SDR 2007UALA00804Light · inoperativeDOOR SLIDE EMERGENCY LIGHT NOT ON DOOR R2. REPLACED WITH SERVICEABLE SLIDE EMER LT (DR R2, R4). ON GRD, DOOR R2, R4 SLIDE EMERGENCY LIGHT OP CHECKED NORMAL. READY FOR SERVICE.Mar 19, 2007 · Boeing 747422 · Emergency LightingSDR 2007UALA00803Light · inoperativeDOOR 5 CREW REST ROOM EMERGENCY LIGHT NOT ON (STAIRWAY AREA). REPLACED WITH SERVICABLE EMERGENCY LIGHT ASSY AND THEN OP CHECKED ON GROUND. SYSTEM OP CHECKED NORMALLY.Mar 19, 2007 · Boeing 747422 · Emergency LightingSDR 2007UALA00809Connector · looseEEL BETWEEN LAVS AT DOORS 3R & 3L XAISLE INOP. SECURED LAMP CONNECTOR. EEL TESTED OK.Mar 18, 2007 · N128UA · Boeing 747422 · Light System WiringSDR 2007UALA00808Light · inoperativeDOOR 1R EMERGENCY SLIDE LIGHT INOP. REPLACED LIGHT ASSY. TESTED GOOD FOR SERVICE.Mar 18, 2007 · N128UA · Boeing 747422 · Emergency LightingSDR 2007UALA00807Lamp · inoperativeEEL AT 2A & 4F FWD, 5A AFT, 33C, & 44 RIGHT ARE INOP. RELAMPED EACH OF THE FIVE POSITIONS. ALL OP CHECKED OK FOR SERVICE.Mar 18, 2007 · N128UA · Boeing 747422 · Emergency LightingSDR 2007UALA00806Lamp · inoperativeEMERGENCY CEILING LIGHT AT ROW 4 RIGHT INOP. RELAMPED. OP CHECKED GOOD FOR SERVICE.Mar 18, 2007 · N128UA · Boeing 747422 · Emergency LightingSDR 2007UALA00787Unknown · unknownDOOR 3L WILL NOT ARM. CYCLED ARMING HANDLE, DOOR ARMS NORMALLY. UNABLE TO DUPLICATE PROBLEM. SUSPECT F/A TECHNIQUE PROBLEM.Mar 15, 2007 · N128UA · Boeing 747422 · DoorsSDR 2007UALA00769Power Supply · faultyZONE "E" ALL EMERGENCY LIGHTS TURN ON AND OFF. [SUP 4-17-07] REPLACED POWER SUPPLY M6010, 6011, 6012 AND 6013 PER MM 33-51-04 P201. OPS CHECKED OK.Mar 15, 2007 · N199UA · Boeing 747422 · Emergency LightingSDR 2007UALA00756Lamp · burned outFLIGHT DECK EMERGENCY LIGHT LAMP BURNED OUT. REPLACED WITH NEW FLIGHT DECK EMERG LIGHT LAMP. EMERG LIGHTS CHKED NORMALLY.Mar 14, 2007 · Boeing 747422 · Emergency LightingSDR 2007UALA00755Light · faultySEAT EEL AT SEATS 2J, 4E (AFT) & 5E (AFT) ARE FAULTY. REPLACED EEL AT THREE POSITIONS WITH NEW EMERGENCY LIGHT. EEL SYSTEM OP CHECKED NORMALLY.Mar 14, 2007 · N120UA · Boeing 747422 · Emergency LightingSDR 2007UALA00754Light · inoperativeEXTERIOR EMERGENCY OVERWING EXIT LIGHTS INOPERATIVE ON LEFT SIDE TWO MOST AFT ASSEMBLIES. REPLACED FUSE IN EMERGENCY POWER SUPPLY UNIT, CHECKS OK.Mar 14, 2007 · N118UA · Boeing 747422 · Emergency LightingSDR 2007UALA00753Lamp · inoperativeEMERGENCY EXIT LIGHT INOPERATIVE AT SEAT 42L. REPLACED LAMP ASSY. OP CHECKS NORMALLY.Mar 14, 2007 · N118UA · Boeing 747422 · Emergency LightingSDR 2007UALA00752Lamp · inoperativeEMERGENCY EXIT CEILING LIGHT INOP JUST AFT OF FWD GALLEY RIGHT SIDE. RELAMPED. OP CHECKED NORMALLY.Mar 14, 2007 · N118UA · Boeing 747422 · Emergency LightingSDR 2007UALA00751Connector · looseEMERGENCY EXIT LIGHT INOPERATIVE AT SEAT 2J & AT DOOR 5L GALLEY CROSS-AISLE. SUPPLEMENTAL DATA UPDATE FOUND LOOSE CONNECTION, RESECURED. EEL CHECKS OKMar 14, 2007 · N118UA · Boeing 747422 · Light System WiringSDR 2007UALA00792Wedge · delaminatedHAIL DAMAGE TO T/E WEDGE UPPER SKIN OF T/E DAMAGED. T/E REPAIRED. T/E WEDGE REMOVED FOR REPAIR AND REINSTALLED. UPPER SKIN FWD OF T/E SEAM DAMAGED. SEAM DAMAGE REPAIRED. AIRCRAFT READY FOR SERVICE.Mar 12, 2007 · N104UA · Boeing 747422 · AileronsSDR 2007UALA00727Squib · faultyAFT CARGO FIRE BOTTLE A FWD SQUIB TEST BAD. REPLACED SQUIB AND TESTED PER MMOV 26-23-02 . TESTED OK FOR SERVICE. SUSPECT INTERNAL DETERIORATION OF SQUIB.Mar 10, 2007 · N175UA · Boeing 747422 · Fire Bottle, FixedSDR 2007UALA00729Lamp · inoperativeWALL EEL INOP BETWEEN MID LAVS. REPLACED LAMP, EEL OP CHECKED NORMALLY.Mar 9, 2007 · N195UA · Boeing 747422 · Emergency LightingSDR 2007UALA00728Lamp · inoperativeEMERGENCY LIGHT INOP ROW 35 ABC. REPLACED LAMP. OP CHECKED OK FOR SERVICE.Mar 9, 2007 · N195UA · Boeing 747422 · Emergency LightingSDR 2007UALA00697Lamp · inoperativeEMERGENCY CEILING LIGHTS AT 7R & DOOR 3R ARE INOPERATIVE. RELAMPED, CHECKS OK.Mar 8, 2007 · N179UA · Boeing 747422 · Emergency LightingSDR 2007UALA00696Lamp · inoperativeEEL 40 HJK & 48 ABC ARE INOPERATIVE. RELAMPED, CHECKS NORMAL.Mar 8, 2007 · N179UA · Boeing 747422 · Emergency LightingSDR 2007UALA00716Fuel Sys · malfunctionedUNWANTED FUEL TRANSFER FROM CTR INTO NR 2 MAIN TANK IN FIRST HOUR OF FLIGHT. TANK ENTRY & TROUBLESHOOTING IDENTIFIED FUEL JETTISON PUMP CHECK VALVE NOT FULLY CLOSING. REPLACED VALVE & AIRCRAFT RETURNED TO SERVICE. SUSPECT VALVE WEAR LED TO HANG-UP WHICH PREMar 8, 2007 · N121UA · Boeing 747422 · Aircraft Fuel Distribution SystemSDR 2007UALA00700Actuator · unknownLANDING GEAR WON'T RETRACT; RTFL & LANDED UNDER AMBER ALERT. REPLACED RT BODY TILT ACTUATOR. CYCLED GEAR, OP CHECKED OK.Mar 8, 2007 · N175UA · Boeing 747422 · Landing Gear ActuatorSDR 2007UALA00694Light · inoperativeEEL AT 5E, 5F & DOOR 5L XAISLE ARE INOPERATIVE. SECURED LOOSE FEEDER CABLE IN ONE POSITION AND SPLICED CABLE IN THE OTHER. EEL LIGHTS OP CHECKED OK FOR SERVICE. SUSPECT DAMAGE CAUSED BY PAX TRAFFIC & CARRY-ON BAGGAGE IMPACT.Mar 8, 2007 · N179UA · Boeing 747422 · Emergency LightingSDR 2007UALA00695Connector · unsecureEEL AT 4E & 4F ARE INOPERATIVE. SECURED LOOSE FEEDER CONNECTOR. EEL OP CHECKED OK.Mar 8, 2007 · N179UA · Boeing 747422 · Light System WiringSDR 2007UALA00682Fuse · inoperativeFOUR EACH EXTERIOR OVERWING EMERGENCY EXIT LIGHTS INOP ON LEFT SIDE. REPLACED FUSES IN EPSU. CHECKS OK.Mar 7, 2007 · N104UA · Boeing 747422 · Emergency LightingSDR 2007UALA00681Lamp · burned outEMERGENCY LIGHTS INOP AT EXIT STAIR ILLUMINATION TO UPPER DECK AND AT ROW 59 LEFT. REPLACED LAMPS, CHECKS OK.Mar 7, 2007 · N104UA · Boeing 747422 · Emergency LightingSDR 2007UALA00680Lamp · burned outEMERGENCY EXIT CEILING LIGHT INOP AT TOP OF UPPER DECK STAIRS. RELAMPED, OPS NORMAL.Mar 7, 2007 · N104UA · Boeing 747422 · Emergency LightingSDR 2007UALA00668Feeder Cable · cutEEL LIGHT CABLE CUT AT SEATS 4A & 5E. REPLACED WITH NEW EMER LIGHT SEGMENTS (2 POSITIONS). EEL SYSTEM CHECKED NORMALLY.Mar 6, 2007 · N119UA · Boeing 747422 · Light System WiringSDR 2007UALA00667Structure · crackedCORROSION - INBOARD BORE OF THE DIAGONAL SIDE BRACE UNDER WING FITTING AT NR 1 NACELLE STRUT ATTACH AREA. FOUND CORROSION - INBD BORE OF THE DIAGONAL SIDE BRACE UNDER WING FITTING AT NUMBER 1 NACELLE STRUT ATTACH AREA. ACP BORING THE DSB UNDER WING FITTINMar 6, 2007 · N119UA · Boeing 747422 · Wing Main, Frame StructureSDR 2007UALA00666Structure · corrodedCORROSION - BOTH DIAGONAL SIDE BRACE FITTING BORES AT NR 1 NACELLE. MAJOR REPAIR. CORROSION - BOTH DUAL SIDE BRACE FITTING BORES AT NUMBER 1 NACELLE. ACCOMPLISHED BORING THE DSB NACELLE STRUT AT NR 1. BOTH HOLES IN SPEC PER COA AND SB 747-54A2218 (FINAL HOMar 6, 2007 · N119UA · Boeing 747422 · Nacelle/Pylon, Main FrameSDR 2007UALA00670Flashlight · faultyRED LED FOR HI-INTENSITY EMERGENCY FLASHLIGHT (OUTBOARD) IS NOT FLASHING AT ATTENDANT'S SEAT NEAR NR 3 LEFT MAIN ENTRY DOOR. REMOVED AND REPLACED HI -INTENSITY EMERGENCY FLASHLIGHT (OUTBOARD) AND BATTERY KIT NEAR NR 3 LT MAIN ENTRY DOOR. OPERATIONAL CHECKEDMar 5, 2007 · N198UA · Boeing 747422 · Emergency EquipmentSDR 2007UALA00669Module · intermittentF/A REPORTS UPPER DECK LEFT DOOR SLIDE LIGHT INOP. FOUND DOOR ANNUNCIATOR MODULE WORKING INTERMITTENTLY. NEEDS MODULE M7035. NO PCN ONLY P-N 65B48538-2. SEE IPC 52-23-15-001 ITEM 20. REPLACED MODULE. TESTED & FOUND OK FOR SERVICE.Mar 5, 2007 · N122UA · Boeing 747422 · Escape SlideSDR 2007UALA00665Structure · corrodedCORROSION ON BOTH DIAGONAL SIDE BRACE FITTING BORES AT NUMBER 4 NACELLE STRUT. ACCOMPLISHED BORING THE DUAL SIDE BRACE FITTING ON THE NACELLE STRUT AT NUMBER 4. BOTH HOLES DRESSED OUT PER COA AND SB 747-54A 2218 (FINAL HOLE DIA AFTER HONE=2.2454"). REASSEMMar 5, 2007 · N119UA · Boeing 747422 · Nacelle/Pylon, Main FrameSDR 2007UALA00643Fitting · corrodedCORROSION - BOTH BORES OF THE DSB UNDERWING FITTING AT NUMBER 4 NACELLE STRUT ATTACH AREA. ACCOMPLSHED BORING OF THE DUAL SIDE BRACE UNDERWING FITTING AT NUMBER 4. BOTH HOLES PER BOEING SB 747-54A2218 (FINAL HOLE DIA AFTER HONE = 2.2450). SUSPECT CORROSION Mar 5, 2007 · N119UA · Boeing 747422 · Wing, Attach FittingsSDR 2007UALA00656Connector · faultyRTFL UNDER AMBER ALERT DUE TO HYDRAULIC OVERHEAT MESSAGE. REPLACED TEMPERATURE TRANSMITTER FOR ENG NR 1 HYD SYSTEM PER A MM 29-32-02. NO LEAKS. AFTER REPLACEMENT INDICATION IS BLANK. SUSPECT CONNECTOR. REPLACED CONNECTOR. SYSTEM TEST OK. SUSPECT VIBRATIMar 3, 2007 · N175UA · Boeing 747422 · Hydraulic Power System WiringSDR 2007UALA00626Attach Fitting · damagedFOUND GUIDE MOUNT ATTACHMENT AT TORQUE BOX HAS DAMAGE TO THE PRIMARY STRUCTURE. UPON REMOVAL OF FLOOR BOARD FOR FLOOR MOUNT CENTER GUIDE INSTALLATION, FOUND DAMAGE AREA JUST AFT OF THE CENTER GUIDE MOUNT BOLTS, STA 1800 CENTER LINE BEAM. REMOVED DAMAGED MOUMar 1, 2007 · N122UA · Boeing 747422 · Fuselage Miscellaneous StructureSDR 2007UALA00624Lamp · inoperativeDOOR 3L FWD EMERGENCY SILL LIGHT INOP. RELAMPED. CKS OKAY.Mar 1, 2007 · N120UA · Boeing 747422 · Emergency LightingSDR 2007UALA00623Light · inoperativeDOOR 3L SLIDE ILLUM EMERGENCY LIGHT INOP. REPLACED LT. ASSY. NORMAL.Mar 1, 2007 · N120UA · Boeing 747422 · Emergency LightingSDR 2007UALA00622Lamp · inoperativeEMERGENCY CEILING LIGHT AT ROW 8 RT & ROW 53 LT ARE INOPERATIVE. RELAMPED. CKS OK.Mar 1, 2007 · N120UA · Boeing 747422 · Emergency LightingSDR 2007UALA00621Light · inoperativeEEL(S) AT 1A FWD, 4A FWD, 33ABC, 38 ABC & 49HJK ARE INOPERATIVE. RELAMPED. OKAY.Mar 1, 2007 · N120UA · Boeing 747422 · Emergency LightingSDR 2007UALA00603Light · inoperativeOVERWING LT EMERGENCY LIGHT 2 BOTTOM INOPERATIVE. REPLACED ASSY. CHECKS OK.Feb 27, 2007 · N180UA · Boeing 747422 · Emergency LightingSDR 2007UALA00602Wire Harness · damagedEMERGENCY LIGHT ROW 2J INOPERATIVE. REPLACED EEL SEAT HARNESS AT ROW 2J, OP CHECKS OK.Feb 27, 2007 · N180UA · Boeing 747422 · Light System WiringSDR 2007UALA00601Light · inoperativeOVERWING EMERGENCY 3RD LIGHT WAS OUT AT RT WING TO BODY AFT AREA. REPLACED WITH NEW LAMP & THEN OP CHECKED NORMALLY.Feb 27, 2007 · N119UA · Boeing 747422 · Emergency LightingSDR 2007UALA00600Lamp · inoperativeG5 GALLEY, G1A GALLEY LT, STAIRWAY & SEAT 17AB CEILINGS EMERGENCY LIGHT LAMPS ARE BURNED OUT. REPLACED NEW LAMPS AND CHECKED NORMAL.Feb 27, 2007 · N119UA · Boeing 747422 · Emergency LightingSDR 2007UALA00590Lamp · inoperativeEMERGENCY CEILING LIGHT ABOVE ROW 18 INOPERATIVE. RELAMPED CEILING EEL .OP CHECKED NORMALLY.Feb 26, 2007 · N180UA · Boeing 747422 · Emergency LightingSDR 2007UALA00588Battery Pack · inoperativeUPPER DECK LEFT ESCAPE DOOR BATTERY PACK INOP. SWAPPED BAT PACKS AND FOUND BAT PACK INOP. REPLACED BAD BATTERY PACK. SYSTEM OP CHECKED OK FOR SERVICE.Feb 23, 2007 · N116UA · Boeing 747422 · Emergency LightingSDR 2007UALA00567Slide · unsecureFOUND DOOR 1L EMERGENCY EXIT SLIDE COMING UNPACKED. REPLACED SLIDE. OK FOR SERVICE. SLIDE PROBLEM ROOT CAUSE; SUSPECT INADEQUATE BINDING OF SLIDE CAUSED BY IMPROPER REFURBISHMENT.Feb 21, 2007 · N127UA · Boeing 747422 · Escape SlideSDR 2007UALA00566Connector · brokenFOUND SEAT 3J AFT EEL CABLE CONNECTOR BROKEN, EEL INOPERATIVE. REPLACED WITH NEW CONNECTOR PLUG. OP CHECKED NORMALFeb 21, 2007 · N127UA · Boeing 747422 · Light System WiringSDR 2007UALA00557Lamp · inoperativeFOUND EMERGENCY LIGHT INOPERATIVE AT DOOR 4R AFT SILL. RELAMPED EEL AT DOOR 4R. OP CHECKED GOOD.Feb 21, 2007 · N117UA · Boeing 747422 · Emergency LightingSDR 2007UALA00556Feeder Cable · inoperativeFOUND EEL INOPERATIVE AT DOOR 5L XAISLE. REPLACED FEEDER TO LT CROSS AISLE EEL AT DOOR 5L. OP CHECKED NORMALLY.Feb 21, 2007 · N117UA · Boeing 747422 · Light System Wiring
Back to Boeing 747-422