Boeing 747-422
Service difficulty reports · 9,801
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '747422' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '747422' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 2002UALA00020Element · looseEMERGENCY LIGHT STRIP AFT ELEMENT IS OUT AT SEAT 5A AND F. FWD ELEMENT IS LOOSE, REPAIRED.SDR 2002UALA00022Fuse · blownBOTH FORWARD EXTERIOR OVERWING EMERGENCY LIGHT ASSEMBLY'S INOP ON LEFT HAND SIDE. REPLACED FUSE IN POWER SUPPLY.SDR 2002UALA00019Light · inoperativeEEL LIGHT INOP AT AFT GALLEY LEFT HAND NEXT TO LAV 117. REPLACED EEL STRIP NEXT TO LAV 117.SDR 2001UALA02478Skin · crackedTHE TAIL CONE LOWER SKIN HAS CRACK AND DENT JUST AFT OF THE APU COMPARTMENT. MAJOR REPAIR ACCOMPLISHED INSTALLED REPAIR DOUBLER.SDR 2001UALA02429Battery Pack · dischargedEMERGENCY LIGHTS FROM ROW 55 TO DOOR 5 RIGHT WILL NOT TURN OFF. REPLACED DOOR 4 RT AND 5 RT EMERGENCY LIGHT BATTERY PACKS.SDR 2001UALA02427Stringer · damagedRIGHT HAND FUSELAGE STATION 760-1780 STRINGER 36 HAS REPAIR DOUBLER INSTALLED WITH INSUFFICIENT CIRCUMFERENTIAL FASTENER ROWS. MAJOR REPAIR ACCOMPLISHED. REPLACED DOUBLER.SDR 2001UALA02404Floorbeam · damagedSTATION 1700 FLOORBEAM UPPER CHORD HAS EXCESSIVE MATERIAL AT RBL 44. ANGLES AND STIFFENERS ANGLES INSTALLED.SDR 2001UALA02357Skin · puncturedTHE RIGHT HAND EXTERIOR SKIN WAS PUNCTURED JUST AFT OF DOOR 5R. BODY STATION 2290, NEAR STRINGER 21R. MAJOR REPAIR ACCOMPLISHED, A DOUBLER REPAIR WAS INSTALLED.SDR 2001UALA02299Light · inoperativeROW 34C EMERGENCY CEILING LIGHT IS INOP. RELAMPED, OPS CHECKED EMERGENCY CEILING LIGHT OK.SDR 2001UALA02285Light · inoperativeEMERGENCY CEILING LIGHT INOP AT ROW 12. RELAMPED, CHECKED GOOD.SDR 2001UALA02274Connector · looseEEL OPPOSITE LAV 102 INOP. FOUND CONNECTOR LOOSE. SECURED EEL CONNECTOR.SDR 2001UALA02286Fuse · blownEMERGENCY LIGHTS AFT LEFT LOWER TWO INOP. REPLACED FUSE ON POWER SUPPLY M7919 AND LIGHT ASSEMBLY AT STATION 1586. OPS CHECK GOOD.SDR 2001UALA02275Connector · looseEEL LIGHTS INOP SEATS 6G THROUGH 8G. SECURED CONNECTOR AT AFT GALLEY SIDEWALL STRIP, OPS CHECKS OK.SDR 2001UALA02235Light · inoperativeINOP EMERGENCY LIGHTS UPPER DECK CEILING ABOVE SEATS 16, 17 AND AFT OF SEATS 18 BETWEEN STAIRWELL AND CLOSET. RELAMPED, CHECK OK.SDR 2001UALA02234Light · inoperativeSECOND TO LAST FORWARD EMERGENCY WING LIGHT INOP RIGHT. RELAMPED, OPS CHECKS GOOD.SDR 2001UALA02233Light · inoperativeAFT EEL LIGHT INOP AT SEATS 2J, 1A AND 3A. REPLACED LAMPS AND CHECKED GOOD.SDR 2001UALA02192Fuse · blownEMERGENCY LIGHT ASSEMBLIES 1 AND 2 INOP RIGHT WING FILLET PANEL. REPLACED BATTERY PACK FUSE. OPS CHECKS OK.SDR 2001UALA02185Wire · disconnectedEMERGENCY EEL LIGHT JUST FORWARD OF AFT LAV 17. FOUND FEEDER CABLE NOT HOOKED UP TO POWER CABLE. CONNECTED AND REPLACED CABLE CONNECTED TO EEL LIGHT ASSY, OPS CHECK OK.SDR 2001UALA02179Door Frame · crackedNR 2 RIGHT HAND MED UPPER DOOR FRAME AT GATE HAS CRACK ATTACH HOLE. DOOR SHOP ACCOMPLISHED REPAIR.SDR 2001UALA02172Battery Pack · dischargedEMERGENCY LIGHT INOP, DOOR 4 RIGHT, AFT EXIT SIGN. REPLACED BATTERY PACK. CHECKED OK.SDR 2001UALA02157Wire · exposedFLIGHT ATTENDANT REPORTED BRIEF FIRE IN AFT GALLEY FROM CART N54 PIGTAIL HAS EXPOSED WIRE. THE 9F21904-501 PIGTAIL CABLE IN THE G5 GALLEY WAS DAMAGE DUE TO THE CABLE BEING PINCHED BETWEEN THE NEW TECH CART AND GALLEY COUNTER TOP. THE CABLE WAS REPLACED WITH SDR 2001UALA02132Frame · puncturedFORWARD PIT FRAME WEB AT STATION 620 RBL 40 PUNCTURED. MAJOR REPAIR ACCOMPLISHED TO FORWARD PIT WEB AT STATION 620 RBL 40.SDR 2001UALA02116Wire · shortedFOUND EEL FIRST CLASS AREA (1A-5A) AND (4E-5E) INOP. ALL EELS CHECKS GOOD. FOUND SHORT AT SEAT 1A EEL LIGHT ASSY WIRING. REPAIRED AND REPLACED LIGHT ASSY.SDR 2001UALA02099Light · inoperativeEMERGENCY CEILING LIGHT AT SEAT 16 INOP. RELAMPED, CHECKED OK.SDR 2001UALA02100Floorbeam · corrodedBS 520 FLOORBEAM UPPER CHORD EXCESSIVELY CORRODED. BLENDED BEYOND LIMITS.SDR 2001UALA02058Connector · looseSTATUS MESSAGE ON TAKEOFF, FLAPS CONF WITH FLAPS IN POSITION 10 DEGREES. ABORTED TAKEOFF AT 100 KTS. FOUND LEFT OUTBOARD TRAILING EDGE FLAP DRIVE CANNON PLUG NOT SECURED. SECURED CONNECTOR MESSAGE CLEARED. FLAPS OPS NORMAL NOW.SDR 2001UALA02037Stringer · dentedDENT IN STRINGER 27R 41 INCH FWD OF NR 2 RIGHT HAND MAIN ENTRY DOOR (UNDERNEATH THE FLOOR).SDR 2001UALA01993Connector · looseEEL STRIP LIGHT INOP AT RT CLOSET ON BOTTOM FWD OF LAV 102. LOOSE CONNECTOR BEHIND SEAT. SECURED CONNECTOR.SDR 2001UALA01931Battery Pack · faultyEMERGENCY EXIT PATH LIGHTS CAME ON UNCOMMANDED IN CABIN FROM ROW 55ABC THRU 60BC. FAULTY EEL BATTERY PACK AT DOOR 5L. REPLACED BATTERY PACK.SDR 2001UALA01930Floorbeam · corrodedUPPER DECK FLOORBEAM STATION 1060 RBL 46 CORRODED. MAJOR REPAIR ACCOMPLISHED, TO FLOORBEAM STATION 1060 RBL 46.SDR 2001UALA01932Light · inoperativeEMERGENCY LIGHT INOP 48C CEILING. EMERGENCY CEILING LIGHT BURNED OUT. RELAMPED LIGHT.SDR 2001UALA01957Warning System · activatedDURING APPROACH, UPON GEAR EXTENSION, THE CREW GOT A GEAR DISAGREE INDICATION. A MISSED APPROACH WAS EXECUTED. ACFT TURNED FOR NORMAL LANDING.SDR 2001UALA01933Light · inoperativeEEL AISLE LIGHT INOP 1ST CLASS CROSS AISLE. EEL LIGHT BURNED OUT. REPLACED EEL LIGHT.SDR 2001UALA01881Light · inoperativeUPPER DECK EMERGENCY CEILING LIGHTS ROW 12, 14, 16, 18 AND JUST AFT OF ROW 19 ARE INOP. LAMPS BURNED OUT (5 PLACES). REPLACED ALL 5 BULBS.SDR 2001UALA01882Connector · looseSEAT MOUNTED EEL LIGHTS 4E & F AFT ELEMENTS INOP. SEAT MOUNTED EEL LIGHT CONNECTION LOOSE. SECURED CONNECTION.SDR 2001UALA01838Light · inoperativeEMERGENCY LIGHT INOP, CEILING 51G SUPPLEMENTAL DATA UPDATE CEILING EMERGENCY LIGHT INOP. REPLACED BULB.SDR 2001UALA01756Light · inoperativeEMERGENCY LIGHTS INOP, OUTSIDE LEFT UPPER TWO ASSEMBLIES.SDR 2001UALA01694Insulation · contaminatedBURNING GARBAGE SMELL DURING DESCENT. ALL ELECTRICAL POWER LOST TO FIRST CLASS SEATS. SUPPLEMENTAL DATA UPDATE LAXMM FOUND NO ELECTRICAL SMELL, OPS CHECKED VIDEO SYSTEM FOR 6 HRS. POWERED ALL SEATS ALL DAY, ALL SEATS OPERATE NORMAL. CHECKED ALL SYSTEM C-B'S, CSDR 2001UALA01673Fan · failedELECTRIC BURN ODOR IN CABIN FOLLOWED BY STATUS MSG "RECIRCULATING FAN UPPER L". TURNED OFF UPPER RECIRCULATING FANS AND ODOR DISSIPATED. PRESENT LEC FAULT MSG "FAIL-L WIRING FAIL". THE LEFT OVERHEAD RECIRCULATION FAN EXPERIENCED A BEARING FAILURE. FAN WAS REPSDR 2001UALA01696Compressor · surgesNR 3 ENGINE STALLED ON TAKE OFF, FLAMES REPORTED OUT TAILPIPE, EGT OVER TEMPTED OVER 820 DEGREES FOR 15 SECONDS, PEAK EGT 848 DEGREES. CREW WRITE-UP, ENGINE FIRE WARNING NR 3 ENGINE ON TAKE OFF. ENGINE FIRE-DAMAGE CHECKLIST ACCOMPLISHED. TOWER OBSERVED SLIGHT SDR 2001UALA01722Skin · puncturedFUSE SKIN WAS PUNCTURED AND GOUGED AT STA 460 STRINGER 46L. MAJOR REPAIR ACCOMPLISHED. FUSELAGE SKIN DOUBLER REPAIR INSTALLED PER BOEING STRUCTURAL REPAIR MANUAL.SDR 2001UALA01695Light · inoperativeEMERGENCY EXIT OVERHEAD LIGHT ASSEMBLY AT SEATS 17GH INOP. LIGHT ASSEMBLY INOP. REPLACED LIGHT ASSEMBLY.SDR 2001UALA01664Light · inoperativeEMERGENCY CEILING LIGHT INOP AT 3 LEFT MAIN ENTRY DOOR. RELAMPED, OP CHECKED GOOD.SDR 2001UALA01665Power Supply · dischargedEMERGENCY LIGHTS INOP, 55H THROUGH 61H EELS. REPLACED POWER SUPPLY, OPS CHECK OK.SDR 2001UALA01640Connector · looseEMERGENCY LIGHT INOP, AFT GALLEY RIGHT WALL. FOUND LOOSE CONNECTION AT SEAT TRACK. REPLACED AISLE EEL STRIP, CARPET SECURED, EEL CKS GOOD.SDR 2001UALA01641Slide · deployedMAIN ENTRY DOOR NR 4 RIGHT SLIDE IRREGULAR DEPLOYED DOOR CYLINDER DISCHARGED. DOOR NOT FULLY DISARMED PRIOR OPENING. REPLACED SLIDE.SDR 2001UALA01610Light · inoperativeEMERGENCY CEILING LIGHT 58 ABC AISLE INOP.SDR 2001UALA01642Slide · leakingDOOR 1 RIGHT HAND SLIDE RAFT FAILED AIR RETENTION TEST DURING FIRST SHOP OVERHAUL. FOUND HOLE IN RAFT INFLATABLE LOWER TUBE ASPIRATOR TUBE. HOLE APPEARS TO BE CAUSED DURING PACKING. HOLE WILL BE REPAIRED PER VENDOR'S CMM 25-66-19.SDR 2001UALA01618Light · inoperativeEMERGENCY EXIT SIGN AT ROW 22B HAS SOME LAMPS INOP.SDR 2001UALA01643Seat Track · crackedSTA 1840 TO 1856 24" RBL SEAT TRACK OTBD FLANG CRACK. SUPPLEMENTAL DATA UPDATE MRR ENTERED IN ERROR SEAT TRACKS ARE NOT PSE'S.
Back to Boeing 747-422