURE ABOUT TWO FEET AFT OF BALLAST AT SPLICE, MARKED. RESPLICED WIRE W2885-015- 20, REPLACED BALLAST AND REPROGRAMMED OEU. LIGHTS OPERATE NORMAL. AC OK FOR SSDR 2008UALA03303Light · inadequateTHE 58 ABC EMERGENCY PATH LIGHTS ARE INADEQUATE. FOUND LIGHT ASSEMBLY PROTRUDING. REPLACED LIGHT ASSEMBLY. AC OK FOR SERVICE.
SDR 2008UALA03317Light · inoperativeRIGHT OVERWING EMERGENCY EXIT LIGHTS INOP, 1ST, 2ND, 3RD FROM FWD. RELAMPED EMERGENCY LIGHT, OPERATION CHECKS OKAY.SDR 2008UALA03280Light · inoperativeEEL INOP, SEAT 51C. RELAMPED EMERGENCY LIGHT, OP CHECKED OKAY.SDR 2008UALA03238Lamp · inoperativeEMERGENCY EXIT FLOOR LIGHT OUT AT COCKPIT DOOR. FOUND FAULTY LAMP. REPLACED LAMP, OP CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA03233Warning System · malfunctionedWARNING & MONITORING INSTRUMENTS UNRELIABLE. RTFL.SDR 2008UALA03243Warning System · activatedBOTH EICAS SCREENS CONSTANTLY CYCLING RANDOM WARNINGS AND MESSAGES. RTFL.SDR 2008UALA03239Light · missingSEAT 4E EMERGENCY LIGHT STRIP BY SIDE OF SEAT IS MISSING. FOUND LIGHT STRIP MISSING. REPLACED LIGHT STRIP, OP CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA03234Connector · looseTHE 5A AFT EEL LIGHT DETACHED. FOUND LOOSE CONNECTION. SECURED CONNECTION, OP CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA03216Light · inoperativeEMERGENCY LIGHT ROW 50 ABC INOP. RELAMPED EMERGENCY LIGHT. OP CHECK NORMAL.SDR 2008UALA03215Light · inoperativeEMERGENCY LIGHT ROW 4A AFT INOP. RELAMPED EMERGENCY LIGHT. OP CHECK NORMAL.SDR 2008UALA03166Bulb · burned outDOOR 3 RIGHT FWD SILL EMERGENCY LIGHT IS INOP. FOUND BURNED OUT BULB. REPLACED BULB, OP CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA03162Battery Pack · inoperativeRIGHT SIDE C-ZONE SEAT EMERGENCY LIGHTS IS INOP. SUSPECT FAULTY BATTERY. REPLACED BATTERY, OP CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA03140Connector · looseSEAT 50HJK EMERGENCY LIGHT INOP. *S/D* FOUND LOOSE CONNECTION. SECURED CONNECTION, OP CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA03138Wire Harness · faultySEAT 49ABC EMERGENCY LIGHT INOP. *S/D* SUSPECT WIRE HARNESS. REPLACED WIRE HARNESS, OP CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA03172Frame · damagedFWD PIT FRAME STA 720 HAS DAMAGE. SUSPECT GROUND EQUIPMENT DAMAGE. INSTALLED MANUFACTURED PARTS PER SRM 51-70-12, DETAIL III. AC OK FOR SERVICE.SDR 2008UALA03100Oxygen Bottle · low pressureCREW OXYGEN BOTTLE PRESSURE LOW. REPLACED WITH SERVICEABLE CREW OXYGEN CYLINDER AND THEN LEAK CHECKED GOOD PER AMM 12-15-08 P 301. AC OK FOR SERVICE.SDR 2008UALA03099Light · looseSEAT 3J EEL LIGHT LOOSE.SDR 2008UALA03084Connector · looseEMERGENCY EXIT EEL LIGHT INOP AT SEAT 4F FWD AND AFT LIGHT ASSY'S. *S/D* FOUND LOOSE CONNECTION. SECURED CONNECTION, OP CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA03083Connector · looseEMERGENCY EXIT EEL LIGHT INOP AT SEAT 5A FWD AND AFT LIGHT ASSY'S. *S/D* FOUND LOOSE CONNECTION. SECURED CONNECTION, OP CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA03082Connector · disconnectedEMERGENCY EXIT EEL LIGHT INOP AT SEAT 5F FWD AND AFT LIGHT ASSY'S. *S/D* FOUND LOOSE CONNECTION. SECURED CONNECTION, OP CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA03081Lamp · inoperativeEMERGENCY EXIT LIGHT INOP AT DOOR 3 RIGHT FWD SILL LIGHT. *S/D* FOUND BURNED OUT LAMP. REPLACED LAMP OP CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA03090Lamp · burned outLT OVERWING EMERGENCY EXIT LIGHTS INOP, 1ST AND 2ND FROM FWD POSITION. FOUND FAULTY LAMPS AND FUSE'S. REPLACED FUSE'S AND LAMPS OP CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA03089Lamp · inoperativeDOOR 5L DOOR MOUNTED EMERG EXIT LIGHT TURNS OFF AFTER A FEW SECONDS OF OPERATION. FOUND FAULTY LAMP. REPLACED LAMP OP CHECKED GOOD. AC OK FOR SERVICE.