Boeing 747-422
Service difficulty reports · 9,801
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '747422' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '747422' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2011120906772Windshield · damagedCAPTAIN'S WINDSHIELD HAS AN AREA OF MILKY APPEARANCE APPROX 6" X 4" IN THE CENTER OF THE WINDSHIELD. PER AMM REPLACED PILOT NR 1 WINDSHIELD. PART BORROWED FROM AIR CHINA. PCN180 -6452, PN:60B10028-5 PERFORMED WINDSHIELD HEATER SYSTEM CHECKED PER AMM AND WINSDR UALA2011120906763Battery Pack · dischargedEMERGENCY LIGHT AT FWD GALLEY RT SIDE INOP. REPLACED BATTERY PACK, OP CHECK OKAY.SDR UALA2011120906762Unknown · leakingNR 1 ENGINE SAIL TAIL LEAKING HYDRAULIC FLUID. DUE TO CONTINUED ISSUES WITH NR 1 PYLON AREA SHOWING HYD LEAKS WITH NO POSITIVE FINDINGS ACCP THE FOLLOWING. OBSERVE PYLON AREA HYD FOR LEAKAGE. AT COMPLETION OF CHECKS, SECURE SAIL TAIL DOORS CLOSED DURING ENGSDR UALA2011120906761Battery Pack · dischargedEMERGENCY LIGHT ROW 33 THROUGH 43 LT INOP. REPLACED BATTERY PACK, OPS CHECK OKAY.SDR UALA2011120906760Light · inoperativeEMERGENCY LIGHT ROW 35 RT INOP. RELAMPED, OP CHECK NORMAL.SDR UALA2011120906759Light · inoperativeEMERGENCY CEILING LIGHT ROW 54 LT INOP. RELAMPED, OP CHECK NORMAL.SDR UALA2011120906758Connector · unsecureEMERGENCY LIGHT SIDE WALL OF MAIN GALLEY ALONG DOOR 4L INOP. RE-SECURED EMERGENCY CONNECTOR. OP CHECK NORMAL.SDR UALA2011120906757Battery Pack · dischargedEMERGENCY EXIT LIGHT AT DOOR 1RT INOP. REPLACED BATTERY PACK, OP CHECK OK.SDR UALA2011120806739Connector · unsecureEMERGENCY LIGHTS, 21C TO 25C, INTERMITTENT ON AND OFF UNCOMMANDED. SECURED CONNECTOR ON POWER SUPPLY ABOVE DOOR 3L, CHECKED OK.SDR UALA2011120906766Ballast · failedTHE 17JK CEILING LIGHT INOP. RELAMPED, NO HELP. REPLACED BALLAST (585-4794) AND OP CHECKED GOOD.SDR UALA2011120606713Cable · saturatedEMERGENCY EXIT EEL LIGHTS INOP SEAT ROWS 45 THRU 53 LEFT, DOOR 4 LEFT FWD EXIT SIGN, DOOR 4 RIGHT AFT EXIT SIGN, LOWER WALL EEL ACROSS DOOR 4 LEFT, AND DOOR 4 GALLEY AREA LOWER WALL EEL. THIS IS A REPETITIVE PROBLEM IN THIS SPECIFIC AREA ON 84XX AIRCRAFT. REMSDR UALA2011120606712Light · inoperativeEMERGENCY EXIT LIGHT INOP CEILING ROW 6 RIGHT. RELAMPED EMERGENCY LIGHT.SDR UALA2011120606708Light · inoperativeEMERGENCY EXIT LIGHT INOP DOOR 3 LEFT SLIDE LIGHT. RELAMPED, OPS CHECKS NORMAL.SDR UALA2011120806754Densitometer · failedFAULT MESSAGE 28030 FUEL TANK MAIN 1 DENSITOMETER FAIL.SDR UALA2011120506660Light · inoperativeEMERGENCY LIGHT ALONG AISLE BETWEEN DOOR 2L DOOR 2R INOP. RELAMPED AISLE FLOOR LAMP BETWEEN DOOR 2L AND 2R, OPS CHECK OKAY.SDR UALA2011120506659Light · inoperativeEMERGENCY CEILING LIGHT ROW 9AB INOP. RELAMPED CEILING LIGHT, OPS CHECK OKAY.SDR UALA2011120506658Light · inoperativeEMERGENCY CEILING LIGHT ABOVE ROW 14 INOP. RELAMPED CEILING LIGHT, OPS CHECK OKAY.SDR UALA2011120506667Container · tornTHE 20E LIFE VEST POUCH TORN. REPLACED LIFE VEST.SDR UALA2011120506649Battery Pack · inoperativeSEAT ROW 19-22 HJK EMERGENCY LIGHTS INOPERATIVE. REPLACED BATTERY PACK, OP CHECKED OK.SDR UALA2011120506648Wire · looseSEAT ROWS 45-53 ABC EMERGENCY LIGHTS IS INOPERATIVE. RECONNECTED LOOSE WIRES, OP CHECKED OK.SDR UALA2011120506647Wire · disconnectedSEAT 38ABC EMERGENCY LIGHT IS INOPERATIVE. RECONNECTED LOOSE WIRE, OP CHECKED OK.SDR UALA2011120506666Wire · brokenEEL LIGHT AT DOOR 4L GALLEY CROSS AISLE BROKEN STRIP WITH A BROKEN WIRE. REPLACED EEL LIGHT ASSY 560-4674. OPS CHECKS OKAY PER MM.SDR UALA2011120506642Monitor · overheatedSEAT 2A VIDEO INOP AND APPEARS TO HAVE OVERHEATED, VISIBLE SMOKE FROM MONITOR. CREW SELECTED SEAT POWER OFF AND SMOKE CLEARED. SAMC TEXT: NEED MAINT TO ACP INSPECTION OF SEAT 2A ELECTRICAL COMPONENTS. ISOLATE SOURCE OF SMOKE, ENSURE ADDITIONAL DAMAGE HAS NOSDR UALA2011120506640Apu · odorOIL ODOR FROM APU. REMOVED AND REPLACED APU IAW 49-11-01.SDR UALA2011120206630Window · crackedR1 WINDOW SHOWS SIGNS OF WATER INGRESS AND INTERNAL LAYER CRACKING. REMOVED WINDOW. COMPLETED INSTALLATION IAW MM 56-11-01 STEP 3.I P415.SDR UALA2011120206617Unknown · odorACRID ODOR REPORTED IN 1ST CLASS. 3 FLT ATTENDANTS COMPLAINED OF HYPOXIC SYMPTOMS. NO COMPLAINTS FROM PAX. CREW TURNED OFF RECIRCULATION FANS. CONSULTED FIM 2100 TASK 8-10, ENGINES, APU, PACK BAYS CHECKED, NO OIL LEAKS FOUND. CARGO BAY AND GALLEY EQUIPMENTSDR UALA2011120106612Charger · failedBATTERY CHARGER APU STATUS MESSAGE. REPLACED CHARGER AND BATTERY AS A PRECAUTION. ACCOMPLISHED FIM 24-34 TASK 803 BATTERY STILL AT 25VDC. REPLACED APU BATTERY PER MM. REPLACED APU BATTERY CHARGER PER MM. APU BATTERY CHARGER CHECKED OK. 28 VDC CONFIRMEDSDR UALA2011120106607Terminal · arcedL1 WINDOW HEAT ARCING, FOUND TERMINAL AT WINDOW 1L POS A BURNED AND MELTED INSULATOR BLOCK, REPLACED CONTACT. REMOVED WINDOW 1L.SDR UALA2011120106606Lamp · inoperativeSEAT 16B EMERGENCY LIGHT INOPERATIVE. REPLACED LAMPS, OPS NORMAL.SDR UALA2011120106605Lamp · inoperativeSEAT 15B EMERGENCY LIGHT INOPERATIVE. REPLACED LAMP. OPS NORMAL.SDR UALA2011120106604Lamp · inoperativeSEAT 14B EMERGENCY LIGHT INOPERATIVE. REPLACED LAMP, OPS NORMAL.SDR UALA2011120106603Lamp · inoperativeSEAT 13B FLOOR EMERGENCY LIGHT INOPERATIVE. RELAMPED, CHECKED OKAY.SDR UALA2011120106602Connector · looseSEAT 51ABC EMERGENCY LIGHT INOPERATIVE. FOUND LOOSE CONNECTOR AT LIGHT. RECONNECTED, TESTED OKAY.SDR UALA2011120106600Light · inoperativeAISLE EMERGENCY LIGHT AT L2 DOOR FLOOR CLOSET INOPERATIVE. RELAMPED, OPS CHECKED OK.SDR UALA2011120106599Light · inoperativeR5 DOOR UPPER SILL EMERGENCY LIGHT INOPERATIVE. RELAMPED LIGHT, OPS CHECKED OK.SDR UALA2011120106598Lamp · inoperativeL5 DOOR SILL EMERGENCY LIGHTS INOPERATIVE. RELAMPED LIGHTS, OPS CHECKED OKAY.SDR UALA2011120106597Light · inoperativeLEFT EMERGENCY CEILING LIGHT SEAT 60 INOPERATIVE. RELAMP CEILING LIGHT, OPS CHECKED OKAY.SDR UALA2011120106596Lamp · inoperativeLEFT EMERGENCY CEILING LIGHT AT SEAT 50 IS INOPERATIVE. RELAMPED CEILING LIGHT, OPS CHECKED OKAY.SDR UALA2011120106595Connector · unsecureSEAT 41ABC EMERGENCY LIGHT INOPERATIVE. SECURED CONNECTOR SEAT 41 ABC EMERGENCY LIGHT, OP CHECKED OKAY.SDR UALA2011120106594Lamp · inoperativeSEAT 19ABC EMERGENCY LIGHT INOPERATIVE. RELAMPED, OPS CHECKED OKAY.SDR UALA2011120106590Outflow Valve · malfunctionedDURING TEST FLIGHT, BOTH PRESSURE RELIEF VALVES DID NOT OPEN AT 9.5 PSID. REPLACED BOTH PRESSURE RELIEF VALVES, OP CHECKED OK ON GROUND REF AMM.SDR UALA2011120106608Torque Box · damagedDAMAGE FOUND ON TORQUE BOX AT AFT CARGO BS 800 RT SIDE. DAMAGE IS HOLE 2 INCH X 2 INCH DIA. REPAIRED OVER PATCH TYPICAL WEB REPAIR (PER SRM REPAIR 1).SDR UALA2011113006586Charger · inoperativeEMERGENCY LIGHT OVERWING RT 2 TOP LIGHT INOPERATIVE. REPLACED BATTERY CHARGER AND BATTERY, OP CHECKED NORMAL.SDR UALA2011113006585Lamp · inoperativeEMERGENCY LIGHT ROW 42 LT INOPERATIVE. RELAMPED, OP CHECKED NORMAL.SDR UALA2011113006584Lamp · inoperativeEMERGENCY CEILING LIGHT ABOVE ROW 20 RT INOPERATIVE. RELAMPED, OP CHECKED NORMAL.SDR UALA2011113006582Lamp · inoperativeEMERGENCY CEILING LIGHT ABOVE ROW 16 FWD INOPERATIVE. RELAMPED, OP CHECKED NORMAL.SDR UALA2011113006581Lamp · inoperativeEMERGENCY LIGHT ROW 14 AFT INOPERATIVE. RELAMPED, OP CHECKED NORMAL.SDR UALA2011113006580Lamp · inoperativeEMERGENCY CEILING LIGHT ABOVE ROW 13 INOPERATIVE. RELAMPED, OP CHECKED NORMAL.SDR UALA2011113006577Hose · leakingCREW REPORT: RUNNING WATER LEAK INSIDE LAV 105 REF DF872 WATER SOV SHOULD ALREADY BE IN OFF POSITION. SAMC TEXT: F/O CONFIRMED SOV IS IN THE OFF POSN, WATER STILL LEAKING. MAINT PLZ DEBRIEF FLT CREW UPON LANDING. :REF PTT 5432015 AND 5432016 FOR HOSES REPSDR UALA2011113006573Feeder Cable · damagedEMERGENCY LIGHTS INOPERATIVE, REPLACED UNDERSEAT CABLE. REPLACED LAMP ASSY AT 52ABC. REPLACED EMERGENCY LIGHT AT GALLEY AREA LOWER WALL FWD. ALL EMERGENCY LIGHTS OPERATE NORMAL.
Back to Boeing 747-422