SDR 2004UALA00749Power Supply · intermittentEVACUATION PATH LIGHTING AT RIGHT SIDE OF D-ZONE COMES ON AND OFF AT INTER. REPLACED BATTERY ABOVE DOOR 3R.SDR 2004UALA00687Circuit Card · malfunctionedTHE NR 4 HYDRAULIC SYSTEM LOSS OF PRESSURE AND FLUID. QUANTITY AND PRESSURE FLUCTUATIONS DUE TO FAULTY HYDIM CARD. CARD REPLACED. AIRCRAFT HAS HAD NO FURTHER HYDRAULIC INDICATION PROBLEMS FOR LAST 8 FLIGHTS.SDR 2004UALA00673Rib · crackedSIGNIFICANT SHUDDER ON CLIMBOUT WITH RIGHT O/B AIL. *S/D* THE NR 2 RIGHT OUTBOARD AILERON HINGE FITTING WAS FOUND CRACKED DUE TO FATIGUE. THE CRACKED FITTING WAS REPLACED.SDR 2004UALA00650Light · damagedEXIT PATH LIGHT DAMAGED. REPLACED EEL.SDR 2004UALA00659Bottle · mispinnedDURING SLIDE OVERHAUL SAFETY PIN FOR BOTTLE FOUND INSTALLED IN REGULATOR. *S/D* PIN INCORRECTLY LEFT IN BOTTLE DURING PREVIOUS SLIDE OVERHAUL. AS SHOP AND PERSONNEL THAT OVERHAULED THIS SLIDE ARE NO LONGER BEING USED, NO CORRECTIVE ACTION NECESSARY. BOTTLESDR 2004UALA00629Drive Unit · inoperativeFLIGHT RETURNED TO NARITA DUE TO FLAP PROBLEM.CREW HAD EICAS MESSAGE FLAPS PRIMARY, AND RT MIDSPAN INDICATION WENT TO RED, EACH SPEED INCREASE. THE CREW SENSED NO CONTROL PROBLEMS. NRTMM REPLACED THE NR 3 RT LE SLAT DRIVE UNIT. NO FURTHER HITS HAVE BEEN REPORTSDR 2004UALA00619Landing Gear · malfunctionedAFTER T/O GEAR DOOR OPEN LIGHT INDICATION. CREW FELT VIBRATION FROM OPEN DOORS. PROBABLE CAUSE IS A DOOR OUT OF SEQUENCE CONDITION DUE TO ALTERNATE EXTEND MOTOR NOT RESETTING. THIS IS KNOWN CONDITION AND IS SOMETIMES CAUSED BY DEPRESSING ALTERNATE EXTEND SWSDR 2004UALA00592Compressor · bird ingestionABORTED TAKEOFF AT 108 KTS DUE TO NR 2 ENG COMP STALL AT 100 KTS. DETERMINED STALL DUE TO A BIRD STRIKE.SDR 2004UALA00608Bolt · misinstalledDOOR 4 RIGHT SLIDE, AT OVERHAUL A BOLT WAS FOUND INSERTED IN THE SAFETY PIN LOCATION OF THE VALVE. THE FIRING LANYARD WAS WRAPPED AROUND A INFLATION HOSE. THE SURVIVAL KIT ATTACHMENT CORD WAS LOCATED ON THE SIDE RATE COVER INSTEAD OF THE GIRT AREA. ONE OF THESDR 2004UALA00512Skin · damagedFUSELAGE DAMAGE AT STA 670-700 STR 46L-44R & STA 710-740 STR 42R-45R. MAJOR REPAIRS ACCOMPLISHED. INSTALLED JOINT REPAIRS, STRINGER REPAIRS AND THREE DOUBLER REPAIRS.SDR 2004UALA00477Lamp · intermittentEMERGENCY EXIT LIGHTS 15-16B, COME ON-OFF FOR NO REASON. RELAMPED AND SECURED BATTERY PACK. NO FLICKERING AT 15-16B AREA. EMERGENCY EXIT LIGHTS TEST OK.SDR 2004UALA00539Slide · deployedFORWARD BOTTLE DISCHARGED WHEN PINS WERE PULLED RESULTING IN SLIDE DEPLOYMENT. UNABLE TO DEFINITIVELY DETERMINE CAUSE OF FAILURE DUE TO PARTIAL DEPLOYMENT OF SLIDE. SUSPECT THAT INFLATION CABLE WAS MISROUTED, RESULTING IN TENSION WHICH DEPLOYED SLIDE WHEN BOSDR 2004UALA00459Floorbeam · bentFWD PIT STA 760 RBL 49 AFT FLANGE OF UPPER TEE CHORD IS BENT. MAJOR REPAIR ACCOMPLISHED. FABRICATED AND INSTALLED REPAIR ANGLES AND T-EXTRUSION.SDR 2004UALA00458Frame · dentedAFT PIT FRAME AT STA 1840 LBL 61 HAS DENT AT LOWER SECTION. MAJOR REPAIR ACCOMPLISHED. FABRICATED AND INSTALLED NEW FRAME.SDR 2004UALA00457Floorbeam · bentFWD PIT STA 840 RBL 49 FLANGE OF UPPER TEE CHORD IS BENT RBL 8 TO RBL 65. MAJOR REPAIR ACCOMPLISHED. FABRICATED AND INSTALLED REPAIR ANGLES & T-EXTRUSION.SDR 2004UALA00456Floor Support · corrodedAFT PIT STA 1920 T-CAP CORRODED FROM RBL 58 TO LBL 58. MAJOR REPAIR ACCOMPLISHED. FABRICATED AND INSTALLED NEW T-CAP SECTION.SDR 2004UALA00455Torque Box · dentedFWD PIT TORQUE BOX AT STA 660-680 LBL 25 TO LBL 40 WEB HAS 3 EA DENTS AROUND EXISTING DOUBLER. MAJOR REPAIR ACCOMPLISHED. FABRICATED & INSTALLED NEW WEB.SDR 2004UALA00454Torque Box · crackedAFT PIT TORQUE BOX WEB BETWEEN STA 1840 - 1860 LBL 61 HAS 1 CRACK AND DENT. MAJOR REPAIR ACCOMPLISHED. FABRICATED AND INSTALLED NEW TORQUE BOX WEB.SDR 2004UALA00453Frame · crackedAFT PIT FRAME WEB AT STA 2120 RBL 41.33 CRACKED. MAJOR REPAIR ACCOMPLISHED. FABRICATED AND INSTALLED NEW WEB SECTION.SDR 2004UALA00439Warning Light · illuminatedTOP OF DESCENT CREW GOT AFT CARGO FIRE INDICATOR LIGHT. DECLARED EMERGENCY. USED ONE FIRE BOTTLE AND LIGHT DID NOT EXTINGUISH. NORMAL LANDING. PROBABLE CAUSE A COMBINATION OF AN INTERMITTENT SMOKE DETECTOR AND MOISTURE FROM THE CARGO. SMOKE DETECTOR WAS RESDR 2004UALA00410Floorbeam · crackedAFT PIT RT SIDE STA 2120 T-CAP FOR WASTE TANK SUPPORT FITTING CRACKED RBL 41 - 33. MAJOR REPAIR ACCOMPLISHED. FABRICATED & INSTALLED NEW T-CAP SECTION.SDR 2004UALA00398Stringer · crackedLWR NOSE COMPT LT CRAWL WAY STRINGER 39 BTWN BS 280 AND BS 300 IS DEFORMED AND CRACKED. MAJOR REPAIR ACCOMPLISHED. REPLACED STRINGER.SDR 2004UALA00394Structure · dentedFWD CARGO DOOR FWD EDGE 36 INCHES FROM TOP DENTED. FABRICATED & INSTALLED FILLER & DOUBLER REPAIR.SDR 2004UALA00393Door Frame · crackedDOOR 1L MED FRAME CRACKED AROUND CENTER BOX. FABRICATED & INSTALLED REPAIR DOUBLER.SDR 2004UALA00376Skin · dentedLWR EXTERNAL FUSELAGE SKIN DENTED BS 1814 LBL 12.5. FABRICATED & INSTALLED DOUBLER REPAIR.SDR 2004UALA00375Skin · dentedEXTERNAL FUSELAGE SKIN HAS DENT AT BS 2188 BTWN S29R & S30R. FABRICATED AND INSTALLED DOUBLER REPAIR.SDR 2004UALA00374Skin · buckledMED 5L EXTERIOR SKIN AT FWD LOWER CORNER BUCKLED. FABRICATED & INSTALLED DOUBLER REPAIR.SDR 2004UALA00373Frame · dentedAFT PIT FLOOR FRAME T-CAP DENTED AT FRAME 1600 LBL 13. MAJOR REPAIR ACCOMPLISHED. FABRICATED & INSTALLED NEW T-CAP.SDR 2004UALA00388Odor · detectedFA REPORTED SMELLING PLASTIC BURNING SMELL/SMOKE. F/A USED A PLASTIC COVER WHILE HEATING FOOD. PLASTIC COVERED FOOD IS NOT LOADED INTO OVENS. F/A SHOULD REVIEW CORRECT PROCEDURES FOR RECON OVENS AND NEVER PLACE ANY PLASTIC ITEMS INTO OVENS.SDR 2004UALA00332Slide · tornSLIDE FAILED PROOF PRESSURE TEST AFTER 3 MINUTES AT 4.2 PSI. THE SEAM BELOW THE GIRT TORE. SLIDE WAS RETURNED TO OEM FOR ANALYSIS, BUT SPECIFIC CAUSE FOR FAILURE WAS INDETERMINATE. INFLATABLE PORTION OF SLIDE WAS SCRAPPED.SDR 2004UALA00323Floorbeam · crackedFWD PIT STA 760 RBL 56 FLOORBEAM CRACKED AND DENTED. MAJOR REPAIR ACCOMPLISHED. REMOVED DAMAGE. FABRICATED AND REPLACED SECTION.SDR 2004UALA00307Warning Light · illuminatedON FINAL APPROACH FIRE CARGO AFT CAME ON. CREW USED ONE EXTINGUISHER BOTTLE. EMERGENCY EQUIPMENT STANDING BY. IN ADDITION TO THE "FIRE CARGO AFT" WARNING DURING DECENT, FLIGHT CREW OBSERVED STATUS MESSAGE "AFT CARGO 4 LP B". NRTMM FOUND STORED CMC FAIL MESSSDR 2004UALA00288Skin · dentedBULK CARGO COMPARTMENT SKIN DENTED FROM STRINGER 47L TO 46L AT STA 1936. MAJOR REPAIR ACCOMPLISHED. FABRICATED & INSTALLED DOUBLER & SPLICE REPAIR.SDR 2004UALA00284Light · intermittentEMERGENCY LIGHTS FLASHING IN ALL ZONES. COULD NOT DUPLICATE. LIGHTS CHECKED GOOD.SDR 2004UALA00253Battery Pack · inoperativeEMERGENCY EXIT LIGHTS AT DOOR 4R INOP AT TWO LOCATIONS. REPLACE BATTERY PACK BASE AND PACK.SDR 2004UALA00235Power Supply · inoperativeEMERGENCY LIGHTS AT SEATS 32, 33, 34 A, B & C COME ON AND OFF INTERMITTENTLY WHILE AT THE GATE. REPLACED POWER SUPPLY UNIT ABOVE 3L.SDR 2004UALA00212Light · inoperativeSLIDE LIGHT INOP AT DOOR 3L. REPLACED & TESTED DOOR SLIDE LIGHT LAMP, TESTS GOOD.SDR 2004UALA00201Skin · lightning strikeLIGHTNING STRIKE BLENDED OUT OF LIMIT AT STA 190 AND STRINGER 28AL (LEFT). MAJOR REPAIR ACCOMPLISHED. FABRICATED & INSTALLED EXTERNAL SKIN DOUBLER.SDR 2004UALA00286Slide · failedDOOR 2 RIGHT SLIDE FAILED OVER PRESSURE TEST AT 3.80 PSI DURING OVERHAUL. SLIDE OEM ANALYSIS OF FAILURE WAS INCONCLUSIVE. INFLATABLE PORTION OF SLIDE SCRAPPED.SDR 2004UALA00168Skin · damagedAFT CARGO DOOR LOWER SKIN DAMAGED AT EDGE. MAJOR REPAIR ACCOMPLISHED. FABRICATED & INSTALLED FILLER AND DOUBLER.SDR 2004UALA00146Odor · detectedRIGHT ELEC UTIL EICAS MSG WITH ELECTRICAL ODOR IN GALLEY. AFTER SHUTTING DOWN RIGHT UTIL BUS, LEFT BUS TRIPPED. W/U STATES ELECTRIC BURNING ODOR FOLLOWED BY "ELEC UTILITY BUS R" AND THEN BY "ELEC UTILITY BUS L" BOTH UTILITY BUS SW'S SELECTED "OFF" PER FLT MASDR 2004UALA00145Fuse · blownRIGHT OVERWING AFT 2 EMERGENCY LIGHTS INOPERATIVE. REPLACED FUSE IN POWER SUPPLY. CHECKS OK.SDR 2004UALA00123Floorbeam · corrodedCORROSION WAS DISCOVERED ON THE UNDERSIDE OF THE FLOORBEAM LOCATED AT STA 1100 FROM LBL 17 TO LBL 30. MAJOR REPAIR ACCOMPLISHED. FABRICATED AND INSTALLED REPAIR STRAP.SDR 2004UALA00110Line · chafedFLT HAS HAD NR 1 QTY INDICATION LOSS WITH PSBL HYD PRESS LOSS. AMBER ALERT DECLARED. LOSS OF FLUID DUE TO LANDING GEAR DOWN HYDRAULIC LINE PIN HOLE LEAK. PIN HOLE CAUSED BY CHAFING DUE TO BROKEN CLAMP BACC10CC-8 LOCATED AT STA 900. ACCOMPLISHED RYNGLOK RESDR 2004UALA00091Terminal Block · missingEMERGENCY LIGHT ON DOOR NR 2 LEFT, STAYS ON ALL THE TIME. FOUND GROUND MISSING AT TERMINAL BLOCK. SECURED GROUND TERMINAL. LIGHT ASSY OPS CHECKS OK FOR ALL FUNCTIONS.SDR 2004UALA00044Door · unsecureAFTER TAKEOFF UNABLE TO PRESSURIZE A/C. EICAS CAUTION DOOR AFT CARGO ILLUMINATED. FOUND LATCH CAM MANUAL LOCK HITTING CAM ON AFT CARGO DOOR. RERIGGED LATCH CAM TO ALLOW FOR 0.06 INCH CLEARANCE.SDR 2005UALA00058Door Frame · dentedEXTERNAL POWER RECEPTACLE PANEL DOOR FRAME IS DENTED. FABRICATED & INSTALLED INTERNAL DOUBLER PER EA. INSTALLED SHIMS & FILLERS AS REQUIREDSDR 2004UALA00027Battery · malfunctionedUPPER DECK RIGHT DOOR SLIDE BATTERY LIGHT PRESS TO TEST FUNCTION INOP. CHANGED BATTERIES.SDR 2004UALA00023Battery Pack · inoperativeEMERGENCY EXIT LIGHTING ON AT SEATS 22-26 GHJ ZONE B. REMOVED, CHARGED & REINSTALLED BATTERY PACK, OP CHECKS OK.SDR 2004UALA00004Battery · inoperativeEMERGENCY EXIT LIGHTS FLOOR LIGHT DAMAGED AT ZONE-E AREA OF SEATS 57C - 58C. REPLACED EEL BATTERY IN FRONT OF 5L.
Back to Boeing 747-422