Boeing 747-SR-46
Service difficulty reports · 412
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '747SR46' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '747SR46' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UPS403885Skin · damagedWHILE IN FOR C-CHECK, MAINTENANCE FOUND DAMAGE ON OUTER SKIN OF PYLON NR 4 AT STA 210. REPAIRED IAW SRM 54-30-03.SDR UPS403884Skin · crackedWHILE IN FOR C-CHECK, MAINTENANCE FOUND CRACK ON OUTER SKIN OF PYLON NR 4 OF ACCESS PANEL AT STA 195, LT. REPAIRED IAW SRM 54-30-03.SDR UPS403883Skin · damagedWHILE IN FOR C-CHECK, MAINTENANCE FOUND LOWER FUSELAGE EXTERNAL SKIN DAMAGED AT STA 560 LT SIDE STRINGER 43. REPAIRED IAW SRM 53-30-03.SDR UPS403022Eel Battery Pack · dischargedMAINTENANCE REPORTED, EMER CEILING LIGHT, UPPER DECK MOST AFT INOP ON TEST. REPLACED BATTERY PACK, OPS CK OK.SDR UPS403021Eel Battery Pack · dischargedMAINTENANCE REPORTED, EMER EXIT SIGN ABOVE CREW EMER DOOR EXIT LIGHTS INOP. REPLACED BATTERY PACK, OPS CHECK OK.SDR UPS403020Eel Battery Pack · dischargedMAINTENANCE REPORTED, LT UPPER DECK AISLE EMER LIGHT INOP. REPLACED EMER LIGHT ASSY, OPS CK OK.SDR UPS403019Eel Battery Pack · dischargedMAINTENANCE REPORTED, STAIRWELL EMERGENCY LIGHT INOP. REPLACED BATTERY PACK, OPS CHECK OK.SDR UPS403017Eel Battery Pack · dischargedMAINTENANCE REPORTED, THE TWO EMER LIGHTS ABOVE UPPER DECK CREW EMER DOOR EXIT INOP. REPLACED BATTERY PACK.SDR UPS403018Eel Battery Pack · dischargedMAINTENANCE REPORTED, UPPER DECK CREW EMER EXIT DOOR SILL/SLIDE LIGHTS (2 EA) INOP. REPLACED BATTERY PACK, OPS CHECK OK.SDR UPS402943Fuel Pump · malfunctionedPILOT REPORTED, ENGINE FLAME-OUT AT FL 350. **S/D** REPLACED FUEL PUMP PER EO J T9D 7100-3426 AND TEST 3, 5 MM 71-00-00. LEAK AND OPERATIONAL CHECK OK.SDR UPS802935Eel · inoperativeMAINTENANCE REPORTED EMER EXIT LIGHTS INOP, BY FWD ENTRY DOOR AND AFT ENTRY DOOR 2 EA.SDR UPS402186Eel · inopMAINTENANCE FOUND THE FOLLOWING EMERGENCY LIGHTS (INCANDESCENT LIGHTS) UNDER THE INST GLARESHIELD ARE BURNED OUT: CAPTAIN'S SIDE 2ND FROM LEFT, CENTER 2ND FROM LEFT, F/U SIDE LEFT MOST BULB. REPLACED BULBS. OPS CHECK GOOD.
Back to Boeing 747-SR-46