Boeing 747-446
Service difficulty reports · 932
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '747446' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '747446' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UIEA2017042600651Skin · delaminatedLEFT WING LE UPPER SKIN ILES 630-662 HAS EDGE DELAMINATION AND CORNER CRACKED. AREA PREPPED AND CLEANED FOR REPAIR IAW SRM 51-70-06-OG-0. CLEANED THE SURFACE IAW AMM 51-21-02. APPLIED TOP COAT IAW AMM 51-24-11.SDR UIEA2017042600652Skin · delaminatedLEFT WING LE UPPER SKIN ILES 693-704 HAS EDGE DELAMINATION AND DAMAGED FASTENER HOLE. AREA PREPPED AND CLEANED FOR REPAIR IAW SRM 51-70-06-0G-0. CLEANED THE SURFACE IAW AMM 51-21-02. APPLIED TOP COAT IAW AMM 51-24-11.SDR UIEA2017042600653Skin · delaminatedRIGHT WING FIXED LE UPPER SKIN HAS EDGE DELAMINATION AND DAMAGED FASTENER HOLES. AREA PREPPED AND CLEANED FOR REPAIR IAW SRM 51-70-06. CLEANED THE SURFACE IAW AMM 51-21-02. APPLIED TOP COAT IAW AMM 51-24-11.SDR UIEA2017042600654Battery Pack · inoperativeL1 DOOR AREA EMERGENCY LIGHTS INOPERATIVE. REPLACED THE POWER SUPPLY BATTERY AND PERFORMED POWER SUPPLY TEST IAW AMM 33-51-04 ITEM E AND NO DEFECT NOTED.SDR UIEA2017042600655Spar Cap · damagedNR 2 PYLON UPPER WING AT & AROUND FRONT SPAR CAP UNDER PANEL 65B14963. OVERSIZED THE FASTENER HOLES IAW SRM 51-40-05, FIG 2, DETAIL 1, FIG 4, SHEET 1.SDR UIEA2017042600656Skin · delaminatedRIGHT WING LE UPPER SKIN ILES 630-662 HAS EDGE DELAMINATION AND RIGHT CORNER CRACK. PREPPED AND CLEANED THE AREA AND APPLIED A REPAIR IAW SRM 51-70-06 AND APPLIED TOPCOAT IAW AMM 51-24-22-370-80L.SDR UIEA2017042600659Panel · crackedLEFT WING UPPER SURFACE WS 863, FIXED LEADING EDGE PANEL HAS CRACK GOING FWD TO AFT OF PANEL. REPAIRED THE L/E PANEL IAW SRM 51-70-17-0G-0.SDR UIEA2017042600660Structure · delaminatedNR 3 ENGINE OUTBD THRUST REVERSER HAS POSSIBLE DELAMINATED ON INNER UPPER AREA NRI 3162. REPAIRED THE THRUST REVERSER IAW EO 1978A138-CS.SDR UIEA2017042600662Actuator · corrodedLEFT BODY GEAR ACTUATOR HAS CORROSION. REMOVED & REPLACED THE ACTUATOR IAW AMM TASK 32-33-01-004-001, & TASK 32-33-01-404-009. LEAK CHECKED, EXTENSION & RETRACTION TEST ACCOMPLISHED.SDR UIEA2017042600663Actuator · corrodedRIGHT BODY GEAR ACTUATOR HAS CORROSION. REMOVED & REPLACED THE R/H BODY GEAR ACTUATOR IAW AMM 32-33-01-00-001/ 32-33-01-404-009. CHECK OF THE EXTENSION & RETRACTION OF THE ACTUATOR AND LEAK CHECK ACCOMPLISHED.SDR UIEA2017042600664Frame Splice · crackedWHILE PERFORMING NDT OPEN HOLE INSPECTION ON BS 2598 BULKHEAD, LEFT FWD INNER FRAME AND SPLICE FITTING, FOUND LOWER HOLE CRACKED IN SPLICE FITTING ONLY. REAMED TO .3235 IAW MESSAGE PMO-TLS-17-0015-51B.SDR KCSA2017041905Engine · stalledSTALL WITH CONSTANT POWER, NORMAL AT REDUCED POWER, NOT SHUTDOWN THE NR 3 ENGINE. REMOVED AND REPLACED NR 3 ENGINE IAW AMM 71-00-02. ALL TESTED GOOD AND TASK CARD 71-001-00-00.SDR UIEA2017041400578Warning Message · false activationSTAB CONFIGURATION EICAS MESSAGE DURING TAKEOFF ROLL. REJECTED TAKEOFF COMPLIED WITH FIM 31-51, TASK 807, RESET MAWEA CONFIGURATION WARNING CARD. PERFORMED TAKEOFF WARNING TEST, PASSED.SDR KCSA2017040203Lamp · inoperativeLEFT UPPER DECK EMERGENCY DOOR GROUND MODE INOPERATIVE. REPLACED THE LAMP IAW AMM 52-23-13. CHECKED GOOD.SDR KCSA2017032602Lamp · inoperativeLEFT UPPER DECK EMERGENCY DOOR BATTERY PACK FAILED A CHECK. REPLACED THE LAMP IN THE BATTERY LIGHT SWITCH IAW SWPM 20-84-13. OPS CHECKED GOOD IAW MM 52-23-00. NO DEFECTS NOTED.SDR UIEA2017030200250Fire Warning · false activationAPU FIRE INDICATION DURING ROLL OUT AFTER LANDING, PULLED APU FIRE HANDLE AND DISCHARGED FIRE BOTTLE. APU FIRE WARNING LIGHT WAS A FALSE INDICATION. LIGHT REMAINED ON ABOUT 10-12 MINUTES. CHECKED AND INSPECTED APU AND FIRE LOOPS AND FOUND ALL NORMAL.SDR KCSA201702211010Light · inoperativeUPPER DECK EMERGENCY LIGHTS BOTH L- AND R- AT DOOR CENTER AFT INOP. NO TEST OR ON.SDR KCSA201702211009Light · illuminatedUPPER DECK EMERGENCY LIGHTS AT UPPER DECK DOORS AND CENTER CEILING DROP DOWN STAY ON WITH POWER OFF AND SWITCH OFF.SDR KCSA201702211008Light · inoperativeUPPER DECK EMERGENCY LIGHTS CENTER BETWEEN DOORS AND BELOW BEACON DO NOT TEST.SDR KCSA201702211007Light · inoperativeUPPER DECK R - DOOR FWD EMERGENCY LIGHT IN DOOR INOP.SDR KCSA201702211006Light · inoperativeUPPER DECK L - DOOR FWD EMERGENCY LIGHT IN DOOR INOP.SDR KCSA201702211005Light · inoperativeMAIN DECK CARGO EMERGENCY LIGHT AT L1 DOOR INOP.SDR KO0R201702160007Skin · corrodedRT HORIZONTAL STABILIZER UPPER SKIN IS CORRODED AT STAB STATION 150 STRINGER 15 & 16.SDR KCSA201702101004Access Panel · corrodedINBD MID FLAP UPPER SURFACE APPROX. 30 INCHES INBD AND 18 INCHES FROM BOTTOM EDGE HAS DAMAGED FASTENERS.SDR KO0R201702100006Skin · chafedFUSELAGE SKIN PANEL UNDERNEATH THE RT HORIZONTAL STABILIZER AT BS 2484 HAS EVIDENCE OF CHAFING STRINGERS 16 TO 20R.SDR UIEA2017020100139Light · malfunctionedEMERGENCY LIGHTS AT L4 DOOR INTERMITTENTLY ILLUMINATING. CYCLED EMERGENCY LIGHTS, OPS CHECKED NORMAL IAW AMM 33-51-01.SDR KCSA201701131002Web · crackedTHROUGH TUNNELS, FURTHEST POINT TO RADOME BULKHEAD, FURTHEST POINT L/H SIDE, CEILING WEB HAS CRACK 4 INCHES IN LENGTHSDR KCSA201701091001Bulkhead · corrodedLEFT WING NR 2 TANK FWD JETTISON PUMP HAS EVIDENCE OF CORROSION AT BONDING HOLE.SDR KCSA201701051000Stringer · crackedSTA 800 STR 17R UPPER AFT HOLE HAS CRACK IN STRINGER.SDR KCSA201610311092Light · inoperativeTHREE EMERGENCY LIGHTS IN UPPER DECK CEILING INOPERATIVE.SDR KCSA201610311091Light · inoperativeEMERGENCY LIGHT IN STAIRWAY GOING FROM MAIN DECK TO UPPER DECK INOPERATIVE.SDR KCSA201610271090Stringer Splice · dentedE&E BAY BILGE AREA, BS 406.0, STRINGER 42R HAS DENT IN STRINGER SPLICE ON FREE FLANGE AND WEB AREA.SDR UIEA2016101700816Lamp · inoperativeRIGHT OVERWING EMERGENCY LIGHTS AFT 2 AND 1ST FWD INOPERATIVE. REMOVED AND REPLACED THE BULBS IAW AMM.SDR UIEA2016101700815Connector · disconnectedUPPER DECK AFT LEFT EMERGENCY AISLE LIGHT INOPERATIVE. FOUND CABLE DISCONNECTED. RECONNECTED CABLE TO UPPER DECK AFT EMERGENCY LIGHT IAW AMM TASK 33-51-00-432-006 OPS CHECKED GOOD IAW TASK 33-57-00-715-105.SDR UIEA2016101700814Battery · inoperativeL5 DOOR SLIDE LIGHT AND UPPER DECK LT WING DOOR SLIDE LIGHT EMERGENCY LIGHTS INOPERATIVE. REPLACED THE BATTERY PACKS AT L5 DOOR SLIDE LIGHT IAW AMM TASK 33-57-06-400-701, REPLACED THE LAMPS UPPER DECK GULL WING DOOR LT IAW AMM TASK 330-51-07-962-028, OPS CHESDR UIEA2016101700813Lamp · inoperativeEMERGENCY IGHTS INOPERATIVE. REPLACED THE LAMPS IAW AMM TASK 35-51-07-962-028. OPS CHECKED GOOD IAW AMM TASK 33-51-90-215-105.SDR UIEA2016101700812Lamp · inoperativeL1 AND R3 OVER DOOR EMERGENCY LIGHTS INOPERATIVE. REPLACED THE LAMP IAW AMM TASK 33-51-07-962-028. OPS CHECKED GOOD IAW AMM TASK 33-51-00-715-105.SDR UIEA2016101700811Lamp · inoperativeL2, R2, L3, R3, R4, L5, R5 DOOR SILL EMERGENCY LIGHTS INOPERATIVE. REPLACED THE LAMPS IAW AMM TASK 33-51-05-962-031, OPS CHECKED GOOD IAW AMM TASK 33-51-00-715-105.SDR KCSA201600904Actuator · malfunctionedDOOR UPPER DECK FLIGHT LOCK MALFUNCTIONED. REMOVED AND REPLACED FLIGHT LOCK ACTUATOR AND OPS CHECKED GOOD IAW MM 52-23-08.SDR UIEA2016090600746Battery Pack · inoperativeEMERGENCY LIGHTS INOPERATIVE. R & R THE BATTERY PACK IAW AMM 33-51-04, OPS CHECKED GOOD.SDR UIEA2016090600747Battery Pack · inoperativeDURING INSPECTION, FOUND LUD POWER ASSIST BATTERY INOPERATIVE. REPLACED THE BATTERY PACK IAW AMM 33-51-04, OPS OK.SDR KCSA2016082702Slide · deployedUPPER DECK, RT SIDE ESCAPE SLIDE DEPLOYED. REMOVED DEPLOYED SLIDE IAW MM 25-68-00, PG 201; SECURED SLIDE IN AFT BULK. INSTALLED RT UPPER DECK SLIDE ASSEMBLY IAW 25-68-01 UP T-STEP 13. SAFETY PINS WILL REMAIN INSTALLED IN BOTH RESERVOIRS. INSTALLED FORWARD SDR KCSA201608221052Light · inoperativeTWO EMERGENCY LIGHTS IN UPPER DECK INOPERATIVE.SDR UIEA2016080100651Wire · damagedCABIN EMERGENCY LIGHTS ARE INOPERATIVE. REPAIRED WIRING TO LIGHTS IAW 20-10-17. ALL CHECKED GOOD AT THIS TIME.SDR UIEA2016072000600Warning System · activatedCREW PERFORMED LOW SPEED REJECTED T/O WHEN EICAS MSG FOR OVERRIDE JETT PUMP NR 3 FWD APPEARED. PLACED ON DMI.SDR UIEA2016062800527Oven · smokeOVEN 60-3 BEGAN SMOKING AND HAD STRONG ELECTRICAL BURNING ODOR. ITEM TRANSFERRED TO MDDR 67915 IAW DDG 25-20-01, GALLEY ITEM 6.SDR UIEA2016062300456Lens · looseEMERGENCY LIGHT COVER IN MID GALLEY LOOSE. SECURED LENS ASSY AT MID GALLEY, OPS NORMAL IAW AMM 33-50-00.SDR UIEA2016060600405A/C Pack · faultyEICAS MSG PACK 3. NOTED STRONG FUMES IN COCKPIT. NR 3 PACK CONFIRMED FAULTY & PLACED ON DMI IAW DDG 21-51-01-01.SDR UIEA2016052300347Wire · damagedEMERGENCY EXIT LIGHT BETWEEN L2 & R2 DOOR INOPERATIVE & FLOOR LIGHTING AT L5 & R5. SPLICED EMER LIGHT WIRES, BETWEEN L2 & R2 DOORS, BETWEEN L5 & R5 DOORS IAW SWPM 20-30-12. OPERATIONS CHECKED GOOD IAW AMM 33-51-00.SDR UIEA2016050300263Life Raft · missingR5 DOOR LIFE RAFT IS MISSING. INSTALLED R5 DOOR LIFE RAFT IN OVERHEAD BIN IAW AMM 25-62-02.
Back to Boeing 747-446